Search Filters

Search Results

Found 5 results

510(k) Data Aggregation

    K Number
    K251302

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-12-15

    (231 days)

    Product Code
    Regulation Number
    888.3085
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The OptiMesh Multiplanar Expandable Interbody Fusion System is indicated for use as an adjunct to fusion in an intervertebral body fusion at one level in the lumbar spine from L2 to S1 in skeletally mature patients with degenerative disc disease (DDD) with up to Grade I spondylolisthesis at the involved level. DDD is defined as discogenic back pain with degeneration of the disc confirmed by patient history, physical examination, and radiographic studies. Eligible patients shall have undergone six (6) months of conservative (non-operative) care. The OptiMesh device, along with a bone void filler as cleared by FDA for use in intervertebral body fusion to facilitate fusion, is intended for use with supplemental posterior fixation systems intended for use in the lumbar spine.

    Device Description

    The OptiMesh Multiplanar Expandable Interbody Fusion System is an intervertebral body graft containment device that is a non-rigid, implanted spinal device designed to contain FDA cleared bone void filler within its internal cavity. The device is inserted into the intervertebral body space of the spine and is intended as an adjunct to intervertebral body fusion.

    The OptiMesh implants are available with and without HAnano Surface®, a 20 – 40 nanometer thin hydroxyapatite (HA) surfaces treatment.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K230927

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-11-01

    (212 days)

    Product Code
    Regulation Number
    888.3085
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The OptiMesh Multiplanar Expandable Interbody Fusion System is indicated for use as an adjunct to fusion in an intervertebral body fusion at one level in the lumbar spine from L2 to S1 in skeletally mature patients with degenerative disc disease (DDD) with up to Grade I spondylolisthesis at the involved level. DDD is defined as discogenic back pain with degeneration of the disc confirmed by patient history, physical examination, and radios. Eligible patients shall have undergone six (6) months of conservative (non-operative) care. The OptiMesh device with compatible allograft, or a bone void filler as cleared by FDA for use in intervertebral body fusion to facilitate fusion, is intended for use with supplemental posterior fixation systems intended for use in the lumbar spine.

    AFT is intended for use as a bone void filler in the extremities, spine, intervertebral disc space, and pelvis for voids or gaps that are not intrinsic to the stability of the bony structure. AFT is indicated for use in the treatment of osseous defects caused by surgery or traumatic injury. When used in intervertebral body fusion procedures, AFT must be used on its own with an intervertebral body graff containment device cleared by FDA for use with a bone void filler.

    Device Description

    The OptiMesh Multiplanar Expandable Interbody Fusion System is an intervertebral body graft containment device that is a non-rigid, implanted spinal device that is designed to contain bone graft within its internal cavity. The device is inserted into the intervertebral body space of the spine and is intended as an adjunct to intervertebral body fusion.

    AFT Allograft Filler Tube is composed of human demineralized bone matrix, human nondemineralized bone, and sodium hyaluronate. All components of AFT are resorbable. AFT is aseptically processed and provided pre-loaded into a disposable delivery tube.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the "OptiMesh Multiplanar Expandable Interbody Fusion System" with the addition of "AFT Allograft Filler Tube" as a compatible allograft. It outlines the purpose of the submission, device descriptions, indications for use, technological characteristics, and non-clinical/clinical testing. However, the document does not provide specific acceptance criteria or detailed study results in the format requested.

    The FDA 510(k) clearance process focuses on demonstrating "substantial equivalence" to a legally marketed predicate device, rather than proving a device meets specific, quantifiable acceptance criteria with a detailed study report. The non-clinical and clinical data presented here are used to support this claim of substantial equivalence.

    Based on the provided text, I can infer some aspects and highlight what is not present:

    Inferred Information:

    • Acceptance Criteria (Implied): The implied acceptance criteria revolve around demonstrating that the OptiMesh device with AFT performs comparably to the predicate device and the reference devices in terms of mechanical performance and biological impact, without introducing new safety or effectiveness concerns. This means that:
      • Mechanical performance of OptiMesh + AFT should be "as intended" and comparable to the reference device and ISO 23089-2 data.
      • Biological impact of AFT should be comparable to the reference bone graft.
      • Biocompatibility, pyrogenicity/endotoxin, sterilization, packaging, and shelf-life should be acceptable and comparable.
      • The risk profile should not be altered, and new safety/effectiveness issues should not arise.
    • Study Proving Acceptance Criteria: The study used to demonstrate this is primarily a critical engineering and clinical comparison to a bone graft used in a prospective, multi-center, non-randomized, FDA and IRB approved performance goal clinical investigation.

    Information NOT present explicitly in the document:

    • Specific quantifications of acceptance criteria.
    • A table of acceptance criteria and reported device performance with numerical values.
    • Sample sizes used for the test set (e.g., number of patients/data points in the clinical investigation for comparison).
    • Data provenance (country of origin, retrospective/prospective for the comparison study). While it mentions a "prospective" clinical investigation for the reference bone graft, it doesn't specify if the comparison itself involved new prospective data or a retrospective analysis of the existing investigation's data.
    • Number of experts used to establish ground truth or their qualifications.
    • Adjudication method for the test set.
    • MRMC comparative effectiveness study details (effect size, human reader improvement). This type of study is more common for diagnostic imaging AI than for interbody fusion systems.
    • Standalone algorithm performance (algorithm only without human-in-the-loop). This is a physical device, so "standalone algorithm performance" is not applicable in the typical AI/software sense.
    • Type of ground truth used (pathology, outcomes data, etc.) beyond "clinical data" and "performance goal clinical investigation."
    • Sample size for the training set. There's no mention of a "training set" in the context of an AI/machine learning model. This submission is for a physical medical device.
    • How the ground truth for the training set was established. (Not applicable for this type of device submission).

    Given these limitations, here is the best possible answer based only on the provided text, heavily inferring the "acceptance criteria" based on the substantial equivalence claims:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Implied from Substantial Equivalence)Reported Device Performance (Summary from Submission)
    Mechanical Function and Performance: Device with AFT performs "as intended" and comparably to reference device and ISO 23089-2 mechanical performance data."Benchtop mechanical ASTM testing and comparison confirmed that the OptiMesh device with AFT performs as intended in comparison to the reference device and ISO 23089-2 mechanical performance data." (Specific numerical performance values not provided).
    Biological Impact: AFT's impact on bone biology is comparable to the reference bone graft."A critical comparison between AFT bone void filler and the reference bone graft and its impact on bone biology was conducted and assessed." (Specific comparative biological data not provided).
    Biocompatibility, Pyrogenicity/Endotoxin, Sterilization, Packaging, Shelf-life: These aspects are acceptable and comparable to the predicate/reference devices."Biocompatibility, pyrogenicity / endotoxin monitoring, sterilization, packaging, and shelf-life were compared and assessed." (Specific details of these assessments and their outcomes, other than "compared and assessed," are not provided).
    Risk Profile: No alteration of the risk profile; no new issues of safety or effectiveness compared to the predicate device."A risk assessment was performed and confirmed that the OptiMesh device with AFT does not alter the risk profile for the device or present new issues of safety or effectiveness when compared to the predicate device." (Details of the risk assessment and specific findings not provided).
    Clinical Performance & Safety: Performance and safety of OptiMesh with AFT are supported by clinical data demonstrating equivalence to a historically studied bone graft."Clinical data has been utilized to demonstrate the performance and safety of the addition of AFT as a compatible allograft for use with the OptiMesh Multiplanar Interbody Fusion System. The clinical data includes evaluation through a critical engineering and clinical comparison to a bone graft that was used in a prospective, multi-center, non-randomized, FDA and IRB approved performance goal clinical investigation." (Specific clinical outcomes not provided).

    2. Sample size used for the test set and data provenance:
    * Sample Size: Not specified in the given text.
    * Data Provenance: The clinical data for comparison comes from a "prospective, multi-center, non-randomized, FDA and IRB approved performance goal clinical investigation" involving a reference bone graft. The country of origin is not specified but it's an FDA-approved study, implying it was likely conducted in the US or under FDA oversight for data acceptability.

    3. Number of experts used to establish the ground truth for the test set and their qualifications:
    * Not specified. The clinical investigation mentioned for comparison would have medical professionals involved, but the text does not detail the "ground truth" establishment process by experts in the context of this submission.

    4. Adjudication method for the test set:
    * Not specified.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, and its effect size:
    * No, an MRMC study is not mentioned. This type of study is typically for evaluating diagnostic imaging systems where human readers interpret medical images. This submission is for a physical interbody fusion system.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:
    * No, this concept is not applicable. The device is a physical medical implant, not an AI algorithm.

    7. The type of ground truth used:
    * The term "ground truth" is not explicitly used in the context of a dataset for algorithmic evaluation. However, for the clinical performance comparison, the "performance goal clinical investigation" likely established clinical outcomes (e.g., fusion rates, pain reduction, adverse events) as the de facto "truth" against which the subject device's performance (via comparison to a reference bone graft) was evaluated.

    8. The sample size for the training set:
    * Not applicable. This submission is for a physical medical device, not an AI/machine learning model that would require a training set.

    9. How the ground truth for the training set was established:
    * Not applicable, as there is no training set for an AI model.

    Ask a Question

    Ask a specific question about this device

    K Number
    K231781

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-10-18

    (124 days)

    Product Code
    Regulation Number
    888.3085
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The OptiMesh Multiplanar Expandable Interbody Fusion System is indicated for use as an adjunct to fusion in an intervertebral body fusion at one level in the lumbar spine from L2 to S1 in skeletally mature patients with degenerative disc disease (DDD) with up to Grade I spondylolisthesis at the involved level. DDD is defined as discogenic back pain with degeneration of the disc confirmed by patient history, physical examination, and radios. Eligible patients shall have undergone six (6) months of conservative (non-operative) care. The OptiMesh device with compatible allograft is intended for use with supplemental posterior fixation systems intended for use in the lumbar spine.

    Device Description

    The OptiMesh Multiplanar Expandable Interbody Fusion System is an intervertebral body graft containment device that is a non-rigid, implanted spinal device designed to contain bone graft within its internal cavity. The device is inserted into the intervertebral body space of the spine and is intended as an adjunct to intervertebral body fusion.

    The OptiMesh Lordotic device incorporates an asymmetrical dual chamber mesh with a larger chamber in the anterior portion of the disc space than in the posterior. Due to the asymmetry of the two mesh chambers when filled, the implant is designed to result in a lordotic shape.

    AI/ML Overview

    The provided document is a 510(k) summary for the OptiMesh Multiplanar Expandable Interbody Fusion System. This document does not describe a study involving an AI/CADe device, human readers, or a test set with ground truth established by experts.

    Instead, this document describes a medical device (an intervertebral body fusion system) and its mechanical and design properties. The non-clinical testing performed focuses on benchtop performance ASTM testing and risk assessment to demonstrate equivalence to a predicate device.

    Therefore, I cannot provide the requested information, such as acceptance criteria for AI performance, sample sizes for test/training sets, expert qualifications, or adjudication methods, as these concepts are not applicable to the information presented in this 510(k) summary.

    In summary, the provided document does not contain information about an AI/CADe device study to fulfill the prompt's requirements.

    Ask a Question

    Ask a specific question about this device

    K Number
    K033953

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2004-07-06

    (197 days)

    Product Code
    Regulation Number
    878.3300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    OptiMesh 500E is intended for use as a cement restrictor in orthopedic surgeries such as those involving the femoral canal or tibial plateau in hip stem and total knee replacement.

    OptiMesh 500E is not intended for use in spinal indications.

    Device Description

    OptiMesh 500E is an implantable PET device indicated for use as a cement restrictor in the femur and tibia. OptiMesh 500E is manufactured from polyethylene terephthalate (PET). The device is provided pre-loaded, for ease of handling, on a disposable holder made of stainless steel. The device is available in a variety of different sizes to suit the individual pathology and anatomical conditions of the patient.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a medical device called OptiMesh 500E Cement Restrictor. This document establishes that the device is substantially equivalent to legally marketed predicate devices. However, it does not include information about specific acceptance criteria and a study proving those criteria are met in the way typically found for AI/ML-based devices with quantitative performance metrics.

    The document is for a physical medical device (cement restrictor) and its clearance is based on substantial equivalence to existing predicate devices, not on meeting specific performance acceptance criteria from a clinical study with quantitative outcomes.

    Therefore, the requested information elements related to AI/ML device performance (like sample size for test set, provenance, expert qualifications, adjudication methods, MRMC studies, standalone performance, ground truth establishment, and training set details) are not applicable to this type of device submission as described in the provided text.

    Here's an analysis of what is available:

    1. A table of acceptance criteria and the reported device performance

    • Acceptance Criteria: The primary "acceptance criterion" for this type of device, as per the document, is demonstrating substantial equivalence to existing predicate devices in terms of intended use, technological characteristics, and safety and effectiveness.
    • Reported Device Performance: Instead of performance metrics from a clinical study, the "performance" demonstrated is that the device is identical in materials and similar in configuration and principles of use to predicate devices. Configurational differences were addressed through testing, which found "no new questions of safety or effectiveness."
    Acceptance Criteria (Implied by Substantial Equivalence)Reported Device Performance (Summary)
    Intended Use Equivalence to Predicate DevicesOptiMesh 500E intended use is equivalent to the intended use for other bone cement restrictors (e.g., in orthopedic surgeries such as those involving the femoral canal or tibial plateau in hip stem and total knee replacement).
    Material Equivalence to Predicate Devices (specifically OptiMesh)The OptiMesh 500E material is identical to the previously cleared OptiMesh device material (Polyethylene terephthalate - PET).
    Similar Configuration and Principles of Use to Predicate DevicesOptiMesh 500E is similar in configuration and principles of use to other devices used to contain orthopedic reconstruction materials.
    No New Questions of Safety or Effectiveness compared to Predicate Devices (after testing)Configurational differences between OptiMesh 500E and predicate devices were addressed through testing. The testing resulted in "no new questions of safety or effectiveness for a bone cement restrictor." (Specific test details are not provided in this summary).

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Not applicable. This is a physical device submission focused on substantial equivalence through material and design comparison, supported by internal testing (not clinical trials with human participant test sets).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. Ground truth as typically defined for AI/ML models is not relevant here.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not applicable. This is not an AI-assisted device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable. This is a physical device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • For this type of device, the "ground truth" would be related to engineering specifications, material properties, and mechanical performance demonstrated through non-clinical testing, rather than clinical outcomes or diagnostic accuracy. The text indicates "configurational differences... were addressed through testing," which implies mechanical or bench testing.

    8. The sample size for the training set

    • Not applicable. This is not an AI/ML device that requires training data in that sense.

    9. How the ground truth for the training set was established

    • Not applicable.

    In summary, the provided document relates to a traditional medical device (cement restrictor) seeking 510(k) clearance based on demonstrating substantial equivalence to already cleared predicate devices. The study that "proves" the device meets acceptance criteria primarily involves bench testing and comparison to predicate device specifications rather than clinical study data and performance metrics typically associated with AI/ML or efficacy trials.

    Ask a Question

    Ask a specific question about this device

    K Number
    K014200

    Validate with FDA (Live)

    Device Name
    OPTIMESH
    Manufacturer
    Date Cleared
    2003-11-26

    (705 days)

    Product Code
    Regulation Number
    878.3300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    OptiMesh is intended to maintain the relative position of bone graft material (such as autograft or allograft) within a vertebral body defect (e.g. tumor) that does not impact the stability of the vertebral body and does not include the vertebral endplates.

    Device Description

    OptiMcsh is a sterile, three-dimensional surgical mesh container made of knitted polyester yarn and offered in a range of sizes. The device is packaged in double Tyvek/Mylar pouches and a cardboard carton, and terminally sterilized.

    AI/ML Overview

    The provided document is a 510(k) premarket notification letter and summary for a surgical mesh device called OptiMesh. It does not contain the acceptance criteria or a study proving the device meets acceptance criteria in the way typically expected for an AI/ML device (e.g., performance metrics like sensitivity, specificity, accuracy against a ground truth).

    Instead, this document is focused on establishing substantial equivalence to a predicate device based on intended use, materials, and configuration. The "performance data" mentioned in the "Technological Characteristic Comparisons" section likely refers to bench testing or material property tests to show the device's physical properties are safe and effective for its intended mechanical function, not a clinical performance study with human subjects or AI-driven analysis.

    Therefore, most of the requested information cannot be extracted from this document, as it pertains to a different type of device evaluation.

    However, I can provide what is available or infer from the document:

    1. A table of acceptance criteria and the reported device performance

    The document does not specify quantitative acceptance criteria or reported device performance in terms of clinical outcomes (e.g., success rates, complication rates) or AI-specific metrics (e.g., accuracy, sensitivity). The "acceptance" in this context refers to the FDA finding of substantial equivalence.

    Criteria (Implied)Reported Performance (Implied from Substantial Equivalence)
    Substantially equivalent to predicate in intended useYes, for maintaining bone graft material in a vertebral body defect.
    Substantially equivalent to predicate in materialsYes, polyester yarn for mesh, similar to predicate.
    Substantially equivalent to predicate in configurationYes, 3D surgical mesh container.
    No new concerns about safety or effectivenessPerformance data provided to demonstrate this (details not included).

    2. Sample size used for the test set and the data provenance

    No clinical test set or data provenance is detailed in this document. The evaluation is based on technological characteristics comparison to predicate devices, not human subject data for performance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable, as no clinical test set or ground truth derived from expert review is described.

    4. Adjudication method for the test set

    Not applicable.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done

    No, this type of study is not mentioned as this device is a surgical mesh, not a diagnostic or AI-assisted interpretation device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable, as this is a physical medical device (surgical mesh), not software/AI.

    7. The type of ground truth used

    For the purpose of substantial equivalence, the "ground truth" is established by the predicate device's characteristics and its prior regulatory approval. The safety and effectiveness of the predicate device implicitly serves as the benchmark.

    8. The sample size for the training set

    Not applicable, as this is not an AI/ML device requiring a training set.

    9. How the ground truth for the training set was established

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1