Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K102633

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2011-09-09

    (361 days)

    Product Code
    Regulation Number
    870.1200
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The "BIOTEQ" Angiographic Catheter is indicated for the delivery of radiopaque contrast medium to selected sites in the vascular system. The device is for use in the coronary and peripheral vasculature, and not for use in the neurovasculature.

    Device Description

    The BIOTEO® ANGIOGRAPHIC CATHETER is with the braided proximal shaft. The distal shaft of the catheter has variety configuration and the tip is made soft to minimize trauma to the vessel wall. It consists of the following major components: Soft Tube, Braiding tube, Screw Cap, F.L.L. Adapter, Adaptor Butterfly.

    AI/ML Overview

    The provided document pertains to the 510(k) premarket notification for the BIOTEQ® ANGIOGRAPHIC CATHETER. This is a medical device and the document describes performance testing rather than a study typically associated with AI/ML devices that would involve acceptance criteria, sample sizes for test/training sets, ground truth establishment, or expert reviews for diagnostic accuracy.

    Therefore, the requested information regarding acceptance criteria and studies typical for AI/ML devices (e.g., sample sizes for test/training sets, ground truth, expert qualifications, adjudication methods, MRMC studies, standalone performance) cannot be extracted from this document, as it focuses on the physical and biological performance of a catheter.

    Here's a breakdown of the performance testing conducted for this device, which serves a similar purpose to acceptance criteria for traditional medical devices:

    1. Table of Acceptance Criteria and Reported Device Performance (based on performance testing, not AI/ML metrics):

    Performance Test CategorySpecific TestAcceptance Criteria (Implied by "according to protocols based on international standards and in-house requirements")Reported Device Performance
    Physical PerformanceSurface RequirementsMeets established standards for surface finish and integrity.Achieved
    Corrosion ResistanceNo significant corrosion observed.Achieved
    Strength TestWithstands specified forces without failure (ee.g., tensile, burst).Achieved
    Leakage Tests (positive pressure, vacuum)No leakage under specified pressure and vacuum conditions.Achieved
    Flow Rate TestAchieves specified flow rates for contrast media delivery.Achieved
    Torque Strength TestWithstands specified torque without failure.Achieved
    Flexibility and Kink TestMaintains integrity and patency under bending and kinking.Achieved
    Dimensional VerificationMeets specified dimensional tolerances.Achieved
    Particle TestWithin limits for particle shedding.Achieved
    Catheter Twist Transmitting TestTransmits torque effectively to the distal tip.Achieved
    Catheter Shape RetentionRetains intended shape after use/manipulation.Achieved
    Freedom from leakage and damage under high static pressure conditionsNo leakage or damage under specified high static pressure.Achieved
    Aged 3-year Shelf Life TestingMaintains all performance characteristics after simulated aging (3 years).Achieved
    Packaging TestsN/AMaintains sterility and device integrity.Achieved
    Biocompatibility TestsIntracutaneous Reactivity StudyNon-reactive or low reactivity within established limits.Achieved
    Guinea Pig Maximization Sensitization StudyNon-sensitizing.Achieved
    Cytotoxicity TestingNon-cytotoxic.Achieved
    Intramuscular Implant Study (1 week)Biocompatible; no adverse tissue reaction.Achieved
    Acute Systemic Injection StudyNo acute systemic toxicity.Achieved
    Hemolysis (direct and indirect contact)Non-hemolytic.Achieved
    Thrombogenicity Study ISONon-thrombogenic (within limits).Achieved
    Salmonella Typhimurium Reverse Mutation Assay (Ames Test)Non-mutagenic.Achieved
    Complement Activation TestMinimal or no complement activation.Achieved
    Material Mediated PyrogenicityNon-pyrogenic.Achieved
    Sterilization ValidationETO Sterilization Validation StudyAchieves sterility assurance level (SAL).Achieved

    The study supporting these criteria:

    The document states: "Performance testing was conducted on the BIOTEO® ANGIOGRAPHIC Catheter to establish substantial equivalence. Testing was conducted according to protocols based on international standards and in-house requirements and included dimensional and functional testing. Additionally, the catheters were subjected to biocompatibility testing per ISO 10993."

    Missing Information (as per AI/ML context):

    The following points are not applicable or not provided in the context of this traditional medical device submission for an angiographic catheter:

    1. Sample size used for the test set and the data provenance: Not applicable. Performance testing for physical and biological characteristics does not involve "test sets" in the AI/ML sense.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. Ground truth for a physical device is established through engineering and biological testing standards.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This device is not an AI/ML diagnostic tool for human readers.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): The "ground truth" for this device's performance is defined by established engineering standards, material science properties, biocompatibility guidelines (e.g., ISO 10993), and functional performance specifications.
    7. The sample size for the training set: Not applicable.
    8. How the ground truth for the training set was established: Not applicable.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1