    K Number
    K201653

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-11-27

    (162 days)

    Product Code
    Regulation Number
    890.5850
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EMS: The Compex Sport Elite 3.0 is intended to stimulate healthy muscles in order to improve or facilitate muscle performance. The work imposed on the Compex Sport Elite 3.0 programs is not suitable for relabilitation or physiotherapy.

    TENS: The Compex Sport Elite TENS is intended for:

    • Temporary relief of pain associated with sore and aching muscles due to strain from exercise or normal household and work activities:

    • The symptomatic relief and management of chronic, intractable pain and relief of pain associated with arthritis.

    The Compex Sport Elite 3.0 is an Over-the-Counter device to be used by adults only.

    Device Description

    The Compex Sport Elite 3.0 is an electrical stimulation device, which stimulates healthy muscles by means of electrical impulses transmitted by electrodes. The electrical pulses generated by the Compex Sport Elite 3.0 stimulates motor nerves to stimulate a muscular response. Depending on the parameters of theelectrical impulses (pulse frequency. duration of contraction, duration of rest, and totalsession duration). different types of muscle work can be imposed on the stimulated muscles. The Compex Sport Elite 3.0 may therefore be considered a technique of muscletraining.

    TENS (Transcutaneous Electrical Nerve Stimulation) and NMES (NeuroMuscular Electrical Stimulation) target different nerve groups of the body. TENS specifically targets the sensory nerves, which are responsible for sending pain signals to the brain. NMES targets the muscle itself, specifically through the motor nerves. This allows the NMES machine to create a muscle contraction to recruit more muscle fibers when training; warming up or recovering.

    The Compex Sport Elite 3.0 system consists of these components:

    • 1x Stimulator
    • 1x Lead WireSet
    • 2x Small Performance Snap Electrodepackages ●
    • 2x Large Performance Snap Electrodepackages
    • 1x Charging Cable ●
    • 1x Carrying Case ●

    These components are packaged together in a carrying case along with the user guide and a battery charger.

    The electrodes are supplied by Axelgaard Mfg. Co., Inc. and cleared under K130987.

    The stimulator is a microprocessor controlled 4-channel electro-stimulator. The stimulator drives each output channel independently based upon the parameters predefined for a program selected by the user operates the device through a User Interface (UI) consisting of a graphic LCD, keypad controls and supporting software. The User Interface is made up of different menus that allow the following functions: set up the device (Options Menu), select a desired category (Category Menu), select a preset program (Treatments ) Menu), tune a selected program (Stimulation Menu), andadiust the stimulation intensities (Level Menu).

    AI/ML Overview

    The provided document is a 510(k) summary for a medical device, the Compex® Sport Elite 3.0. This type of submission to the FDA focuses on demonstrating substantial equivalence to a legally marketed predicate device, rather than proving de novo safety and effectiveness through extensive clinical trials. Thus, the information requested in your prompt regarding acceptance criteria, sample sizes, expert ground truth, MRMC studies, standalone performance, and training set details for AI/ML-based devices is not applicable to this specific document.

    The document primarily addresses acceptance criteria in the context of non-clinical testing and comparison to the predicate device. The study proving the device meets these "acceptance criteria" is a demonstration of substantial equivalence rather than a clinical performance study.

    Here's an analysis of the provided information within the context of a 510(k) submission, addressing the questions where applicable:


    1. A table of acceptance criteria and the reported device performance:

    The document doesn't present "acceptance criteria" in the traditional sense of a performance study with specific numerical thresholds for accuracy, sensitivity, or specificity for an AI/ML device. Instead, the acceptance criteria are implicitly defined by the safety and performance standards the device was tested against and by its substantial equivalence to the predicate device.

    The document provides a "Comparison Analysis" (Table 1: Characteristics, Table 2: Output Specifications, Table 3: Software Comparison Analysis) between the subject device (Compex® Sport Elite 3.0) and its predicate device (Compex Sport Elite, K170918). This comparison itself serves as the "reported device performance" against the "acceptance criteria" of being substantially equivalent to the predicate and meeting relevant safety standards.

    Table 1: Comparison Analysis - Characteristics (Excerpt)

    NoCharacteristicPredicate DeviceSubject DeviceSame/Similar/DifferentRisk Analysis (HAZ-PRO-130)
    1Electrodes connection[Description][Description]SameNo additional risk.
    2Power SourceRechargeable Ni-MH battery 4.8V (4 cells AA=R6); replaceable.Rechargeable Li-ion battery 3.7V (one cell); not replaceable.DifferentSmaller size; reduced weight. User will not handle battery. The battery conforms to IEC 62133-2 and UN DOT 38.3. No additional risk.
    ..................
    24Ingress ProtectionIP20IP22DifferentIP22 is required by IEC 60601-1-11. Reduced risk.
    ..................

    Table 2: Output Specifications Comparison Analysis (Excerpt)

    NoCharacteristicPredicate DeviceSubject DeviceSame/Similar/DifferentRisk analysis
    33Maximum Output Voltage (±10%)60 V @ 500 Ω, 165 V @ 2 kΩ, 165 V @ 10 kΩ60 V @ 500 Ω, 165 V @ 2 kΩ, 165 V @ 10 kΩSameNo additional risk
    35Pulse WidthNMES: 200 to 400 [µs], TENS: 70 to 300[µs]NMES: 200 to 400 [µs], TENS: 70 to 300[µs]SameNo additional risk
    ..................

    Table 3: Software Comparison Analysis (Excerpt)

    NoCharacteristicPredicate DeviceSubject DeviceSame/Similar/DifferentRisk Analysis
    41Dual MCU design[Description][Description]Different master MCU, Same protection MCUSubject device's master MCU has improved performance for control and user interface. Same protection MCU is used. No additional risk.
    47UI Screens - Placements selection screenDoes not exist, need reference to printed user guideUsing graphic display to inform user the proper location of the treatment electrode pads on a human body diagram.DifferentSubject device offers clearer usage guide. Reduced risk.
    ..................

    The "acceptance criteria" here are that the subject device performs identically or similarly to the predicate device in terms of critical functional and safety parameters, and any differences do not raise new issues of safety or effectiveness. For "Different" or "Similar" characteristics, the risk analysis justifies why these differences do not introduce new risks or even reduce existing ones (e.g., improved ingress protection).

    2. Sample sizes used for the test set and the data provenance:

    • Sample Size: Not applicable. This is a medical device (muscle stimulator), not an AI/ML diagnostic or prognostic system that processes clinical data. The "testing" refers to bench testing and comparison to a predicate, not performance on a clinical test set of patient data.
    • Data Provenance: Not applicable for clinical data. The provenance for the testing data would be from laboratory bench tests conducted by a Nationally Recognized Test Laboratory (Nemko Shanghai Ltd. Shenzhen Branch).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    Not applicable. Ground truth as in expert consensus on disease status is not relevant for this type of device and submission. The "ground truth" for the device's technical specifications and safety conformity would be the industry standards (e.g., IEC 60601 series) and the specifications of the predicate device.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    Not applicable. Adjudication methods are used in clinical studies, particularly for subjective assessments or when establishing ground truth from multiple readers. This is a technical comparison and safety conformity assessment.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    Not applicable. This device is an electrical stimulator, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Not applicable. This is not an algorithm-only device. Its function is direct physical electrical stimulation.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

    The "ground truth" for this 510(k) submission is based on:

    • International safety and performance standards: e.g., ANSI/AAMI ES60601-1, IEC 60601-1-2, IEC 60601-1-6, IEC 60601-1-11, IEC 60601-2-10, IEC 62133-2, ANSI/AAMI/IEC 62304.
    • Specifications and performance of the legally marketed predicate device (Compex Sport Elite, K170918): The core of the 510(k) submission is to demonstrate that the new device is "substantially equivalent" to this predicate.

    8. The sample size for the training set:

    Not applicable. There is no AI/ML component with a training set for this device.

    9. How the ground truth for the training set was established:

    Not applicable. There is no AI/ML component with a training set for this device.


    In summary: The provided document is an FDA 510(k) clearance letter and summary for a physical medical device (muscle stimulator). The "study that proves the device meets the acceptance criteria" refers to bench testing against recognized electrical safety and performance standards and a detailed comparison to a legally marketed predicate device to demonstrate substantial equivalence, rather than a clinical trial or performance study typical for AI/ML-driven diagnostic devices.

    Ask a Question

    Ask a specific question about this device

    K Number
    K170918

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2017-06-20

    (83 days)

    Product Code
    Regulation Number
    890.5850
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EMS: The Compex Sport Elite is intended to stimulate healthy muscles in order to improve or facilitate muscle performance. The work imposed on the muscles by the Compex is not suitable for rehable for rehabilitation or physiotherapy.

    TENS: The Compex Sport Elite TENS is intended for:

    · Temporary relief of pain associated with sore and aching muscles due to strain from exercise or normal household and work activities

    · They symptomatic relief and management of chronic, intractable pain and relief of pain associated with arthritis.

    The Compex® Sport Elite is an Over-The-Counter device to be used by adults only.

    Device Description

    The Compex® Sport Elite is an electrical stimulation device, which stimulates healthy muscles by means of electrical impulses transmitted by electrodes. The electrical pulses generated by the Compex® Sport Elite stimulate motor nerves to stimulate a muscular response. Depending on the parameters of the electrical impulses (pulse frequency, duration of contraction, duration of rest, and total session duration), different types of muscle work can be imposed on the stimulated muscles. The Compex® Sport Elite may therefore be considered a technique of muscle training.

    TENS (Transcutaneous Electrical Nerve Stimulation) and NMES (NeuroMuscular Electrical Stimulation) target different nerve groups of the body. TENS is specifically targets the sensory nerves, which are responsible for sending pain signals to the brain. NMES targets the muscle itself, specifically through the motor nerves. This allows the NMES machine to create a muscle contraction to recruit more muscle fibers when training; warming up or recovering.

    The Compex® Sport Elite system consists of these components:

    • 1x Stimulator
    • 1x Lead Wire Set
    • 2x Small Performance Snap Electrode package ●
    • 2x Large Performance Snap Electrode package
    • 1x Battery Charger ●

    These components are packaged together in a carrying case along with the user guide and a battery charger.

    The stimulator is a microprocessor controlled 4 channels electro-stimulator. The stimulator drives each output channel independently based upon the parameters pre-defined for a program selected by the user. The user operates the device through a User Interface (UI) consisting of a graphic LCD, keypad controls and supporting software. The User Interface is made up of different menus that allow the following functions: set up the device (Options Menu), select a desired category (Category Menu), select a preset program (Treatments' Menu), tune a selected program (Stimulation Menu), and adjust the stimulation intensities (Level Menu).

    AI/ML Overview

    The provided document is a 510(k) premarket notification for the Compex® Sport Elite, a powered muscle stimulator. It focuses on demonstrating substantial equivalence to predicate devices (Compex Sport Plus and Strive) rather than providing extensive clinical study data for acceptance criteria.

    Therefore, the information requested regarding a study proving acceptance criteria for device performance is largely not available in this document. The document primarily describes the technical characteristics of the new device and compares them to predicate devices, along with adherence to electrical safety, electromagnetic compatibility, software verification, and usability standards.

    Here's a breakdown of the available information based on your request:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state "acceptance criteria" for a study in numerical terms like sensitivity, specificity, or improvement effect size. Instead, it demonstrates compliance with recognized medical device standards and provides detailed comparisons of technical specifications to predicate devices. The "performance" is therefore reported in terms of these technical characteristics.

    Acceptance Criteria (Inferred/Stated)Reported Device Performance (Compex Sport Elite)
    Electrical Safety & Essential Performance (as per IEC 60601-1)Complies with IEC 60601-1
    Electromagnetic Compatibility (as per IEC 60601-1-2)Complies with IEC 60601-1-2
    Use in Home Healthcare Environment (as per IEC 60601-1-11)Complies with IEC 60601-1-11
    Performance of Nerve and Muscle Stimulators (as per IEC 60601-2-10)Complies with IEC 60601-2-10
    Software Verification (meets design requirements)Software verified in accordance with FDA guidance "General Principles of Software Validation, January 11, 2002." Demonstrated to meet design requirements. Cybersecurity vulnerability and management approach established.
    Usability/Human Factors (meets requirements, appropriate for users/environment, mitigates use-related risks)Usability/Human Factors testing performed. Demonstrated that established requirements for usability were met, and the design is appropriate for intended users and use environment. The study substantiates acceptability of use-related risks.
    Conformity with other standards (e.g., Risk Management, Software Life Cycle)Complies with ISO 14971 (Risk Management) and AAMI/ANSI /IEC 62304 (Software Life Cycle Processes).
    Technical Specifications (e.g., Waveform, Max Output Voltage/Current, Pulse Width, Frequency, Net Charge, Max Phase Charge, Max Current Density, Max Power Density)Detailed specifications are provided in the comparison tables for the new device (Compex Sport Elite) and predicate devices. For most parameters (waveform, shape, voltages, currents, pulse widths, frequencies for NMES programs), the Compex Sport Elite matches or is similar to the Compex Sport Plus. For TENS specific parameters, it aligns with or is similar to the Strive. Differences are noted but deemed not to raise safety and effectiveness questions (e.g., Compex Sport Elite has two output modes (NMES/TENS) vs. Compex Sport Plus (NMES) and Strive (TENS)). Specific values are extensive in the source document and are essentially the "reported performance" for these technical aspects.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided in the document. The performance testing described (electrical safety, EMC, software, usability) are typically internal validation tests and not clinical studies involving patient data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not provided. The "ground truth" in this context would likely be compliance with engineering standards, software requirements, and usability principles, assessed by engineers and human factors specialists rather than medical experts for clinical outcomes.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not provided. Standard engineering and software verification often involve peer reviews and structured testing, but specific adjudication methods like those used in clinical trials (e.g., 2+1 consensus) are not applicable or mentioned here.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC comparative effectiveness study was done or reported. This device is a muscle stimulator, not an AI diagnostic tool, so this type of study is not relevant to its regulatory submission.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The device is a physical muscle stimulator and does not involve AI algorithms in the way described for "standalone performance" in AI/CADe devices. Its "standalone performance" is essentially its ability to meet the technical specifications and safety standards independently. This was assessed through the electrical safety, EMC, software verification, and usability testing, as detailed above.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for this submission is compliance with:

    • Recognized consensus standards (IEC 60601-1, -1-2, -1-11, -2-10, IEC 62366, ISO 14971, AAMI/ANSI/IEC 62304).
    • Design requirements for software functionality.
    • Usability requirements for safe and effective user interaction.

    There is no mention of clinical expert consensus, pathology, or outcomes data being used as ground truth for this 510(k) submission, as the submission explicitly states: "This submission does not contain clinical data."

    8. The sample size for the training set

    This information is not applicable/not provided for this type of device and submission. The device is not an AI/machine learning model that requires a "training set."

    9. How the ground truth for the training set was established

    This information is not applicable/not provided as there is no "training set" for this device.