Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K210202

    Validate with FDA (Live)

    Device Name
    BioWaveGO RX
    Date Cleared
    2021-02-24

    (30 days)

    Product Code
    Regulation Number
    882.5890
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BioWaveGO Rx is indicated for prescription use for:

    · Symptomatic relief of chronic, intractable pain

    · Symptomatic relief of acute pain

    · As an adjunctive treatment in the management of post-surgical and post-traumatic acute pain

    Device Description

    The BioWaveGO Rx Neuromodulation Pain Therapy Device is a battery-powered device intended to provide pain relief based on the technology of parent devices BioWaveHOME. The BioWaveGO Rx device delivers the summed high frequency alternating current sinusoidal signals between electrodes, providing symptomatic relief of acute, chronic, and post-operative pain. The device is identical in design to the BioWaveGO cleared in K180943. However, this 510(k) seeks clearance of the device for prescription use. The BioWaveGO Rx has the identical battery and software to the original clearance in K180943.

    AI/ML Overview

    This FDA 510(k) summary for the BioWaveGO Rx device does not contain a typical acceptance criteria table and performance study results. Instead, it focuses on demonstrating substantial equivalence to a predicate device (BioWaveGO, K180943) through a comparison of specifications.

    The document explicitly states: "No additional testing was required for this Special 510(k)." This indicates that a new performance study with acceptance criteria was not conducted for the BioWaveGO Rx as part of this submission because it is deemed substantially equivalent in performance to its predicate. The substantial equivalence is based on the device being identical in design and indications to the predicate, with the only change being its availability for prescription use rather than over-the-counter.

    Therefore, many of the requested elements for a performance study are not applicable or cannot be extracted from this document, as a specific new performance study wasn't part of this 510(k) submission.


    Despite the lack of a dedicated performance study for this specific submission, I can present the information that is available and explain the context:

    1. Acceptance Criteria and Reported Device Performance

    As no new performance study was conducted, there are no specific acceptance criteria or reported device performance results from a new study presented in this document. The "performance" assessment is by comparison to the predicate device, asserting that its performance is equivalent due to identical design and function. The acceptance criteria, in this context, would be that the BioWaveGO Rx device demonstrates substantial equivalence to its predicate across all specified characteristics.

    The table below summarizes the comparison points that implicitly serve as "performance" metrics for substantial equivalence:

    CharacteristicAcceptance Criteria (Implied by Predicate)Reported Device Performance (BioWaveGO Rx)Outcome
    Indications for Use- Symptomatic relief of chronic, intractable pain- Symptomatic relief of acute pain- As an adjunctive treatment in the management of post-surgical and post-traumatic acute pain- Symptomatic relief of chronic, intractable pain- Symptomatic relief of acute pain- As an adjunctive treatment in the management of post-surgical and post-traumatic acute painIdentical
    ConnectivityBluetooth Capable: YesSmartphone Interface: YesBluetooth Capable: YesSmartphone Interface: YesIdentical
    Regulatory Classification (Use)Prescription (similar to BioWaveHOME reference device) / Over-the-Counter (BioWaveGO predicate)PrescriptionSimilar (Aligns with reference, differentiates from predicate, but justified by professional oversight)
    Power SourceOne 3.2V 1100mAh rechargeable lithium iron phosphate batteryOne 3.2V 1100mAh rechargeable lithium iron phosphate batteryIdentical (to BioWaveGO predicate)
    Line Current IsolationBattery + interlocksBattery + interlocksIdentical
    Patient Leakage CurrentNoneNoneIdentical
    Number of Output Modes/ChannelsOne / OneOne / OneIdentical
    Output RegulationRegulated VoltageRegulated VoltageIdentical
    Software/Firmware/Microprocessor ControlYesYesIdentical
    Safety FeaturesAutomatic Overload Trip: Yes (software)Automatic No-Load Trip: Yes (software)Automatic Shut Off: YesPatient Override Control: YesMany safety interlocksAutomatic Overload Trip: Yes (software)Automatic No-Load Trip: Yes (software)Automatic Shut Off: YesPatient Override Control: YesMany safety interlocksIdentical
    Indicator DisplayOn/Off Status: YesLow Battery: YesVoltage/Current Level: Yes (% of full scale)On/Off Status: YesLow Battery: YesVoltage/Current Level: Yes (% of full scale)Identical
    Timer Range30 minutes30 minutesIdentical
    Compliance with StandardsVoluntary Standards: Yes21 CFR 898: YesVoluntary Standards: Yes21 CFR 898: YesIdentical
    Physical DimensionsWeight: 6 ouncesDimensions: 3.0" x 4.0" x 1.0"Weight: 6 ouncesDimensions: 3.0" x 4.0" x 1.0"Identical (to BioWaveGO predicate)
    Housing MaterialsABS via conventional injection moldingABS via conventional injection moldingIdentical
    Waveform/ShapeBiphasic / Sum of 2 sine wavesBiphasic / Sum of 2 sine wavesIdentical
    Maximum Output Voltage80V p-p @ 500 Ω (20 V AC RMS) (BioWaveGO predicate)80V p-p @ 500 Ω (20 V AC RMS)Identical (to BioWaveGO predicate)
    Maximum Output Current160mA p-p @ 500 Ω (40mA RMS) (BioWaveGO predicate)160mA p-p @ 500 Ω (40mA RMS)Identical (to BioWaveGO predicate)
    Pulse WidthContinuous modulationContinuous modulationIdentical
    Frequency (Hz)4062 Hz + 3940 Hz (BioWaveGO predicate)4062 Hz + 3940 HzEquivalence based on frequency difference (to BioWaveHOME)
    Beat Frequency (Hz)122 Hz122 HzIdentical
    Net Charge (mC per pulse)0 @ 500 Ω (biphasic - AC coupled continuous wave)0 @ 500 Ω (biphasic - AC coupled continuous wave)Identical
    Maximum Current Density6.9 ma rms per cm² @ 500 Ω6.9 ma rms per cm² @ 500 ΩIdentical
    Maximum Power Density0.19 W rms per cm² @ 500 Ω0.19 W rms per cm² @ 500 ΩIdentical

    2. Sample size used for the test set and the data provenance

    Not applicable. As stated, "No additional testing was required for this Special 510(k)." The evidence for substantial equivalence relies on the existing clearance of the predicate device (BioWaveGO, K180943) and a reference device (BioWaveHOME, K152437), not a new clinical or performance test set for the BioWaveGO Rx.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. No new human-read test set was established. This submission is a comparison of technical specifications against previously cleared devices.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. No test set requiring expert adjudication was part of this submission.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. The device is a Transcutaneous Electrical Nerve Stimulator, not an AI-powered diagnostic imaging device or a device involving human readers or AI assistance in interpretation.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is a physical neuromodulation device, not an algorithm, and its performance is inherent to its electrical stimulation characteristics, not a standalone algorithmic output.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    For the BioWaveGO Rx, the "ground truth" for its substantial equivalence claim is the demonstrated safety and efficacy of its predicate device (BioWaveGO, K180943), which previously underwent its own regulatory clearance process. The current submission's "ground truth" is that the new device largely mirrors the predicate's technical and performance characteristics.

    8. The sample size for the training set

    Not applicable. This is a medical device, not a machine learning algorithm that requires a training set.

    9. How the ground truth for the training set was established

    Not applicable. As above, no training set was used.

    Ask a Question

    Ask a specific question about this device

    K Number
    K180943

    Validate with FDA (Live)

    Device Name
    BioWaveGO
    Date Cleared
    2018-08-17

    (129 days)

    Product Code
    Regulation Number
    882.5890
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The BioWaveGO Neuromodulation Pain Therapy Device is indicated for:

    • Symptomatic relief of chronic, intractable pain
    • Symptomatic relief of acute pain
    • As an adjunctive treatment in the management of post-surgical and post-traumatic acute pain
    Device Description

    The BioWaveGO Neuromodulation Pain Therapy Device is a battery-powered device intended to provide pain the technology of parent devices BioWavePRO. The key difference between the BioWaveGO and the parent device, the BioWaveHOME, is a reduced maximum voltage level, making the device available over-the-counter. The BioWaveGO device has a smaller battery system compared to the BioWaveGO device delivers the summed high frequency alternating current sinusoidal signals between electrodes, providing symptomatic relief of acute, chronic, and post-operative pain.

    AI/ML Overview

    The provided text describes the BioWaveGO Neuromodulation Pain Therapy Device, its indications for use, and a comparison with predicate devices to establish substantial equivalence for FDA clearance. However, it does not contain specific acceptance criteria, a detailed study proving device performance against those criteria, or information on sample sizes, ground truth establishment, or expert involvement as requested.

    The document primarily focuses on regulatory clearance through substantial equivalence, which compares a new device to existing legally marketed predicate devices, rather than an independent performance study with defined acceptance criteria and statistical analysis.

    Therefore, the requested information cannot be fully extracted from the provided text. I will detail what can be inferred or is explicitly stated.


    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly state quantitative acceptance criteria for device performance (e.g., minimum pain reduction, specific accuracy metrics). Instead, it focuses on functional and electrical safety compliance.

    Acceptance Criteria (Inferred from Performance Testing Summary)Reported Device Performance (Summary of Testing)
    Session timer operational only during active treatmentConfirmed
    Charging only when device not in useConfirmed
    Active treatment sessions cannot start during chargingConfirmed
    Consistent operation across various intensities and load impedancesEnsured
    Recognition of cable and electrodes before and during sessionEnsured
    Detection of invalid load impedances before and during sessionEnsured
    Resistance to damage/improper software operation from abuse of charger portsDetermined (no damage/improper operation)
    Inherent protection from excessive battery drain in over-temperature situationsDetermined (device protects against abnormal draw)
    Functional hardware watchdog timers for device resetDetermined (functional)
    Evaluation of electrical safetyConcluded as compliant (implied by clearance)
    Compliance with 21 CFR 898Yes
    Compliance with Voluntary StandardsYes

    2. Sample Size Used for the Test Set and Data Provenance

    This information is not provided in the document. The "Performance Testing Summary" outlines a list of tests conducted, but it does not specify the sample size of devices tested or any patient data provenance. The clearance is based on comparison to predicates and engineering/safety testing, not clinical performance data in patients.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not provided. The document describes technical performance testing and safety evaluations, not a study that would require expert-established ground truth related to clinical outcomes or image interpretation.

    4. Adjudication Method for the Test Set

    This information is not provided. As no clinical or interpretive "ground truth" establishment by experts is mentioned, an adjudication method is not applicable to the described engineering and safety tests.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not performed or mentioned in this document. This device is a Transcutaneous Electrical Nerve Stimulator (TENS) for pain relief, not an AI-assisted diagnostic tool.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This concept is not applicable to the BioWaveGO device. It is a physical medical device providing electrical stimulation, not an algorithm, and it is intended for human use, either over-the-counter or with a prescription (for its predicate).

    7. The Type of Ground Truth Used

    The "ground truth" for the tests described appears to be based on engineering specifications, safety standards, and functional requirements of the device. For example, ensuring the session timer is operational only during active treatment means verifying the device's software behaves according to its design specification under various conditions. There is no mention of pathology, expert consensus on clinical findings, or outcomes data being used as ground truth for the technical tests performed.

    8. The Sample Size for the Training Set

    This information is not provided. Since this is a hardware device cleared based on substantial equivalence and engineering tests, rather than an AI/ML algorithm or a device requiring a clinical efficacy trial with a training set, this concept is not applicable in the context described.

    9. How the Ground Truth for the Training Set was Established

    This information is not applicable as there is no mention of a training set for an algorithm or a device requiring such.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1