Found 3 results

510(k) Data Aggregation

    K Number
    K112758

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2012-02-23

    (154 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    KAT Implants System is intended to restore edentulous areas of maxilla and mandible, to provide support for removable dentures, fixed bridges, or to be used as a single tooth replacement. Single or splinted implants can be immediately loaded if good primary stability and appropriate occlusal loading are achieved. The implant can be placed in extraction sites or healed alveolar ridges. KAT Implants System 2.5mm implants are self-tapping titanium alloy threaded screws indicated for transitional and long-term intra-bony applications, such as providing support for transitional or long term crowns, bridges and dentures. KAT Implants System 2.5mm implants may also be used for inter-radicular transitional application.

    KAT Implants System 3.0mm implants are indicated for use in maxillary lateral or mandibular lateral and central incisors in single or multiple units to support prosthesis, such as artificial teeth. The implant can be placed in extraction sites or healed alveolar ridges and can be immediately loaded when good primary stability is achieved and the functional load is appropriate.

    KAT Implants System Abutments are intended to be used with KAT Implants System Dental Implants aid in prosthetic rehabilitation of the edentulous areas in maxilla and mandible.

    Device Description

    Like the predicate KAT Implants 2.5mm and 3.0mm KAT Implants System Onepiece implants 2.5mm and 3.0mm display the following characteristics: a) have a threaded body and a tapered post with an internal threaded bore, b) have the same indications, c) are manufactured from the same material (Ti6Al4V ELI alloy), c) have the same diameters (2.5 and 3.0mm) and implant body lengths (10, 12 and 14mm), d) are packaged with the same materials and undergo the same sterilization process. KAT Implants System One-piece implants 2.5mm and 3.0mm implants are not designed to receive any abutments; they are designed to receive the crowns directly via cementation procedure. KAT Implants System One-piece implants are blasted with a soluble tricalcium phosphate blasting media. All materials and manufacturing processes are the same for all KAT Implants System Dental Implants. The fatigue testing was executed per ISO 14801:2007, Dentisty - Implants - Dynamic fatigue testing on endosseous dental implants on a 4.2mm width by 8.5mm length abutment with 20 ° angularity and a 3.0mm diameter implant, which is considered worst-case representation for KAT Implants System implants having 3.0mm or greater diameter. In view of a fatigue test results (samples were able to withstand 440 N of force over 5 million cvcles) and considering the fact that KAT Implants System One-piece Implants 3.0 and predicate KAT Implants System 3.0mm implants (K083544) have identical dimensions, no further fatigue testing was deemed necessary.

    Predicate one-piece implant devices (IMTEC Sedax MDI 1.8mm and Maximus 3.0mm Diameter Implant) are the same as One-piece implants 2.5 and 3.0 in respect to material composition, surface treatment, diameters and lengths (for the exception of One-piece implant 3.0 x 10). Predicate Maximus 3.0mm Diameter Implant is not provided in 10 mm length, but another predicate - KAT 3.0mm implant cleared under K083544 is provided in 10 mm length.

    Since predicate KAT Implants System 2.5mm implants (K083544) are approved for use with abutments of KAT Implants System, and considering the fact that KAT Implants System Onepiece Implants 2.5 and predicate KAT Implants System 2.5mm implants (K083544) have identical dimensions, no further fatigue testing was deemed necessary.

    KAT Implants System Angled Abutments are implant abutment devices intended to be distributed as part of the KAT Implants System. KAT Implants System currently consists of implants, abutments, and Class I accessory instrumentation cleared for marketing under Traditional 510(k) Pre-marketing Notification # K083544 and K101201. All dental abutments of the KAT Implants System are a) used for the same indication, b) are manufactured with the same Ti-6AI-4Va ELI alloy, c) undergo the same surface treatment and sterilization, d) packaged and labeled using the same packaging materials and Instructions for Use, and e) are intended to be assembled together during surgery utilizing the same locking-taper implant post/abutment connection, with the aid of the same KAT Implants System Class 1 accessories and instruments.

    Like the predicate KAT Implants System Straight (Prepable) Abutments with outside diameters 4.2mm 4.6mm and 5.4mm (all available only in 6.5mm length), KAT Implants System Angled Abutments which are subject of this 510(k), consist of a same-dimension internal hollow bore on one end for connection with the abutment-receiving post of the KAT Implants System Dental Implants. Like the abutment predicate, they are similarly designed to be retained by the KAT Implants System Dental Implants through the abutment-receiving post. A locking-taper connection is activated with a torque wrench set at 25 Ncm.

    KAT Implants System Ball Abutments are implant abutment devices intended to be distributed as part of the KAT Implants System.

    Like the predicate KAT Implants System Straight (Prepable) Abutments with outside diameters 4.2mm, 4.6mm and 5.4mm (all available only in 6.5mm length), KAT Implants System Ball Abutments which are subject of this 510(k), consist of a same-dimension internal hollow bore on one end for connection with the abutment-receiving post of the KAT Implants System Dental Implants. Like the abutment predicate, they are similarly designed to be retained by the KAT Implants System Dental Implants through the abutment-receiving post. A locking-taper connection is activated with a tapping force – the same method used to activate locking taper connection on the other predicate - KAT Implants System Implant Abutment 4.2x6.5.

    The material of construction (Ti-6Al-4Va ELI Alloy), all surface preparation, all packaging, labeling and sterilization of KAT Implants System Angled Abutments and Ball Abutments are the same as previously cleared KAT Implants Straight and Implant Abutments. The outside diameters are the same, however, dimensional characteristics which differ from KAT Implant System Straight Abutments predicate duly noted below:

    Angled Abutments: outside diameter availability in 4.6mm, and 5.4mm (within the range of previously cleared KAT Implant System Straight Abutments outside diameters), all with an 8.5mm length at 10° and 20° angulation. Mesial-distal width of Angled Abutment 4.2 10° and Angled Abutment 4.2 20° is 4.2mm.

    Ball Abutments: outside diameter availability in 4.2mm (within the range of previously cleared KAT Implant System Straight Abutments outside diameters), and lengths between 6.5 and 8.5mm at 0°, 10° and 20° angulation.

    The dimensional properties arising from differences in length between KAT Implants System Angled and Ball Abutments and the predicate KAT Implants System Straight Abutments were investigated by fatigue testing on KAT Implants System Angled Abutment 4.2mm x 8.5mm (20 ° anqularity) samples. The testing was executed per ISO 14801:2007, Dentistry - Implants -Dynamic fatique testing on endosseous dental implants. The use of a 4.2mm width by 8.5mm length Angled Abutment with 20° angularity is considered worst-case scenario representation for KAT Implants System abutments.

    All KAT Implants System Dental Implant and Abutment devices which are subject of this 510(k) and the listed predicate devices are substantially equivalent because they are:

    Manufactured using the same Titanium-6Aluminum-4Vanadium ELI alloy (certified to meet ASTM F136. Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI Alloy for Surgical Implant Applications and biocompatibility requirements of Class II Special Control Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Implant Abutments);

    Packaged with the same size and material primary packaging (in conformance with material and process requirements of ISO 11607, Packaging for Terminally-Sterilized Medical Devices and ASTM F88, Standard Test Method for Seal Strength of Flexible Barrier Materials);

    Are sterilized using the same sterilization process and sterility assurance level with SAL = 10-6 (per ISO 11137, Sterilization of Healthcare Products - Radiation).

    Have the same Indications for Use.

    Do not present any new dimensions and operating technology from endosseous dental implants and abutments already present in the market.

    The only modifications that were made are:

    1. Angle of the predicate Straight Abutments was changed from 0° to 10° and 20°;

    2. Length of the predicate Straight Abutments was changed from 6.5mm to longer lengths. New abutment devices were named Angled Abutments 4.2 20°, 4.6 20°, 4.2 10°, 4.6 10°, 5.4 10°.

    3. Internal thread of the Straight Abutments was removed and a ball element was added. New abutment devices were named Ball Abutments 3.5, 4.5, 5.5, 3.5 10°, 4.5 10°, 4.5 20°, 4.5 20°, 4.5 20°,

    4. Abutment receiving post of the predicate KAT Implants 2.5 and 3.0 was made longer. New implant devices were named One-Piece Implants 2.5 and 3.0;

    5. Implant blasting media was changed from aluminum oxide to a soluble tricalcium phosphate. All KAT Implants System Implants will be blasted with soluble tricalcium phosphate and will retain original names.

    AI/ML Overview

    The document describes the K112758 submission for KAT Implants System components. The submission focuses on demonstrating substantial equivalence to previously cleared predicate devices through non-clinical testing.

    Here's a breakdown of the requested information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    For the fatigue testing, the acceptance criterion implicitly comes from the predicate device and the ISO standard. The document states that the samples were able to withstand a certain force over a specified number of cycles. The fatigue testing for the new devices aims to show equivalent performance to maintain safety and effectiveness.

    Acceptance Criteria (Implied)Reported Device Performance
    Withstand dynamic fatigue testing per ISO 14801:2007Samples able to withstand 440 N of force over 5 million cycles
    Demonstrate sufficient rotational stability for ball abutmentsBall Abutment Rotational Stability Test was conducted to justify the use of a tapping force to seat ball abutments.
    Biocompatibility conforming to ASTM F136Manufactured using Titanium-6Aluminum-4Vanadium ELI alloy (certified to meet ASTM F136).
    Packaging conforming to ISO 11607 and ASTM F88Packaged with the same size and material primary packaging (in conformance with material and process requirements of ISO 11607, Packaging for Terminally-Sterilized Medical Devices and ASTM F88, Standard Test Method for Seal Strength of Flexible Barrier Materials).
    Sterilization conforming to ISO 11137 with SAL = 10^-6Sterilized using the same sterilization process and sterility assurance level with SAL = 10^-6 (per ISO 11137, Sterilization of Healthcare Products - Radiation).

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Fatigue Testing: Not explicitly stated as a number, but refers to "samples" being able to withstand the force. For the "worst-case representation," a 4.2mm width by 8.5mm length Angled Abutment with 20° angularity and a 3.0mm diameter implant were tested. Without specific numbers, it is difficult to determine if statistical significance was met.
    • Data Provenance: The studies are non-clinical (mechanical testing) conducted by the manufacturer, KAT Implants LLC. There is no information regarding country of origin of data (likely US, given the submission to FDA) or if it's retrospective or prospective (typically, this type of testing is prospective for new or modified devices).

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Those Experts

    This information is not applicable to this submission type. The studies described are non-clinical (mechanical and material testing), not involving human reader studies or expert ground truth generation for diagnostic accuracy.

    4. Adjudication Method for the Test Set

    This information is not applicable as there are no human reader studies described.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was Done, What was the Effect Size of how much Human Readers Improve with AI vs without AI Assistance

    This information is not applicable as there are no human reader studies described, and the device is a physical dental implant system, not an AI-based diagnostic tool.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was Done

    This information is not applicable as the device is a physical dental implant system, not a software algorithm.

    7. The Type of Ground Truth Used

    The "ground truth" for the non-clinical tests is established by recognized engineering standards and specifications:

    • Fatigue Testing: ISO 14801:2007 (Dentistry - Implants - Dynamic fatigue testing on endosseous dental implants).
    • Biocompatibility: ASTM F136 (Standard Specification for Wrought Titanium-6Aluminum-4Vanadium ELI Alloy for Surgical Implant Applications) and biocompatibility requirements of the Class II Special Control Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Implant Abutments.
    • Packaging: ISO 11607 (Packaging for Terminally-Sterilized Medical Devices) and ASTM F88 (Standard Test Method for Seal Strength of Flexible Barrier Materials).
    • Sterilization: ISO 11137 (Sterilization of Healthcare Products - Radiation).

    8. The Sample Size for the Training Set

    This information is not applicable as the device is a physical product and not an AI/ML algorithm that requires a training set.

    9. How the Ground Truth for the Training Set was Established

    This information is not applicable as the device is a physical product and not an AI/ML algorithm that requires a training set.

    Ask a Question

    Ask a specific question about this device

    K Number
    K101201

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2011-04-13

    (349 days)

    Product Code
    Regulation Number
    872.3640
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    KAT Implant System Dental Implants are indicated for restoration of edentulous maxilla and mandible, to provide support for removable dentures, fixed bridges, or to be used as a single tooth replacement. Single or splinted implants can be immediately loaded if good primary stability and appropriate occlusal loading are achieved. The implants can be placed in extraction sites or healed alveolar ridges. Immediate loading may not be appropriate in Type IV bone due to difficulty in achieving primary stability.

    KAT Implant System Straight Abutment devices are intended to be used with KAT Implant System Dental Implants to aid in prosthetic rehabilitation.

    KAT Implant System (Dental Implants and Straight Abutment) is indicated for the restoration of edentulous areas in maxilla and mandible.

    Device Description

    KAT Implant System Dental Implants (with outside diameters 6.0mm, 7.0mm and 8.0mm) and KAT Implant System Straight (Prepable) Abutments (with outside diameters 4.2mm, 4.6mm, 5.0mm, 5.4mm, and 6.4mm) are root-form, endosseous dental implant and implant abutment devices intended to be distributed as part of the KAT Implant System platform. KAT Implant System currently consists of implants, abutments, and Class I accessory instrumentation cleared for marketing under Traditional 510(k) Prc-marketing Notification # K083544.

    Like the predicate KAT Implant System Dental Implant with outside diameter 5.0mm, the KAT Implant System Dental Implants which are subject of this 510(k) are provided in lengths of 6.0mm, 8.0mm, and 10.0mm. External V-shaped thread is similarly utilized in these new sizes of KA I Implant System Dental Implants in order to screw the implants into the bone. Horizontal fins are also placed between the thread and the abutment receiving portion of these dental implants. The abutment receiving portion of all KAT Implant System Dental Implants consists of a 3.1mm outside diameter post with a 1.5 degree taper. All KAT Implant System Dental Implants are intended to be used with previously cleared KAT Implants System Implant Abutments, as stated in Instructions for Use.

    Like the predicate KAT Implant System Implant (Indexed) Abutments with outside diameters 4.2mm, 4.7mm, 5.5mm and 6.5mm, the KAT Implant Straight (Prepable) Abutments which are subject of this 510(k) consist of outside diameters within the predicate's range of outside diameters, and are 6.5mm in length. KAT Implant System Straight (Prepable) Abutments are similarly retained by the KAT Implant System Dental Implants through the abutmentreceiving post. A locking-taper connection activates the seating of the abutment to the implant with the help of a torque wrench.

    AI/ML Overview

    This document is a 510(k) summary for a dental implant system. It focuses on demonstrating substantial equivalence to a predicate device rather than presenting a standalone clinical study with acceptance criteria and performance data in the traditional sense of an AI/ML device submission.

    As such, the information requested in your prompt regarding acceptance criteria, study design, expert involvement, and ground truth is largely not applicable or not explicitly detailed in this type of submission for a physical medical device like a dental implant.

    However, I can extract the relevant information and approximate answers where possible based on the provided text, primarily focusing on the comparison to the predicate device.

    Here's the breakdown of the information you requested:


    1. A table of acceptance criteria and the reported device performance

    The document doesn't explicitly state "acceptance criteria" in the format of specific quantitative benchmarks. Instead, it demonstrates substantial equivalence based on a comparison of technological characteristics and performance testing to a legally marketed predicate device. The "performance" here refers to the outcomes of bench testing designed to show comparable safety and efficacy to the predicate.

    Acceptance Criteria (Implied from Substantial Equivalence)Reported Device Performance (as demonstrated by comparison/testing)
    Materials: Same as predicate (Titanium-6Aluminum-4Vanadium ELI alloy per ASTM F136-2(a), biocompatibility per Class II Special Control Guidance Document).The subject devices are manufactured using the same Titanium-6Aluminum-4Vanadium ELI alloy, certified to meet ASTM F136-2(a) and biocompatibility requirements of the Class II Special Control Guidance Document.
    Surface Treatment: Same as predicate (aluminum oxide grit-blasting, alkaline ultrasonication, nitric acid passivation per ASTM F86-04).The subject devices undergo the same aluminum oxide grit-blasting (compliant with Class II Special Control Guidance Document) and same surface preparation processes (alkaline ultrasonication and nitric acid passivation per ASTM F86-04).
    Packaging: Same as predicate (material and process requirements of ISO 11607:2006).The subject devices are packaged with the same size and material primary packaging, conforming to ISO 11607:2006.
    Sterilization: Same as predicate (radiation sterilization per ISO 11137:2006 with SAL = 10^-6).The subject devices are sterilized using the same sterilization process and sterility assurance level (SAL = 10^-6) per ISO 11137:2006.
    Implant/Abutment Rotation/Loosening Performance: Comparable to predicate.Predicate: Insertion of abutment with force not less than 15 N-cm (torque wrench) or tapping force. Rotation/loosening prevented by frictional fit and engagement between implant post grooves and key's protrusions. Subject Device (Implant): Same results as predicate (characterization performed as implant/abutment system). Subject Device (Abutment): Insertion with force not less than 25 N-cm (torque wrench) or tapping force. Demonstrated better resistance to rotation/loosening compared to predicate device. Justification for 25 N-cm torque provided in Section 18, Performance Testing.
    Implant/Abutment Fatigue Performance: Meets guidance for fatigue testing per Class II Special Control Guidance Document, comparable to predicate.Predicate: Meets guidance for Fatigue testing per Class II Special Control Guidance Document (tested on 3.5mm diameter implant). Has substantial equivalence with the predicate in terms of fatigue performance, if not better. Subject Device (Implant): Same results as predicate (characterization performed as implant/abutment system). Subject Device (Abutment): Same results as subject device implant (characterization performed as implant/abutment system).

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    This document describes bench testing (non-clinical) rather than a clinical study.

    • Sample Size: Not explicitly stated in terms of the number of units tested for each specific performance characteristic (e.g., how many abutments were tested for rotation/loosening, or how many implant-abutment systems were tested for fatigue). The document refers to "Testing performed on Implant/Abutment System as presented in Section 18, Performance Testing – Bench." Section 18 is not provided in this excerpt, but it would typically contain the specific number of test articles.
    • Data Provenance: Bench test data originating from the manufacturer (KAT Implants LLC, Portsmouth, NH 03801, USA). This is non-clinical data, not patient data, so "country of origin of the data" and "retrospective or prospective" are not applicable in the patient data sense.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    This is a physical medical device 510(k) submission, not an AI/ML device. Therefore, the concept of "experts establishing ground truth for a test set" in the context of diagnostic interpretation is not applicable. The "ground truth" for this device's performance is established by engineering and materials science testing standards (e.g., ASTM, ISO standards, and FDA guidance documents like the Class II Special Control Guidance Document for Root-form Endosseous Dental Implants). These standards define how to objectively measure properties like material composition, strength, fatigue resistance, and sterilization effectiveness.


    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable for this type of physical device submission. Adjudication methods like 2+1 or 3+1 are typically used in clinical studies where human experts are interpreting data (e.g., images) to establish "ground truth" or resolve disagreements. Here, the "truth" is determined by objective physical measurements according to established engineering protocols.


    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. MRMC studies are specific to diagnostic devices (often AI-powered) where human readers (e.g., radiologists) interpret cases, and the study evaluates the impact of an AI tool on their performance. This document is for a physical dental implant system.


    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    Not applicable. This is not an algorithm or AI device.


    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" for this device is based on:

    • Compliance with material specifications (e.g., ASTM F136-2(a) for alloy, ASTM F86-04 for surface preparation).
    • Compliance with packaging and sterilization standards (ISO 11607:2006, ISO 11137:2006).
    • Results from mechanical bench testing (e.g., for rotation/loosening, fatigue) against benchmarks implied or referenced by the FDA's "Class II Special Control Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Implant Abutments," and comparison to the predicate device's established performance.

    8. The sample size for the training set

    Not applicable. This is not an AI/ML device that requires a "training set."


    9. How the ground truth for the training set was established

    Not applicable. This is not an AI/ML device that requires a "training set."

    Ask a Question

    Ask a specific question about this device

    K Number
    K083544

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2009-02-02

    (66 days)

    Product Code
    Regulation Number
    872.3630
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    KAT Implant System is intended to restore edentulous areas of maxilla and mandible, to provide support for removable dentures, fixed bridges, or to be used as a single tooth replacement. Single or splinted implants can be immediately loaded if good primary stability and appropriate occlusal loading are achieved. The implants can be placed in extraction sites or healed alveolar ridges. Immediate loading may not be appropriate in Type IV bone due to difficulty in achieving primary stability.

    KAT 3.0mm implant is indicated for use in maxillary lateral or mandibular lateral and central incisors in single or multiple units to support prosthesis, such as artifical teeth. The implant can be placed in extraction sites or healed alveolar ridges and can be immediately loaded when good primary stability is achieved and the functional load is appropriate. Immediate loading may not be appropriate in Type IV bone due to difficulty in achieving primary stability.

    KAT 2.5mm is a self-tapping titanium alloy threaded screw indicated for transitional and long-term intra-bony applications, such as providing support for transitional and crowns, bridges and dentures. KAT 2.5mm may also be used for inter-rollul br transitional application.

    Device Description

    KAT implant system consists of dental implants, implant abutments, healing abutments, temporary abutments, screw retained framework abutment, spacer, cylinder, healing collar and the instruments for placement and restoration of the implants. KAT implants are supplied in 2.5, 3.0, 3.5, 4.3 and 5.0mm diameters. KAT 2.5 and 3.0mm implants are supplied in 10, 12 and 14mm length. IAAT 3.5mm is supplied in 8, 10, 12 and 14mm length. KAT 4.3 and 5.0mm inplants are supplied in 6, 8, 10, 12 and 14mm length. External V-shaped thread is utilized to screw the implants into the bone. Horizontal fins are placed in between the thread and the abutment receiving portion of 3.5, 4.3 and 5.0mm implace All implants have 3.1mm diameter 1.5 degree taper abutment receiving post. KAT abutments are available in 4.2, 4.7, 5.5 and 6.5mm diameter. KAT abutments can be attached to any KAT implant via locking taper connection.

    AI/ML Overview

    The KAT Implant System was found substantially equivalent to predicate devices based on similarities in intended use, operating principles, basic design, materials, and sterilization processes. No specific acceptance criteria with quantifiable metrics were provided in the document. The study described is a submission for substantial equivalence to legally marketed predicate devices, not a study evaluating specific performance metrics against pre-defined acceptance criteria.

    Here's an analysis of the provided text based on your request:

    1. Table of Acceptance Criteria and Reported Device Performance

    The provided document does not contain a table of explicit acceptance criteria with quantifiable performance metrics. The FDA clearance is based on a determination of substantial equivalence to predicate devices. This means the device is considered as safe and effective as a legally marketed device and doesn't introduce new questions of safety or effectiveness.

    The document states:

    • "KAT Dental Implant System has the same intended use as, and technological characteristics similar to the legally marketed predicate devices. Any differences in the technological characteristics did not raise new issues of safety and effectiveness."

    Therefore, the "reported device performance" is essentially that the device is, by virtue of substantial equivalence, expected to perform similarly to the predicate devices.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not describe a "test set" in the context of performance evaluation with a specific sample size. The submission is focused on demonstrating substantial equivalence to existing devices through comparison of design, materials, and intended use, rather than presenting results from a performance study using a test set of implants in patients or a cadaver study.

    Therefore, no information on sample size or data provenance (country of origin, retrospective/prospective) for a test set is available.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    Since no performance study with a "test set" is described, there is no mention of experts used to establish ground truth or their qualifications.

    4. Adjudication Method for the Test Set

    As no performance study with a "test set" is described, there is no information on adjudication methods.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    No MRMC comparative effectiveness study was described or performed in this submission. The submission relies on demonstrating substantial equivalence to predicate devices, not on showing efficacy through direct comparison of human readers with or without AI assistance.

    6. If a Standalone Performance Study Was Done

    No standalone performance study (i.e., algorithm only without human-in-the-loop performance) was described. The device is a physical dental implant system, not a software algorithm.

    7. The Type of Ground Truth Used

    The "ground truth" for the substantial equivalence determination is the established safety and effectiveness of the legally marketed predicate devices. The new device is compared against these existing devices.

    The predicate devices mentioned are:

    • LaminOss® Osteocompressive Dental System (K982925)
    • Bicon Dental Implant 4.5 x 6.5mm (K050712)
    • IMTEC Sedax MDI 1.8mm (K031106)
    • OsseoSpeed 4.0S-6mm (K063779)
    • OsseoSpeed Narrow (K080396)

    8. The Sample Size for the Training Set

    Since this is a submission for a physical medical device (dental implants) and not a machine learning algorithm, the concept of a "training set" is not applicable and therefore no sample size is provided.

    9. How the Ground Truth for the Training Set Was Established

    As noted above, the concept of a "training set" is not applicable here.