510(k) Data Aggregation

    K Number
    K253429

    Validate with FDA (Live)

    Date Cleared
    2026-03-12

    (162 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    18 - 150
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Genadyne Astra NPWT System is indicated for use in patients who would benefit from negative pressure wound therapy particularly as the device can be used for wound management by the removal of excess exudates, infectious material and tissue debris.

    Appropriate wound type include:

    • Chronic
    • Acute
    • Traumatic
    • Subacute and dehisced wounds
    • Partial thickness burns
    • Ulcers (such as diabetic or pressure)
    • Flaps and grafts

    For use by healthcare professional and home use. This NPWT System can only be used with approved dressing kits under K233614.

    Device Description

    The Genadyne ASTRA NPWT is a Negative Pressure Wound Therapy. The ASTRA NPWT features an interface touch panel which provides user selectable therapy modes (continuous mode and variable mode) and multi pressure options from 40mmHg to 200 mmHg). The ASTRA NPWT is packaged in a box that includes a universal charger, power cable, a user manual and a user carry bag. The dressing kits (approved under K233614) includes the transparent film dressings, the Genadyne foam dressing and the Genadyne Port. The Genadyne ASTRA NPWT is designed to be used with a canister collection system. The canister will have 3 sizes available (200cc, 400cc and 600cc).

    All the dressings and canisters are single use disposable items. To help ensure safe and effective use, the ASTRA NPWT are to be used only with the Genadyne supplied dressings (approved under K233614) and canisters. For our bench test, the ASTRA NPWT was tested with the Genadyne green thick foam dressing kit.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K243225

    Validate with FDA (Live)

    Date Cleared
    2024-12-31

    (84 days)

    Product Code
    Regulation Number
    868.5905
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Nasal Pillow Mask is intended for patients (> 30 kg) who have been prescribed CPAP/VPAP therapy in home, hospital, or institutional environments. This device is intended to be use under the direction of a physician.

    Device Description

    The Nasal Pillow Mask is patient interface device intended for use with CPAP/VPAP therapy systems. The device provides non-invasive means of delivering positive airway pressure to the user by creating a sealed interface using nasal pillows that fit directly into the patients' nostrils. The Nasal Pillow Mask is made of silicone material and comes in 3 different sizes (S, M & L). The nasal mask comes with standard hose fitting intended to be used with standard CPAP/VPAP system. It is intended to be use on patients (> 30 kg) who have been prescribed CPAP/VPAP therapy at home, hospital, or institutional environments. The complete mask set incudes headgear, frame, tube, and nasal pillows (S, M, & L sizes).

    AI/ML Overview

    This document is a 510(k) summary for a Nasal Pillow Mask, indicating that the device is substantially equivalent to a previously cleared predicate device. As such, it highlights the lack of a new study to demonstrate acceptance criteria because the device is deemed identical to its predicate in all relevant aspects.

    Here's the breakdown of why the requested information cannot be fully provided based solely on the input, and what can be extracted:

    1. A table of acceptance criteria and the reported device performance

    The document explicitly states: "The subject device is identical to predicate device except for manufacturer name, brand name, and resulting labeling updates. The indications for use, design, principles of operation, and materials are all identical to the predicate device already cleared by FDA. Therefore, no new non-clinical testing is required."

    This means that for the current 510(k) submission (K243225), no new acceptance criteria or reported device performance data was generated or provided for the subject device. The acceptance criteria and performance data would have been established and demonstrated for the predicate device (K120920) in its original submission.

    The table in the document provides specifications for Deadspace Volume, Resistance, Therapy pressure, Noise level, Environmental Conditions, Weight, and Size Flow, which are common technical specifications for such devices. These are not explicitly stated as "acceptance criteria" but rather as "Specifications" that are "Same" as the predicate.

    Specification ItemSubject Device Performance (Reported as "Same" as Predicate)
    Deadspace VolumeS size: 90.8M size: 94.3L size: 95
    Resistance 50 L/m(Value not numerically given, stated as "Same")
    Resistance 100 L/mS size: 6.87M size: 5.93L size: 5.3
    Therapy pressure5~20cmH2O (Reported as 10cmH2O)
    Noise levelS size: 35.036.0M size: 34.235.6L size: 35.4~36.8
    Environmental ConditionsStorage and Transportation: 15°C ~ 25°C, up to 95% non-condensing Storage relative humidity: <85%
    Weight69.9g
    Size Flow (l/min) @ 5 cmH2OS: 24.94, M: 24.85, L: 25.28
    Size Flow (l/min) @ 10 cmH2OS: 35.66, M: 35.61, L: 35.79
    Size Flow (l/min) @ 15 cmH2OS: 44.76, M: 45.07, L: 44.71
    Size Flow (l/min) @ 20 cmH2OS: 52.46, M: 52.21, L: 51.99

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • No new sample size or test set was used for the subject device as "no new non-clinical testing is required." Testing relevant to these specifications would have been performed for the predicate device.
    • Data provenance: Not applicable for the subject device's 510(k) as no new studies were conducted. The origin of the predicate device's data is not provided in this document.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable. No expert ground truth establishment was conducted for the subject device's 510(k), as it leveraged the equivalence to a predicate device.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable. No new test set or expert adjudication was performed for the subject device.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No. This device is a physical medical device (nasal pillow mask), not an AI-powered diagnostic or assistive technology. Therefore, an MRMC study or assessment of AI assistance is irrelevant and was not performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • No. This device is a physical medical device and does not involve an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Not applicable for the subject device's 510(k). The substantial equivalence determination is based on the device being identical to the predicate in design, materials, and intended use, not on new clinical performance data or ground truth establishment for the subject device. The specifications listed are objective physical measurements.

    8. The sample size for the training set

    • Not applicable. This is a physical medical device, not an AI/machine learning model that requires a training set.

    9. How the ground truth for the training set was established

    • Not applicable. As above, no training set was used.

    In summary of the provided document:

    The 510(k) submission for the Nasal Pillow Mask (K243225) is based on the premise of substantial equivalence to a predicate device (Hsiner Nasal Pillow Mask, K120920). The manufacturer asserts that the subject device is identical to the predicate device in terms of indications for use, design, principles of operation, and materials. Therefore, no new performance studies, acceptance criteria demonstration, or clinical data were generated for the subject device. The FDA's clearance is based on the established safety and effectiveness of the predicate device, which the subject device is claimed to replicate.

    Ask a Question

    Ask a specific question about this device

    K Number
    K233614

    Validate with FDA (Live)

    Date Cleared
    2024-12-23

    (406 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Genadyne DUO Negative Pressure Wound Therapy System is an integrated wound management system that provides Negative Pressure Wound Therapy with an instillation option.

    · The Genadyne DUO NPWT System, in the absence of instillation is intended to create an environment that promotes wound healing by secondary or tertiary (delayed primary) intention by preparing the wound bed for closure, reducing edema, promoting granulation tissue formation and perfusion, and by removing exudate and infectious material. • Instillation therapy is indicated for patients who would benefit from vacuum assisted drainery of topical wound treatment solutions and suspensions over the wound bed.

    The Genadyne DUO Negative Pressure Wound Therapy System with and without instillation is indicated for patients with chronic, acute, traumatic, sub acute and dehisced wounds, partial- thickness burns, ulcers (such as diabetic, pressure and venous insufficiency), flaps and grafts.

    Device Description

    The Genadyne DUO NPWT is a Negative Pressure Wound Therapy unit with instillation option. The DUO NPWT features an interface touch panel which provides user selectable therapy modes (continuous mode and variable mode) and multi pressure options from 40 m m H g to 200 mmHg). The DUO NPWT is packaged in a box that includes a universal charger, power cable, a user manual and a user carry bag. The dressing kits includes the transparent film dressings, the Genadyne foam dressing and the Genadyne Port. The DUO NPWT is designed to be used with a canister collection system. The canister will have 3 sizes available (600cc, 800cc and 1100cc). All the dressings and canisters are single use disposable items. To help ensure safe and effective use, the DUO NPWT are to be used only with the Genadyne supplied dressings and canisters. There is an instillation option on the device for instillation therapy for the patient that requires it. The installation option provides a controlled delivery of topical wound treatment solutions and suspensions over the wound bed. The instill mode consists of NPWT combined with the automatic, controlled delivery and removal of wound treatment solutions to and from the wound bed. It offers a more conducive dressing environment for wound bed management with adjustable target pressure, vacuum time, instill volume, and soaking time. With the adjustable target pressure, negative pressure in mmHg is applied to the wound.

    AI/ML Overview

    I am sorry, but the provided text does not contain the information required to answer your request. The document is an FDA 510(k) clearance letter for a medical device (Genadyne DUO NPWT), but it does not include details about acceptance criteria, specific study results proving device performance against those criteria, sample sizes for test or training sets, ground truth establishment, expert qualifications, or MRMC studies.

    The document primarily focuses on:

    • Device Description and Indications for Use: What the device is and what it's used for.
    • Substantial Equivalence: How the device is similar to a legally marketed predicate device.
    • Regulatory Compliance: Information about general controls, quality system regulations, UDI, and adverse event reporting.
    • Non-clinical Testing: Mentions that bench tests were performed per ISO10079-1 to show the device functions appropriately, including "Pressure precision test, absorption test, alert capacity test, instill therapy test." It also mentions software documentation and a "Moderate" level of concern for software.

    It does not provide the quantitative results or the methodology of these tests in detail, nor does it define acceptance criteria for these tests or relate them to clinical performance metrics. The information needed for a detailed description of acceptance criteria and the study proving performance (as outlined in your request) is simply not present in the provided text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K221888

    Validate with FDA (Live)

    Date Cleared
    2023-06-12

    (348 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Genadyne Hybrid Foam Dressings when used in conjunction with the XLR8+, UNO30 and UNO Plus NPWT System is indicated to help promote wound healing, through means including drainage and removal of infectious material or other fluids, under the influence of continuous and/or intermittent negative pressures, particularly for patients with chronic, acute, traumatic, subacute and dehisced wounds, partial thickness burns, ulcers (such as diabetic or pressure), flaps and grafts.

    Device Description

    The Genadyne Hybrid foam dressings are designed to be used with the Genadyne XLR8+ NPWT (K143726), UNO30 (K190028) and UNO Plus (K210107). The dressing has a layer of silicone that will be placed as a contact layer to the patients wound. All the dressings are single use disposable items. To help ensure safe and effective use, the Genadyne Hybrid foam dressings are to be used only with the Genadyne supplied devices. The decision to use clean versus sterile/aseptic technique for wound cleaning is dependent upon wound pathophysiology, physician/clinician preference, and institutional protocol.

    AI/ML Overview

    This document is an FDA 510(k) clearance letter for a medical device called "Genadyne Hybrid Foam Dressings." It does not contain any information about an AI/ML device or a study proving its performance against acceptance criteria.

    The information provided describes a dressing used in Negative Pressure Wound Therapy (NPWT) and compares it to a predicate device. The review focuses on the device's technological characteristics and intended use, asserting substantial equivalence based on bench testing of the dressings' function with existing NPWT systems.

    Therefore, I cannot fulfill your request to describe acceptance criteria and a study proving device performance for an AI/ML device, as the provided text doesn't concern such a device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K221891

    Validate with FDA (Live)

    Date Cleared
    2022-12-14

    (168 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Genadyne UNO Negative Pressure Wound Therapy System is in patients who would benefit from negative pressure wound therapy particularly as the device may promote wound healing by the removal of low to moderate exudates and infectious material. Appropriate wound types include:

    • Chronic
    • Acute
    • Traumatic
    • Subacute and dehisced wounds
    • Ulcers (such as diabetic or pressure)
    • Flaps and grafts
    • Closed Surgical Incision
      Genadyne UNO Negative Pressure Wound Therapy System is a single patient use device.
    Device Description

    The Genadyne UNO Negative Pressure Wound Therapy System is a single patient use Negative Pressure Wound Therapy (NPWT) Unit designed for moderate to low severity wounds. The Genadyne UNO Negative Pressure Wound Therapy System has a pre-determined lifespan. The unit has an interface panel which provides alert and information signals and selectable therapy options. This unit provides negative pressure at either 80 mmHg or 125 mmHg, and has selections of Continuous Mode at 80mmHg/ 30mmHg or 125mmHg / 30mmHg in Variable Mode. The Genadyne UNO Negative Pressure Wound Therapy System Therapy Kits include a therapy unit. 200 ml and 300 mL canisters, and sterile dressing kits. Dressing kits and canisters for the Genadyne UNO Negative Pressure Wound Therapy System can be provided separately. The dressing is intended to be used for a maximum of 3 days. Therapy duration of the dressing may be less than indicated if clinical practice or other factors such as wound type, wound size, rate or volume of exudate, orientation of the dressing or environmental conditions, result in more frequent dressing changes. Disposable components of the Genadyne UNO Negative Pressure Wound Therapy System, including the foam dressing and drape, are packaged sterile (Ethylene Oxide) and not made with natural rubber latex. All disposable components of the Genadyne UNO Negative Pressure Wound Therapy System are for single use only. The Genadyne UNO Negative Pressure Wound Therapy System dressings are to be used only with the Genadyne UNO Negative Pressure Wound Therapy System.

    AI/ML Overview

    This document is a 510(k) Summary for the Genadyne UNO Negative Pressure Wound Therapy System, seeking FDA clearance for a modified version of an existing device (K190028). The submission focuses on demonstrating substantial equivalence to the predicate device, primarily through non-clinical testing.

    Here's an analysis of the provided information regarding acceptance criteria and the study that proves the device meets those criteria:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document does not explicitly present a table of acceptance criteria with detailed performance metrics. Instead, it relies on demonstrating compliance with recognized electrical safety and electromagnetic compatibility standards, and on a comparison of technical specifications with a legally marketed predicate device.

    However, based on the non-clinical testing mentioned and the comparison table, we can infer the acceptance criteria are met by demonstrating conformity to relevant standards and maintaining equivalent performance to the predicate device for critical specifications.

    Feature/SpecificationAcceptance Criteria (Implied by Predicate & Standards)Reported Device Performance (Subject Device)
    Electrical SafetyCompliance with IEC 60601-1Passed IEC 60601-1 reports submitted
    Electromagnetic Compatibility (EMC)Compliance with IEC 60601-1-2Passed IEC 60601-1-2 reports submitted
    Max Vacuum125 mmHg (matching predicate)125 mmHg (matches predicate)
    Battery TypeRechargeable Lithium Ion Battery (modified from predicate)Lithium Ion Battery (new, tested for safety)
    ChargerPresence of charger (new feature)Yes, Input: 100VAC-240VAC, 50-60Hz; Output: 5V DC, 2A, 10W
    Power Battery3.6V, 1700mAh (modified from predicate)3.6V, 1700mAh (new)
    DimensionsPhysically compatible with intended use (modified from predicate)4 3/8" x 3" x 1 5/8" (modified)
    Accessories (Canisters/Dressings)Identical to predicateIdentical to predicate (70ml, 10cm x 10cm, etc.)
    ReusabilityNon-reusable (identical to predicate)No (matches predicate)
    SterilityDressings provided sterile (identical to predicate)Dressings are provided Sterile (matches predicate)
    Indications for UseIdentical to predicateIdentical to predicate
    ContraindicationsIdentical to predicateIdentical to predicate
    Storage/Transport Temperature-18°C to +43°C (0°F to 109.4°F) (identical to predicate)-18°C to +43°C (0°F to 109.4°F) (matches predicate)
    Storage/Transport Relative Humidity15% to 95 % (identical to predicate)15% to 95 % (matches predicate)
    Storage/Transport Atmospheric Pressure700 - 1060 mbar (identical to predicate)700 - 1060 mbar (matches predicate)
    Operation Temperature18°C to 34°C (65°F to 93.2°F) (identical to predicate)18°C to 34°C (65°F to 93.2°F) (matches predicate)
    Operation Relative Humidity10% to 95 % (identical to predicate)10% to 95 % (matches predicate)
    Operation Atmospheric Pressure700 - 1060 mbar (identical to predicate)700 - 1060 mbar (matches predicate)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    • Sample Size for Test Set: The document does not specify a "test set" in terms of patient data or a specific number of devices tested for performance. The testing involved compliance with IEC standards for electrical safety and EMC. These standards typically involve a defined set of tests on representative units of the device rather than a "sample size" in the statistical sense for clinical studies. The number of devices used for these engineering tests is not disclosed.
    • Data Provenance: The document does not specify the country of origin for the non-clinical test data. The tests are described as "non-clinical" and implicitly prospective as they were performed on the new device model to demonstrate compliance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    This information is not applicable as the submission relies solely on non-clinical testing (electrical safety, EMC) and comparison to a predicate device's specifications. There was no "ground truth" derived from expert consensus on medical images or clinical outcomes for this submission.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    This information is not applicable as there was no clinical study with a test set requiring adjudication of findings. The assessment was based on engineering test results against established compliance standards.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    This information is not applicable. No MRMC comparative effectiveness study was performed as this is a Negative Pressure Wound Therapy System, not an AI-powered diagnostic imaging device. The changes relate to the pump's power source and housing, not its interaction with clinical interpretation.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    This information is not applicable. This device is a Negative Pressure Wound Therapy System, which is a physical medical device, not an algorithm or software. No standalone algorithm performance was evaluated.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    The concept of "ground truth" as typically understood in the context of diagnostic AI or clinical studies (e.g., pathology, expert consensus) is not applicable to this submission. The "ground truth" for the non-clinical tests would be the established requirements and limits defined by the IEC 60601-1 and IEC 60601-1-2 standards. The device's performance (e.g., maintaining 125 mmHg vacuum) is directly measured and compared against its own specifications and the predicate device's specifications.

    8. The sample size for the training set:

    This information is not applicable. This device is a physical medical device. It does not use machine learning or AI, and therefore does not have a "training set."

    9. How the ground truth for the training set was established:

    This information is not applicable for the reasons stated in point 8.

    Ask a Question

    Ask a specific question about this device

    K Number
    K210107

    Validate with FDA (Live)

    Date Cleared
    2022-06-01

    (502 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K190028

    Validate with FDA (Live)

    Device Name
    UNO 30
    Date Cleared
    2020-01-15

    (373 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    UNO 30 is indicated for use in patients who would benefit from negative pressure wound therapy particularly as the device may promote wound healing by the removal of low to moderate exudates and infectious material. Appropriate wound types include: Chronic, Acute, Traumatic, Subacute and dehisced wounds, Ulcers (such as diabetic or pressure), Flaps and grafts, Closed surgical incision. UNO 30 is a single patient use device.

    Device Description

    The UNO 30 is portable, battery powered wound suction pump with the intention to deliver negative pressure wound therapy to the wound. The unit provides negative pressure at either 80mmHg or 125mmHg in continuous mode and 80mmHg/30mmHg or 125mmHg/30mmHg in variable mode. The UNO 30 NPWT system includes dressing and canister.

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study for the UNO 30 device:

    The provided text is a 510(k) Premarket Notification for the UNO 30, a Negative Pressure Wound Therapy (NPWT) system. It focuses on demonstrating substantial equivalence to predicate devices, rather than a novel claim requiring extensive clinical trials or an AI's performance evaluation. Therefore, the information you're asking for, particularly concerning AI performance metrics, clinical study design, and expert adjudication, is not present in this document. The device is a physical medical device (pump, dressings, canister), not an AI-powered diagnostic or assistive tool.

    However, I can extract the relevant information available for the device as described.


    Acceptance Criteria and Device Performance (Based on "Technological Characteristics" and "Discussion of nonclinical and clinical testing" sections)

    This document doesn't present "acceptance criteria" in the typical sense of performance thresholds for an AI or diagnostic device. Instead, it focuses on demonstrating that the UNO 30 maintains similar technical characteristics and safety/effectiveness as its predicate devices, primarily the Genadyne UNO (K180840) with an extended use-life.

    The key "performance" aspect evaluated here is the extended device lifespan to 30 days while maintaining the functionality of the predicate.

    1. A table of acceptance criteria and the reported device performance

    CharacteristicAcceptance Criteria (Implied by Predicate & Device Purpose)Reported Device Performance (UNO 30)
    Max VacuumComparable to predicate (125 mmHg or 144 mmHg)125 mmHg
    Battery TypeAlkaline-Manganese Dioxide AA (QU1500)Alkaline-Manganese Dioxide AA (QU1500)
    Power (Battery)3V DC3V DC
    Dimensions / Weight3" x 4.4" x 2.4" / 400g3" x 4.4" x 2.4" / 400g
    Device LifespanExtended from 7 days (primary predicate) to 30 days (secondary predicate)30 days (Bench tests confirmed functionality for 30 days and unit shutdown after 30 days)
    Software Level of ConcernModerate (per FDA guidance)Moderate (appropriate documentation included)
    Pressure PrecisionFunctional during 30-day use-lifeBench tested and verified as functioning appropriately during the course of 30 days.
    Battery LifeFunctional during 30-day use-lifeBench tested and verified as functioning appropriately during the course of 30 days. Unit does not turn on even with new batteries after 30 days.
    AbsorbanceFunctional during 30-day use-lifeBench tested and verified as functioning appropriately during the course of 30 days.
    Alert FunctionalityFunctional during 30-day use-lifeBench tested and verified as functioning appropriately during the course of 30 days.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This document describes bench testing, not a clinical study involving patients or data sets. Therefore, there's no "sample size for the test set" in the context of patient data, nor a country of origin for such data. The tests were performed on the device itself.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    Not applicable. This device is a physical pump, not an AI or diagnostic tool requiring ground truth established by experts for performance evaluation. The "ground truth" here is the expected physical performance of the device (e.g., maintaining pressure, battery life, proper shutdown).

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    Not applicable. As this is bench testing of a physical device, there's no expert adjudication involved in the sense of reviewing outputs or diagnoses.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This document is about a physical NPWT device, not an AI or diagnostic tool. No MRMC study was performed, and thus no effect size related to AI assistance is provided.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is not an algorithm or AI. The software component mentioned is for device control and functionality, not for standalone diagnostic or assistive performance.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" for the bench tests was the engineering specifications and expected functional performance of the device (e.g., a pressure reading close to 125 mmHg, battery lasting for a certain duration, a specific alert triggering correctly). This is based on established engineering principles and the device's design requirements.

    8. The sample size for the training set

    Not applicable. There is no AI or machine learning model that requires a "training set" described in this document.

    9. How the ground truth for the training set was established

    Not applicable, as there is no training set for an AI model.

    Ask a Question

    Ask a specific question about this device

    K Number
    K182722

    Validate with FDA (Live)

    Date Cleared
    2019-09-27

    (364 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    XLR8 Abdominal Wound Dressing Kit is indicated for use in conjunction with Genadyne NPWT System's XLR8+ for patients who have open abdominal wounds with exposed viscera and organs, including but not limited to patients with abdominal compartment syndrome. XLR8 Abdominal Wound dressing Foam is used for temporary bridging of abdominal wall openings where primary closure is not possible and/or repeat abdominal entries may be required. It is intended for use in acute hospital setting(trauma, general and plastic surgery wards) and should ideally be applied in the operating theatre.

    Device Description

    XLR8 Abdominal Wound dressing is a negative pressure wound therapy device intended to provide negative pressure to the wound bed and transport exudates from the wound. Abdominal Foam is a fully reticulated hydrophobic polyurethane foam made with polyether resin.

    XLR8 Abdominal Wound dressing Kit along with Genadyne XLR8+ Negative Pressure Wound therapy Pump and its accessories is a complete negative pressure system for managing open abdomens. This dressing kit is intended for use in acute hospital settings and should ideally be applied in the operating theatre.

    The dressing kit consists of one Oval Green Abdominal Foam, one Organ Contact Layer, four transparent dressing, two XLR8 port pad. Each foam is individually packaged in a medical grade Tyvek pouch (1073B Tyvek and a polyester/polyethylene laminate with a 0.375″ side and chevron seals.)

    XLR8 Abdominal Wound Dressing Foam is for prescription use only.

    AI/ML Overview

    The provided document is a 510(k) Premarket Notification from the FDA, which assesses the substantial equivalence of a new medical device to a legally marketed predicate device. This type of submission focuses on comparing the new device's features to an existing one, rather than presenting a clinical study proving its performance against specific acceptance criteria for a diagnostic AI.

    Therefore, the document does not contain the information requested about acceptance criteria, a study proving device performance against those criteria, or details related to AI/MRMC studies, ground truth establishment, or training set specifics.

    Specifically, the document includes:

    • Device Name: XLR8 Abdominal Wound Dressing Kit
    • Predicate Device: Avance Abdominal Dressing Kit (K161939)
    • Regulation Number: 21 CFR 878.4780 (Powered suction pump)
    • Device Description: It's a negative pressure wound therapy device, an abdominal dressing kit used with a negative pressure wound therapy pump. The foam material is fully reticulated hydrophobic polyurethane.
    • Indications for Use: Temporary bridging of abdominal wall openings where primary closure is not possible and/or repeat abdominal entries may be required, for patients with open abdominal wounds with exposed viscera and organs, including abdominal compartment syndrome. Intended for use in acute hospital settings and ideally applied in the operating theatre.
    • Technological Characteristics Comparison Table: This table compares various attributes of the XLR8 Abdominal Wound Dressing Kit to its predicate, such as company, device name, 510(k) number, single use/reusable, sterile, indications for use, foam material, kit components, kit component material, contraindications, packaging, and shelf life.
    • Discussion of Non-Clinical and Clinical Testing: This section briefly mentions that biocompatibility tests were performed to support limited contact exposure and bench tests were conducted on performance (pressure precision, absorbance, alert, and dimension). It states that "The results were within the acceptable limit of the criteria that were set prior the experiment." However, it does not list these specific criteria or their measured values.

    Missing Information (critical for addressing the prompt):

    The document does not provide any of the following:

    1. A table of acceptance criteria and reported device performance linked to a specific study.
    2. Sample size used for a "test set" (as it's a non-AI device, there isn't a "test set" in the context of AI model evaluation). The testing mentioned is bench testing for physical properties, not a clinical trial to prove efficacy or safety against quantitative metrics in human patients with a specific sample size.
    3. Data provenance, expert numbers, qualifications, or adjudication methods. These are relevant for AI/diagnostic studies, not for this type of device's 510(k) submission.
    4. MRMC comparative effectiveness study details.
    5. Standalone (algorithm only) performance.
    6. Type of ground truth used.
    7. Sample size or ground truth establishment for a "training set."

    In conclusion, the provided FDA 510(k) document is for a physical medical device (wound dressing kit) and does not describe the kind of performance study, acceptance criteria, or AI model evaluation metrics relevant to the prompt. The "acceptance criteria" mentioned are for internal bench tests confirming physical properties, not clinical performance or diagnostic accuracy.

    Ask a Question

    Ask a specific question about this device

    K Number
    K180840

    Validate with FDA (Live)

    Date Cleared
    2018-11-30

    (245 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Genadyne UNO is indicated for use in patients who would benefit from negative pressure wound therapy particularly as the device may promote wound healing by the removal of low to moderate exudates and infectious material. Appropriate wound types include: Chronic, Acute, Traumatic, Subacute and dehisced wounds, Partial-thickness burns, Ulcers (such as diabetic or pressure), Flaps and grafts, Closed surgical incision. Genadyne UNO is a single patient use device.

    Device Description

    The UNO Negative Pressure Wound Therapy System is portable, battery powered wound suction pump with the intention to deliver negative pressure wound therapy to the wound.

    AI/ML Overview

    This looks like a 510(k) premarket notification for a medical device. Based on the provided text, here's a breakdown of the acceptance criteria and study information for the Genadyne UNO Negative Pressure Wound Therapy System:


    1. Table of Acceptance Criteria and Reported Device Performance

    The provided document doesn't explicitly list "acceptance criteria" for performance tests in a tabular format with corresponding reported values. Instead, it states that "The results were within the acceptable limit of the criteria that were set prior the experiment." However, based on the non-clinical testing discussion, we can infer the types of performance aspects tested.

    Acceptance Criteria CategoryReported Device Performance (as stated in the document)
    Pressure Precision"Results were within the acceptable limit"
    Absorbance"Results were within the acceptable limit"
    Alert Functionality"Results were within the acceptable limit"
    Biocompatibility"The data and results show that the device is biocompatible."

    2. Sample Size Used for the Test Set and Data Provenance

    The document mentions "A clinical case series from 15 patients with closed surgical incisions were provided as supplementary performance data in support of the safety of the device."

    • Sample Size for Test Set: 15 patients
    • Data Provenance: Not explicitly stated, but clinical case series generally imply prospective or retrospective data from a clinical setting.
      • Retrospective/Prospective: Not specified, but "case series" can be either.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    This information is not provided in the document. The document refers to a "clinical case series" as "supplementary performance data," but it does not describe how the outcomes for these 15 patients were adjudicated or evaluated by experts to establish a 'ground truth' for device performance in the context of an AI/algorithm. This device is a physical pump, not an AI diagnostic tool, therefore, the concept of "ground truth" as typically applied to image analysis or diagnostic algorithms doesn't directly apply in the same way. The "ground truth" here would relate to the patient's actual wound healing and safety outcomes, which would likely have been determined by the treating clinicians.


    4. Adjudication Method for the Test Set

    Not applicable/Not provided. As noted above, this isn't an AI diagnostic device where expert adjudication of outputs would typically be required. The "clinical case series" would involve patient follow-up and clinical assessment by healthcare professionals.


    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and Effect Size

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. This type of study is relevant for diagnostic devices (especially those involving image interpretation where multiple readers evaluate cases with and without AI assistance). The Genadyne UNO is a Negative Pressure Wound Therapy System, which is a therapeutic device, not a diagnostic one.


    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Not applicable. The Genadyne UNO is a physical medical device (a powered suction pump for wound therapy), not an algorithm or AI system. Therefore, the concept of "standalone algorithm performance" does not apply.


    7. The Type of Ground Truth Used

    For the clinical case series, the "ground truth" would be the clinical outcomes observed in the 15 patients regarding wound healing, removal of exudates/infectious material, and absence of adverse events associated with the device's use. This would be based on clinical assessment and patient follow-up by healthcare professionals. For the bench tests, the ground truth would be based on objective measurements of physical parameters (pressure, absorbance, alert function) against predefined engineering specifications.


    8. The Sample Size for the Training Set

    Not applicable. As the Genadyne UNO is a physical medical device and not an AI/Machine Learning algorithm, there is no "training set." The device's performance is established through bench testing and clinical observations, not through a learning process from data.


    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for this device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K161599

    Validate with FDA (Live)

    Date Cleared
    2017-04-06

    (301 days)

    Product Code
    Regulation Number
    878.4780
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Genadyne UNO is indicated for use in patients who would benefit from negative pressure wound therapy particularly as the device may promote wound healing by the removal of low to moderate exudates and infectious material.

    Appropriate wound types include:

    • Chronic
    • Acute
    • Traumatic
    • Subacute and dehisced wounds
    • Partial-thickness burns
    • Ulcers (such as diabetic or pressure)
    • Flaps and grafts

    Genadyne UNO is a single patient use device.

    Device Description

    The UNO Wound Vacuum System is portable, battery powered wound suction pump with the intention to apply negative pressure to the wound.

    AI/ML Overview

    Here's an analysis of the provided text regarding acceptance criteria and supporting studies for the Genadyne UNO Negative Pressure Wound Therapy System:

    Note: The provided document is a 510(k) summary, which focuses on demonstrating substantial equivalence to a predicate device, rather than presenting a full clinical trial. As such, detailed human clinical study data proving the device meets acceptance criteria in the same way a new drug or novel device might is not typically included in these summaries. The "acceptance criteria" here largely refer to comparison against the predicate device's characteristics and meeting relevant safety standards.


    Acceptance Criteria and Reported Device Performance

    The core of the "acceptance criteria" for this 510(k) submission is demonstrating that the Genadyne UNO is substantially equivalent to the predicate device, the Pico Single Use Negative Pressure Wound Therapy System (K151436), and that it meets applicable safety and performance standards.

    1. Table of Acceptance Criteria and Reported Device Performance:

    Feature/CriterionAcceptance Criteria (based on predicate or standards)Reported Device Performance (Genadyne UNO)
    Intended Use/IndicationsIndications for negative pressure wound therapy, promoting healing via removal of low to moderate exudates and infectious material for specified wound types (chronic, acute, traumatic, subacute/dehisced, partial-thickness burns, ulcers, flaps/grafts)."Similar" to predicate: Indicated for negative pressure wound therapy, promoting healing via removal of low to moderate exudates and infectious material for same specified wound types. Single patient use.
    Max Vacuum100 mmHg (Predicate: Pico)125 mmHg (Higher than predicate, but within expected therapeutic range for NPWT, no new safety/effectiveness concerns indicated).
    Battery TypeLithium AA (L91) (Predicate: Pico)Alkaline-Manganese Dioxide AA (QU1500) (Different type, but likely deemed equivalent in function/safety for the application).
    Power (Battery)3V DC (Predicate: Pico)3V DC (Matches predicate)
    CanistersN/A (Predicate: Pico did not use separate canisters, assumed to be integrated into dressing)Two 70 ml disposable canisters with built-in hydrophobic shut-off filter for overflow protection (A functional difference from predicate but addresses exudate management effectively).
    ReusableNo (Predicate: Pico)No (Matches predicate)
    SterilityPump, dressing, secondary fixation strips are sterile (Predicate: Pico)Dressings provided are sterile (Implies the pump itself might not be sterile, but the critical patient-contact components are. This is a common arrangement).
    DressingsVarious sizes (10x20, 10x30, 15x15, 15x20) (Predicate: Pico)A wider range of sizes (10x20, 10x30, 10x40, 15x15, 15x20, 15x30, 20x20, 20x25, 25x25) (More options, but fundamentally similar in type/function).
    ContraindicationsSame as predicate: Necrotic tissue with Eschar, untreated osteomyelitis, malignancy (except palliation), exposed arteries/veins/organs, non-enteric/unexplored fistulas, anastomotic sites, emergency airway aspiration, pleural/mediastinal/chest tube drainage, surgical suction."Similar" to predicate, with minor phrasing differences but substantively the same list.
    BiocompatibilityMeet biocompatibility standards for patient-contact materials.Dressings (silicone foam, PU film strips) met acceptance criteria for biocompatibility testing.
    Electrical Safety/EMCIEC 60601-1 (electrical safety), IEC 60601-1-2 (EMC), UL 60601-1, Can/CSA C22.2.Pump met acceptance criteria for all applicable IEC testing (specific clauses not detailed beyond general standards).
    Bench Testing (Performance)Ensure expected performance and outcome when used as a system.Bench testing was done with in-house protocol to ensure performance and outcome.
    Storage/Transport Temps5°C to +25°C (Predicate: Pico)-18°C to +43°C (Broader range than predicate, indicating robust design for storage/transport).
    Operation Temps5°C to 35°C (Predicate: Pico)18°C to 34°C (Slightly narrower range than predicate, but within typical clinical environment).

    Study Details:

    The document primarily describes non-clinical testing to support substantial equivalence.

    2. Sample size used for the test set and the data provenance:

    • Test Set Sample Size: Not specified for individual tests. For the non-clinical testing, sample sizes would typically refer to the number of units tested per bench test (e.g., n=3, n=5, n=10 devices). The document states "Bench testing was done with in house protocol to establish ensure the performance and outcome."
    • Data Provenance: The testing appears to be prospective bench testing conducted in-house by Genadyne Biotechnologies, Inc., and potentially by third-party labs for standards compliance (e.g., biocompatibility, IEC). The country of origin for the data generation would likely be the USA, as this is a US-based company submitting to the FDA.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • This information is not provided in the document. For bench/non-clinical testing, "ground truth" is typically established by engineering specifications, recognized standards (e.g., ISO, IEC), and scientific principles, not by expert medical consensus on individual cases.

    4. Adjudication method for the test set:

    • This is not applicable to the type of non-clinical, bench testing described. Adjudication methods like 2+1 or 3+1 are used for reviewing patient cases, often in diagnostic studies to establish a consensus ground truth.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No, an MRMC comparative effectiveness study was not done. This type of study is relevant for AI-powered diagnostic devices, where human readers (e.g., radiologists) interpret images with and without AI assistance. The Genadyne UNO is a therapeutic negative pressure wound therapy system, not a diagnostic imaging device with AI interpretation.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done:

    • No, this is not applicable. The Genadyne UNO is a medical device (a powered suction pump) used directly on patients for wound therapy, not an algorithm, and does not have a "standalone" algorithmic performance. Its performance is its functional operation (e.g., maintaining negative pressure, managing exudate).

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

    • For the non-clinical testing described, the "ground truth" or reference standards used would be:
      • Engineering specifications for device function (e.g., vacuum pressure, battery life).
      • International standards (e.g., ISO 10993 for biocompatibility, IEC 60601 series for electrical safety and electromagnetic compatibility).
      • Predicate device characteristics as a benchmark for comparison.

    8. The sample size for the training set:

    • Not applicable. This device is not an AI/Machine Learning algorithm, so there is no "training set."

    9. How the ground truth for the training set was established:

    • Not applicable. As there is no training set for an AI algorithm.

    Summary of Device Meeting Acceptance Criteria:

    The document concludes that the Genadyne UNO meets its acceptance criteria by demonstrating substantial equivalence to the predicate device and by passing relevant safety and performance non-clinical tests.

    • Biocompatibility Testing: The dressing kit (silicone foam dressing, PU film strips) met accepted criteria.
    • Electrical Safety & EMC Testing: The pump successfully met acceptance criteria for all applicable IEC testing.
    • Bench Testing: In-house protocols were used to ensure the device's performance and outcome were as expected.
    • Design & Function Comparison: While some technical specifications differ (e.g., max vacuum, battery type, canister use), these differences are highlighted and determined not to raise new issues of safety or effectiveness. The fundamental intended use, indications, and contraindications are presented as similar to the predicate.

    The basis for acceptance is that the device is as safe and effective as a legally marketed predicate device, as evidenced by these non-clinical comparisons and standard compliance.