Search Filters

Search Results

Found 4 results

510(k) Data Aggregation

    K Number
    K233877

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-03-04

    (88 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The XT2 power wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position who have the capability of operating a power wheelchair. The XT4 power wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position who have the capability of operating a power wheelchair.

    Device Description

    The XT Series Power Wheelchair has two configurations: XT2 and XT4. They are designed for everyday use for both indoor and outdoor environments including care facilities and private residences. The subject device is intended to provide mobility to persons who are restricted or limited to a sitting position. The XT Series Power Wheelchairs are battery powered, electric motor driven devices that can be used on both indoor and outdoor surfaces (i.e., concrete, asphalt, indoor flooring such as carpet, gravel, grass, and bark/woodchips). The XT Series Power Wheelchair offers two basic seating options: MPS and Rehab. The MPS option is more static and does not allow for additional aftermarket cushions. The Rehab option is more adjustable to adhere to recommendations from the user's physician or physical therapist.

    AI/ML Overview

    The provided document is an FDA 510(k) clearance letter and summary for a Magic Mobility XT Series Power Wheelchair. It details the device's technical specifications, indications for use, and a comparison to predicate devices, along with the non-clinical testing performed to establish substantial equivalence.

    However, the document does not contain any information about an AI/ML-based medical device, nor does it include details about a study conducted to demonstrate its performance against specific acceptance criteria for such a device. The device described, a powered wheelchair, is a physical medical device, not a software or AI-driven diagnostic or therapeutic tool that would typically have acceptance criteria related to accuracy, sensitivity, specificity, or human-in-the-loop performance improvement.

    Therefore, I cannot provide the requested information regarding acceptance criteria and a study proving an AI/ML device meets them, a sample size, expert qualifications, ground truth establishment, or MRMC studies, as these concepts are not applicable to the content of the provided document.

    The document focuses on non-clinical bench testing to demonstrate the safety and effectiveness of the physical wheelchair in comparison to existing predicate devices, primarily through adherence to ISO standards for wheelchairs.

    To directly answer your prompt, based on the provided text:

    1. A table of acceptance criteria and the reported device performance:

    • This document does not present acceptance criteria or reported performance for an AI/ML device. It lists various ISO standards that the physical wheelchair was tested against. The "reported device performance" is essentially that it met these standards, thus demonstrating substantial equivalence to predicate devices. For example, for "Static stability," the acceptance criterion is compliance with ISO 7176-1, and the reported performance is implicit compliance as it contributed to the substantial equivalence determination.
    Acceptance Criterion (Implicitly Compliance with Standard)Reported Device Performance (Implicitly Met)
    ISO 7176-1: Static stabilityMet standard
    ISO 7176-2: Dynamic stabilityMet standard
    ISO 7176-3: Effectiveness of brakesMet standard
    ISO 7176-4: Energy consumptionMet standard
    ISO 7176-5: Dimensions, mass, and maneuvering spaceMet standard
    ISO 7176-6: Maximum speed, acceleration, and decelerationMet standard
    ISO 7176-7: Measurement of seat and wheel dimensionsMet standard
    ISO 7176-8: Static, impact, and fatigueMet standard
    ISO 7176-9: Climatic testMet standard
    ISO 7176-10: Obstacle climbingMet standard
    ISO 7176-11: Test dummiesMet standard
    ISO 7176-14: Power and control systemsMet standard
    ISO 7176-15: Documentation and labelingMet standard
    ISO 7176-16: Resistance to ignitionMet standard
    ISO 7176-19: Dynamic TestMet standard
    ISO 7176-26: VocabularyMet standard
    ISO 7176-30: Wheelchairs for changing postureMet standard
    ISO 7176-21: EMC testingMet standard
    ISO 7176-25: Batteries and chargersMet standard
    ISO 10993-1: BiocompatibilityMet standard (via material commonality)
    IEC 62304: Software life cycle processMet standard

    2. Sample size used for the test set and the data provenance:

    • Not applicable/Not provided for an AI/ML device. The "test set" here refers to the physical wheelchairs undergoing bench testing. The sample size for such physical product testing is not specified, but typically involves a small number of units. Data provenance (country of origin, retrospective/prospective) is not relevant for this type of medical device testing.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable. "Ground truth" in the context of an AI/ML device's performance (e.g., disease detection) is not established for a physical powered wheelchair. The "truth" for this device is its adherence to engineering standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    • Not applicable. This is a concept for reconciling disagreements among human readers in a diagnostic AI/ML study, not for physical product testing.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No, an MRMC study was not done as this is a physical wheelchair, not an AI/ML diagnostic or assistive device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    • Not applicable. There is no AI algorithm being submitted for standalone performance evaluation in this document.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • Not applicable in the context of AI/ML. The "ground truth" for this device's performance is adherence to established international engineering and safety standards (e.g., ISO, IEC).

    8. The sample size for the training set:

    • Not applicable. This document does not describe an AI/ML device, so there is no training set for an algorithm.

    9. How the ground truth for the training set was established:

    • Not applicable for the same reason as above.
    Ask a Question

    Ask a specific question about this device

    K Number
    K213090

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2021-11-19

    (56 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Frontier Series Power Wheelchairs are battery-operated devices with wheels that are intended for medical purposes to provide mobility to persons restricted to a sitting position who have the capability of operating a power wheelchair.

    Device Description

    The Frontier Series Power Wheelchairs have four configurations: V4 RWD, V4 FWD, V6, and C73. The Frontier Series Power Wheelchairs are designed for everyday use for both indoor and outdoor environments including care facilities and private residences. The subject devices are intended to provide mobility to persons who are restricted or limited to a sitting position. The Frontier Series Power Wheelchairs are battery powered, electric motor driven devices that can be used on both indoor and outdoor surfaces (i.e., concrete, asphalt, indoor flooring such as carpet, gravel, grass, and bark/woodchips).

    AI/ML Overview

    This is a 510(k) premarket notification for the "Frontier Series Power Wheelchairs". This document is a submission to the FDA to demonstrate that the new device is "substantially equivalent" to already legally marketed predicate devices. Therefore, the "acceptance criteria" here refers to the performance of the device relative to established standards and the predicate devices, rather than strict statistical thresholds for an AI algorithm.

    1. A table of acceptance criteria and the reported device performance

    The acceptance criteria are established by adherence to recognized international standards and comparison to predicate devices, showing that any differences do not affect safety or effectiveness. The reported device performance is demonstrated by meeting these standards and having similar or identical characteristics to the predicate devices.

    Acceptance Criteria / Performance MetricReported Device Performance / Evaluation
    Indications for Use (Substantial Equivalence)The Frontier Series Power Wheelchairs are battery-operated devices with wheels that are intended for medical purposes to provide mobility to persons restricted to a sitting position who have the capability of operating a power wheelchair. This is described as "Substantially equivalent to predicate devices."
    Product Codes / Regulation Number (Substantial Equivalence)ITI / 21 CFR 890.3860. Described as "Identical to the primary predicate. No impact on safety and effectiveness."
    Regulation Description (Substantial Equivalence)Powered Wheelchair. Described as "Identical to the primary predicate. No impact on safety and effectiveness."
    Maximum User Weight (Substantial Equivalence)Frontier V4 FWD: 400 lbs, Frontier V4 RWD: 400 lbs, Frontier V6: 400 lbs, Frontier V6 C73: 400 lbs. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Primary predicate K030783 also 400 lbs).
    Storage Temperature (Substantial Equivalence)-40 to 70 °C. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Primary predicate K030783 also -40 to 70 °C).
    Location for Use (Substantial Equivalence)Indoors and outdoors including care facilities, and residences. Described as "Identical to the primary predicate. No impact on safety and effectiveness."
    Frame Material (Substantial Equivalence)Steel. Described as "Identical to the primary predicate." (Primary predicate K030783 also Steel).
    Base Overall Dimensions (Substantial Equivalence)Varied across models (e.g., Frontier V4 FWD AT tires: 39.2 x 28 inches). Described as "Substantially equivalent to the predicate and reference devices. No impact on safety and effectiveness."
    Rolling Base Weight (Substantial Equivalence)260 lbs (with batteries). Described as "Substantially equivalent to the predicate device. No impact on safety and effectiveness." (Primary predicate K030783: 130 lbs; K142457: 152 lbs) - Note: While a difference exists, the claim is "No impact on safety and effectiveness.".
    Power Source (Substantial Equivalence)Batteries. Described as "Identical to the primary predicate. No impact on safety and effectiveness."
    Battery Details (Substantial Equivalence)Two (2) 73 Ahr. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Reference device K172384: 24V (2x12V)/73 Ah/20h).
    Castor Wheel Size (Substantial Equivalence)8.25 x 2.5 inches. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Predicate K030783 and K142457 listed as 'Unknown').
    Range (Substantial Equivalence)15-20 miles. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Predicate K030783 and K142457 listed as 'Unknown').
    Anti-pitch Mechanism for Climbing (Substantial Equivalence)None. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Predicates K030783 and K142457: "Additional anti-pitch lock out"). Note: This is a stated difference with the predicate, but claimed "No impact on safety and effectiveness.".
    Lift Range (Substantial Equivalence)0-12 inches. Described as "Identical to the primary predicate. No impact on safety and effectiveness."
    Tilt Range (Substantial Equivalence)0-50 degrees. Described as "Identical to the primary predicate. No impact on safety and effectiveness."
    Recline Range (Substantial Equivalence)0-170 degrees. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Reference device K172384: 0-172 degrees - Note: claimed identical despite slight difference).
    Suspension (Substantial Equivalence)Independent drive wheel suspension with shock absorber on pivoting swing arm and articulated castors to ensure all wheels maintain adhesion at all surface angles. Described as "Identical to the primary predicate. No impact on safety and effectiveness."
    Maximum Speed (Substantial Equivalence)6 mph. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Reference device K172384: 6 mph (with an option of 8)).
    Minimum Braking Distance at Maximum Speed (Substantial Equivalence)1.8 meters. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Predicate K030783 and K142457 listed as 'Unknown').
    User Controller (Substantial Equivalence)Joystick and hand control buttons. Described as "Identical to the primary predicate. No impact on safety and effectiveness."
    Joystick Mount (Substantial Equivalence)Joystick and hand control buttons (implies variable, but then states Fixed mount, height adjustable, swing-away). Described as "Identical to the predicate and reference devices. No impact on safety and effectiveness."
    Software (Substantial Equivalence)R-Net from PGDT. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Primary predicate K030783 uses VR2 from PGDT; Reference device K172384 uses R-Net from PGDT). Note: This is a stated difference with the primary predicate, but claimed "No impact on safety and effectiveness" due to similarity to the reference device.
    Seat Height (minimum, inches) (Substantial Equivalence)17.1 inches. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Primary predicate K030783: 16.2 inches). Note: claimed identical despite slight difference.
    Seat Width (inches) (Substantial Equivalence)16-24 inches. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Primary predicate K030783: 12-24 inches).
    Armrest (Substantial Equivalence)Height adjustable, removable, flip up option. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Predicate K030783 and K142457 listed as 'Unknown').
    Footrest (Substantial Equivalence)Rigid footplate, flip up nylon. Described as "Identical to the primary predicate. No impact on safety and effectiveness." (Predicate K030783 and K142457 listed as 'Unknown').
    Static stability (per ISO 7176-1)Performed. Results indicated substantial equivalence.
    Dynamic stability (per ISO 7176-2)Performed. Results indicated substantial equivalence.
    Effectiveness of brakes (per ISO 7176-3)Performed. Results indicated substantial equivalence.
    Energy consumption (per ISO 7176-4)Performed. Results indicated substantial equivalence.
    Dimensions, mass, and maneuvering space (per ISO 7176-5)Performed. Results indicated substantial equivalence.
    Maximum speed, acceleration, and deceleration (per ISO 7176-6)Performed. Results indicated substantial equivalence.
    Measurement of seat and wheel dimensions (per ISO 7176-7)Performed. Results indicated substantial equivalence.
    Static, impact, and fatigue (per ISO 7176-8)Performed. Results indicated substantial equivalence.
    Climatic test (per ISO 7176-9)Performed. Results indicated substantial equivalence.
    Obstacle climbing (per ISO 7176-10)Performed. Results indicated substantial equivalence.
    Test dummies (per ISO 7176-11)Performed. Results indicated substantial equivalence.
    Power and control systems for power wheelchairs (per ISO 7176-14)Performed. Results indicated substantial equivalence.
    Documentation and labeling (per ISO 7176-15)Performed. Results indicated substantial equivalence.
    Resistance to ignition (per ISO 7176-16)Performed. Results indicated substantial equivalence.
    Dynamic Test (per ISO 71716-19)Performed. Results indicated substantial equivalence.
    Vocabulary (per ISO 7176-26)Performed. Results indicated substantial equivalence.
    EMC testing (per ISO 7176-21)Performed. Results indicated substantial equivalence.
    Batteries and chargers per (per ISO 7176-25)Performed. Results indicated substantial equivalence.
    Biocompatibility (per ISO 10993-1 and ISO 10993-5)Uses materials identical in composition, formulation processing, sterilization, and geometry to predicate devices. Same nature of tissue contact and duration. Also, "in vitro cytotoxicity (per ISO 10993-5)" was performed. Considered to have met requirements.
    Software life cycle process (per IEC 62304)Performed. Results indicated substantial equivalence.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This submission describes non-clinical performance and engineering testing on the device prototypes, not a clinical study on human subjects with a test set of data in the traditional sense of an AI/imaging device. The "test set" would be the physical Frontier Series Power Wheelchairs themselves, subjected to various standardized tests. No specific numerical sample size (e.g., how many wheelchairs were tested for each test) is provided in the document, other than implying the testing of "the subject devices." The provenance is manufacturing in Australia. The testing is presumably prospective for the purpose of this 510(k) submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable to this type of device submission. Ground truth, in the context of this 510(k), refers to the established standards (e.g., ISO 7176 series, ISO 10993 series, IEC 62304) and the performance characteristics of the predicate devices. The "experts" are the creators of these standards, and the engineers/testers who conduct measurements and compare the device's performance against these benchmarks and the predicate devices' specifications. No specific number or qualifications of such 'experts' are provided in this document beyond the general statement of "testing performed."

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This is not applicable. The evaluation is based on objective measurements against engineering standards and comparison of technical specifications to predicate devices, not subjective assessments requiring adjudication by multiple readers.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This is not applicable as the device is a power wheelchair, not an AI-assisted diagnostic or therapeutic tool that involves human readers or interpretation of medical cases.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This is not applicable. This is a physical medical device (power wheelchair), not an algorithm or AI system.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    The "ground truth" for this submission is established by:

    • International Standards: Complying with numerous ISO and IEC standards for wheelchairs (e.g., ISO 7176-1 for static stability, ISO 10993-1 for biocompatibility, IEC 62304 for software life cycle).
    • Predicate Device Performance: Demonstrating that the subject device's technological characteristics and performance are similar or identical to legally marketed predicate devices, or that any differences do not raise new questions of safety or effectiveness.

    8. The sample size for the training set

    This is not applicable as the device is a physical power wheelchair, not an AI algorithm trained on a dataset. The design and manufacturing process would involve engineering iterations and testing, but not a "training set" in the context of machine learning.

    9. How the ground truth for the training set was established

    Not applicable. As described above, this is about adherence to engineering standards and comparison to predicate devices, not machine learning ground truth.

    Ask a Question

    Ask a specific question about this device

    K Number
    K211574

    Validate with FDA (Live)

    Device Name
    Extreme X8
    Manufacturer
    Date Cleared
    2021-07-09

    (49 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Extreme X8 Power Wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position who have the capability of operating a power wheelchair.

    Device Description

    The Extreme X8 Power Wheelchair is designed for everyday use for both indoor and outdoor environments including care facilities and private residences. The subject device is intended to provide mobility to persons who are restricted or limited to a sitting position. The Extreme X8 Power Wheelchair is a battery powered, electric motor driven device that can be used on both indoor and outdoor surfaces (i.e., concrete, asphalt, indoor flooring such as carpet, gravel, grass, and bark/woodchips).The Extreme X8 Power Wheelchair offers two basic seating options: MPS and Rehab. The MPS option is more static and does not allow for additional aftermarket cushions. The Rehab option is more adjustable to adhere to recommendations from the user's physician or physical therapist.

    AI/ML Overview

    The provided text is a 510(k) summary for a powered wheelchair, not an AI/ML medical device. Therefore, the information requested in the prompt, which is specific to AI/ML device studies (e.g., sample size for test set, number of experts for ground truth, adjudication method, MRMC studies, standalone performance, training set sample size), is not applicable and cannot be extracted from this document.

    The document discusses the substantial equivalence of the "Extreme X8 Power Wheelchair" to a predicate device, focusing on non-clinical testing for performance, EMC and electrical safety, biocompatibility, and software in the context of general medical device safety and effectiveness.

    Here's a breakdown of the relevant information provided, tailored to the context of a non-AI/ML medical device for which the prompt's questions are not appropriate:

    1. Acceptance Criteria and Reported Device Performance:

    The acceptance criteria are implicitly defined by compliance with various ISO standards for wheelchairs. The reported device performance is that the "Extreme X8 Power Wheelchair has undergone testing to ensure that any differences in technological characteristics (i.e., battery, castor wheels, and no anti-pitch mechanism) do not affect safety and effectiveness when compared to the predicate device."

    Acceptance Criteria (Standard Compliance)Reported Device Performance
    ISO 7176-1 (Static stability)Met, indicated by substantial equivalence to predicate device
    ISO 7176-2 (Dynamic stability)Met, indicated by substantial equivalence to predicate device
    ISO 7176-3 (Effectiveness of brakes)Met, indicated by substantial equivalence to predicate device
    ISO 7176-4 (Energy consumption)Met, indicated by substantial equivalence to predicate device
    ISO 7176-5 (Dimensions, mass, maneuvering)Met, indicated by substantial equivalence to predicate device
    ISO 7176-6 (Max speed, accel, decel)Met, indicated by substantial equivalence to predicate device
    ISO 7176-7 (Seat & wheel dimensions)Met, indicated by substantial equivalence to predicate device
    ISO 7176-8 (Static, impact, fatigue)Met, indicated by substantial equivalence to predicate device
    ISO 7176-9 (Climatic test)Met, indicated by substantial equivalence to predicate device
    ISO 7176-10 (Obstacle climbing)Met, indicated by substantial equivalence to predicate device
    ISO 7176-11 (Test dummies)Met, indicated by substantial equivalence to predicate device
    ISO 7176-14 (Power & control systems)Met, indicated by substantial equivalence to predicate device
    ISO 7176-15 (Documentation & labeling)Met, indicated by substantial equivalence to predicate device
    ISO 7176-16 (Resistance to ignition)Met, indicated by substantial equivalence to predicate device
    ISO 7176-19 (Dynamic Test)Met, indicated by substantial equivalence to predicate device
    ISO 7176-26 (Vocabulary)Met, indicated by substantial equivalence to predicate device
    ISO 7176-21 (EMC testing)Met, indicated by substantial equivalence to predicate device
    ISO 7176-25 (Batteries and chargers)Met, indicated by substantial equivalence to predicate device
    ISO 10993-1 (Biocompatibility eval.)Met, based on previous use and cytotoxicity testing conducted
    ISO 10993-5 (In vitro cytotoxicity)Met, based on previous use and cytotoxicity testing conducted
    IEC 62304 (Software life cycle process)Met, indicated by substantial equivalence to predicate device

    The study proving the device meets these criteria is the non-clinical testing summarized in the "Summary of Non-Clinical Testing" section. This testing demonstrated that the Extreme X8 Power Wheelchair does not raise new issues of safety or effectiveness compared to the predicate device, leading to a conclusion of substantial equivalence.

    The following numbered points from the prompt cannot be answered as they pertain to AI/ML device studies, and this document is for a physical medical device (powered wheelchair):

    1. Sample sizes used for the test set and the data provenance.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts.
    3. Adjudication method for the test set.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc).
    7. The sample size for the training set.
    8. How the ground truth for the training set was established.
    Ask a Question

    Ask a specific question about this device

    K Number
    K203083

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2021-03-17

    (155 days)

    Product Code
    Regulation Number
    890.3860
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Magic 360 Power Wheelchair is a battery-operated device with wheels that is intended for medical purposes to provide mobility to persons restricted to a sitting position who have the capability of operating a power wheelchair.

    Device Description

    The Magic 360 Power Wheelchair is designed for everyday use for both indoor and outdoor environments including care facilities and private residences. The subject device is intended to provide mobility to persons that are restricted or limited to a sitting position.

    The Magic 360 Power Wheelchair is a battery powered, electric motor driven device that can be used on both indoor and outdoor surfaces (i.e. concrete, asphalt, indoor flooring, gravel, grass, and bark). The subject device has two seat options: MPS and rehab. The rehab seat option has more built-in adjustments (i.e., width and depth adjustments) and allows for aftermarket cushions. All the wheelchairs include the same power seating options including lift, tilt, recline, and leg elevation to ensure the user to find a position that is comfortable.

    The Magic 360 Power Wheelchair includes the following accessories:

    • Extra spreader bar
    • Slide in table
    • Lights
    • Luggage rack
    • Accessory charger ●
    • Posture belt
    • Roho cushion
    • Jay cushion
    • MPS push rail
    • MPS peg push handle
    • Scooter stopper ●
    • Retractable docking pin
    • Fold forward kit

    Please note, the fold forward kit is an accessory which allows the user to fold the wheelchair and put the wheelchair in a car. To fold the wheelchair the user pulls the red release handle located at the back of the Magic 360 Power Wheelchair. To unfold the wheelchair the user pulls the frame back into place using the armrests.

    AI/ML Overview

    The provided text is a 510(k) summary for the Magic 360 Power Wheelchair. This document is a regulatory submission to the FDA for medical device clearance, not a study evaluating an AI algorithm's performance. Therefore, most of the requested information regarding acceptance criteria and a study proving device meets acceptance criteria is not directly applicable in the AI/ML context.

    However, I can extract the closest analogous information from the document as it pertains to a traditional medical device (power wheelchair).

    Here's an interpretation based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not present a table of specific acceptance criteria with quantitative performance metrics for the Magic 360 Power Wheelchair in the way one would for an AI algorithm (e.g., sensitivity, specificity thresholds). Instead, the "acceptance criteria" are implied by adherence to recognized ISO standards for wheelchairs and demonstrating substantial equivalence to predicate devices. The "reported device performance" is inferred from the successful completion of these tests.

    The comparison table provided in the document (pages 6-7) highlights the characteristics of the Magic 360 Power Wheelchair against predicate devices. The "Statement of Equivalence" column implicitly indicates that the device's performance characteristics are either identical or substantially equivalent to the predicate devices, thus meeting regulatory expectations.

    CategoryAcceptance Criteria (Implied)Reported Device Performance (Implied from "Statement of Equivalence")
    Indications for UseMust be identical or substantially similar to predicate device(s) without raising new questions of safety or effectiveness."Identical to primary predicate. No impact on safety or effectiveness."
    Product Codes / Regulation No.Must align with predicate device(s)."Identical to primary and secondary predicate. No impact on safety and effectiveness."
    Regulation DescriptionMust align with predicate device(s)."Identical to primary and secondary predicate. No impact on safety and effectiveness."
    Maximum User Weight (lbs)Must be within acceptable limits compared to predicate(s) and demonstrate safety and effectiveness for stated weight."Identical to primary predicate. No impact on safety and effectiveness." (300 lbs)
    Storage Temperature (°C)Must meet relevant standards for safe storage."Identical to primary predicate and reference devices. No impact on safety and effectiveness." (-40 to 70 °C)
    Location for UseMust be comparable to predicate(s) or justified through testing for safety and effectiveness."Identical to predicate and reference devices. No impact on safety and effectiveness." (Indoors and outdoors including care facilities, residences, and soft/rough terrain)
    Frame MaterialMust be biocompatible and structurally sound."Identical to primary predicate and reference devices. No impact on safety and effectiveness." (Steel and aluminum)
    BiocompatibilityMaterials must be common to many wheelchairs and pass relevant ISO standards."Identical to predicate and reference devices. No impact on safety and effectiveness." (Uses materials common to many wheelchairs and passed ISO 10993 tests)
    Maximum Speed (mph)Must be comparable to predicate(s) and safe."Identical to primary predicate. No impact on safety and effectiveness." (6 mph)
    Base Overall DimensionsMust be within a range that demonstrates substantial equivalence and does not negatively impact safety or effectiveness."Substantially equivalent to the predicate and reference devices. No impact on safety and effectiveness." (26"x38.7")
    Rolling Base Weight (lbs)Must be comparable to predicate(s) and demonstrate safety and effectiveness."Identical to primary predicate. No impact on safety and effectiveness." (130 lbs)
    Power SourceMust be safe and effective."Identical to predicate and reference devices. No impact on safety and effectiveness." (Batteries)
    Battery DetailsMust be safe and effective, and comparable to predicate(s)."Identical to secondary predicate and reference devices. No impact on safety and effectiveness." (24V (2x12V) / 73 Ah/20h, similar to K181908 and K172384)
    Drive Wheel Diameter (inches)Must be comparable to predicate(s) and not negatively impact safety or effectiveness."Identical to reference device. No impact on safety and effectiveness." (14 inches)
    Castor Wheel Size (inches)Must be comparable to predicate(s) and not negatively impact safety or effectiveness."Substantially equivalent to the primary predicate and reference devices. No impact on safety and effectiveness." (Front 8", Rear 8")
    Anti-pitch MechanismFunctionality should be comparable to predicate(s) or justified for safety and effectiveness without one. The subject device has "None" but is deemed substantially equivalent based on testing for differences in technological characteristics."Substantially equivalent to the primary predicate and reference devices. No impact on safety and effectiveness." (None, despite predicates having additional anti-pitch lock out; testing justifies this difference)
    Range (miles)Must be comparable to predicate(s)."Substantially equivalent to the predicate and reference devices. No impact on safety and effectiveness." (22.5 miles)
    Lift Range (inches)Must be comparable to predicate(s)."Identical to primary predicate and reference devices. No impact on safety and effectiveness." (0-12 inches)
    Tilt Range (degrees)Must be comparable to predicate(s)."Identical to primary predicate and reference devices. No impact on safety and effectiveness." (0-50 degrees)
    Recline Range (degrees)Must be comparable to predicate(s)."Identical to primary predicate and reference devices. No impact on safety and effectiveness." (0-170 degrees)
    SuspensionMust provide equivalent safety and effectiveness to predicate(s)."Substantially equivalent to the primary predicate and reference devices. No impact on safety and effectiveness." (Independent drive wheel suspension with shock absorbers)
    Type of Braking SystemMust be safe and effective."Identical to the primary predicate. No impact on safety and effectiveness." (Electromagnetic, regenerative brakes with a free-wheeling mode)
    User ControllerMust be safe and effective and provide appropriate control."Identical to primary predicate and reference devices. No impact on safety and effectiveness." (Joystick and hand control buttons)
    Joystick MountMust be safe and provide appropriate adjustability."Identical to primary predicate and reference devices. No impact on safety and effectiveness." (Fixed mount, height adjustable, swing-away)
    Folding mechanismMust be safe and effective, and comparable to predicate(s)."Substantially equivalent to the primary predicate. No impact on safety and effectiveness." (Yes, with fold forward kit accessory)
    SoftwareMust be safe and effective, and comparable to predicate(s)."Identical to reference device. No impact on safety and effectiveness." (R-Net from PGDT)
    Seat Height (minimum, inches)Must be within a range that demonstrates substantial equivalence and does not negatively impact safety or effectiveness."Substantially equivalent to the predicate and reference devices. No impact on safety and effectiveness." (17.1 inches)
    Seat Width (inches)Must be within a range that demonstrates substantial equivalence and does not negatively impact safety or effectiveness."Substantially equivalent to the primary predicate and reference devices. No impact on safety and effectiveness." (12-22 inches)
    ArmrestMust provide equivalent safety and effectiveness to predicate(s)."Identical to the primary predicate. No impact on safety and effectiveness." (Height adjustable, removable, flip up option)
    FootrestMust provide equivalent safety and effectiveness to predicate(s)."Substantially equivalent to the predicate devices. No impact on safety and effectiveness." (1 or 2 pieces, fixed or flip up, angle and height adjustable rigid footplates)
    ISO Standards ComplianceMust meet all relevant ISO standards for wheelchairs."The results of these tests indicate that the Magic 360 Power Wheelchair are substantially equivalent to the predicate devices." (Passed 20+ ISO tests and biocompatibility tests as listed in "SUMMARY OF NON-CLINICAL TESTING")

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided because this is a submission for a physical medical device (power wheelchair) and not an AI/ML algorithm. The "test set" in this context refers to physical units of the wheelchair undergoing standardized engineering and performance tests, not a dataset for an algorithm. There is no mention of "data provenance" in the sense of patient data. The manufacturer is based in Australia ("3 International Court, Scoresby, VIC, 3179 Australia").

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This is not applicable to this type of device submission. "Ground truth" in this context would implicitly be the established engineering specifications and performance requirements defined by ISO standards and regulatory guidelines, confirmed through physical testing by qualified engineers or technicians.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. This concept relates to human review of data, which is not described for the performance testing of this physical device. The testing described (e.g., Static stability, Dynamic stability, EMC testing) are objective engineering measurements against defined standards.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is not an AI-assisted device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is not an AI algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" for this medical device's performance is established by international consensus standards (ISO standards) for wheelchairs regarding functionality, safety, and durability, as well as the performance characteristics of legally marketed predicate devices. The testing verifies that the device performs according to these objective standards and is comparable to equivalent devices already on the market.

    8. The sample size for the training set

    Not applicable. This is not an AI/ML device, so there is no "training set." The device is designed, manufactured, and tested to engineering specifications.

    9. How the ground truth for the training set was established

    Not applicable, as there is no training set mentioned in the context of an AI/ML algorithm.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1