Search Filters

Search Results

Found 3 results

510(k) Data Aggregation

    K Number
    K121531

    Validate with FDA (Live)

    Date Cleared
    2012-07-17

    (54 days)

    Product Code
    Regulation Number
    868.5440
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    A&J 5L POCA series Oxygen Concentrator is intended for use as an oxygen concentrator to provide supplemental low flow oxygen therapy at home, in nursing homes, at patient care facilities. A&J 5L POCA series is available by prescription only under the supervision of a physician.

    Device Description

    A&J 5L POCA series Oxygen concentrator is AC power electrically operated. The unit separates oxygen from room air (ambient air) which allows high-purity supplemental oxygen to be delivered through the oxygen outlet, although the concentrator filters the oxygen in a room, it will not affect the normal amount of oxygen in your room. Air is drawn into the device with a compressor and exposed to molecular sieve adsorbent that selectively retains nitrogen and other components until they are released when the pressure is vented to the atmosphere. This cycle is controlled by a motorized value and protected from over pressurization by the compressor's pressure relief value.

    Oxygen provided by the A&J 5L POCA series Oxygen concentrator is delivered to the user by means of standard oxygen supply tubing and a standard nasal cannula or mask. A standard bubble humidifier may be used, if physician has prescribed an oxygen humidifier as part of therapy.

    The front panel of the A&J 5L POCA series Oxygen concentrator contains the controls and indicators. These include the status lights (included power light, normal oxygen light, fow oxygen light and service required light), standard power switch, flow meter knob, a circuit breaker which could reset the device after electrical overload shutdown, an oxygen outlet which oxygen is dispersed through, a monitor display which indicates the condition of system status (included pressure status, oxygen purity status and electric hour meter, etc.). The user could operate the device conveniently according to the instructions.

    AI/ML Overview

    Here's an analysis of the provided text regarding the A&J 5L POCA series Oxygen Concentrator, focusing on acceptance criteria and supporting studies:

    Summary of Acceptance Criteria and Device Performance

    The device is claiming substantial equivalence to a predicate device (A&J 5L Oxygen Concentrator, Model: POCA01) and therefore the acceptance criteria are implicitly met by demonstrating that its performance is comparable or better than the predicate, and it complies with relevant standards. The table below summarizes the key performance elements compared.

    Elements of ComparisonAcceptance Criteria (Predicate Device)Reported Device Performance (Subject Device)Does Device Meet Criteria?
    Operating ConditionsTemperature: 10-35 ℃, Humidity: 30-70 %, Atmospheric Pressure: 50~106 kPaTemperature: 10-40 ℃, Humidity: 30-70 %, Atmospheric Pressure: 50~106 kPaYes (Wider temp range)
    Storage ConditionsTemperature: -4070 ℃, Humidity: 10100 %, Atmospheric Pressure: 50~106 kPaTemperature: -4070 ℃, Humidity: 10100 %, Atmospheric Pressure: 50~106 kPaYes
    Power Input115 V, 60 Hz, 1.8A (Max.)115V, 60Hz, 3.1AYes (Complies with IEC 60601-1)
    Degree of Protection Against Electric ShockType B EquipmentType B EquipmentYes
    Electrical SafetyCompliance with IEC 60601-1Compliance with IEC 60601-1Yes
    EMCCompliance with IEC 60601-1-2Compliance with IEC 60601-1-2Yes
    Delivery Rate0 to 5 LPM0 to 5 LPMYes
    Oxygen Percentage93% ± 2%93% ± 2%Yes
    Outlet Pressure8.5 psi (58.6 kPa)8.5 psi (58.6 kPa)Yes
    Sound Level45-47 dbA (Overall Average)< 45 dbA (Overall Average)Yes (Lower sound level, complies with ISO 8359)
    Operating SystemTime Cycle / Pressure Swing AdsorptionTime Cycle / Pressure Swing AdsorptionYes
    Mode of OperationContinuousContinuousYes
    BiocompatibilityConduct output gases testsPatient/gas pathway materials same as predicate (no new issues)Yes
    AccessoriesUse legitimate marketing productsSame as predicate deviceYes

    Study Details:

    1. Sample size used for the test set and the data provenance:

      • The document does not explicitly state a "test set" in the context of clinical data for performance evaluation of a diagnostic or algorithmic device. Instead, the testing is bench performance testing and compliance with standards. Therefore, the concept of a "sample size" for a test set and "data provenance" (country of origin, retrospective/prospective) as typically applied to AI/imaging studies does not directly apply here.
      • The studies conducted are laboratory tests to validate and verify design specifications and substantial equivalence to the predicate device.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable. This is a medical device (oxygen concentrator) and its performance is evaluated against engineering specifications and physical measurements, and compliance with recognized standards (ASTM, ISO, IEC), not clinical ground truth established by medical experts for diagnostic accuracy.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • Not applicable for the same reasons as above.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • Not applicable. This is a standalone medical device (oxygen concentrator) and does not involve AI assistance for human readers or interpretation of medical images/data.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Yes, in a sense. The performance evaluation is entirely standalone, focused on the device's physical and electrical properties, and its ability to produce oxygen of a specified purity at a specified flow rate, without human intervention in its core function.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

      • The "ground truth" for this device's performance evaluation comes from:
        • Engineering specifications and measurements: e.g., oxygen percentage (93% ± 2%), delivery rate (0-5 LPM), outlet pressure (8.5 psi), sound level (<45 dbA).
        • Compliance with recognized international standards: ASTM F1464, ISO 8359, IEC 60601-1, IEC 60601-1-2.
        • Demonstration of substantial equivalence to a legally marketed predicate device.
    7. The sample size for the training set:

      • Not applicable. This device does not use machine learning or AI algorithms that require a "training set" of data. Its design and function are based on engineering principles.
    8. How the ground truth for the training set was established:

      • Not applicable, as no training set was used.
    Ask a Question

    Ask a specific question about this device

    K Number
    K071608

    Validate with FDA (Live)

    Date Cleared
    2008-01-11

    (213 days)

    Product Code
    Regulation Number
    868.5440
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The A&J-POCA01 Oxygen Concentrator is intended for use as an oxygen concentrator to provide supplemental low flow oxygen therapy in the home, nursing homes, patient care facilities, etc. The A&J-POCA01 is available by prescription only under the supervision of a physician, and is not intended to support or sustain life.

    Device Description

    The A&J-POCA01 Oxygen Concentrator is intended for use as an oxygen concentrator to provide supplemental low flow oxygen therapy in the home, nursing homes, patient care facilities, etc. The A&J-POCA01 is available by prescription only under the supervision of a physician, and is not intended to support or sustain life.

    The A&J-POCA01 is an AC power electrically operated. The unit separates oxygen from room air (ambient air) which allows high-purity supplemental oxygen to be delivered through the oxygen outlet, although the concentrator filters the oxygen in a room, it will not affect the normal amount of oxygen in your room. Air is drawn into the device with a compressor and exposed to molecular sieve adsorbent that selectively retains nitrogen and other components until they are released when the pressure is vented to the atmosphere. This cycle is controlled by a motorized value and protected from over pressurization by the compressor's pressure relief value.

    Oxygen provided by the A&J-POCA01 Oxygen Concentrator is delivered to the user by means of standard oxygen supply tubing and a standard nasal cannula or mask. A standard bubble humidifier may be used, if physician has prescribed an oxygen humidifier as part of therapy.

    The front panel of the A&J-POCA01 contains the controls and indicators. These include the status lights (included power light, normal oxygen light, low oxygen light and service required light), standard power switch, flow meter and the flow meter knob, a circuit breaker which could reset the device after electrical overload shutdown, a oxygen outlet which oxygen is dispersed through, a monitor display which indicates the condition of system status (included pressure status, oxygen purity status and electric hour meter, etc). The user could operated the device conveniently according the instructions.

    AI/ML Overview

    The provided 510(k) summary for the A&J-POCA01 Oxygen Concentrator describes a medical device seeking substantial equivalence to a predicate device. This type of submission relies on demonstrating that the new device is as safe and effective as a legally marketed predicate device, rather than requiring a detailed clinical study with acceptance criteria and ground truth validation as would be typical for novel or higher-risk devices.

    Therefore, the document does not contain information on:

    • Acceptance criteria in the manner of performance metrics (e.g., sensitivity, specificity) for diagnosing or detecting a condition.
    • A "study that proves the device meets the acceptance criteria" in a clinical sense with a test set, ground truth, and expert evaluation.
    • Sample sizes for test sets or training sets for an AI/algorithm.
    • Number/qualifications of experts, adjudication methods, MRMC studies, or standalone algorithm performance studies.
    • Type of ground truth used (e.g., pathology, outcomes data).

    Instead, the submission focuses on bench performance testing to demonstrate functional equivalence and safety.

    Here's a summary of the information available, framed in response to your request, but highlighting the type of study conducted:

    1. Table of Acceptance Criteria and Reported Device Performance

    As this is a substantial equivalence submission for an oxygen concentrator, the "acceptance criteria" are not based on diagnostic performance metrics (e.g., sensitivity, specificity). Instead, they are related to engineering specifications and functional safety. The document does not provide a table with specific numerical targets and measured performance for each criterion. However, it states:

    Acceptance Criteria Category (Implied)Reported Device Performance
    Design SpecificationsMet all design specifications.
    Substantial EquivalenceDemonstrated substantial equivalence to the predicate device (Mark 5 Nuvo Oxygen Concentrator).
    Environmental TestingCompliant with FDA's DCRND November 1993 "Reviewer Guidance Document for Premarket notification Submissions" Draft Guidance Document.
    Industry Standards ComplianceCompliant with ASTM F1464, ISO 8359, IEC60601-1, IEC60601-1-2, IEC60601-1-4, and ISO14971.
    Safety & EffectivenessTechnologies "bring forth no new questions of safety and effectiveness." Differences from predicate (dimensions, weight, storage, power consumption, oxygen percentage) do not affect safety and efficiencies, with some characteristics being "better than the predicate."
    Hazard AnalysisPerformed, and testing conducted to validate system's overall operation.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: Not applicable in the context of a clinical test set for diagnostic performance. The testing involved laboratory and bench testing of the device itself.
    • Data Provenance: Not applicable for clinical data. The testing was conducted in a laboratory setting by the manufacturer, Zhongshan A & J Medical Equipment CO., LTD in China, to evaluate the device against specified engineering and regulatory standards. The testing was described as "Laboratory testing."

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of those Experts

    • This is not applicable as the study did not involve a clinical test set requiring expert-established ground truth for diagnostic purposes. The "ground truth" for this device would be its adherence to engineering specifications and performance standards as measured by laboratory equipment.

    4. Adjudication Method for the Test Set

    • Not applicable as there was no clinical test set requiring expert adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done

    • No, an MRMC comparative effectiveness study was not done. The device is an oxygen concentrator, not an imaging or diagnostic AI tool that would typically involve human readers.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was Done

    • Not applicable. The device is a physical medical device (an oxygen concentrator), not an algorithm or AI system.

    7. The Type of Ground Truth Used (expert consensus, pathology, outcomes data, etc.)

    • The "ground truth" for this medical device submission is its functional performance measured against established engineering specifications, safety standards, and regulatory requirements. This includes:
      • Compliance with various international and national standards (e.g., ASTM F1464, ISO 8359, IEC60601-1).
      • Verification against the predicate device's performance characteristics where relevant.
      • Results from hazard analysis.
      • Meeting internal design specifications.

    8. The Sample Size for the Training Set

    • Not applicable. This device does not use machine learning or AI that would require a "training set."

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable.
    Ask a Question

    Ask a specific question about this device

    K Number
    K071607

    Validate with FDA (Live)

    Date Cleared
    2007-06-26

    (14 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ASA01 Heavy Duty Suction Pump is a vacuum suction device designed to remove bodily fluids from the patients' airway or respiratory support system. It is intended for use by trained personnel under the direction of the physician.

    Device Description

    The ASA01 Heavy Duty Suction Pump is an AC-powered, stand-alone device, designed to collection of nonflammable fluid materials in medical applications.

    AI/ML Overview

    The provided text describes a 510(k) submission for the ASA01 Heavy Duty Suction Pump, but it does not contain specific acceptance criteria or a study proving the device meets them in the way typically expected for an AI/CADe device.

    This device is a physical medical device (a suction pump), not an AI or software-controlled device for diagnostic imaging or similar applications. Therefore, many of the requested categories (like "multi-reader multi-case (MRMC) comparative effectiveness study," "standalone performance," "ground truth" in the context of image interpretation, "training set size") are not applicable to this type of submission.

    Here's a breakdown based on the information available:


    Acceptance Criteria and Device Performance

    The submission focuses on demonstrating "substantial equivalence" to a predicate device (K052650 Pioneer U601 Series Aspiration) rather than meeting precise performance metrics derived from a clinical study for diagnostic accuracy.

    Table of Acceptance Criteria and Reported Device Performance (as far as applicable to this type of device):

    Acceptance Criteria (Implied)Reported Device Performance
    Safety and EffectivenessBench performance testing demonstrated substantial equivalence to predicate device.
    Design SpecificationsMet all design specifications.
    Environmental TestingPassed all environmental testing identified in FDA's DCRND November 1993 "Reviewer Guidance Document for Premarket notification Submissions" Draft Guidance Document.
    Hazard AnalysisHazard analysis of the system and its software was performed. Testing conducted to validate overall system operation.
    Compliance to StandardsTested to assure compliance to IEC60601-1, IEC60601-1-2, ISO10779-1, and ISO14971.
    BiocompatibilityNot applicable, as accessories that contact patients are not provided by the manufacturer.
    Software PerformanceNot applicable, as the device is not software-controlled.
    Clinical PerformanceNot applicable for this device type.

    Study Details (as applicable)

    1. Sample size used for the test set and the data provenance:

      • Test Set Sample Size: Not applicable in the context of a "test set" for AI/CADe performance. The evaluation was primarily through bench testing and compliance with standards.
      • Data Provenance: Not applicable for a physical suction pump. The testing was laboratory-based.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable. "Ground truth" in the AI/CADe sense (e.g., expert interpretation of images) is not relevant for a physical suction pump's functional testing.
    3. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

      • Not applicable. This concept applies to human reader consensus for diagnostic truth, which is not part of this device's evaluation.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No, a multi-reader multi-case (MRMC) comparative effectiveness study was not done. This type of study is relevant for AI-assisted diagnostic devices, not a physical suction pump.
    5. If a standalone (i.e. algorithm only without human-in-the loop performance) was done:

      • No, a standalone (algorithm only) study was not done. This device does not involve an "algorithm" in the AI sense. Its performance is inherent to its physical operation.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

      • Not applicable. The "ground truth" for a suction pump would be its ability to achieve certain vacuum pressures, flow rates, and maintain sterility, as measured by calibrated equipment and adherence to engineering specifications and standards.
    7. The sample size for the training set:

      • Not applicable. This device does not use machine learning or AI, so there is no "training set."
    8. How the ground truth for the training set was established:

      • Not applicable, as there is no training set.

    Summary for this specific device:

    The ASA01 Heavy Duty Suction Pump is a basic physical medical device. Its acceptance criteria and proof of performance are based on engineering bench testing, compliance with relevant industrial and medical device standards (IEC, ISO), hazard analysis, and demonstrating "substantial equivalence" in technological characteristics and intended use to a legally marketed predicate device (K052650 Pioneer U601 Series Aspiration). Concepts related to AI/CADe performance evaluation (like ground truth, test sets, training sets, reader studies) are not relevant to this submission.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1