Found 20 results

510(k) Data Aggregation

    K Number
    K253604

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-03-20

    (122 days)

    Product Code
    Regulation Number
    882.4560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TiLink-L Joint Fusion System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis.

    The TiLink-L Navigation Instruments are intended to be used with the TiLink-L Joint Fusion System during surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. These instruments are designed for use with the Medtronic StealthStation System S8, which is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as the pelvis or vertebra, can be identified relative to a CT or MRI based model, fluoroscopy images, or digitized landmarks of the anatomy. Fluoroscopy is intended to be used for navigating final implant placement.

    Device Description

    The TiLink-L Navigation Instruments include a Drill Bit, Drill Guide, and Inserter and are specifically designed to be used with the TiLink-L Joint Fusion System Implants. The TiLink-L Navigation Instruments are to be used with the NavLock Instruments and Medtronic StealthStation System S8. The TiLink-L Joint Fusion System is provided sterile (single use) and non-sterile (reusable) and the TiLink-L Navigation Instruments are manufactured from Stainless Steel per ASTM F899.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251714

    Validate with FDA (Live)

    Device Name
    Ion-C
    Manufacturer
    Date Cleared
    2026-01-16

    (227 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    18 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Ion-C System facet implants are intended to be placed bilaterally through a posterior surgical approach and spans the facet joint interspace. The Ion-C is intended for temporary stabilization as an adjunct to posterior cervical fusion in skeletally mature patients. The Ion-C is indicated for patients requiring a revision for an anterior pseudoarthrosis at one or two contiguous levels, from C3 to C7. The Ion-C is only intended to be used in combination with an FDA-cleared anterior cervical plate and intervertebral body fusion device implanted at the same level(s). The Ion-C is intended for use with autogenous and/or allogenic bone graft.

    Device Description

    Ion-C is intended for bilateral stabilization of the facets from C3-C7 at 1- or 2-contiguous levels. Ion-C is intended to be placed bilaterally through a posterior approach and is intended to span the facet joint interspace.

    Ion-C is designed for controlled non-impact placement to minimize damage to the implant and anatomy. Ion-C offers controlled implant depth by allowing in situ depth adjustment. The Ion-C offers a zero profile implant design which includes fenestrations and open barrels allow for bone graft integration and fusion. When Ion-C is implanted the joint is kept in a neutral position, reducing the risk of joint expansion. Ion-C engagement features are designed to resist implant expulsion.

    Ion-C includes various types of Implants, which can be provided sterile or non-sterile. All Implants are manufactured from Ti6Al4V per ASTM F136. The Ion-C Instruments are offered in various configurations, including single-use (provided sterile), and reusable (provided non-sterile). The Ion-C Instruments may be used to rasp or decorticate bone from the facets and/or transverse processes and for the delivery of bone graft.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251720

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-07-02

    (28 days)

    Product Code
    Regulation Number
    888.3045
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K243949

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-05-28

    (156 days)

    Product Code
    Regulation Number
    888.3045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    OsteoFlo HydroFiber is a bone void filler intended for use in osseous defects of the skeletal system that are not intrinsic to the stability of the bony structure i.e., the extremities, pelvis, intervertebral disc space, and posterolateral spine. These defects may be surgically created or the result of traumatic injury to the bone. OsteoFlo HydroFiber is indicated to be packed gently into bony voids or gaps of the extremities, pelvis, posterolateral spine, or intervertebral disc space, and may be used either standalone or in combination with autograft as a bone graft extender. The device is resorbed and replaced with host bone during the healing process. When used in intervertebral body fusion procedures, OsteoFlo HydroFiber must be used with an intervertebral body fusion device cleared by FDA for use with a bone void filler.

    Device Description

    The OsteoFlo® HydroFiber™ is a resorbable bone void filler designed to be placed in bony defects, either surgically created (i.e., tumor removal), or the result of traumatic injury. The single-use device is supplied sterile and dry. The device requires mixing with aqueous solution (autograft, saline, blood, or bone marrow aspirate) prior to use. OsteoFlo HydroFiber may be used as standalone, equivalent to autograft, in conjunction with autograft, or as a bone graft extender.

    AI/ML Overview

    It appears there's a misunderstanding. The provided FDA 510(k) clearance letter for the OsteoFlo HydroFiber device is for a Resorbable Calcium Salt Bone Void Filler Device, which is a physical implantable device.

    The request asks for information typically associated with AI/ML-based medical devices, particularly regarding:

    • A table of acceptance criteria and reported device performance (often including metrics like sensitivity, specificity, AUC for AI models)
    • Sample sizes for test sets, data provenance
    • Expert involvement for ground truth establishment (e.g., radiologists for image interpretation)
    • Adjudication methods
    • Multi-reader multi-case (MRMC) studies
    • Standalone performance (algorithm only) vs. human-in-the-loop performance
    • Types of ground truth (e.g., pathology, outcomes data)
    • Training set sample size and ground truth establishment

    The provided FDA letter does not contain any information related to AI/ML software performance or studies. Instead, it lists non-clinical performance data for a physical medical device, such as:

    • Biocompatibility
    • Sterilization validation
    • Packaging validation
    • Shelf-life testing
    • Endotoxin validation
    • Material characterization
    • Dimensional stability assessment
    • In vivo evaluation (Rabbit Metaphyseal Defect Model)
    • Pyrogenicity Testing

    Therefore, I cannot fulfill your request based on the provided text, as the document describes the clearance of a physical bone void filler, not an AI/ML software device. The acceptance criteria and performance studies mentioned in the document are for the physical properties and biological interactions of an implantable material, not for the diagnostic or analytical performance of an AI algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243580

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-02-05

    (78 days)

    Product Code
    Regulation Number
    880.5860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The GraftGun Universal Graft Delivery System (GDS®) is intended to be used for the delivery of hydrated allograft, autograft, or synthetic bone graft material to an orthopedic surgical site, via direct visualization or minimally invasive.

    Device Description

    The GraftGun Universal Graft Delivery System (GDS®) consists of a sterile, single-use, disposable device, and non-sterile reusable Adapter Tips intended for the delivery of prepared allograft, autograft, or synthetic bone graft material to an orthopedic surgical site. The GraftGun Universal Graft Delivery System (GDS®) includes the GraftGun Dispensing Unit, Loading Device, Graft Tubes, and Adapter Tips.

    AI/ML Overview

    The provided text describes a medical device, the GraftGun Universal Graft Delivery System (GDS®), and its 510(k) clearance process. However, this document does not contain information about the acceptance criteria or a study proving the device meets those criteria in the context of an Artificial Intelligence (AI) or machine learning (ML) system.

    The device described is a piston syringe used for delivering bone graft material. The performance testing mentioned (Compatibility Assessments, Sterilization Validations, Cleaning Validations, Biocompatibility Assessment, Package Performance, Shelf-Life Testing) are standard tests for mechanical medical devices to ensure their safety, functionality, and sterility. They are not related to AI/ML performance metrics such as sensitivity, specificity, AUC, or reader studies.

    Therefore, I cannot fulfill your request for the specific details about AI/ML acceptance criteria and study data based on the provided text. The document is for a non-AI/ML device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K242797

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-12-23

    (98 days)

    Product Code
    Regulation Number
    888.3045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    OsteoFlo HydroFiber is a bone void filler intended for use in osseous defects of the skeletal system that are not intrinsic to the stability of the bony structure i.e., the pelvis, intervertebral disc space, and posterolateral spine. These defects may be surgically created or the result of traumatic injury to the bone. OsteoFlo HydroFiber is indicated to be packed gently into bony voids or gaps of the pelvis, posterolateral spine, or intervertebral disc space, and may be used either standalone or in combination with autograft as a bone graft extender. The device is resorbed with host bone during the healing process. When used in intervertebral body fusion procedures. OsteoFlo HydroFiber must be used with an intervertebral body fusion device cleared by FDA for use with a bone void filler.

    Device Description

    OsteoFlo HydroFiber is a resorbable bone void filler comprised of calcium phosphate, bioglass, in a synthetic polymer binder. The OsteoFlo HydroFiber is intended to be easily packed into osseous defects. The single-use device is supplied sterile and dry. The device requires mixing with aqueous solution (autograft, saline, or bone marrow aspirate) prior to use. OsteoFlo HydroFiber may be used as standalone, equivalent to autograft, or in conjunction with autograft.

    AI/ML Overview

    The provided text is a 510(k) summary for the OsteoFlo HydroFiber device. It outlines the device's indications, description, and comparison to predicate devices, focusing on demonstrating substantial equivalence based on non-clinical performance testing.

    However, the document does not contain any information regarding clinical studies or the performance of an AI/software device. Therefore, I cannot provide details on acceptance criteria, expert adjudication, MRMC studies, standalone performance, or ground truth establishment as requested.

    The document primarily focuses on non-clinical performance testing for a bone void filler, which includes:

    • Biocompatibility per ISO 10993-1:2018
    • Sterilization validation per ISO 11137-1:2006 and ISO 11137-2:2013
    • Packaging validation per ISO 11607-1:2009 and ISO 11607-2:2006
    • Shelf-life testing per ASTM 1980-16
    • Material characterization (x-ray diffraction, particle size, particle porosity and surface area)
    • In vivo evaluation in a Lapine Posterolateral Fusion Model

    Without information regarding an AI/software component or human reader studies, I cannot fill out the requested table or answer the specific questions related to AI device performance.

    Ask a Question

    Ask a specific question about this device

    K Number
    K243265

    Validate with FDA (Live)

    Device Name
    Ion 3D
    Manufacturer
    Date Cleared
    2024-12-04

    (50 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Ion 3D Facet Screw may be used in conjunction with the Ion 3D GraftRasp to perform posterior spinal fusion. The Ion 3D GraftRasp may be used to rasp or decorticate bone from the facets and/or transverse processes and for the delivery of hydrated allograft or autograft. The Ion 3D Facet Screw is indicated for the posterior surgical treatment at C2-S1 (inclusive) spinal levels for the following:

    • · Spondylolisthesis
    • · Spondvlolysis
    • · Pseudoarthrosis or failed previous fusions which are symptomatic
      · Degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies and/or degenerative disease of the facet with instability
      The Ion 3D Facet Screw is intended for use with bone graft material (allograft, or autograft).
    Device Description

    The Ion 3D contains various sized facet screws with and without graft windows for bilateral stabilization of the facets from C2-S1. The Ion 3D is provided in various configurations, including single-use, and reusable. The Instruments are offered in sterile and non-sterile configurations. All implants are manufactured from Ti6Al4V per ASTM F136.
    The purpose of this 510(k) is to add new Ion 3D Facet Screws and new instruments to the system.

    AI/ML Overview

    The provided text is a 510(k) Pre-market Notification summary for a medical device (Ion 3D Facet Screw) and does not describe a clinical study with an AI component or detailed performance criteria in the way a diagnostic AI device would. Instead, it focuses on demonstrating substantial equivalence to predicate devices through engineering justifications and non-clinical performance testing.

    Therefore, many of the requested details, such as sample size for test sets, data provenance, number of experts, adjudication methods, MRMC studies, standalone performance, and training set information, are not applicable or available within this document.

    Here's a breakdown of the information that can be extracted and a clear indication of what is not present:

    1. Table of acceptance criteria and reported device performance:

    The document doesn't provide specific numerical acceptance criteria or performance metrics in a table format as would be seen for a diagnostic AI device. Instead, it relies on demonstrating that the device's mechanical performance is not "worst-case" compared to predicates and that it meets standards for biocompatibility and sterilization.

    Performance AspectAcceptance Criteria (Implied)Reported Device Performance
    Mechanical PerformanceNot a new worst-case compared to predicate.Finite element analysis and engineering justifications provided to demonstrate this.
    BiocompatibilityMeets ISO 10993 standards.Biocompatibility Assessment per ISO 10993 was performed.
    SterilizationValidated sterilization process.Sterilization Validation was performed.
    CleaningValidated cleaning process.Cleaning Validation was performed.

    2. Sample size used for the test set and the data provenance:

    • Sample Size for Test Set: Not applicable in the context of this 510(k) submission, as it focuses on non-clinical testing (mechanical, biocompatibility, sterilization, cleaning) rather than a clinical performance study with test data. The "test set" here refers to the physical devices and materials tested.
    • Data Provenance: Not applicable. The testing is primarily laboratory-based and simulated.

    3. Number of experts used to establish the ground truth for the test set and qualifications of those experts:

    • Not applicable. Ground truth as typically understood for AI or diagnostic devices (e.g., expert consensus on pathology images) is not relevant to this type of mechanical and material testing. The "ground truth" for these tests would be the established scientific and engineering principles and standards (e.g., ISO 10993).

    4. Adjudication method for the test set:

    • Not applicable. There is no mention of adjudication, as this type of testing does not involve subjective expert review for establishing ground truth from clinical data.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, ‭If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No. An MRMC study was not conducted. This device is a surgical implant (facet screw) and associated instruments, not an AI-powered diagnostic or assistive tool for human readers.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • No. This device is a physical implant and surgical tools; there is no standalone algorithm to evaluate.

    7. The type of ground truth used:

    • For mechanical performance: Engineering principles and simulation models (Finite Element Analysis) as surrogate for clinical performance under defined loads.
    • For biocompatibility: International standard ISO 10993.
    • For sterilization and cleaning: Industry-accepted validation protocols and standards.

    8. The sample size for the training set:

    • Not applicable. This document refers to a physical medical device, not an AI algorithm that requires a training set.

    9. How the ground truth for the training set was established:

    • Not applicable. No training set is involved for this type of device submission.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242141

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-08-21

    (30 days)

    Product Code
    Regulation Number
    888.3040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TiLink-P SI Joint Fusion System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis.

    Device Description

    The purpose of this Special 510(k) is to introduce the TiLink-P with Window variant to the TiLink-P SI Joint Fusion System. The Window feature is designed to promote osteointegration.

    The TiLink-P SI Joint Fusion System contains various orthopedic instruments to assist the user in implanting a titanium sacroiliac implant into the sacroiliac joint to transfix the joint. The SurGenTec TiLink-P SI Joint Fixation System includes TiLink Implants and associated Instruments. The TiLink-P implants may be used standalone. The TiLink-P SI Joint Fusion System fixates the sacroiliac joint by transfixing the cortices of the ilium and cortices of the sacrum.

    The TiLink-P Compression Anchor is positioned so that it spans the cortices of ilium and cortices of sacrum, the TiLink-P Locking Screw is inserted through the TiLink-P Compression Anchor and along the SI Joint via a posterior approach, in order to compress the joint. Bone graft material is used with the TiLink-P SI Joint Fusion System to facilitate bone growth.

    AI/ML Overview

    The FDA letter provided is a clearance letter for a medical device (TiLink-P SI Joint Fusion System), not an AI/ML device. Therefore, the document does not contain information about acceptance criteria or studies pertaining to AI/ML device performance. The information requested regarding sample sizes, expert ground truth, adjudication methods, MRMC studies, standalone performance, and training data is not applicable to the content of this document.

    The document discusses the substantial equivalence of the "TiLink-P SI Joint Fusion System" to a predicate device (TiLink-P Joint Fusion System K240720) through mechanical strength tests.

    Here is the information that is available in the document:

    1. A table of acceptance criteria and the reported device performance

    The document states that performance testing was conducted according to specific ASTM standards to demonstrate substantial equivalence to the predicate device. However, it does not provide a table of acceptance criteria (e.g., specific thresholds for pullout strength or shear strength) nor the reported numerical performance data. It only lists the types of tests performed.

    Acceptance CriteriaReported Device Performance
    Not specified in the document (Implied: To be substantially equivalent to predicate device as measured by ASTM F543 and ASTM F3574)"demonstrates substantial equivalence to the predicate device."
    Axial Pullout per ASTM F543Testing performed
    Static and Dynamic Vertical Shear per ASTM F3574Testing performed

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    Not applicable. The "test set" here refers to physical devices for mechanical testing, not a dataset for an AI/ML model. The document does not specify the number of devices tested. Data provenance such as country of origin or retrospective/prospective is not relevant for this type of device clearance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. Ground truth as typically understood in AI/ML (e.g., expert labels on images) is not relevant for this type of mechanical device testing. The "ground truth" for mechanical testing is derived from established engineering principles and ASTM standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. Adjudication methods are typically used for resolving disagreements among human experts in labeling datasets, which is not relevant for mechanical testing.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a clearance for a physical medical implant, not an AI/ML diagnostic or assistive device. No MRMC study was conducted.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Not applicable. For mechanical testing, the "ground truth" is provided by the established ASTM standards and the physical properties and performance of the predicate device.

    8. The sample size for the training set

    Not applicable. There is no AI/ML model, and therefore no training set.

    9. How the ground truth for the training set was established

    Not applicable. There is no AI/ML model, and therefore no training set or ground truth for a training set.

    Ask a Question

    Ask a specific question about this device

    K Number
    K240664

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-08-09

    (154 days)

    Product Code
    Regulation Number
    876.1075
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ALARA BMA Neuro Access Kit (ALARA BMAN and ALARA BMAC Kit) is indicated for aspiration of bone marrow or autologous blood.

    The ALARA BMA Neuro Access Kit is indicated for pedicle pilot hole preparation, locating, and identifying spinal roots / nerves by providing proximity feedback.

    Device Description

    The ALARA BMA Neuro Access Kit utilizes a neuromonitoring platform in providing the surgeon with nerve / root location feedback during the approach to a pedicle to support a guidewire placement.

    The ALARA BMAN and ALARA BMAC Kit includes various single-use needles designed for bone marrow aspiration and aspiration of autologous blood.

    AI/ML Overview

    The provided text describes the regulatory clearance of the ALARA BMA Neuro Access Kit, focusing on its substantial equivalence to predicate devices based on design, materials, and non-clinical testing. However, it does not include acceptance criteria, reported device performance, or details of a study that proves the device meets specific performance criteria.

    Therefore, I cannot populate the table or answer questions 2 through 9 based on the provided document. The document primarily focuses on regulatory approval based on comparison to existing legally marketed devices, rather than a detailed performance study against predefined acceptance criteria.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241416

    Validate with FDA (Live)

    Device Name
    Ion 3D
    Manufacturer
    Date Cleared
    2024-06-17

    (31 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Ion 3D Facet Screw may be used in conjunction with the Ion 3D GraftRasp to perform posterior spinal fusion. The Ion 3D GraftRasp may be used to rasp or decorticate bone from the facets and/or transverse and for the delivery of hydrated allograft or autograft.

    The Ion 3D Facet Screw is indicated for the posterior surgical treatment at C2-S1 (inclusive) spinal levels for the following:

    • · Spondylolisthesis
    • · Spondylolysis
    • · Pseudoarthrosis or failed previous fusions which are symptomatic

    · Degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies and/or degenerative disease of the facet with instability

    The Ion 3D Facet Screw is intended for use with bone graft material (allograft, or autograft).

    Device Description

    The Ion 3D contains various sized facet screws with and without graft windows, for bilateral stabilization of the facets from C2-S1. The Ion 3D is provided in various configurations, including single-use, and reusable. The Instruments are offered in sterile and non-sterile configurations. All implants are manufactured from Ti6Al4V per ASTM F136.

    AI/ML Overview

    The provided document does not contain information related to software or AI-driven medical devices. The focus of this 510(k) submission is on a physical medical device, the "Ion 3D Facet Screw," and its accessories. The performance testing described is mechanical (e.g., axial pushout, static and dynamic three-point bend testing) to demonstrate the structural integrity and functionality of the physical screw and graft rasp.

    Therefore, the requested information regarding acceptance criteria for device performance related to a study, the sample size for a test set, data provenance, expert ground truth, adjudication methods, MRMC studies, standalone algorithm performance, and ground truth establishment for training sets is not applicable to this document. These details are typically required for the validation of diagnostic or AI-based devices, not for the mechanical testing of an orthopedic implant.