Search Filters

Search Results

Found 3 results

510(k) Data Aggregation

    K Number
    K222070

    Validate with FDA (Live)

    Device Name
    EndoNaut
    Manufacturer
    Date Cleared
    2022-10-25

    (103 days)

    Product Code
    Regulation Number
    892.1650
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EndoNaut is an image fusion software solution and computerized navigational system intended to assist X-ray fluoroscopy-guided procedures in the positioning of surgical instruments and endovascular devices.

    EndoNaut is indicated for use by Physicians for patients undergoing a fluoroscopy X-ray guided procedure in the chest, abdomen, pelvis, neck and lower limbs, such as aneurysm repair, artery/vein embolization, or peripheral artery disease treatment.

    The information provided by the software or system is in no way intended to substitute for, in whole or in part, the surgeon's judgment and analysis of the patient's condition.

    It is mandatory to check the real-time anatomy with a suitable imaging technique, such as a contrast-enhanced angiography, before deploying any invasive medical device.

    Device Description

    EndoNaut is a computerized navigation system consisting of a software part that carries the medical features and technologies that are controlled and can be installed on a hardware part that enables the medical device to be used in accordance with its intended purpose.

    EndoNaut is intended to assist X-ray fluoroscopy-guided procedures in the positioning of surgical instruments and endovascular devices.

    EndoNaut Software parts are supported by hardware and software accessories which enable image display and an interaction with the user.

    The Software part is interoperable with EndoSize which is a standalone Software designed and developed by Therenva to enable case planning strategy and device (endoprosthesis) selection be-fore endovascular procedure. EndoSize is used by practitioners (in the preparation phase of the operating procedure) or by endoprosthesis manufacturers to visualize vascular structures and/or carry out an extract of the vascular structure from the preoperative CT scan. EndoSize is medical device software which obtained a substantial equivalence determination and FDA clearance through the CDRH premarket notification process (510(K)) (NºK160376).

    AI/ML Overview

    The provided text is a 510(k) Summary for the medical device EndoNaut. It details the device, its intended use, and a comparison to a predicate device to establish substantial equivalence. However, it does not contain information about a specific study proving the device meets acceptance criteria related to its performance in terms of AI model accuracy, such as sensitivity, specificity, or reader study outcomes.

    The document primarily focuses on demonstrating that the new version of EndoNaut (Subject Device) has similar intended use, functionalities, and safety/effectiveness profiles as its previously cleared predicate device (Predicate Device [K212383](https://510k.innolitics.com/device/K212383)), despite some architectural changes (e.g., from standalone software to a server/client model). It emphasizes design verification and validation activities rather than clinical performance studies for AI accuracy.

    Here's a breakdown of why the requested information cannot be fully extracted and what can be inferred:


    Unable to provide a table of acceptance criteria and reported device performance related to AI model accuracy. The document states:

    • "The subject of this premarket submission did not require clinical studies to support equivalence." (Page 17)
    • It mentions "Verification and validation activities have demonstrated that the EndoNaut (Server) software variant performs equally as the EndoNaut (Standalone) predicate software by providing reliable results, without functional regression and moreover, offers robust safety/security mechanisms." (Page 18)
    • It refers to "Features which call machine-learning algorithms: Registration 3D/2D Motion detection Contrast injection detection" (Page 6). It states that "[t]he algorithms have not been changed. Only the way they are implemented is different... These implementation changes do not change the purpose of the algorithms (they do what they did before)." (Page 6)

    This implies that the "performance" validated was primarily related to the continued functionality and safety of the existing algorithms within the new architecture, rather than a re-evaluation of their diagnostic accuracy or impact on human performance in a clinical setting. Thus, there are no specific accuracy metrics (e.g., sensitivity, specificity, AUC) or reader study results reported for the device in this document.


    Based on the provided text, the following information is either explicitly stated, can be inferred, or is explicitly absent:

    1. A table of acceptance criteria and the reported device performance:

      • Acceptance Criteria for AI Performance (e.g., sensitivity, specificity): Not provided in the document. The submission focuses on substantial equivalence to a predicate device and verification of existing algorithms within a new architecture, rather than establishing new performance benchmarks for AI accuracy.
      • Reported Device Performance: No quantitative performance metrics (e.g., sensitivity, specificity, accuracy, AUC) related to the AI algorithms' diagnostic capabilities are reported. The performance discussion centers on "functional regression" checks and demonstrating "reliable results" and "robust safety/security mechanisms" for the software change (Page 18).
    2. Sample size used for the test set and the data provenance: Not specified in the context of AI performance evaluation. The document mentions "Simulated use testing (Validation)" (Page 18) but does not detail the dataset used, its size, or provenance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not specified. As no clinical studies or specific accuracy evaluations are detailed, the ground truth establishment for such performance metrics is not discussed.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set: Not specified.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not done/reported. The document explicitly states: "The subject of this premarket submission did not require clinical studies to support equivalence." (Page 17).

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not explicitly detailed with performance metrics. The document confirms the presence of machine learning algorithms for "Registration 3D/2D, Motion detection, Contrast injection detection" and states that "The algorithms have not been changed. Only the way they are implemented is different... These implementation changes do not change the purpose of the algorithms (they do what they did before)." (Page 6). This suggests that the algorithms themselves were part of the predicate device and their function was maintained, but a formal standalone performance study for this specific submission is not presented. The verification activities might have included internal functional testing of these algorithms.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not specified regarding the AI features. For the general functionality, the "ground truth" would be the expected behavior and output based on design specifications and the predicate device's performance.

    8. The sample size for the training set: Not specified. The document states that the machine learning algorithms "have not been changed" from the predicate device (Page 6), implying that any training would have occurred for the predicate device, but details are not provided here.

    9. How the ground truth for the training set was established: Not specified.


    Summary based on the document:

    This 510(k) submission for EndoNaut (K222070) is primarily concerned with demonstrating substantial equivalence to a previously cleared predicate device (EndoNaut K212383) following changes in software architecture and minor hardware updates. It relies on:

    • Design verification and validation (V&V) activities: These include risk assessments, usability reviews, requirement reviews, design reviews, clinical evaluation report reviews, testing on unit level, integration testing, interoperability testing, performance testing, safety testing, and simulated use testing (Page 18).
    • No new clinical studies: The submission explicitly states that clinical studies were not required to support equivalence (Page 17).
    • Consistency of AI algorithms: The document clarifies that the underlying machine learning algorithms for features like 3D/2D registration, motion detection, and contrast injection detection have not been changed but their implementation differs due to the new software architecture. The validation activities focused on ensuring these algorithms perform "equally as the EndoNaut (Standalone) predicate software" (Page 18) without "functional regression" and maintaining safety and security.

    Therefore, the document does not provide the detailed acceptance criteria or performance study results typically associated with AI model accuracy (e.g., sensitivity, specificity, reader studies) for a new AI function or a significant modification that would necessitate re-evaluation of diagnostic performance. Instead, it attests to the maintained functionality and safety of existing features within an updated system.

    Ask a Question

    Ask a specific question about this device

    K Number
    K212383

    Validate with FDA (Live)

    Device Name
    EndoNaut
    Manufacturer
    Date Cleared
    2021-08-31

    (29 days)

    Product Code
    Regulation Number
    892.1650
    Age Range
    0 - 21
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EndoNaut is indicated for the treatment of patients with endovascular diseases and who needs, such as but not limited to the following examples:

    • · endovascular aortic aneurysm repair (AAA and TAA),
    • · angioplasty,
    • · stenting.
    • · embolization in iliac arteries and corresponding veins.
      EndoNaut is indicated for endovascular procedures in the thorax, abdomen, pelvis and lower limbs.
    Device Description

    EndoNaut system is an imaging solution for intraoperative navigation and guidance tool for endovascular procedures (aorto-iliac and peripheral).
    EndoNaut provides localization assistance by combining 3D preoperative scans and 2D intra-operative fluoroscopy imagery to help position guides, catheters and other vascular devices.
    EndoNaut Software is interoperable with EndoSize which is a standalone Software designed and developed by Therenva to enable case planning strategy and device (endoprosthesis) selection before endovascular procedure.

    AI/ML Overview

    The provided document is a 510(k) summary for a modified medical device, EndoNaut, and focuses on demonstrating substantial equivalence to a predicate device (also named EndoNaut, K171829). It does not contain detailed acceptance criteria, device performance metrics, or study design information typically found in a clinical study report for proving device effectiveness.

    The document primarily outlines minor changes in hardware components and software naming conventions, and reaffirms compliance with relevant standards. It explicitly states that "No new risks or possible errors were detected or identified. New clinical data were not necessary."

    Therefore, I cannot provide detailed acceptance criteria or a study that proves the device meets specific acceptance criteria in the way you requested. The document does not describe such a study.

    However, I can extract the information related to the device's validation and verification activities, which are general statements of compliance rather than specific performance metrics against pre-defined acceptance criteria.


    Based on the provided document, here's what can be extracted regarding acceptance criteria and "study" (referring to verification and validation activities):

    The document does not detail specific, quantitative acceptance criteria for device performance. Instead, it relies on demonstrating that the modified device (EndoNaut, subject device) is substantially equivalent to the predicate device (EndoNaut, K171829) and continues to meet general safety and effectiveness requirements. The "study" in this context refers to the design verification and validation activities conducted as part of the quality assurance system.

    1. A table of acceptance criteria and the reported device performance

    No specific, quantitative acceptance criteria are provided in the document, nor are specific performance metrics reported against such criteria. The document states "These tests showed that the EndoNaut Workstation TS1CA2DS1-2 meets the design specification and performed as intended." The "acceptance criteria" are implied to be conformance with "design specification" and "performed as intended," as well as compliance with various standards.

    Acceptance Criterion (Implied)Reported Device Performance
    Conforms to Design SpecificationsMeets design specifications and performs as intended.
    Safe and EffectiveDeemed safe and effective (based on substantial equivalence).
    ISO 14971 complianceApplied
    IEC 62304 complianceApplied
    IEC 62366 complianceApplied
    IEC 60601-1 compliance (Workstation)Yes (for CENELEC countries)
    ANSI AAMI ES60601-1 (Workstation)Yes (for US deviations to IEC 60601-1)
    IEC 60601-2 compliance (Workstation)Yes
    IEC 60601-1-6 compliance (Workstation)Yes

    2. Sample size used for the test set and the data provenance

    The document does not specify a "test set" and thus no sample size for such a set. The validation and verification activities are generally performed internally without a distinct "test set" from real patient data in the context of a 510(k) for minor modifications. The document does not provide a sample size or data provenance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    The document does not describe a clinical study involving experts establishing ground truth. Therefore, this information is not available.

    4. Adjudication method for the test set

    Not applicable, as no external test set or adjudication process is described in the provided document.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    The document does not describe an MRMC study or any study evaluating human reader improvement with AI assistance. The device is described as an "imaging solution for intraoperative navigation and guidance tool," and the AI module mentioned pertains to 2D-3D fusion and semi-automatic registration, not diagnostic interpretation by human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The document does not explicitly state an "algorithm only" standalone performance study. The device is intended for "intraoperative navigation and guidance," implying human-in-the-loop use. The "Performance testing (Verification)" and "Simulated use testing (Validation)" would cover the device's functional integrity, but no details on standalone performance metrics are provided.

    7. The type of ground truth used

    The document does not mention specific "ground truth" data used for performance evaluation in the context of clinical accuracy (e.g., pathology, outcomes data). The verification and validation activities likely used internal reference standards and simulated use cases to confirm the device's functional performance and safety.

    8. The sample size for the training set

    Not applicable. The document is for a 510(k) submission for a modified device, primarily addressing hardware and software updates, and reaffirming substantial equivalence. It does not describe the development or training of an AI model, only mentions an "AI module" in the context of 2D-3D fusion and registration. Therefore, no training set size is provided.

    9. How the ground truth for the training set was established

    Not applicable, as no training set is described.

    Ask a Question

    Ask a specific question about this device

    K Number
    K171829

    Validate with FDA (Live)

    Device Name
    EndoNaut
    Manufacturer
    Date Cleared
    2017-09-21

    (93 days)

    Product Code
    Regulation Number
    892.1650
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EndoNaut provides image guidance by overlaying preoperative 3D vessel anatomy onto live fluoroscopic images in order to assist in the positioning of the guidewires, catheters and other endovascular devices.

    EndoNaut is intended to assist endovascular procedures in the thorax, abdomen, neck, pelvis and lower limbs. Suitable procedures include (but not limited to) endovascular aortic aneurysm repair (AAA and TAA), angioplasty, stenting and embolization in iliac arteries and corresponding veins.

    EndoNaut is not intended for use in the X-ray guided procedures in the liver, kidneys or pelvic organs.

    Device Description

    EndoNaut is a stand-alone software medical device that runs on a Windows based computer that meets the minimum requirements.

    EndoNaut software provides navigation tools for image-guided endovascular surgery. The device enables to register the X-ray intra-operative images and the pre-operative data.

    The device is operated by the physician or a trained operator. The client machine captures a live fluoroscopy video feed from the X-ray's machine external video port, either in digital or in analog format. Any machine that meets the hardware and software requirements can be supported.

    The EndoNaut will be marketed as a software only solution.

    AI/ML Overview

    Below is a summary of the acceptance criteria and study information for the EndoNaut device, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    Performance MetricAcceptance CriteriaReported Device Performance
    Registration AccuracyRegistration error less than 3mmResults meet the acceptance criteria
    Panorama Creation ErrorMaximum acceptable error of 10mm for peripheral artery surgeryMean errors below the acceptance criteria
    Measuring Functions (Distance)No error for distance measurement along centerline (compared to planning tool)Results meet the acceptance criteria
    Measuring Functions (Length on Image)Max error 1mm for length measurements on images (compared to visible rule)Results meet the acceptance criteria
    Software ComplianceCompliance with ISO 14971, IEC 62304, IEC 62366, and FDA Guidance for Software Contained in Medical DevicesSoftware verification and validation testing performed, demonstrating compliance with these standards and usability testing with clinical users.
    Clinical FeasibilityFeasibility of fusion imaging during aortic endovascular procedures (Primary Endpoint)Clinical study conclusion confirms the device is safe and effective and supports the indications for use, implying feasibility was achieved. (Specific percentage not provided)
    Clinical EfficiencyEvaluation of efficiency in deploying infrarenal aortic stent grafts to treat unruptured atheromatous aneurysms (Secondary Endpoint: radiation dose)Clinical study conclusion confirms the device is safe and effective and supports the indications for use. (Specific improvement in radiation dose not provided, but implies efficiency was found acceptable)

    2. Sample Sizes and Data Provenance

    • Test Set (for Technical Performance - Registration Accuracy):

      • Sample Size: 5000 different registrations on 100 pre-operative CT-scan images from 50 patients.
      • Data Provenance: Not explicitly stated (e.g., country of origin). Appears to be retrospective, using existing CT-scan images.
    • Test Set (for Technical Performance - Panorama Creation):

      • Sample Size: 7 cases (6 patients and 1 phantom).
      • Data Provenance: Not explicitly stated. The use of "in-vivo data" suggests patient data, likely retrospective or collected specifically for this purpose.
    • Test Set (for Clinical Study):

      • Sample Size: Not explicitly stated, though it is described as a "single-centre, prospective feasibility pilot study."
      • Data Provenance: Prospective, single-center study. Location not specified.

    3. Number of Experts and Qualifications for Ground Truth (Test Set)

    • Technical Performance (Registration Accuracy): Not applicable. The ground truth was a "gold standard transformation matrix," which suggests a numerically derived or calculated reference, not directly established by human experts in this context.
    • Technical Performance (Panorama Creation): One "perfect panorama (manually corrected)" was used as ground truth. No specific number or qualifications of the individual who manually corrected it are provided.
    • Clinical Study: Not applicable for establishing ground truth of the device's performance. The clinical endpoints (feasibility, radiation dose) are objective measures.

    4. Adjudication Method for the Test Set

    • Technical Performance: Not applicable as the ground truth was either a numerical matrix or a manually corrected panorama, without a listed multi-reader adjudication process.
    • Clinical Study: No explicit adjudication method for clinical endpoints (e.g., disagreement resolution for radiation dose measurements) is described.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No MRMC comparative effectiveness study is mentioned, nor is there any information about the effect size of human readers improving with AI vs. without AI assistance. The clinical study focused on feasibility and efficiency of the device itself.

    6. Standalone Performance

    • Yes, performance evaluations were conducted for the algorithm in a standalone manner. The technical performance tests (registration accuracy, panorama creation, measuring functions) demonstrate the algorithm's capabilities without direct human interaction beyond setting up the test scenarios. The device itself is described as a "stand-alone software medical device."

    7. Type of Ground Truth Used

    • Technical Performance (Registration Accuracy): "Gold standard transformation matrix."
    • Technical Performance (Panorama Creation): "Perfect panorama (manually corrected)."
    • Technical Performance (Measuring Functions): Comparison with measurements from "EndoSize (planning tool)" and "a visible rule on the fluoroscopic image."
    • Clinical Study: Clinical endpoints such as "feasibility rate of fusion" and "radiation dose as measured by fluoroscopy time, dose-area product and air kerma" were used as measures of outcome.

    8. Sample Size for the Training Set

    • The document does not explicitly state the sample size for any training set. The performance data section describes testing on CT-scan images and patient cases but does not distinguish between training and test data or provide details on the training methodology.

    9. How the Ground Truth for the Training Set Was Established

    • Since no information about a distinctive training set or its sample size is provided, there is no description of how ground truth for a training set was established.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1