510(k) Data Aggregation

    K Number
    K172457

    Validate with FDA (Live)

    Date Cleared
    2018-06-28

    (318 days)

    Product Code
    Regulation Number
    870.2100
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CardioQ-EDM series fluid management and cardiac output monitoring systems are designed to provide clinicians with real-time information about patients left ventricular blood flow and key hemodynamic parameters. The CardioQ-EDM series beat to beat data on cardiovascular status can be used by the managing clinician to evaluate and optimize hemodynamic performance in anesthetized, sedated or conscious patients in the operating room, intensive care unit, emergency room or ward.

    The CardioQ-EDM series monitors when used in Flow Monitoring Mode (esophageal Doppler) or Pressure Monitoring Mode (EDM+ only) are intended for use with adult and pediatric patients. When the CardioQ-EDM series monitors are used for High-Definition Impedance CardioGraphy with a PhysioFlow Q-Link module the intended use is for adult patients only.

    Device Description

    The CardioQ-EDM series are medical instruments designed to monitor cardiac function and fluid status. The CardioQ-EDM & EDM+ achieve this by combining Doppler measurements of the blood flow (4MHz continuous wave ultrasound) to monitor and quantify the blood flow in the descending thoracic aorta. In addition to this the CardioQ-EDM+ previously introduced as an upgrade to the EDM under (K132139) allows additional Pulse Pressure Waveform Analysis (PPWA) through arterial blood pressure based parameters slaved from a high-end monitor.

    The CardioQ-EDM (K111542) & Cardio EDM+ (K132139) have now been introduced with the addition of a USB Hub accessory and software modifications that allow the CardioQ-EDM series monitors to display hemodynamic parameters from the coupled together hemodynamic impedance cardiography device.

    The addition of USB Hub accessory and software modifications allow the CardioQ-EDM series monitors to become a non-invasive cardiac output measurement system which displays hemodynamic parameters, allowing analysis of a trans-thoracic impedance cardiography signal & cardiac output monitoring. The only addition to the CardioQ-EDM & CardioQ-EDM+ is the enabling of HD-ICG functionality through the USB Hub accessory introduction and software modifications to display the hemodynamic parameters from the coupled hemodynamic impedance cardiography device.

    AI/ML Overview

    The provided document is a 510(k) summary for the Deltex Medical CardioQ-EDM and Deltex Medical CardioQ-EDM+ device. It outlines the regulatory submission, device description, intended use, technological features, and a summary of completed testing.

    However, the document does not contain any information about acceptance criteria or a study that specifically proves the device meets acceptance criteria related to its performance in terms of accuracy or efficacy, particularly concerning AI or algorithms. The submission focuses on substantial equivalence to predicate devices, primarily due to software modifications and the addition of a USB hub accessory to enable the display of hemodynamic parameters from a coupled impedance cardiography device.

    Therefore, I cannot extract the detailed information requested in the prompt. The document explicitly states:

    • "No Acoustic Output Testing has been conducted, because the CardioQ-EDM series monitors are only displaying data rather than performing any primary calculations are conducted by the hemodynamic impedance cardiography device coupled to the CardioQ-EDM series monitors."
    • "No animal testing was conducted in support of this 510(k)."
    • "No clinical testing was conducted in support of this 510(k)."

    The "Bench Testing" mentioned is comparative and aims to show that "the software modifications and introduced USB Hub accessory have enabled additional HD-ICG functionality to be introduced to the existing CardioQ-EDM series monitors" and that "the software correctly displays the information received from the coupled hemodynamic impedance cardiography device without any manipulation of the coupled device." This is a functional verification, not a performance study against specific acceptance criteria for a new clinical claim or algorithm.

    The document discusses "Letter-to-File Changes" for "Addition of Cardiac Power (CPO) and Cardiac Power Index (CPI)" and "Addition of Elastance (Ea) and Dynamic Arterial Elastance (Eadyn)," citing published papers to validate the use of these formulae. This indicates that the device displays these calculated parameters, but the 510(k) submission itself does not contain a study proving the device's performance in calculating or displaying these against acceptance criteria from a statistical clinical trial.

    In summary, based on the provided text, the document does not contain the information required to answer your specific questions regarding acceptance criteria and performance studies for an AI/algorithm-driven device. The device described here is a display unit for parameters calculated by another coupled device and its assessment is for substantial equivalence relating to software and hardware changes enabling this display functionality.

    Ask a Question

    Ask a specific question about this device

    K Number
    K150347

    Validate with FDA (Live)

    Date Cleared
    2015-07-24

    (163 days)

    Product Code
    Regulation Number
    870.2100
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Deltex Medical CardioQ-EDM+ / Deltex Medical CardioQ-EDM cardiac function and fluid status monitoring system is designed to provide clinicians with real-time information about a patient's left ventricular blood flow and key hemodynamic parameters. The Deltex Medical CardioQ-EDM+ / Deltex Medical CardioQ-EDM beat-to-beat data on cardiovascular status can be used by the managing clinician to evaluate and optimize hemodynamic performance in anesthetized, sedated or conscious patients in the operating room, intensive care unit, emergency room or ward.

    Device Description

    The Deltex Medical CardioQ-EDM series are medical instruments designed to monitor cardiac function and fluid status. The CardioQ-EDM series combine Doppler measurement of the blood flow (4MHz continuous wave ultrasound) with Pulse Pressure Waveform Analysis (PPWA) to monitor and quantify the blood flow in the descending thoracic aorta and hence calculate other clinically significant information.

    AI/ML Overview

    The provided document is a 510(k) premarket notification for the Deltex Medical CardioQ-EDM+ / Deltex Medical CardioQ-EDM, a cardiovascular blood flowmeter. The submission focuses on minor software changes to extend the range of volumetric calculations and accommodate future probe additions, rather than a new standalone device with extensive clinical studies. Therefore, much of the requested information regarding detailed acceptance criteria, specific study designs, or human-in-the-loop performance is not present.

    Here's a breakdown of the available information:

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Correct probe identificationDemonstrated correct identification.
    Appropriate formula and Body Surface Area (BSA) algorithm selection based on probe identificationDemonstrated appropriate selection.
    Software correctly implements new formula and algorithmsConfirmed through code examination.
    Displayed values match "by hand" calculated values (simulation testing)Confirmed through simulation testing.
    Device is as safe and effective as predicate devices (CardioQ-EDM K111542, CardioQ-EDM+ K132139)Concluded by Deltex Medical based on the above testing and the nature of the software changes (not affecting ultrasonic performance or linear data measurement).

    2. Sample size used for the test set and the data provenance

    The document does not specify a "test set" in the context of patient data. The testing described focuses on software functionality.

    • Test Set Sample Size: Not applicable in the context of patient data. Testing involved simulation and code examination concerning formula selection and calculation.
    • Data Provenance: Not applicable, as no patient data was used for this particular submission. The changes are software-based.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. Ground truth for the software's functionality was established through internal code examination and "by hand" calculations during simulation testing. No external experts or medical professionals were mentioned for this specific validation.

    4. Adjudication method for the test set

    Not applicable. The validation was based on software implementation and calculation accuracy, not on expert adjudication of clinical data.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No. This document describes a software update for a medical device that measures hemodynamic parameters, not an AI or imaging diagnostic tool. Therefore, an MRMC study comparing human reader performance with and without AI assistance is not relevant or mentioned.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Yes, in a way. The testing focused on the algorithm's functional correctness ("software correctly implements the formula and algorithms" and "values displayed match those calculated 'by hand'"). However, this is distinct from "standalone performance" in the context of a diagnostic AI algorithm. Here, it refers to the accuracy of the device's internal calculations.

    7. The type of ground truth used

    For the specific software changes:

    • Ground Truth: Verification that the software's internal logic for probe identification, formula selection, and volumetric calculations aligns with predefined expectations and manual calculations. This assumes the underlying physiological models and formulas used are already well-established.

    8. The sample size for the training set

    Not applicable. This submission concerns a software update to an existing device, primarily focused on formula selection and calculation. It does not involve machine learning or AI models that require a "training set" of data.

    9. How the ground truth for the training set was established

    Not applicable, as there was no training set for a machine learning algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K142932

    Validate with FDA (Live)

    Date Cleared
    2015-01-22

    (105 days)

    Product Code
    Regulation Number
    870.2120
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The probe is for use with the Deltex Medical CardioQ-EDM and CardioQ-EDM+ for Monitoring of cardiac output and fluid status. The probe is only approved for oral placement into the esophagus of a single anesthetized patient 15 years of age or younger, 50cm (20") to 170cm (67") in height.

    Device Description

    The Deltex Medical Ltd KDP72 Pediatric Doppler Probe is an oral extravascular blood flow probe designed to work with the CardioQ-EDM and CardioQ-EDM+ Systems (K111542 and K132139 respectively). It consists of a shaft, which is a spring reinforced silicone tube, with an electrical connector on the machine end and an ultrasonic transmitting and receiving tip on the patient end. The tip is fully covered and sealed to the shaft with a silicone rubber boot and by wires running through the shaft to the connector. Visual product identification is provided at the machine end and the device is provided single packed sterile for single patient use.

    AI/ML Overview

    The provided document is a 510(k) summary for the Deltex Medical KDP72 Doppler Probe, asserting its substantial equivalence to previously cleared devices. It describes the device, its intended use, and performance data related to its design and safety standards, but does not contain information about a study proving the device meets specific acceptance criteria related to its clinical performance as a diagnostic tool for cardiac output and fluid status.

    The "Performance Data" section briefly mentions:

    1. "The performance data recommended in 'Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers,' issued on September 9, 2008, has been included." This suggests that general requirements for diagnostic ultrasound devices were addressed, likely related to acoustic output and image quality, not the accuracy of cardiac output measurements.
    2. "Additionally a flexibility test has been conducted on the subject and predicate devices which demonstrates the comparative flexibility." This is a mechanical performance test, not a clinical diagnostic performance study.

    Therefore, many of the requested categories for acceptance criteria and a study to prove they are met cannot be extracted from this document, as the document focuses on demonstrating substantial equivalence based on design, materials, sterilization, biocompatibility, and electrical safety standards rather than clinical diagnostic accuracy.

    However, based on the provided text, here’s what can be extracted:

    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria CategoryAcceptance CriteriaReported Device Performance (KDP72 Doppler Probe)
    SterilizationSterilized in accordance with ISO 11135-1 (version of standard current at time of submission).Meets ISO 11135-1 (version current at submission).
    Shelf LifeMeets ISO 11607-1 (version of standard current at time of submission).Meets ISO 11607-1 (version current at submission).
    BiocompatibilityTested in accordance with ISO 10993-5 (Cytotoxicity), ISO 10993-10 (Irritation and Skin Sensitization), ISO 10993-7 (Ethylene Oxide Sterilization Residuals) (version of standard current at time of submission). Note: ISO 10993-7 is about ETO residuals, not a direct biocompatibility test type, but often included for ETO sterilized devices.Meets ISO 10993-5, ISO 10993-10, ISO 10993-7 (versions current at submission).
    EMC and Electrical SafetyMeets IEC 60601-1 (Medical Electrical Equipment - General requirements for basic safety and essential performance), IEC 60601-1-2 (Electromagnetic disturbances - Requirements and tests), IEC 60601-2-37 (Particular requirements for the basic safety and essential performance of ultrasonic medical diagnostic and monitoring equipment) (version of standard current at time of submission).Meets IEC 60601-1, IEC 60601-1-2, IEC 60601-2-37 (versions current at submission).
    PackagingMeets ISO 11607-1 (Packaging for terminally sterilized medical devices - Requirements for materials, sterile barrier systems and packaging systems), ISO 11607-2 (Packaging for terminally sterilized medical devices - Validation requirements for forming, sealing and assembly processes) (version of standard current at time of submission).Meets ISO 11607-1, ISO 11607-2 (versions current at submission).
    FlexibilityDemonstrates comparative flexibility to predicate devices. (No specific quantitative acceptance criterion stated).Flexibility test conducted; demonstrates comparative flexibility.
    Diagnostic Ultrasound Performance DataBased on "Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers", issued on September 9, 2008. (Likely relates to acoustic output, measurement accuracy of general ultrasound parameters, not necessarily cardiac output accuracy specifically)."Included" (no specific results provided).

    2. Sample size used for the test set and the data provenance:
    Not specified in the document for any clinical performance or diagnostic accuracy study. The document mentions a flexibility test, but details on sample size or provenance are not provided.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
    Not applicable/not specified. The document does not describe a study involving expert-established ground truth for clinical diagnostic performance.

    4. Adjudication method for the test set:
    Not applicable/not specified.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
    Not applicable. This device is a probe for a cardiac output monitor, not an AI-assisted diagnostic imaging system that involves human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
    Not specified. The document refers to "performance data recommended in 'Information for Manufacturers Seeking Marketing Clearance of Diagnostic Ultrasound Systems and Transducers'" but does not detail what kind of study was performed or if it was standalone. The device is a probe to be used with a monitoring system, implying a system performance, not a standalone algorithm.

    7. The type of ground truth used:
    Not specified for diagnostic accuracy. For the engineering criteria (sterilization, biocompatibility, etc.), the ground truth is established by adherence to the respective international standards (e.g., ISO, IEC).

    8. The sample size for the training set:
    Not applicable/not specified. No information on an algorithm training set is provided; this is a medical device (probe) for measurement, not an AI/ML diagnostic algorithm.

    9. How the ground truth for the training set was established:
    Not applicable/not specified.

    Ask a Question

    Ask a specific question about this device

    K Number
    K132139

    Validate with FDA (Live)

    Date Cleared
    2013-10-10

    (91 days)

    Product Code
    Regulation Number
    870.2100
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CardioQ-EDM+ cardiac function and fluid status monitoring system is designed to provide clinicians with real-time information about a patient's left ventricular blood flow and key hemodynamic parameters. The CardioQ-EDM+ beat-to-beat data on cardiovascular status can be used by the managing clinician to evaluate and optimize hemodynamic performance in anesthetized, sedated or conscious patients in the operating room, intensive care unit, emergency room or ward.

    Device Description

    The CardioQ-EDM+, is a medical instrument designed to monitor cardiac function and fluid status, providing clinicians with real-time information about a patient's left ventricular blood flow and key hemodynamic parameters in anesthetized, sedated or conscious patients in the operating room, intensive care unit, emergency room or ward. In addition, the CardioQ-EDM+ includes a function to calculate arterial blood pressure based parameters from an output slaved from a vital signs monitor. The CardioQ-EDM+ combines Doppler measurement of blood flow with Pulse Pressure Waveform Analysis (PPWA). In "Flow Monitoring Mode" the system employs esophageal Doppler monitoring (EDM) techniques using 4 MHz continuous wave ultrasound to monitor and quantify the blood flow in the descending thoracic aorta. displaying this data as a maximum velocity curve, a velocity spectrum and derived measurements. Real-time information about cardiac function, in particular left ventricular flow, is displayed continuously. For the CardioQ-EDM+, the newly added "Pressure Monitoring Mode" the system slaves the arterial blood pressure signal supplied by the hospital patient monitoring system to provide systolic and diastolic pressures and derived parameters. The CardioQ-EDM+ uses these classical blood pressure measurements to calculate Stroke Volume (SV), Cardiac Output (CO), Stroke Volume Variation (SVV). Pulse Pressure Variation (PPV) and a small number of derived parameters. The pressure derived stroke volume is calibrated from the CardioQ-EDM+'s Doppler ultrasound measurement of stroke volume ensuring consistency and allowing frequent recalibration.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and study information for the Deltex Medical CardioQ-EDM+ device, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    The provided 510(k) summary does not contain a specific table detailing acceptance criteria for the CardioQ-EDM+ device's performance in terms of accuracy, precision, sensitivity, or specificity. Instead, the submission focuses on demonstrating substantial equivalence to a predicate device (CardioQ-EDM) by highlighting that the new device is a modification incorporating additional functionalities for blood pressure-based parameter calculation.

    The performance comparison is implicitly made through the "Comparison technological features" table, which shows that the CardioQ-EDM+ offers the same ranges for directly measured Doppler parameters as the predicate device. The new "Pressure Monitoring Mode" adds new calculated parameters with specified ranges, but these are not compared against a defined acceptance criterion from a performance study within this document.

    Implicit Performance Claim (based on substantial equivalence):
    The CardioQ-EDM+ is designed to provide real-time information about a patient's left ventricular blood flow and key hemodynamic parameters, similar to the predicate device. The new pressure-based calculations are presented as additions to the existing capabilities, relying on the established performance of the Doppler measurement and the slaved arterial blood pressure signal.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size:
      • Clinical Testing: The document explicitly states: "No clinical testing was conducted in support of this 510(k)." Therefore, there is no clinical test set sample size.
      • Bench Testing: The document mentions "Comparative bench testing," but does not provide details on the number of samples, cases, or specific data points used in this testing.
    • Data Provenance: Not applicable for clinical data. For bench testing, the provenance is internal to Deltex Medical, as it was "Comparative bench testing... using a CardioQ-EDM Cardiac Output and Fluid Status Monitoring System (K111542)."

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    Since "No clinical testing was conducted in support of this 510(k)," there was no ground truth established by experts for a clinical test set.

    4. Adjudication Method for the Test Set

    Not applicable, as no clinical test set was used to establish performance against a ground truth.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • Was it done? No. The document explicitly states: "No clinical testing was conducted in support of this 510(k)."
    • Effect size of human readers improvement: Not applicable, as no such study was performed.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    While the device operates as a standalone monitoring system, the term "standalone study" typically refers to an evaluation of an AI algorithm's performance independent of human input or review. As this device is a medical instrument (hardware and integrated software) designed to measure physiological parameters rather than an AI-driven diagnostic or interpretative tool, this concept doesn't directly apply in the same way it would for, for instance, an AI-powered image analysis product.

    The device's performance is demonstrated through its ability to measure and calculate parameters, and the validation of these calculations would be part of the bench testing. The 510(k) focuses on the "substantial equivalence" of the device, particularly the new features, to the predicate. The "Bench Testing" section confirms that the new device's performance is substantially equivalent to the predicate, implying that the algorithm's calculations were validated against expected outputs or the predicate's known outputs, but specific details of this validation are not provided.

    7. Type of Ground Truth Used

    • Clinical: Not applicable, as no clinical testing was performed.
    • Bench Testing: The implicit ground truth for the bench testing would have been reference measurements or known values used to compare the CardioQ-EDM+ against the predicate CardioQ-EDM. The document states: "Comparative bench testing... supports the conclusion that the two systems have substantially equivalent performance." This implies that the CardioQ-EDM+'s outputs for new and existing parameters were compared against established and accepted values (e.g., from the predicate device or simulated physiological signals) during bench testing.

    8. Sample Size for the Training Set

    This device does not appear to use machine learning or AI in a way that requires a "training set" in the conventional sense (e.g., for image recognition or predictive modeling from a large dataset). Its algorithms are based on established physiological principles and signal processing for Doppler measurements and arterial pressure analysis. Therefore, there's no reported training set sample size.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no apparent training set for machine learning. The algorithms are likely deterministic and based on validated mathematical models and physiological relationships.

    Ask a Question

    Ask a specific question about this device

    K Number
    K111542

    Validate with FDA (Live)

    Date Cleared
    2011-10-20

    (140 days)

    Product Code
    Regulation Number
    870.2100
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CardioQ-EDM cardiac function and fluid status monitoring system is designed to provide clinicians with real-time information about a patient's left ventricular blood flow and key hemodynamic parameters. The CardioQ-EDM's beat-to-beat data on cardiovascular status can be used by the managing clinician to evaluate and optimize hemodynamic performance in anesthetized, sedated or conscious sedated patients in the operating room, intensive care unit, emergency room or ward.

    Device Description

    The CardioQ-EDM system employs esophageal Doppler techniques using 4 MHz continuous thoracic aorta, displaying this data as a maximum velocity curve, a descriting there is derived measurements. Thus, real-time information about verouty opesant in particular left ventricular flow, is displayed continuously. This is the same as for the predicate CardioQ K031706. CardioQ-EDM is an enhancement of the CardioQ K031706; obsolete The components have been replaced and an improved/modernized user interface created, by utilizing the full capabilities of the new components.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the Deltex Medical CardioQ-EDM Esophageal Doppler Monitor, aiming to demonstrate substantial equivalence to a predicate device (Deltex Medical CardioQ - K031706). Since it's a 510(k) submission, the "acceptance criteria" are implied by comparing the new device's performance to the legally marketed predicate device, rather than explicit numerical thresholds typically seen in AI/ML performance studies. The study described is a comparative bench study.

    Here's the breakdown of the information requested based on the provided text, recognizing that it's a medical device submission focused on substantial equivalence rather than AI/ML performance:


    1. Table of Acceptance Criteria and Reported Device Performance

    For a 510(k) submission, acceptance criteria are generally to demonstrate that the new device (CardioQ-EDM) performs as safely and effectively as the predicate device (CardioQ K031706). The "reported device performance" is the conclusion of the bench testing that substantial equivalence was achieved. Specific numerical acceptance criteria are not explicitly stated for individual device parameters, but rather the overall conclusion of comparable performance across all listed characteristics.

    Feature/ParameterAcceptance Criteria (Implied - substantial equivalence to predicate)Reported Device Performance (CardioQ-EDM)
    Indications for UseSame as predicate (with minor textural updates)Same as predicate
    Patient PopulationSame as predicateSame as predicate
    Patient StatusSame as predicateSame as predicate
    Insertion RouteOral or NasalOral or Nasal (predicate was Oral, Nasal added later)
    ContraindicationsSame as predicateSame as predicate
    System DesignSame as predicateSame as predicate
    System ComponentsFunctionally equivalent/improved as predicateUpdated components, modernized user interface
    Mode of OperationSame as predicateSame as predicate
    Ultrasonic Clutter RejectionSame as predicateSame as predicate
    Spectral DisplaySame as predicateSame as predicate
    Velocity Spectrum Display Time Range (x-axis)Performance comparable to predicateFull screen: 4.3 seconds (Predicate: 3.6 sec) Split screen: 1.4 seconds (Predicate: 1.4 sec)
    Velocity Display Scales (y-axis)Performance comparable to predicate50, 100, 200 cm/s, 250 cm/s (Predicate: 50, 100, 200 cm/s)
    Doppler Audio ConfirmationSame as predicateSame as predicate
    DisplayPerformance comparable to predicateColor 10.4" TFT LCD screen (800 x 600 pixels) (Predicate: 640 x 480 pixels)
    Ranges of Directly Measured ParametersComparable to or improved from predicatePeak Velocity (PV) 10 - 250 cm/s (Predicate: 10 - 220 cm/s) Other parameters same range
    Ranges of Calculated ParametersSame as predicateSame as predicate
    Operating ModesSame as predicateSame as predicate
    Controls & User InterfacePerformance and functionality comparable to predicateSimilar controls with updated implementation
    Parameters DisplayedPerformance comparable to predicate, with potential for improvement/increase of displayed parametersEight of listed parameters displayed (Predicate: Six)
    Parameters Update RateSame as predicateSame as predicate
    Trend HistoryPerformance comparable to or improved from predicateUp to 240 hours/Unlimited (Predicate: Up to 48 hours)
    Trend Temporal ResolutionSame as predicateSame as predicate
    Acoustic OutputCompliance with NEMA UD 2Compliant with NEMA UD 2
    Electrical Safety & EMCCompliance with IEC 60601 seriesCompliant with IEC 60601 series
    Overall PerformanceSubstantially equivalent to predicateSubstantially equivalent performance achieved

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: This was a bench testing study, therefore there is no "patient test set" in the traditional sense. The comparison was between the physical device (CardioQ-EDM) and the predicate device (CardioQ K031706) within a laboratory/bench environment. The text does not specify a "sample size" of individual tests or measurements, but rather refers to "Comparative bench testing of the CardioQ-EDM... using a CardioQ..."
    • Data Provenance: The study was conducted by Deltex Medical Limited, based in the United Kingdom. The data is from bench testing, implicitly a prospective assessment of the new device's engineering and performance characteristics against the predicate's known specifications and performance.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • Not applicable. For this type of device (a diagnostic/monitoring tool) and study (bench testing for substantial equivalence), "expert ground truth" as understood in clinical evaluation or AI/ML performance is not relevant. The "ground truth" for the bench testing would be the engineering specifications and validated performance characteristics of the predicate device, against which the new device's measurements and functionalities were compared. This would be established by experts in device design, testing, and regulatory compliance, but not in the sense of clinical annotation.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • None. This concept is not applicable to bench testing where objective measurements and engineering specifications are compared. Discrepancies would be resolved through engineering re-evaluation or re-testing, not through a consensus-based adjudication of clinical observations.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, an MRMC study was NOT done. This submission is for a medical device (Esophageal Doppler Monitor), not an AI/ML diagnostic tool. Therefore, the concept of "human readers improve with AI vs without AI assistance" is not relevant. The device measures physiological parameters, and its performance is assessed against directly measured physical quantities or established specifications.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    • Not applicable in the context of AI/ML algorithms. The CardioQ-EDM is a standalone medical device that provides direct measurements and calculated parameters. Its "standalone performance" refers to its ability to accurately measure and compute these physiological metrics as designed, compared to the predicate device. It's not an AI algorithm that processes data to generate a finding that a human then interprets or acts upon.

    7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)

    • The "ground truth" for the bench testing was primarily the engineering specifications and established performance characteristics of the predicate device (CardioQ K031706), along with compliance with recognized consensus standards (IEC 60601 series for electrical safety/EMC, NEMA UD 2 for acoustic output). The goal was to show that the new device met or exceeded these, demonstrating substantial equivalence.

    8. The sample size for the training set

    • Not applicable. This submission is for a medical device that does not use machine learning algorithms, thus there is no "training set."

    9. How the ground truth for the training set was established

    • Not applicable. As there is no training set, there is no ground truth established for it.
    Ask a Question

    Ask a specific question about this device

    K Number
    K073593

    Validate with FDA (Live)

    Date Cleared
    2009-01-29

    (405 days)

    Product Code
    Regulation Number
    870.2120
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The I2 probe is for use with the Deltex Medical CardioQ for the monitoring of cardiac output and fluid status. The I₂ is only approved for oral or nasal placement into the esophagus of a single patient 16 years of age or older. The probe may be placed orally or nasally in sedated or anesthetized patients. The probe must be placed nasally in awake patients.

    Device Description

    Esophageal probe for measuring blood flow in the descending aorta. Sterile. For single use only. Overall length 89 cm (35"). Shaft construction Spring enclosed in silicone rubber. Shaft color Clear (non-pigmented) shaft. Shaft flexibility (N) 0.095. Main shaft diameter 14 FG (~4.8 mm). Distal tip diameter 19FG (~6.3 mm). Maximum Usage time (hours) 6, 24 or 72. Main shaft wall thickness 0.03" (~0.7mm). Marks in the shaft The probe shaft has three depth markers at 35, 40 and 45 cm. Color of transducer head "clear" (non-pigmented). Color of the molded connector "white" (pigmented). Color of the shaft "clear" (non-pigmented). Connection to the monitor non-reversible connector with ROM to identify probe type. Doppler transducer / Central frequency 4MHz. Doppler transducer / Global maximum output 195 mW/cm². Doppler transducer / Mechanical index 0.039. Spring wire 0.030" (0.76 mm) diameter to BS5216 HS3, Pre-galvanized. Spring length 550mm (+/- 25 mm). Spring internal diameter 1.80/2.00 mm. Spring external diameter 3.30/3.50 mm. Spring pitch The spring has fewer turns per unit of length (it has a larger pitch than DP 240). ROM memory This ROM memory is characteristic for the particular probe. Mode of operation Esophageal probe transmits and receives 4 MHz Continuous Wave Doppler (CWD) ultrasound from the probe tip at a fixed angle to the descending aorta, by excitation of a piezo-electric transducer. The ultrasound is reflected by the red blood cells and is received by a separate transducer in the probe tip. Signals are returned via the Patient Interface Cable (PIC) to CardioQ Monitor. This permits to measure blood flow velocities in the descending thoracic aorta. Compatible Monitor CardioQ monitor. Rx Status Rx. Physicians Caution included in labeling Yes.

    AI/ML Overview

    The provided document is a 510(k) Summary for the Deltex Medical Ltd I2n Series Doppler Probe. It primarily focuses on demonstrating substantial equivalence to previously cleared predicate devices rather than presenting a standalone study with specific acceptance criteria and performance data for the subject device.

    Therefore, many of the requested elements regarding acceptance criteria, study design, and performance metrics are not explicitly stated within this 510(k) summary. The document focuses on comparing the design and materials of the new I2n Series probe to existing predicate devices (DP240 Hour Doppler Probe, CardioQ Probe, and Hemosonic 100 Esophageal Probe). The "study" mentioned is implicitly a comparison of physical and operational specifications to demonstrate equivalence, rather than a clinical performance study with defined acceptance criteria.

    Specific answers to your questions based on the provided text:

    1. Table of acceptance criteria and the reported device performance:
      The document does not explicitly present acceptance criteria or reported device performance in the format of a clinical performance study with quantitative results against predefined thresholds. Instead, it provides a comparative table outlining the features of the subject device (I2n-series) against three predicate devices. The "performance" demonstrated is through feature-by-feature comparison, indicating that the new device is either identical or has minor, non-significant differences from the predicates, particularly highlighting the improved shaft flexibility.

      Implicit Comparison Table (derived from the document's comparative table):

    FeatureAcceptance Criteria (based on Predicate)Deltex Medical 'I₂n-series' Performance (reported)
    Overall length~89-90 cm (from predicates)89 cm (35") - Same as DP240
    Shaft constructionSpring enclosed in silicone rubberSame
    Shaft colorClear (non-pigmented) or White (pigmented)Clear (non-pigmented) shaft - Difference from CardioQ, but functionally equivalent or improved by removing pigment.
    Shaft flexibility (N)E.g., < 1.6 N (from DP240/CardioQ)0.095 N - Significantly improved (lower resistance). This is a key difference highlighted as an improvement for easier insertion.
    Main shaft diameter~4.8 mm or ~5.5 mm (from predicates)14 FG (~4.8 mm) - Same as DP240.
    Distal tip diameter~6.3 mm or ~7 mm (from predicates)19FG (~6.3 mm) - Same as DP240 and CardioQ.
    Maximum Usage timeSingle use; < 10 days/240 hours6, 24 or 72 hours (Single use) - Consistent with predicates DP240/CardioQ in 'single use' and 'time-out' concept.
    Main shaft wall thickness~0.7 mm or ~1.0 mm (from predicates)0.03" (~0.7mm) - Same as DP240.
    Depth markersMarkers at various lengths (e.g., 35, 40, 45 cm)Three depth markers at 35, 40 and 45 cm. - Similar to predicates, with more markers than CardioQ.
    Transducer head color"clear" (non-pigmented) or "white" (pigmented)"clear" (non-pigmented) - Difference from predicates, but functionally equivalent or improved.
    Molded connector color"white" (pigmented)"white" (pigmented) - Same as Deltex predicates.
    Spring pitchMore turns per unit length (smaller pitch)Fewer turns per unit of length (larger pitch than DP240). - This is a key difference contributing to improved flexibility (0.095N vs 1.57N).
    Doppler frequency4 MHz or 5 MHz (from predicates)4 MHz - Same as Deltex predicates.
    Doppler output< 195 mW/cm² (from predicates)195 mW/cm² - Same as Deltex predicates.
    Mechanical index< 0.089 (from predicates)0.039 - Same as Deltex predicates.
    Compatible MonitorCardioQ monitor (for Deltex devices)CardioQ monitor - Same as Deltex predicates.
    Indication for UseOral/nasal insertion, anesthetized/sedated patientsOral or nasal use in anaesthetized or sedated patients; nasal use in conscious and sedated patients. - Expanded indication due to flexibility improvement.
    The "acceptance criteria" here are essentially "substantially equivalent to" or "demonstrates an equivalent or improved characteristic compared to" the predicate devices for each feature. The study demonstrates this equivalence through a detailed comparison of specifications and materials.
    

    2. Sample size used for the test set and the data provenance:
    No specific "test set" with a defined sample size (e.g., number of patients or cases) is described in the context of a clinical performance study. The data provenance is from internal testing and comparison against the specifications of existing devices, manufactured by Deltex Medical Ltd, located in the United Kingdom. This is a comparison of device specifications and changes rather than a clinical trial.

    1. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
      Not applicable, as no clinical test set requiring expert ground truth establishment is described. The assessment is based on engineering specifications and comparison with predicate devices.

    2. Adjudication method for the test set:
      Not applicable, as no clinical test set requiring adjudication is described.

    3. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
      Not applicable. This device is an extravascular blood flow probe, not an AI-assisted diagnostic imaging device.

    4. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
      Not applicable. This is a physical medical device, not an algorithm.

    5. The type of ground truth used:
      The "ground truth" implicitly used for demonstrating substantial equivalence is the established performance and safety profile of the predicate devices based on their 510(k) clearances and recognized standards for material, manufacturing, and performance characteristics. For instance, the stated flexibility (0.095 N) is a directly measured characteristic of the new device which is then compared against the measured flexibility of the predicate.

    6. The sample size for the training set:
      Not applicable, as there is no machine learning or AI component requiring a training set.

    7. How the ground truth for the training set was established:
      Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K052989

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2006-03-08

    (135 days)

    Product Code
    Regulation Number
    870.2120
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    When used in conjunction with the CardioQ cardiac output and fluid status monitoring system, the DP240 is designed to provide clinicians with real-time information about left-ventricular blood flow. The DP240 is designed to operate in a clinical setting in which the patients are under general anesthesia or are sedated in the intensive care unit. The DP240 can be placed into the esophagus via oral or nasal insertion in adults.

    Device Description

    When used in conjunction with the Cardiac output and fluid status monitoring system (K031706), the DP240 is designed to provide clinicians with real-time information about leftventricular function by measuring blood flow in the descending thoracic aorta. The probe is designed to operate in a clinical setting in which patients are under general anesthesia or sedated in the intensive care unit.

    The DP240 transmits a 4 MHz continuous wave ultrasonic 'carrier' signal from the probe tip at a fixed angle to the descending aorta, by excitation of a piezo-electric transducer. The ultrasound is reflected by the red blood cells and is received by a separate transducer in the probe tip.

    The DP240 is placed orally or nasally and inserted into the esophagus to a depth of 35 – 45 cm, (approx. 14" - 18") for insonation of the descending thoracic aorta at the 6" thoracic vertebra (approximately). The shaft and tip of the DP240 is the only component in contact with the patient and is manufactured with an outer insulating cover of medical grade silicone rubber. The probe is flexible and has a shaft diameter of 14 French (~4.8 mm, approx. 0.18"). The probe is supplied sterile and is for single-use only in adults.

    AI/ML Overview

    This 510(k) submission for the DP240 240 Hour Doppler Probe is a premarket notification aiming to demonstrate substantial equivalence to previously cleared devices. It does not contain information about acceptance criteria or a study proving the device meets those criteria. The provided text is a standard 510(k) summary and FDA clearance letter, which focuses on device description, intended use, and comparison to predicate devices, rather than detailed performance studies and acceptance criteria typically found in clinical trial reports or engineering validation documents.

    Therefore, I cannot fulfill the request to describe the acceptance criteria and a study proving the device meets those criteria based solely on the provided text. The requested information regarding sample sizes, ground truth establishment, expert qualifications, adjudication methods, MRMC studies, standalone performance, and training set details are not present in this document.

    Ask a Question

    Ask a specific question about this device

    K Number
    K031706

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2003-08-06

    (65 days)

    Product Code
    Regulation Number
    870.2100
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CardioQ cardiac output and fluid status monitoring system is designed to provide clinicians with real-time information about left-ventricular blood flow. The CardioQ is designed to operate in a clinical setting in which the patients are under general anesthesia or are sedated in the intensive care unit. The CardioQ offers the anesthetist and intensive care physician with beat-to-beat data on cardiovascular status and circulating blood volume, providing immediate feedback on the effect of any therapeutic intervention.

    Device Description

    The CardioQ cardiac output and fluid status monitoring system is designed to provide clinicians with real-time information about left-ventricular blood flow. The CardioQ is designed to operate in a clinical setting in which the patients are under general anesthesia or are sedated in the intensive care unit. The CardioQ offers the anesthetist and intensive care physician with beat-to-beat data on cardiovascular status and circulating blood volume, providing immediate feedback on the effect of any therapeutic intervention.

    The CardioQ system employs esophageal Doppler using 4 MHz continuous wave ultrasound to monitor and quantify the blood flow in the descending thoracic aorta, displaying this data as a maximum velocity curve, a velocity spectrum and derived measurements. Thus, real-time information about cardiac function and haemodynamic status, in particular flow, is displayed continuously.

    The CardioQ system transmits the 4 MHz ultrasonic 'carrier' signal from the probe tip at a fixed angle to the descending aorta, by excitation of a piezo-electric transducer. The ultrasound is reflected by the red blood cells and is received by a separate transducer in the probe tip. Blood flow away from the probe results in frequencies less than 4 MHz being present in the received signal. Conversely, any reverse flow will produce frequencies higher than the carrier.

    The received signal is first demodulated, such that those frequencies corresponding to the blood flow are extracted and displayed as a real-time velocity spectrum. The spectrum displays the distribution of red blood cell velocities at a given point in time, i.e. a histogram of velocities over time. Thus, the brightness at any point in the spectrum is directly proportional to the number of red blood cells traveling at a given velocity at a given time in the cardiac cycle.

    The CardioQ automatically traces the maximum velocity of the spectrum at each time point. By calculating the area under this maximum-velocity curve during systole, a beat-to-beat value for Stroke Distance (SD) is given, being the distance a column of blood moves in the aorta during systole. Using a proprietary algorithm called the nomogram, the CardioQ estimates Stroke Volume (SV) using the measured SD and the size and age of the patient. The Stroke Volume is the volume of blood output by the heart during systole. Since the machine automatically calculates the patient's heart rate (HR) from the spectrum, it can also provide a beat-to-beat measurement of Cardiac Output (SV*HR). Other parameters calculated include:

    • . Peak Velocity (PV) - highest blood velocity recorded during systole
    • Mean Acceleration (MA) acceleration of the blood at the beginning of systole ●
    • Corrected Flow Time (FTc) systolic flow time (normalized to 60 bpm) .
    • Cardiac Index (CI) cardiac output normalized to body surface area o
    • Minute Distance (MD) a linear surrogate for cardiac output, being the distance a . column of blood moves in the aorta in one minute

    The CardioQ Cardiac Output and Fluid Status Monitoring System is comprised of the following components:

    CardioQ monitor
    Esophageal Doppler monitor (including power cord) which generates and processes the transmitted and received ultrasound signals, displays the resulting velocity spectrum and calculates the associated cardiac parameters. It is connected to the probe via the patient interface cable. The monitor displays the waveform and numerical data on a 10.4" color TFT LCD screen, which also provides the user interface and 'help' text. The monitor is operated by a large rotary 'encoder' knob and six 'soft' buttons whose function depends on the current screen mode. The monitor operates from a 100 – 240V A.C. supply.

    Patient Interface Cable
    6' 3" long interconnect cable between the CardioQ monitor and probe, providing signal amplification and electrical isolation.

    CardioQ probe
    Esophageal Doppler monitor probe is placed orally and inserted to a depth of 35 – 40 cm. (approx. 14" - 16") for insonation of the descending thoracic aorta at the 60 thoracic vertebra (approximately). The CardioQ probe is the only component in contact with the patient and is manufactured with an outer insulating cover of medical grade silicone rubber. The probe is flexible and has a shaft diameter of 17 French (~5.5 mm, approx. 0.22"). The probe is supplied sterile and is for single-use only.

    AI/ML Overview

    The provided text describes the CardioQ Cardiac Output and Fluid Status Monitoring System, but does not contain information about acceptance criteria or a specific study proving the device meets acceptance criteria. The document is a 510(k) summary for a premarket notification, indicating substantial equivalence to previously cleared devices. It mainly focuses on device description, intended use, and the FDA's clearance letter.

    Therefore, I cannot provide the requested information from the given text.

    The information sought, such as acceptance criteria, reported device performance, sample sizes, data provenance, expert qualifications, ground truth establishment, adjudication methods, and details of MRMC or standalone studies, are typically found in detailed validation studies or clinical trial reports, which are not present in this 510(k) summary.