510(k) Data Aggregation

    K Number
    K251644

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-06-24

    (26 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ProAM ALIF System is an intervertebral body fusion device intended for spinal fusion procedures at one or two contiguous levels of the lumbosacral (L2-S1) spine in skeletally mature patients with degenerative disc disease (DDD), degenerative spondylolisthesis, and/or spinal stenosis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and imaging studies (radiographs, CT, MRI). DDD patients may also have up to grade 1 spondylolisthesis or retrolisthesis at the involved levels. These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s).

    The ProAM ALIF System can be used as an adjunct to fusion in patients diagnosed with multilevel degenerative scoliosis and sagittal deformity. However, when used in these patients at multiple levels, and for patients with degenerative spondylolisthesis and spinal stenosis at one or two adjacent levels, the system must be used with supplemental spinal fixation systems cleared by the FDA for fusion of the lumbar spine in addition to the integrated fixation.

    Interbody devices used with three fully threaded bone screws and which have a lordotic angle of 20° or less can be used as standalone interbody fusion devices at one or two contiguous levels without the need for supplemental fixation. Interbody devices with a lordotic angle greater than 20° must be used with supplemental spinal fixation systems cleared by the FDA for fusion of the lumbar spine in addition to the integrated fixation. Interbody devices used with fewer than three fixation components (OLIF devices and 2-Hole ALIF devices) or used with anchors or impacted screws must be used with supplemental spinal fixation systems cleared by the FDA for fusion of the lumbar spine in addition to the integrated fixation.

    The ProAM ALIF System is intended for use on patients who have had at least six months of nonoperative treatment. It is intended to be used with autograft and/or allogenic bone graft comprised of cortical, cancellous, and/or corticocancellous bone, and/or demineralized allograft bone with bone marrow aspirate.

    Device Description

    The ProAM ALIF System is an intervertebral body fusion system that consists of an intervertebral body fusion device manufactured from titanium alloy (Ti-6Al-4V conforming to ASTM F3001) and fixation devices manufactured from titanium alloy (Ti-6Al-4V conforming to ASTM F136).

    The intervertebral body fusion device has a cross-sectional shape that is somewhat oval, and the device is otherwise box-shaped in stature with cavities for containment of bone graft material. The device is available in sizes that vary in footprint size, height, and lordotic angle. It is available in configurations meant for direct anterior insertion (ALIF) or oblique-anterior (OLIF) insertion. Devices for implantation via a direct anterior approach are available with 2 or 3 holes through which screws are placed to affix to bone. Devices for implantation via an oblique-anterior approach have 2 holes through which screws are placed to affix to bone. All devices have an open, porous architecture throughout and a pyramidal textured porous surface at the endplate contacting surfaces that helps prevent device migration.

    The fixation devices consist of Bone Screws, Impacted Screws, and Curved Anchors. Bone Screws are available in various diameters and lengths and engage the vertebral bodies by passing through the intervertebral body fusion device and into bone. They are turned to fixate to the bone. Impacted Screws are available in various lengths. They are first impacted through the intervertebral body fusion device into bone and then turned to further fixate to the bone. Curved Anchors are available in various lengths and are impacted into the bone through the intervertebral body fusion device.

    The purpose of this premarket notification is to add the Impacted Screws and Curved Anchors as fixation devices for the ProAM ALIF System

    AI/ML Overview

    The provided FDA 510(k) clearance letter for the ProAM ALIF System does not contain any information regarding acceptance criteria or a study proving the device meets those criteria, as typically seen for AI/ML-based medical devices.

    This document is a standard 510(k) clearance for an intervertebral body fusion device, which is a physical implant. The information provided focuses on material composition, mechanical testing (static and dynamic cantilever, expulsion), and substantial equivalence to predicate devices based on design, indications for use, and performance of the physical implant.

    Therefore, I cannot answer the questions posed regarding acceptance criteria, study details, sample sizes, expert ground truth, MRMC studies, standalone performance, training sets, or adjudication methods, as these are all relevant to the evaluation of AI/ML or software-driven medical devices, not a physical orthopedic implant like the ProAM ALIF System.

    The questions are highly appropriate for an AI/ML medical device, but the provided text is a clearance letter for a mechanical implant.

    Ask a Question

    Ask a specific question about this device

    K Number
    K240126

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-05-03

    (108 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ProAM ALIF System is an intervertebral body fusion device intended for spinal fusion procedures at one or two contiguous levels of the lumbrosacral (L2-S1) spine in skeletally mature patients with degenerative disc disease (DDD), degenerative spondylolisthesis, and/or spinal stenosis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and imaging studies (radiographs. CT. MRI). DDD patients may also have up to grade 1 spondylolisthesis or retrolisthesis at the involved levels. These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s).

    The ProAM ALIF System can be used as an adjunct to fusion in patients diagnosed with multilevel deqenerative scoliosis and sagittal deformity. However, when used in these patients at multiple levels, and for patients with degenerative spondylolisthesis and spinal stenosis at one or two adjacent levels, the system must be used with supplemental spinal fixation systems cleared by the FDA for use in the lumbar spine in addition to the integrated fixation.

    Interbody devices used with three screws and which have a lordotic angle of 20° or less can be used as standalone interbody fusion devices at one or two contiguous levels without the need for supplemental fixation.

    Interbody devices with a lordotic angle greater than 20° must be used with supplemental spinal fixation systems cleared by the FDA for use in the lumbar spine in addition to the integrated fixation. Interbody devices used with fewer than three screws (OLIF devices and 2-Hole ALIF devices) must be used with supplemental spinal fixation systems cleared by the FDA for use in the lumbar spine in addition to the integrated fixation.

    The ProAM ALIF System is intended for use on patients who have had at least six months of nonoperative treatment. It is intended to be used with autograft and/or allogenic bone graff comprised of cortical, cancellous, and/or corticocancellous bone, and/or demineralized allograft bone with bone marrow aspirate.

    Device Description

    The ProAM™ ALIF System is an intervertebral body fusion system that consists of an intervertebral body fusion device manufactured from titanium alloy (Ti-6Al-4V conforming to ASTM F3001) and screws manufactured from titanium alloy (Ti-6Al-4V conforming to ASTM F136).

    The intervertebral body fusion device has a cross-sectional shape that is somewhat oval, and the device is otherwise box-shaped in stature with cavities for containment of bone graft material. The device is available in sizes that vary in footprint size, height, and lordotic angle. It is available in configurations meant for direct anterior insertion (ALIF) or oblique-anterior (OLIF) insertion. Devices for implantation via a direct anterior approach are available with 2 or 3 holes through which screws are placed to affix to bone. Devices for implantation via an oblique-anterior approach have 2 holes through which screws are placed to affix to bone. All devices have an open, porous architecture throughout and a pyramidal textured porous surface at the endplate contacting surfaces that helps prevent device migration.

    The fixation devices consist of screws that are available in various diameters and lengths. Screws engage the vertebral bodies by passing through the intervertebral body fusion device and into bone. They are turned to fixate to the bone.

    AI/ML Overview

    I am sorry, but the provided text does not contain the detailed information necessary to answer your request regarding acceptance criteria and a study proving device performance.

    The document is a 510(k) summary for the ProAM ALIF System, which is a premarket notification for a medical device. This type of document primarily focuses on establishing "substantial equivalence" to existing legally marketed predicate devices, rather than providing a detailed report on a specific study designed to meet pre-defined acceptance criteria for performance.

    While the document mentions "mechanical testing" was performed (static and dynamic compression, compression-shear, subsidence, and expulsion testing), it does not include:

    • A table of acceptance criteria and reported device performance. It only states that the testing demonstrated the device performs "as well or better than the predicates."
    • Sample sizes used for the test set.
    • Data provenance (country of origin, retrospective/prospective).
    • Number of experts and their qualifications used to establish ground truth.
    • Adjudication method.
    • Whether a multi-reader multi-case (MRMC) comparative effectiveness study was done.
    • Whether a standalone performance study was done.
    • The type of ground truth used.
    • Sample size for the training set.
    • How ground truth for the training set was established.

    These details are typical for studies assessing the performance of AI/ML or diagnostic devices against specific clinical endpoints or reference standards. The ProAM ALIF System is an intervertebral body fusion device, and the "performance data" refers to mechanical integrity and suitability for its intended biomechanical function, compared to predicate devices.