Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K030340

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2003-04-11

    (70 days)

    Product Code
    Regulation Number
    862.2050
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AutoloGel Process Centrifuge is designed to be used at the patient's point of care for the safe and rapid preparation of platelet-rich plasma (PRP) from a small sample of the patient's blood (up to 60 ml).

    Device Description

    The AutoloGel Process Centrifuge consists of a table-top, non self-decanting, rotor spin centrifuge and processing disposables designed to allow for rapid automatic separation of plasma and red blood cells from a small volume of whole blood. The centrifuge spins at a maximum speed of 7200 rpms producing a maximum force of approximately 4227 g.

    AI/ML Overview

    This is a 510(k) summary for a medical device called the "AutoloGel Process Centrifuge." This document focuses on demonstrating substantial equivalence to previously cleared devices rather than establishing new acceptance criteria or conducting extensive performance studies like those typically seen for AI/ML devices. Therefore, many of the requested fields are not applicable or cannot be extracted from this type of submission.

    Here's a breakdown of the information based on the provided text, with explanations where fields are not applicable:

    1. Table of Acceptance Criteria and Reported Device Performance

    Formal acceptance criteria, as one might see for performance metrics (e.g., sensitivity, specificity for an AI diagnostic), are not presented in this 510(k). The submission focuses on comparing the technological characteristics of the AutoloGel Process Centrifuge to predicate devices. The "performance" reported is inherent in its design specifications and its ability to achieve its intended use, which is to rapidly separate platelet-rich plasma (PRP).

    FeatureAcceptance Criteria (Implied by Predicate Comparison)Reported Device Performance (AutoloGel Process Centrifuge)
    Intended UsePreparation of autologous platelet-rich plasma (PRP) from a small sample of patient's blood (up to 60 ml) at point-of-care.Designed for the safe and rapid preparation of autologous PRP from a small sample of the patient's blood (up to 60 ml) at the patient's point of care.
    Principles of OperationSeparation based on density of liquidsSeparation based on density of liquids
    Table-TopYesYes
    RefrigeratedNoNo
    Micro-Processor ControlledYesYes
    User ProgrammableNo (for similar predicate)No, preset by manufacturer
    Speed ControlPreset (for similar predicate)Preset
    Acceleration and BrakingCurrent-controlledCurrent-controlled
    Maximum RPMComparable to predicate devices (e.g., 6000 RPM, 3400 RPM)7200 RPM
    Maximum RCFComparable to predicate devices (e.g., 3550 g, 2050 g)4227 g
    Tube CapacityVarious internal sizes, maximum 60 mlVarious sizes, maximum 60 ml
    Lid Locking, Lid HoldingYesYes

    2. Sample Size Used for the Test Set and Data Provenance

    Not applicable. This 510(k) is for a general-purpose centrifuge, not an AI/ML device that would typically have a "test set" in the context of performance evaluation. The submission refers to performance data as "not provided" for this section (presumably because it's a mechanical device where performance is demonstrated through engineering specifications and comparison to predicates, not through clinical trials or retrospective data analysis of diagnostic outputs).

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. As this is not an AI/ML diagnostic or predictive device, there is no "ground truth" established by experts in the context of image interpretation or diagnostic accuracy.

    4. Adjudication Method for the Test Set

    Not applicable. No test set requiring adjudication is described.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is not an AI-assisted device for human readers.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is not an algorithmic device.

    7. The Type of Ground Truth Used

    Not applicable. The "ground truth" for a centrifuge relates to its physical performance (e.g., achieving specified RPMs, RCFs, separation efficiency). This is demonstrated through engineering testing and design specifications, not through a "ground truth" methodology as used in AI/ML performance studies.

    8. The Sample Size for the Training Set

    Not applicable. This device is not developed using machine learning, so there is no training set.

    9. How the Ground Truth for the Training Set was Established

    Not applicable. As there is no training set.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1