510(k) Data Aggregation

    K Number
    K230845

    Validate with FDA (Live)

    Date Cleared
    2023-04-27

    (30 days)

    Product Code
    Regulation Number
    892.2050
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    32HL512D: This Medical Monitor is indicated for use in displaying radiological images for review, analysis, and diagnosis by trained medical practitioners. The display is not intended for mammography.

    31HN713D, 32HQ713D: This Medical Monitor is indicated for use in displaying radiological images (including full-field digital mammography and digital breast tomosynthesis) for review, analysis, and diagnosis by trained medical practitioners.

    Device Description

    The Medical monitor is intended to provide high resolution color and grayscale medical imaging for PACS and Radiology system. This Medical Monitor is intended to be used by trained medical practitioners for displaying, reviewing, and analysis of medical images.

    AI/ML Overview

    The provided text describes a medical monitor device (32HL512D, 31HN713D, 32HQ713D) and its associated software, "LG Calibration Studio Medical," which is used for calibration. The acceptance criteria and the study performed relate to the performance of the medical monitor and the calibration software, not an AI algorithm for image analysis. Therefore, there is no information about AI-specific aspects such as training sets, ground truth establishment for AI, or comparative effectiveness studies with human readers assisted by AI.

    Here's the information derived from the text regarding the device and its software:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria for the medical monitors are derived from the FDA guidance "Display Devices for Diagnostic Radiology." The reported performance for all three models (32HL512D, 31HN713D, 32HQ713D) is that they "Pass" all tested measurements.

    MeasurementsAcceptance CriteriaReported Device Performance (32HL512D, 31HN713D, 32HQ713D)
    a. Conformance to a grayscale-to-luminance functionConformance to a grayscale-to-luminance function (implied by FDA guidance requirements)Pass
    b. Luminance uniformity or Mura testLuminance uniformity or Mura test (implied by FDA guidance requirements)Pass
    c. Stability of luminance and chromaticity response with temperature and time of operation (on-time)Stability of luminance and chromaticity response with temperature and time of operation (on-time) (implied by FDA guidance requirements)Pass
    d. Spatial noiseSpatial noise (implied by FDA guidance requirements)Pass
    e. Veiling glare or small-spot contrastVeiling glare or small-spot contrast (implied by FDA guidance requirements)Pass

    Note: The document states, "All display characteristics of the 32HL512D, 31HN713D and 32HQ713D have met the predefined criteria. Therefore, the performance of 32HL512D, 31HN713D and 32HQ713D were verified through the performance test." The FDA guidance "Display Devices for Diagnostic Radiology" serves as the basis for these predefined criteria.

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: Not explicitly stated as the testing is on the physical device's characteristics rather than a dataset of medical images. The tests were performed on one or more units of each model (32HL512D, 31HN713D, 32HQ713D).
    • Data Provenance: Not applicable in the context of device performance testing. The "data" here refers to measurements taken directly from the physical monitors during bench testing. The tests adhere to international standards (e.g., IEC standards) and FDA guidance for medical display devices.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    Not applicable. The ground truth for the performance of the medical monitors is established by objective physical measurements against established technical standards and FDA guidance, not by expert interpretation of images.

    4. Adjudication Method for the Test Set

    Not applicable. Adjudication methods like 2+1 or 3+1 are typically used for expert consensus in image interpretation. This study involves objective technical measurements.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No. There is no mention of an MRMC study. The devices are medical monitors for displaying images, not AI algorithms.

    6. If a Standalone Study (Algorithm Only Without Human-in-the-Loop Performance) Was Done

    A standalone performance test was done for the device, focusing on its technical display characteristics. The "LG Calibration Studio Medical" software (a moderate level of concern software) was also verified and validated, but this is a calibration tool, not an image analysis algorithm. Therefore, "standalone (i.e. algorithm only without human-in-the-loop performance)" is applicable to the technical performance of the monitor as a device, and to the verification and validation of the calibration software, but not in the context of AI for medical image interpretation.

    7. The Type of Ground Truth Used

    The ground truth used for the device's performance testing is based on objective physical measurements and technical specifications set forth by international standards (e.g., IEC 60601-1, IEC 60601-1-2, IEC 62304) and the FDA guidance "Display Devices for Diagnostic Radiology."

    8. The Sample Size for the Training Set

    Not applicable, as this is not an AI algorithm for image analysis. The "LG Calibration Studio Medical" is software, validated according to IEC 62304, but the text does not describe a "training set" in the machine learning sense for this calibration software.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. There is no training set for an AI algorithm mentioned in relation to the devices or their calibration software.

    Ask a Question

    Ask a specific question about this device

    K Number
    K192925

    Validate with FDA (Live)

    Device Name
    32HL512D
    Date Cleared
    2020-03-13

    (149 days)

    Product Code
    Regulation Number
    892.2050
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    This Medical Monitor is indicated for use in displaying radiological images for review, analysis, and diagnosis by trained medical practitioners. The display is not intended for mammography.

    Device Description

    The Medical monitor is intended to provide high resolution color and grayscale medical imaging for PACS and Radiology system. This Medical Monitor is intended to be used by trained medical practitioners for displaying, reviewing, and analysis of medical images

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information based on the provided document, addressing each of your points.

    It's important to note that this document is a 510(k) summary for a medical monitor (32HL512D) intended for displaying radiological images. It is not an AI/algorithm-based diagnostic device. Therefore, many of your questions related to AI performance, ground truth, expert consensus, MRMC studies, and training sets will not be applicable to this submission. The "device" in this context is a monitor, not a diagnostic algorithm.

    Acceptance Criteria and Device Performance for LG 32HL512D Medical Monitor

    The acceptance criteria for this device (a medical monitor) are primarily related to its technical specifications for displaying medical images and compliance with electrical safety and EMC standards. The "performance" is demonstrated by meeting these specifications and showing compliance.

    1. Table of Acceptance Criteria and Reported Device Performance

    ParameterAcceptance Criteria (from predicate or general medical display requirements)Reported Device Performance (LG 32HL512D)
    Indications for UseDisplay radiological images for review, analysis, and diagnosis by trained medical practitioners. Not intended for mammography.This Medical Monitor is indicated for use in displaying radiological images for review, analysis, and diagnosis by trained medical practitioners. The display is not intended for mammography. (Matches exactly)
    Electrical SafetyCompliance with IEC 60601-1:2005/AMD1:2012Complies with IEC 60601-1:2005/AMD1:2012
    Electromagnetic Compatibility (EMC)Compliance with IEC 60601-1-2 Edition 4.0:2014Complies with IEC 60601-1-2 Edition 4.0:2014
    UsabilityCompliance with IEC 60601-1-6:2010/A1:2013Complies with IEC 60601-1-6:2010/A1:2013
    Software Validation (if applicable)Designed and developed according to a software development process; verified and validated (for MODERATE level of concern software)Software was designed and developed according to a software development process and was verified and validated. (MODERATE level of concern)
    Resolution(Implied comparison to predicate/PACS needs)3,840 x 2,160 pixels
    Screen Size(Implied comparison to predicate/PACS needs)718.2 x 414.3 mm (or 31.5" diagonal through module description)
    Display TechnologyTFT LCD with specific display capabilities for medical images.TFT Liquid Crystal Display module with LED Backlight unit, 30-pin eDP port, 4 lane eDP interface, supports 3840 x 2160 UHD mode, 10-bit drivers.
    Pixel Pitch(Implied comparison to predicate/PACS needs)0.18159 x 0.18159 mm
    Input Video SignalsStandard video inputs for medical imaging systems.DisplayPort x 2, HDMI x 1

    Note: The document focuses on demonstrating substantial equivalence to a predicate device rather than setting explicit quantifiable acceptance thresholds for all performance parameters in the context of a new, unique claim. Its performance is accepted if it is shown to be as safe and effective as the predicate, despite technological differences. The "reported device performance" are its specifications and compliance with standards.


    Regarding the Study Proving Device Meets Acceptance Criteria:

    The document states: "No clinical studies were considered necessary and performed." This is crucial. This is a submission for a medical display monitor, not a diagnostic algorithm or device that makes a clinical determination. Therefore, the "study" proving it meets acceptance criteria is primarily non-clinical testing and a comparison to a predicate device.

    2. Sample Size Used for the Test Set and Data Provenance:

    • Sample Size: Not applicable in the context of patient data or algorithm performance. The "test set" for a monitor would be the monitor itself undergoing various electrical, EMC, and display characteristic tests.
    • Data Provenance: Not applicable. The testing is on the physical monitor, not a dataset.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications:

    • Not applicable. There is no "ground truth" to establish in the sense of medical diagnoses for this device. The device itself is the display. The "experts" involved would be engineers and metrologists conducting the technical measurements and ensuring compliance with display standards and safety regulations.

    4. Adjudication Method for the Test Set:

    • Not applicable. This concept pertains to resolving discrepancies in expert interpretations of medical data, which is not relevant for a medical monitor.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done:

    • No, not performed. This type of study is relevant for evaluating the impact of AI algorithms or new diagnostic methods on human reader performance. As this is a medical monitor, an MRMC study is not part of its substantial equivalence demonstration.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • No, not applicable. This device is a monitor, not a standalone diagnostic algorithm.

    7. The Type of Ground Truth Used:

    • Not applicable. There is no 'ground truth' in the clinical diagnostic sense for a medical display monitor. The "ground truth" for its performance is its measured technical specifications and compliance with relevant industry and safety standards (e.g., DICOM Part 14 for display characteristics, IEC standards for safety).

    8. The Sample Size for the Training Set:

    • Not applicable. This device does not use a training set as it is not an AI/machine learning algorithm.

    9. How the Ground Truth for the Training Set Was Established:

    • Not applicable. No training set exists for this device.