510(k) Data Aggregation

    K Number
    K170047

    Validate with FDA (Live)

    Date Cleared
    2017-09-09

    (247 days)

    Product Code
    Regulation Number
    870.2300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The All-in-One Health Monitor PC-303 is a device designed for spot-checking measuring of the patient's physiological parameters, such as Non-Invasive Blood Pressure (NIBP), Oxygen saturation (SpO2), Pulse Rate (PR) and Body Temperature (TEMP);

    Additionally, the device is available to communicate with the compatible Blood Glucose Monitoring System and ECG monitor to make the measurement.

    This device is applicable for Adult and Pediatic (age>3 years old) use in clinical institutions and has no conditions or factors of contraindication.

    Device Description

    The All-in-One Health Monitor, PC-303 is mobile modular designed patient monitor. It monitors the patient's blood oxygen saturation (SpO2) and pulse rate (PR) non-invasively by the photoelectric method. It can also measure non-invasive blood pressure (NIBP, the pressures of systolic, diastolic and mean) by the oscillating method and body temperature (TEMP) by the infrared radiation energy technology.

    Additionally, the device is also capable to link and communicate with the compatible Blood Glucose Meter and ECG monitor to make the measurement.

    This device system measure the patient's physical parameters with variety modules. It takes digital signals from NIBP, SpO2, Temperature module through COM ports, and receives ECG data, blood glucose data from compatible legally marketed ECG Monitor or BLOOD GLUCOSE MONITORING Device. The software to process the data, then display parameters on the screen and storage some useful information.

    This device is applicable for use in clinical institutions and has no conditions or factors of contraindication.

    AI/ML Overview

    The provided document describes the All-in-One Health Monitor, PC-303, and its substantial equivalence to a predicate device (UP-7000 Patient Monitor, K123711). The acceptance criteria are primarily based on meeting relevant international standards for medical electrical equipment and specific performance characteristics in comparison to the predicate device.

    1. A table of acceptance criteria and the reported device performance

    The acceptance criteria are not explicitly stated as distinct numerical targets in a single table within the document but are inferred from the comparison with the predicate device and the adherence to recognized international standards. The "reported device performance" is the claim of compliance with these standards and the equivalent performance to the predicate.

    Parameter/CharacteristicAcceptance Criteria (Implied by Predicate & Standards)Reported Device Performance (PC-303)
    General
    SafetyCompliance with IEC 60601-1"All the requirements of IEC 60601-1 were evaluated in this test report" (with specific exclusions)
    EMCCompliance with IEC 60601-1-2"Testing was performed to ascertain Electromagnetic Compatibility to other electrical devices... Emissions tests... Immunity tests... Harmonics current... Voltage fluctuation" - all passed.
    BiocompatibilityCompliance with ISO 10993-5, ISO 10993-10"Test article Contact Lens Case extract did not show potential toxicity to L-929 cells." "Test article extracts showed no significant evidence of causing ocular irritation." "Test article extract showed no significant evidence of causing skin sensitization."
    PerformanceEquivalent to predicate device"Each function operated within the design parameters, within the performance criteria established by the pertinent IEC standards." "established the equivalency to the predicate device."
    SpO2 Measurement
    Patient TypeAdult and PediatricAdult and Pediatric patients
    Measurement Accuracy$\pm$3% (70%-100%), Undefined (0-70%)$\pm$3% (during 70%-100%), Undefined (during 0-70%)
    Pulse Rate Range30 bpm-240 bpm30 bpm-240 bpm
    Pulse Rate Accuracy$\pm$2bpm or $\pm$2% (whichever is greater)$\pm$2bpm or $\pm$2% (whichever is greater)
    AlarmsFunctional alarms (Predicate has High/Low Limit)No Alarm (for SpO2 and Pulse Rate)
    NIBP Measurement
    MethodOscillometric methodOscillometric method
    Patient TypeAdult and Pediatric PatientsAdult and Pediatric patients
    Mean Deviation$\pm$5 mmHg$\pm$5 mmHg
    Standard Deviation$\le$8 mmHg$\le$8 mmHg
    Cuff Pressure Range0 to 300mmHg0 to 300mmHg
    Over Pressure ProtectionInternal operating software with limits, circuitryCuff pressure exceeds 300mmHg (Adult & Pediatric modes) at any time. (Similar to predicate's circuitry)
    AlarmsFunctional alarms (Predicate has High/Low Limit)No Alarm (for NIBP Systolic/Diastolic)
    Temperature Measurement
    Patient TypeAdult, PediatricAdult, Pediatric
    Unit of Measure°C or °F°C or °F
    Measurement SiteEar (for PC-303)Ear
    Measurement Range32.0°C to 43.0°C (90°F to 109.5°F)32.0°C to 43.0°C (90°F to 109.5°F)
    Measurement Accuracy$\pm$0.2°C (36.0-39.0°C), $\pm$0.3°C (rest)$\pm$0.2°C (36.0°C to 39.0°C), $\pm$0.3°C (the rest); $\pm$0.4°F (96.8°F to 102.2°F), $\pm$0.5°F (the rest)
    Blood Glucose (External Linked)
    IntegrationCommunication with compatible system"receives data from Blood Glucose Meter via the USB data interfaces for data communication"
    PerformanceAs per G-777G BLOOD GLUCOSE MONITORING SYSTEM (K113077)The linked device is a legally marketed system (K113077)
    ECG (External Linked)
    IntegrationCommunication with compatible system"receives data from Easy ECG Monitor via the USB data interfaces for data communication"
    PerformanceAs per PC-80 Easy ECG Monitor (K073152)The linked device is a legally marketed system (K073152)

    2. Sample size used for the test set and the data provenance

    The document states that "Clinical testing was performed for the NIBP functions and are submitted as part of this submission." However, it does not specify the sample size used for this clinical testing or the data provenance (e.g., country of origin, retrospective/prospective).

    For biocompatibility testing, the "In Vitro Cytotoxicity Test" used L929 mouse fibroblast cells, and the "Tests for irritation and skin sensitization" used guinea pigs. These are standard biological test methods, not human clinical sample sizes.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    The document does not provide information on the number or qualifications of experts used to establish ground truth for any of the performance or clinical studies.

    4. Adjudication method for the test set

    The document does not describe any adjudication method used for the test set.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This device is a patient monitor with built-in and external measurement capabilities for physiological parameters (SpO2, NIBP, TEMP, Blood Glucose, ECG). It is not an AI-assisted diagnostic device, and therefore, an MRMC comparative effectiveness study involving human readers improving with AI assistance would not be applicable and was not reported.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    The device is a medical instrument that provides physiological measurements. Its performance is inherent in its measurement capabilities and adherence to performance standards. The "standalone" performance is essentially its ability to accurately measure the parameters as specified, which is verified through testing against standards and comparison to a predicate device. The document mentions "Performance testing was performed to ensure that all of the device operated within specified parameters independently and with all other functions of the device operating." This indicates standalone performance testing of its direct measurement capabilities.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The ground truth for the measurements would typically be established by highly accurate reference instruments or established clinical methods, as dictated by the specific IEC/ISO/ASTM standards (e.g., for NIBP, a reference sphygmomanometer; for SpO2, a co-oximeter with induced hypoxia studies; for temperature, a reference thermometer). The document implies adherence to these standards for validation rather than explicitly stating ground truth derivation methods for each measurement. For NIBP, the reference to "clinical testing" would imply comparison to a clinically accepted gold standard.

    8. The sample size for the training set

    This device is a physiological monitor, not an AI/machine learning device that typically requires a "training set" in the context of algorithm development. Therefore, the concept of a training set sample size does not apply here.

    9. How the ground truth for the training set was established

    As the device does not employ a machine learning algorithm requiring a "training set," this question is not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K090096

    Validate with FDA (Live)

    Date Cleared
    2009-01-30

    (15 days)

    Product Code
    Regulation Number
    880.5025
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The All-In-One Container is intended for use in the compounding and storage of parenteral nutrition solutions prior to and during intravascular administration to a patient.

    Device Description

    The All-In-One Container is an empty EVA (Ethylene Vinyl Acetate) container intended for use in the compounding and storage of parenteral nutrition solutions prior to and during intravascular administration to a patient.

    AI/ML Overview

    The provided text describes a traditional 510(k) premarket notification for an "All-In-One Container" manufactured by Baxter Healthcare Corporation. This submission focuses on demonstrating substantial equivalence to a predicate device rather than detailing extensive performance studies with specific statistical acceptance criteria that one might find for a more complex diagnostic or AI-driven device.

    Based on the information provided, here's what can be inferred about acceptance criteria and the "study" (nonclinical tests) that proves the device meets them:

    1. A table of acceptance criteria and the reported device performance

    The document does not explicitly state numerical acceptance criteria in a table format for performance metrics. Instead, it makes a general statement:

    Acceptance Criteria (Implied)Reported Device Performance
    Device is appropriately designed for its intended use and meets safety/functional requirements."All test results meet the acceptance criteria, and support that the devices are appropriately designed for their intended use."

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    The document does not specify the sample size for any test set or the data provenance. It only refers to "risk analyses and design verification tests." These are typically internal tests, and details about sample size or origin are not usually disclosed in a 510(k) summary for this type of device.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    This information is not applicable and not provided. The testing described for this device (an empty container for compounding and storage) would involve engineering and quality control assessments, not expert-adjudicated ground truth like in a medical image analysis study.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    This information is not applicable and not provided. Adjudication methods are relevant for subjective assessments, typically in clinical trials or diagnostic studies, not for the design verification of a medical container.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not applicable and not provided. An MRMC study is relevant for evaluating the performance of diagnostic tools (especially AI-powered ones) in conjunction with human readers. This device is a passive medical container, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This information is not applicable and not provided. A standalone algorithm performance study is relevant for AI-powered devices. This device is an empty container and does not have an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    This information is not applicable in the context of this device. The "ground truth" for a medical container involves meeting established engineering specifications, material properties, sterility, and functional requirements. It would be determined through validated testing methods, not expert consensus or pathology.

    8. The sample size for the training set

    This information is not applicable and not provided. The "All-In-One Container" is a physical medical device, not an algorithm that requires a training set.

    9. How the ground truth for the training set was established

    This information is not applicable and not provided for the same reasons as above.


    Summary of the "Study" (Nonclinical Tests) Mentioned:

    The document states:

    • "Baxter Healthcare Corporation conducts risk analyses and design verification tests based on the result of these analyses."
    • "All test results meet the acceptance criteria, and support that the devices are appropriately designed for their intended use."

    This indicates that Baxter performed internal nonclinical testing to ensure the device met its design specifications and safety requirements. These tests are typically related to:

    • Material properties: Ensuring the EVA material is suitable for parenteral nutrition solutions (e.g., chemical compatibility, extractables/leachables).
    • Physical integrity: Testing the container for leaks, burst strength, and resistance to damage during storage and handling.
    • Sterility: Verifying the container can be sterilized and maintains sterility until use.
    • Functional aspects: Ensuring the transfer sets (single or three lead) function correctly with the container.

    The "acceptance criteria" would be internally defined specifications for these tests (e.g., "no leaks when subjected to X pressure," "material compatible with Y solution for Z duration"). The "study" is the execution of these design verification tests, and the "proof" is that all results met the predetermined acceptance criteria. The 510(k) process in this instance relies heavily on demonstrating substantial equivalence to a previously cleared predicate device (K983294), implying that the established testing methods and acceptance criteria for the predicate device would also apply to the new device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K050647

    Validate with FDA (Live)

    Device Name
    ALL-IN-ONE
    Manufacturer
    Date Cleared
    2005-04-20

    (37 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    As a Universal Self-Etching Adhesive System, ALL-IN-ONE Adhesive, as the name implies, is the only product one needs to etch, prime, and bond to a tooth structure and dental substrates.

    ALL-IN-ONE is used for:

    1. Direct restorations (composite, amalgam)
    2. All indirect restorations (composite, metal, porcelain)
    3. Desensitization of crown preparations prior to impression making/provisionalization
    4. Composite core build-ups
    5. Composite to metal/set amalgam (direct veneering)
    6. Root desensitization
    7. New amalgam to existing amalgam
    8. Repairs (composite-to-composite, composite-to-porcelain)
    Device Description

    As a Universal Self-Etching Adhesive System, ALL-IN-ONE Adhesive, as the name implies, is the only product one needs to etch, prime, and bond tooth structure. It is a twocomponent, single step adhesive system. ALL-IN-ONE is a light cure system that may be used for bonding both light-cure and self-cure composites, porcelain, and metal. ALL-IN-ONE may also be used for desensitization of tooth structures.

    AI/ML Overview

    The provided document is a 510(k) Summary for a dental adhesive (ALL-IN-ONE) and describes its substantial equivalence to predicate devices, rather than presenting a study with specific acceptance criteria and detailed performance data like an AI/ML device would. Therefore, many of the requested categories are not applicable.

    Here's an analysis based on the provided text:

    Acceptance Criteria and Device Performance (Not applicable for this type of submission)

    The document does not specify quantitative acceptance criteria or a reported device performance in the way an AI/ML device would, which might involve metrics like sensitivity, specificity, or AUC. Instead, it relies on demonstrating substantial equivalence to predicate devices based on intended use, chemical composition, and mechanical/physical properties.

    PropertyAcceptance Criteria (Implied by Predicate)Reported Device Performance (ALL-IN-ONE)
    Intended useSelf-Etching, Single Step Dental Adhesive (PROMPT L-POP)Self-Etching, Single Step Dental Adhesive
    Multi-Step Dental Adhesive (ALL-BOND 2)
    Chemical compositionLight-cure, unfilled, multifunctional methacrylate based resin (PROMPT L-POP)Light-cure, unfilled, multifunctional methacrylate based resin
    Dual-cure, unfilled, multifunctional methacrylate based resin (ALL-BOND 2)
    Mechanical /physical propertiesLow viscosity, yellow colored dental etching, priming, and bonding agent (PROMPT L-POP & ALL-BOND 2)Medium viscosity, light pink colored dental etching, priming, and bonding agent
    Oral ToxicityNon-toxicNon-toxic

    Explanation: The "acceptance criteria" here are implicitly met by demonstrating similar attributes to the predicate devices. The "reported device performance" is a description of ALL-IN-ONE's characteristics. The submission emphasizes that "side by side comparisons... clearly demonstrates that the applicant device is substantially equivalent to the legally marketed devices."


    Study Details (Not applicable for this type of submission)

    Since this is a submission for a dental adhesive demonstrating substantial equivalence, not an AI/ML device with performance studies, the following categories are not applicable and cannot be extracted from the provided text.

    1. Sample size used for the test set and the data provenance: Not applicable. No test set of clinical data from patients is described.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. No ground truth for a test set of clinical data is established.
    3. Adjudication method for the test set: Not applicable.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This is not an AI/ML device.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable. This is not an AI/ML device.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc): The ground truth for the safety of the device was "oral toxicity testing" which found it to be non-toxic. For efficacy, the ground truth is established by its chemical and physical similarity and intended uses aligning with the predicate devices which are already deemed safe and effective.
    7. The sample size for the training set: Not applicable. No training set for an algorithm is discussed.
    8. How the ground truth for the training set was established: Not applicable.
    Ask a Question

    Ask a specific question about this device

    K Number
    K020485

    Validate with FDA (Live)

    Date Cleared
    2002-03-12

    (27 days)

    Product Code
    Regulation Number
    880.5025
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The All-In-One® Two Chamber Container is intended for the compounding, storage, and administration of total parenteral nutrition (TPN) solutions.

    Device Description

    The All-In-One® Two Chamber Container is a sterile non-invasive fluid container used for compounding, storage and administration of total parenteral nutrition (TPN) solutions. It is an empty single use, disposable I.V. container that is vertically divided into two chambers. The left chamber is intended to store lipid emulsions. The right chamber is intended to store amino acid/dextrose admixtures. Additives may be added via the non-latex medication injection port located at the bottom of the left chamber. The chambers are designed to be filled with a total parenteral nutrition (TPN) solution by a pharmacy operation.

    The contents of the container are intended to be stored with the seal intact (i.e., not broken) until the time of use (administration to the patient).

    At the time of use, the contents of the two chambers are combined/mixed by opening the vertical peel-seal that runs along the inside of the container. The mixed contents of the container are then dispensed to the patient though a secondary administration set (i.e., a separate medical device that is not the subject of this submission).

    AI/ML Overview

    This document does not contain information about acceptance criteria or a study proving the device meets those criteria. It is a 510(k) summary for a medical device (All-In-One Two Chamber Container) which describes its intended use and states that non-clinical tests demonstrate acceptable performance, but does not provide details about the specific tests, acceptance criteria, or their results. It also confirms that the device is substantially equivalent to a predicate device.

    Therefore, I cannot provide the requested information.

    Ask a Question

    Ask a specific question about this device

    K Number
    K983294

    Validate with FDA (Live)

    Date Cleared
    1998-11-03

    (43 days)

    Product Code
    Regulation Number
    880.5025
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The All-In-One™ Container is intended for use in the compounding and storage of parenteral nutrition solutions prior to and during intravascular administration to a patient.

    Device Description

    The All-In-One™ Container is an empty, EVA container intended for use in the compounding and storage of parenteral nutrition solutions prior to and during intravascular administration to a patient. The container will be marketed in sizes ranging from 150 mL to 4000 mL. The proposed container is similar to Baxter Healthcare Corporation's currently marketed All-In-One™ Container cleared on June 10, 1994 under K932477.

    There is one solution contact material in the proposed All-In-One™ Container which is new to Baxter. It is an ethy ene vinyl acetate (EVA) film which is used to fabricate the container body. The other solution materials used in the proposed device were previously tested and used in other Baxter devices for similar IV container applications.

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study for the Modified All-In-One™ Container:

    No specific acceptance criteria or detailed study results are provided in the given 510(k) summary.

    The document predominantly focuses on establishing substantial equivalence to a predicate device (K932477) by highlighting that the new device is nearly identical, with the only change being a new EVA film for the container body. The testing described is primarily for the new material's biological and physicochemical properties and the overall functional performance of the device.

    However, based on the information provided, we can infer some general aspects of the testing and its outcomes.


    Implied Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (Implied)Reported Device Performance
    1. Biological Reactivity: New EVA film must be biocompatible.The material was found to be acceptable for its intended use, based on ISO 10993-1.
    2. Chemical Reactivity: New EVA film must be chemically stable and inert.The material was found to be acceptable for its intended use, based on USP 23 General Chapter <661>.
    3. Functional Performance: The proposed container must meet or exceed all functional requirements for its intended use.Data indicates that the proposed All-In-One™ Container meets or exceeds all functional requirements.

    Study Information (Based on Available Text)

    1. Sample Size Used for Test Set and Data Provenance:

      • Sample Size: Not specified. The document states "Data regarding the functional performance... have been generated and submitted" and refers to "biological methods specified in ISO Standard 10993-1 and USP physicochemical tests described in General Chapter <661>". These standards typically outline testing methodologies which would involve a certain number of samples or replicates, but the exact sample sizes used in this specific submission are not detailed.
      • Data Provenance: Not explicitly stated, but given that Baxter Healthcare Corporation is a U.S. company submitting to the FDA, it is highly likely the studies were conducted in the U.S. and are retrospective analyses of internal testing.
    2. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications:

      • Not applicable/Not specified. This device is a medical container, and the testing described is material and functional performance testing, not diagnostic performance where "ground truth" is established by human experts. The ground truth (or reference standard) would be defined by the specifications of the materials and the functional design, and evaluated by laboratory instruments and standardized protocols.
    3. Adjudication Method for the Test Set:

      • Not applicable/Not specified. Adjudication methods (like 2+1, 3+1) are typically used in clinical studies or diagnostic performance evaluations where human interpretation is involved. For material and functional testing, the results are objectively measured against pre-defined specifications.
    4. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

      • No, an MRMC study was not done. This type of study is relevant for diagnostic devices that involve human interpretation (e.g., radiology AI). The device described is a medical container, not a diagnostic tool requiring human readability or interpretation.
    5. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study:

      • No, this is not relevant for this device. "Standalone" performance refers to the capability of an algorithm without human intervention, which applies to AI/software as a medical device. This is a physical medical container.
    6. Type of Ground Truth Used:

      • Material Testing: The ground truth for the biological and chemical reactivity testing would be the standards themselves (ISO 10993-1 and USP 23 General Chapter <661>) and the pass/fail criteria defined within those standards or Baxter's internal specifications derived from them.
      • Functional Testing: The ground truth for functional performance would be the engineering and design specifications for the container (e.g., leak integrity, tensile strength, clarity, sterility maintenance, compatibility with parenteral nutrition solutions over time).
    7. Sample Size for the Training Set:

      • Not applicable/Not specified. This is not an AI/machine learning device, so there is no concept of a "training set" in the context of the device's development or validation.
    8. How the Ground Truth for the Training Set Was Established:

      • Not applicable. As above, there is no training set for this type of device.