Search Filters

Search Results

Found 61 results

510(k) Data Aggregation

    K Number
    K253905

    Validate with FDA (Live)

    Date Cleared
    2026-04-07

    (123 days)

    Product Code
    Regulation Number
    876.1500
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K253959

    Validate with FDA (Live)

    Device Name
    Primevision 3D
    Manufacturer
    Date Cleared
    2026-02-05

    (57 days)

    Product Code
    Regulation Number
    892.1750
    Age Range
    0 - 21
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The X-ray system creates data for digital exposures in the maxillofacial area and in sub-areas for dentistry and pediatric dentistry and for hard tissue diagnostics within ENT medicine.

    Device Description

    Primevision 3D is a digital panoramic and cone beam computed tomography (CBCT) x-ray device. A Computed tomography x-ray system (21 CFR 892.1750) is intended to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from the same axial plane taken at different angles. The subject Primevision 3D uses just one imaging detector to collect data for both 2D and 3D modes of operation. Additionally, the Primevision 3D does not offer a cephalometric mode.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250739

    Validate with FDA (Live)

    Date Cleared
    2025-11-07

    (241 days)

    Product Code
    Regulation Number
    872.5470
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Primeprint Aligner is a light curing resin intended for the treatment of tooth malocclusion in patients with developed permanent dentition. Primeprint Aligner repositions teeth by way of continuous gentle force.

    Intended place of use: Orthodontic/dental practices/clinics, dental laboratories

    Device Description

    Primeprint Direct Aligner is a light-curing material for the production of aligners using the Primeprint Solution (Primeprint 385nm DLP 3D printer and Primeprint Post Processing Unit). The material is intended for the treatment of tooth malocclusion in patients with developed permanent detention. Primeprint Direct Aligner repositions teeth by way of continuous gentle force.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252964

    Validate with FDA (Live)

    Date Cleared
    2025-11-04

    (48 days)

    Product Code
    Regulation Number
    878.4040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    PRIMED Surgical masks are single use, non-sterile, disposable products intended to be worn by healthcare personnel in healthcare settings and during surgical procedures to protect both the patient and healthcare personnel from transfer of microorganisms, body fluid and particulate materials.

    PRIMED Procedure Masks are single use, non-sterile, disposable products intended to be worn by healthcare personnel in healthcare settings to protect both the patient and healthcare personnel from transfer of microorganisms, body fluid and particulate materials.

    Device Description

    PRIMED Surgical masks and PRIMED Procedure masks are single use, non-sterile masks composed of a melt-blown filter layer placed between layers of non-woven inner and SS outer layer(s) material. PRIMED Medical Products Inc. offers various models in two main categories: Procedure masks with ear loops and Surgical masks with head ties. The level of protection varies based on the basis weight of the inner layer and the number of outer layers used in the mask's construction, in accordance with ASTM F2100:2023 specifications.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252441

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-09-29

    (56 days)

    Product Code
    Regulation Number
    870.1340
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Primero Safe Access System is intended to facilitate placing a catheter through the skin into a vein or artery. The introducer needle is used in facilitating entry through the skin into a vein or artery to provide a conduit for the guidewire. The guidewire is an accessory device which is used for placement of a catheter or sheath in the vein or artery.

    Device Description

    The Primero Safe Access System (SAS) is a catheter introducer that facilitates a quick approach for placement of a guidewire during the introduction of a catheter for vascular access. The Primero SAS combines an introducer needle, guidewire, advancer, and storage tube into a single integrated device to promote ease of use and quick access by the healthcare provider. The introducer needle consists of an 18Ga stainless steel needle with an echogenic tip and terminates on the proximal end with a colored translucent standard female luer lock hub. The introducer needle has an enhanced echogenic tip, that has been slightly modified to incorporate a small bulb-like feature at the proximal end of the tip bevel to enhance ultrasonic visualization during vascular access. The introducer needle is secured to the advancer through a luer lock connector at the distal end of the advancer. The advancer is a light-weight polymer handpiece that allows the user to grip the entire setup while introducing the needle into the vessel and then advancing the guidewire through the needle by either 'thumb" or 'two-finger" advancing based on the preference of the user. A cutout in the advancer handpiece wire path exposes the guidewire and conveniently allows the user to advance the guidewire with their fingers without having to let go of the handpiece. An internal path within the handpiece feeds the guidewire from a storage tube into the introducer needle. The looped storage tube is connected to the proximal end of the advancer and holds a spooled pre-loaded guidewire ready for deployment. A back stop has been inserted into the tube at the proximal end to prevent a guidewire from being over-retracted from the advancer. The Primero SAS is pre-loaded with a commercially available guidewire (previously cleared under K142393) ready for deployment through the introducer needle once placed in the target vessel. The guidewire is comprised of an uncoated nitinol core wire that is tapered at the distal tip where a stainless-steel coil is secured over the full-length of the core. The South53 Primero Safe Access System (SAS) integrates all the necessary elements into a single device to complete the Seldinger technique as part of a vascular access procedure.

    The Primero SAS is provided sterile and is intended for single patient use. The device is not intended to be re-sterilized or re-used.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250771

    Validate with FDA (Live)

    Device Name
    Primescan 2
    Date Cleared
    2025-08-29

    (169 days)

    Product Code
    Regulation Number
    872.1745
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Primescan 2 can be used as a diagnostic aid by licensed dentists for detection of caries on visible tooth surfaces, proximal caries, and tooth cracks.

    Device Description

    The Primescan 2 is an intraoral scanner that records and generates digital images to provide caries diagnosis support using additional light sources at 405 nm and 850 nm and an optical filter to filter out the excitation light. By illuminating the tooth with these two wavelengths, two diagnosis support modes are realized, the fluorescence mode and the near-infrared mode. The acquired 2D data from the scanner can be viewed in the software in a live stream video during acquisition. The images are also stored in the cloud platform software for later patient communication.

    In fluorescence mode, the tooth (or teeth) are illuminated with UV light (405 nm). This stimulates an autofluorescence of the enamel in the green wavelength range. In addition, the red fluorescence is stimulated in carious areas on the teeth. All stimulated fluorescence responses are significantly weaker in terms of their light intensity compared to the back-reflected excitation light. For this reason, the excitation light is filtered out with the aid of an optical filter. The dental professional can use the 2D image data of the fluorescence response (live stream video) as additional information for caries diagnosis.

    For near-infrared mode (NIR mode), the tooth or teeth are illuminated with 850 nm. Enamel is partially transparent in this wavelength. The illumination can therefore penetrate the tooth and is reflected by structural defects such as cracks and cavities, as well as from the dentin core. The reflected light is picked up by the 2D sensor of the scanner.

    When used, a sleeve is placed over the distal end of the scanner. This sleeve is the only patient contacting component and is offered as either a single-use disposable or a multi-use sleeve that is reprocessed.

    AI/ML Overview

    Here's the breakdown of the acceptance criteria and study information for the Primescan 2 device, based on the provided FDA 510(k) clearance letter:


    Acceptance Criteria and Device Performance

    The provided document does not explicitly state quantitative acceptance criteria or a specific table outlining them. However, it does mention that "in vivo bench tests demonstrated that Primescan-2 is effective as a diagnostic aid for occlusal caries using the fluorescence function and tooth cracks using the NIR function." This implies that the device met an unstated level of effectiveness for these diagnostic aids.

    Since specific quantitative metrics (e.g., sensitivity, specificity, accuracy) are not provided in the summary, we cannot populate a detailed table with numerical acceptance criteria and performance outcomes.

    Acceptance CriterionReported Device Performance
    Effectiveness as diagnostic aid for occlusal caries (fluorescence mode)Demonstrated effectiveness
    Effectiveness as diagnostic aid for tooth cracks (NIR mode)Demonstrated effectiveness

    Study Details

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: Not specified in the provided document.
    • Data Provenance: The study was "in vivo bench tests," implying data was collected from living subjects. The country of origin and whether it was retrospective or prospective is not explicitly stated.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Number of Experts: Not specified.
    • Qualifications of Experts: Not specified.

    4. Adjudication method for the test set

    • Adjudication Method: Not specified.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: Not mentioned in the provided document. The study described is "Performance Validation Testing of the Caries diagnostic Aid - In vivo bench tests demonstrated that Primescan-2 is effective as a diagnostic aid..." This describes standalone device performance rather than human-in-the-loop improvement.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    • Standalone Performance Study: Yes, a standalone performance study was done. The document states: "Performance Validation Testing of the Caries diagnostic Aid - In vivo bench tests demonstrated that Primescan-2 is effective as a diagnostic aid for occlusal caries using the fluorescence function and tooth cracks using the NIR function." This indicates the device's ability to provide a diagnostic aid on its own.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • Type of Ground Truth: Not explicitly stated. For "in vivo bench tests" related to caries and tooth cracks, ground truth would typically be established through a combination of visual-tactile examination by experienced clinicians, potentially supplemented by radiography or even histology (though less common for a diagnostic aid). However, the document does not specify the method used here.

    8. The sample size for the training set

    • Sample Size for Training Set: Not applicable or not specified. This device appears to be a direct imaging and diagnostic aid rather than an AI/ML algorithm that requires a separate training set. The "diagnostic support" refers to the illumination and optical filtering techniques, not necessarily an AI algorithm trained on a dataset.

    9. How the ground truth for the training set was established

    • Ground Truth for Training Set: Not applicable, as there's no indication of an AI/ML algorithm with a training set. The device operates on optical principles.

    Key Observations and Limitations of Information:

    • The provided 510(k) summary focuses highly on technological comparisons, safety, and regulatory compliance (electrical safety, biocompatibility, reprocessing, software, cybersecurity).
    • While it mentions "Performance Validation Testing," it lacks specific quantitative results (e.g., sensitivity, specificity, accuracy, AUC) that are typically associated with diagnostic device clearances.
    • The clinical study details, such as sample size, expert qualifications, and ground truth establishment methods for the performance validation, are not provided in this specific document. This information would typically be in a more detailed study report submitted to the FDA, but is summarized very broadly here.
    • The device is described as providing "diagnostic support" using optical modes (fluorescence and NIR), rather than an explicit AI algorithm.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242208

    Validate with FDA (Live)

    Date Cleared
    2024-10-07

    (70 days)

    Product Code
    Regulation Number
    880.6850
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The PRIMED Sterilization wraps are intended to be used to enclose another medical device that is to be sterilized by a health care provider via the following:

    • Pre-Vacuum Steam at 270°F/ 132°C for 4 minutes. The wrap has been validated for dry time of 20 minutes for P100 and P200 and dry time of 30 minutes for P300, P400, P500 and P600.
    • 100% Ethylene Oxide Sterilization with a concentration of 725-735 mg/L at 131°F/55°C and 40% 80% relative humidity for 60 minutes. Validated for aeration times of 8 hours at 55°C or 12 hours at 43.3°C.
    • Lumen. Non-Lumen. and Flexible Cycles in the STERIS V-PRO maX/maX2 and STERIS V-PRO 60/s2 low temperature Sterilization Systems.
    • Advanced Sterilization Products STERRAD 100S system
    • Advanced Sterilization Products STERRAD NX [Standard Cycle, Advanced Cycle]
    • Advanced Sterilization Products STERRAD 100 NX [Standard Cycle, Flex Cycle, Express, Duo Cycle]

    PRIMED Sterilization wraps are available in 6 models and different sizes ranging from 12" X 12" to 54" X 90" and are intended to allow sterilization of the enclosed medical device(s) and maintain sterility of the enclosed device(s) for a maximum of 180 days or until used. PRIMED Sterilization wraps are validated for use with above listed sterilization systems with the intended loads as described below.

    Device Description

    The PRIMED Sterilization wraps are made of SMS (Spunbond) Polypropylene with addition of a master batch pigment for coloration and are available in three separate product offerings:

    • 1- The Fused one colour double layer bonded wrap is comprised of two sheets ultrasonically bonded on two parallel sides. The wrap fabrics are composed of polypropylene with the addition of purple pigment. This product allows convenient simultaneous wrapping of medical devices to be sterilized in accordance with standard healthcare practices.
    • 2- The Fused two colours double layer bonded wrap is comprised of two sheets of purple and blue fabrics ultrasonically bonded on two parallel sides. The wrap fabrics are composed of polypropylene with the addition of purple or blue pigment. This product allows convenient simultaneous wrapping of medical devices to be sterilized in accordance with standard healthcare practices.
    • 3-The Single layer one colour wrap is comprised of a single nonwoven sheet. The standard purple wrap is composed of polypropylene with the addition of a purple pigment. Two sheets are used to sequentially wrap medical devices to be sterilized in accordance with standard healthcare practices.

    PRIMED Sterilization wraps are available in various dimensions ranging from 12″ x 12″ x 90″ and six different weights as detailed in table 1.

    AI/ML Overview

    The provided text describes the acceptance criteria and the comprehensive non-clinical testing performed for the PRIMED Sterilization Wrap (P100, P200, P300, P400, P500, P600) to demonstrate its safety and effectiveness.

    1. Table of Acceptance Criteria and Reported Device Performance

    Test PerformedTest MethodAcceptance CriteriaReported Device Performance
    Sterilant PenetrationANSI/AAMI ST79, ANSI/AAMI/ISO 11138-7All BI test samples should be negative for growth following the minimum incubation periodPass
    Maintenance of Package IntegrityANSI/AAMI/ISO 11607-1, AAMI TIR12 ANSI, AAMI ST79Maintain sterility for 180 daysPass
    Maintenance of package sterilityAAMI TIR12 - ANSI/AAMI ST77No growth in any of the culture vessels containing test coupons after the minimum incubation periodPass
    Residual (Ethylene Oxide)ISO 10993-7Less than maximum theoretical residual limits or the tolerable contact limit following a 100% ethylene oxide sterilization processPass
    Biocompatibility (Cytotoxicity, Irritation, Sensitization)ISO 10993-5 and ISO 10993-10non-cytotoxic, non-irritating and non-sensitizingPass
    Physical and Chemical Properties and Material compatibility with the intended sterilization method (PH value, chloride content, sulphate content, colour fastness, Basis weight, Air permeability, Material burst strength, Grab Tensile strength, Trapezoidal Tear strength, Hydrostatic Pressure, Linting)ISO 11607-1 and EN 868-2, ASTM D3776, ASTM D737-04, ASTM D3786, ASTM D5034-09, ASTM D5587-15, AATC127-2014, NWSP 160.1Meets physical and chemical properties, non-sterile and post sterilizationPass

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the numerical sample size for each test set. However, it indicates that the testing was non-clinical. This implies that the data provenance is from laboratory testing and not from human patient data. The origin of the data is implicit in the "non-clinical" nature and the use of ISO/ASTM standards for testing.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    This information is not applicable to this type of device and study. The "ground truth" for sterilization wraps and their performance is established through adherence to recognized international standards (ISO, AAMI, ASTM, EN) and empirical laboratory testing, not through expert consensus from human observation (e.g., radiologists).

    4. Adjudication Method for the Test Set

    This information is not applicable as the evaluations are based on objective laboratory measurements against predefined technical specifications and standards, not on subjective interpretations requiring adjudication.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    This information is not applicable as the device is a sterilization wrap, not an AI-powered diagnostic or assistive tool for human readers.

    6. Standalone Performance Study

    Yes, the studies described are standalone performance studies (algorithm only without human-in-the-loop performance), as they focus on the intrinsic properties and performance of the sterilization wrap itself against established technical and biological criteria. The "algorithm" in this context refers to the defined device specifications and its physical/chemical interactions, not a software algorithm.

    7. Type of Ground Truth Used

    The ground truth used is primarily based on established industry standards and regulatory requirements for medical device sterilization and packaging, including:

    • Biological indicators (for sterilant penetration and sterility maintenance) which have a known, predictable response.
    • Physical and chemical property specifications (e.g., burst strength, air permeability, pH, leachable content) that are objectively measurable and defined by standards.
    • Biocompatibility standards that define acceptable levels of cytotoxicity, irritation, and sensitization.
    • Package integrity criteria for maintaining a sterile barrier for a specified duration.

    8. Sample Size for the Training Set

    This information is not applicable. The device is a sterilization wrap, not an AI/ML-based algorithm that requires a "training set" of data. The development and validation process for this device involves material science, engineering, and microbiology, not machine learning.

    9. How the Ground Truth for the Training Set was Established

    This information is not applicable for the reasons stated in point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K240286

    Validate with FDA (Live)

    Date Cleared
    2024-08-26

    (207 days)

    Product Code
    Regulation Number
    878.4040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    PRIMED Surgical Masks and PRIMED Procedure Masks are single use, non-sterile products intended to be worn by operating room and health care personnel in health care setting and during surgical procedures to protect both the patient and the operating room personnel from transfer of microorganisms, body fluids and particulate materials.

    Device Description

    PRIMED Surgical masks and PRIMED Procedure masks are single use, non-sterile masks composed of a melt-blown filter layer placed between layers of non-woven inner and SS outer layer(s) material. PRIMED Medical Products Inc. offers various models in two main categories: Procedure masks with ear loops and Surgical masks with head ties. The level of protection varies based on the basis weight of the inner layer and the number of outer layers used in the mask's construction, in accordance with ASTM F2100:2023 specifications.

    AI/ML Overview

    The provided text is an FDA 510(k) summary for PRIMED Surgical Masks and PRIMED Procedure Masks. It describes the acceptance criteria and the study that proves the device meets those criteria. However, it does not include information about a complex AI-driven medical device, a multi-reader multi-case (MRMC) study, or detailed information about ground truth establishment by experts as would be relevant for an AI/CADe system.

    Therefore, the following response will be tailored to the information available in the provided document, which pertains to a physical medical device (surgical masks) and its performance against established standards, rather than an AI/software device.

    Here's the information as extracted and interpreted from the document:


    Acceptance Criteria and Device Performance for PRIMED Surgical Masks and PRIMED Procedure Masks

    The device under review is PRIMED Surgical Masks and PRIMED Procedure Masks. The performance of these masks is evaluated against established physical and biocompatibility standards rather than a typical AI/CADe performance criteria.

    1. Table of Acceptance Criteria and the Reported Device Performance

    The acceptance criteria are derived from ASTM F2100-23 standards for medical face masks and other relevant ISO and CFR standards for biocompatibility and flammability.

    Test PerformedTest MethodAcceptance Criteria (Level 1 Masks)Acceptance Criteria (Level 3 Masks)Results (All Variants)
    Bacterial Filtration EfficiencyASTM F2101≥ 95%≥ 98%Pass
    Sub-micron Particulate FiltrationASTM F3502≥ 80%≥ 85%Pass
    Differential Pressure (Breathability)EN 14683< 5 mmH2O/cm²< 6 mmH2O/cm²Pass
    Resistance to Penetration by Synthetic BloodASTM F186280 mmHg160 mmHgPass
    Flammability16 CFR 1610Class IClass IPass
    CytotoxicityISO 10993-5Non-CytotoxicNon-CytotoxicPass
    SensitizationISO 10993-10Non-sensitizingNon-sensitizingPass
    IrritationISO 10993-23Not an irritantNot an irritantPass

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the sample sizes used for each specific test (e.g., number of masks tested for BFE). These are typically defined by the test methodologies themselves (e.g., ASTM F2101 specifies sample sizes).
    The data provenance is from non-clinical testing performed by the manufacturer, PRIMED Medical Products Inc., which is based in Edmonton, AB, Canada. The studies are prospective in the sense that they are conducted specifically for the purpose of demonstrating device performance for regulatory submission.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This section is not applicable as the device is a physical product (surgical masks) and not an AI or diagnostic software. Therefore, human experts are not establishing "ground truth" in terms of clinical diagnoses or interpretations of images. The "truth" is established by direct physical, chemical, and biological testing against engineering and material standards.

    4. Adjudication Method for the Test Set

    This is not applicable as there is no human interpretation or decision-making process being adjudicated. The tests involve objective measurements against predefined thresholds.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. This type of study is relevant for AI/software in diagnostic imaging where human readers' performance with and without AI assistance is evaluated. This submission is for a physical medical device.

    6. If a Standalone (i.e. algorithm only without human-in-the loop performance) was done

    This is not applicable. The device is a physical product (surgical mask), not an algorithm or software. The "performance" is the inherent physical and chemical properties of the mask.

    7. The Type of Ground Truth Used

    The "ground truth" for the performance of the surgical masks is established directly through physical, chemical, and biological laboratory testing against well-defined, objective national and international consensus standards (e.g., ASTM F2100-23, EN 14683, ISO 10993 series, 16 CFR 1610). There is no "expert consensus," "pathology," or "outcomes data" utilized to establish ground truth in the context of diagnostic accuracy for this device.

    8. The Sample Size for the Training Set

    This is not applicable. Surgical masks are physical devices, not AI or machine learning models that require training sets. The document describes performance testing of the final manufactured product.

    9. How the Ground Truth for the Training Set Was Established

    This is not applicable for the same reason as above. There is no training set for a physical device like a surgical mask.

    Ask a Question

    Ask a specific question about this device

    K Number
    K233777

    Validate with FDA (Live)

    Date Cleared
    2024-05-24

    (182 days)

    Product Code
    Regulation Number
    880.6850
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The PRIMED Sterilization wraps are intended to be used to enclose another medical device that is to be sterilized by a health care provider via the following:

    • Pre-Vacuum Steam at 270°F/ 132°C for 4 minutes. The wrap has been validated for dry time of 20 minutes for P100 and P200 and dry time of 30 minutes for P300, P400, P500 and P600.
    • 100% Ethylene Oxide Sterilization with a concentration of 725-735 mg/L at 131°F/55°C and 40% 80% relative humidity for 60 minutes. Validated for aeration times of 8 hours at 55°C or 12 hours at 43.3°C.
    • Lumen. Non-Lumen. and Flexible Cycles in the STERIS V-PRO maX/maX2 and STERIS V-PRO 60/s2 low temperature Sterilization Systems.
    • Advanced Sterilization Products STERRAD 100S system
    • Advanced Sterilization Products STERRAD NX [Standard Cycle, Advanced Cycle]
    • Advanced Sterilization Products STERRAD 100 NX [Standard Cycle, Flex Cycle, Express, Duo Cycle]

    PRIMED Sterilization wraps are available in 6 models and different sizes ranging from 12" X 12" to 54" X 90" and are intended to allow sterilization of the enclosed medical device(s) and maintain sterility of the enclosed device(s) until used. PRIMED Sterilization wraps are validated for use with above listed sterilization systems with the intended loads as described below.

    Device Description

    The PRIMED Sterilization wraps are made of SMS (Spunbond) Polypropylene with addition of a master batch pigment for coloration and are available in three separate product offerings:
    1-The Fused one colour double layer bonded wrap is comprised of two sheets ultrasonically bonded on two parallel sides. The wrap fabrics are composed of polypropylene with the addition of purple pigment. This product allows convenient simultaneous wrapping of medical devices to be sterilized in accordance with standard healthcare practices.
    2- The Fused two colours double layer bonded wrap is comprised of two sheets of purple and blue fabrics ultrasonically bonded on two parallel sides. The wrap fabrics are composed of polypropylene with the addition of purple or blue pigment. This product allows convenient simultaneous wrapping of medical devices to be sterilized in accordance with standard healthcare practices.
    3- The Single layer one colour wrap is comprised of a single nonwoven sheet. The standard purple wrap is composed of polypropylene with the addition of a purple pigment. Two sheets are used to sequentially wrap medical devices to be sterilized in accordance with standard healthcare practices.

    PRIMED Sterilization wraps are available in various dimensions ranging from 12″ x 12″ x 90″ and six different weights as detailed in table 1.

    AI/ML Overview

    The provided document is a 510(k) Summary for the PRIMED Sterilization Wrap. It outlines the device's technical characteristics, intended use, and a comparison to a predicate device, along with a summary of non-clinical testing.

    However, the document does not describe an AI/ML-enabled medical device. It pertains to a physical sterilization wrap. Therefore, the questions related to AI/ML model performance, such as:

    • Sample sizes for test and training sets
    • Data provenance
    • Number and qualifications of experts for ground truth
    • Adjudication methods
    • MRMC studies and effect sizes
    • Standalone AI performance
    • Type of ground truth

    cannot be answered from the provided text. The document focuses on demonstrating substantial equivalence of a physical product to a predicate device through non-clinical testing of its physical, chemical, and functional properties related to sterilization and sterility maintenance.

    Here's an analysis of the acceptance criteria and study as presented for this physical device:

    1. Table of Acceptance Criteria and Reported Device Performance

    Test PerformedTest MethodAcceptance CriteriaResults (Pass/Fail)
    Sterilant PenetrationANSI/AAMI ST79, ANSI/AAMI/ISO 11138-7All BI test samples should be negative for growth following the minimum incubation periodPass
    Maintenance of Package IntegrityANSI/AAMI/ISO 11607-1, AAMI TIR12ANSI, AAMI ST79Maintain sterility for 30 daysPass
    Maintenance of package sterilityAAMI TIR12 -ANSI/AAMI ST77No growth in any of the culture vessels containing test coupons after the minimum incubation periodPass
    ResidualISO 10993-7Less than maximum theoretical residual limits or the tolerable contact limit following a 100% ethylene oxide sterilization processPass
    BiocompatibilityCytotoxicity, Irritation and Sensitization ISO 10993-5 and ISO 10993-10non-cytotoxic, non-irritating and non-sensitizingPass
    Physical and Chemical Properties and Material compatibility with the intended sterilization method, PH value, chloride content, sulphate content, colour fastness, Basis weight, Air permeability, Material burst strength, Grab Tensile strength, Trapezoidal Tear strength, Hydrostatic Pressure, Linting.ISO 11607-1 and EN 868-2, ASTM D3776, ASTM D737-04, ASTM D3786, ASTM D5034-09, ASTM D5587-15, AATC127-2014, NWSP 160.1Meets physical and chemical properties, non-sterile and post sterilizationPass

    2. Sample size used for the test set and the data provenance:

    • The document refers to "non-clinical testing" and does not specify a "test set" in the context of data for an AI/ML model. Instead, it refers to tests performed on the physical sterilization wraps.
    • The sample sizes for each specific physical test (e.g., number of wrap samples for sterilant penetration, integrity, etc.) are not provided in this summary.
    • Data provenance is not applicable in the AI/ML sense; the data is generated from laboratory testing of the physical device. The country of origin for the data (where the tests were conducted) is not specified, but the manufacturer is based in Canada.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable to this device. Ground truth, in this context, refers to established scientific and engineering standards and methods for assessing the performance of sterilization wraps, not expert interpretation of images or clinical data.

    4. Adjudication method for the test set:

    • Not applicable to this device. Testing is based on established laboratory protocols and quantitative or qualitative measurements leading to pass/fail criteria.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done:

    • Not applicable. This device is a physical sterilization wrap, not an AI/ML-assisted diagnostic or treatment aid for humans.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • Not applicable. This is not an algorithm.

    7. The type of ground truth used:

    • For this device, the "ground truth" is established by adherence to recognized international and national standards for medical device sterilization and packaging. These include:
      • ANSI/AAMI ST79 (Comprehensive guide to steam sterilization and sterility assurance in health care facilities)
      • ANSI/AAMI/ISO 11138-7 (Sterilization of health care products - Biological indicators - Part 7: Biological indicators for ethylene oxide sterilization processes)
      • ANSI/AAMI/ISO 11607-1 (Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems)
      • AAMI TIR12 (Guidance for establishing product family groupings for sterilization)
      • ANSI/AAMI ST77 (Sterilization of health care products - Sterile device packaging - Requirements)
      • ISO 10993-5 (Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicity)
      • ISO 10993-10 (Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization)
      • EN 868-2 (Packaging for terminally sterilized medical devices - Part 2: Sterilization wraps - Requirements and test methods)
      • Various ASTM (American Society for Testing and Materials) standards for fabric properties (D3776, D737-04, D3786, D5034-09, D5587-15)
      • AATCC127-2014 (Water Resistance: Hydrostatic Pressure Test)
      • NWSP 160.1 (Nonwoven Standard Procedure for linting)
    • These standards define the methodologies and acceptable performance limits.

    8. The sample size for the training set:

    • Not applicable. This is not an AI/ML model.

    9. How the ground truth for the training set was established:

    • Not applicable.
    Ask a Question

    Ask a specific question about this device

    K Number
    K231804

    Validate with FDA (Live)

    Date Cleared
    2023-11-09

    (142 days)

    Product Code
    Regulation Number
    876.5885
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    PRIME-XV FreezIS DMSO-Free MD is for use in human ex vivo tissue and cell culture processing applications.

    Device Description

    PRIME-XV Freez/S DMSO-Free MD is a liquid medium intended for use in human ex vivo tissue and cell culture processing applications.

    It is a chemically defined cryogenic preservation solution for human cells for use in a professional Healthcare Facility that performs cell culture and cell handling. It has comparable post-thaw cell viability as solutions containing dimethyl sulfoxide (DMSO), maintains potency of stem cells throughout cryopreservation, eliminates the risk of DMSO in stem cell therapy applications, is animal componentfree, enables cell preservation at -80°C to -196°C environments and is manufactured under cGMP conditions.

    AI/ML Overview

    The provided text describes a medical device, PRIME-XV FreezIS DMSO-Free MD, which is a tissue culture medium. It presents the device's indications for use, technological characteristics, and a comparison to predicate devices, but it does not contain information about an AI-powered device or a study involving human readers or a test set to establish ground truth for performance metrics like sensitivity or specificity.

    Therefore, I cannot provide the requested information regarding acceptance criteria and performance data for an AI device. The document is a 510(k) summary for a biological/chemical product, not a software device or an AI diagnostic tool.

    The acceptance criteria provided in the document relate to the quality and performance of the tissue culture medium itself, such as:

    • High cell viability, robust cell expansion post-cryopreservation, maintenance of cell function, phenotype and differentiation potential: To demonstrate lack of potential toxicity and support of tissue/cell growth.
    • Endotoxin testing per USP <85>, mycoplasma testing per USP <63>: To demonstrate lack of endotoxin or pyrogen contamination.
    • Compliance with GMP requirements regarding aseptic processing: For validation of Aseptic Processing and Sterility Assurance Level (SAL).
    • Incoming raw materials are of high quality and are lot-tested for identity and purity: To demonstrate chemical purity.
    • 24-month shelf life when stored at 2 – 8 °C: Based on stability testing confirming pH, osmolality, non-cytotoxicity, and protection against microbial contamination.

    These are established through laboratory testing directly on the medium and its interaction with cells, not through studies involving expert readers or ground truth adjudication as would be relevant for an AI diagnostic device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 7