510(k) Data Aggregation
(181 days)
The Elyra™ TFL System (Laser, Fibers, and Accessories) is intended for incision, excision, resection, ablation, coagulation and hemostasis of soft tissue, with or without an endoscope, in the following indications: urology and lithotripsy.
Urology
- Condylomas
- Urethral strictures
- Lesions of external genitalia
- Bladder neck incisions (BNI)
- Ablation and resection of bladder tumors, urethral tumors, and ureteral tumors
- Endoscopic fragmentation of urethral, ureteral, bladder, and renal calculi
- Treatment of distal impacted fragments remaining in the ureters following lithotripsy
Lithotripsy and Percutaneous Urinary Lithotripsy
- Endoscopic fragmentation of urethral, ureteral, bladder and renal calculi including cystine, calcium oxalate monohydrate, and calcium oxalate dihydrate stones
- Endoscopic fragmentation of calculi
- Treatment of distal impacted fragments of steinstrasse when guidewire cannot be passed
Elyra™ Plus Thulium Fiber Laser System
The Elyra™ Plus TFL System (Laser, Fibers, and Accessories) is intended for incision, excision, resection, ablation, coagulation, hemostasis, and vaporization of soft tissue, with or without an endoscope, in the following indications: urology and lithotripsy.
Urology
- Ablation of Benign Prostatic Hyperplasia (Hypertrophy) [BPH]
- Laser Resection of the Prostrate (LRP)
- Laser Enucleation of the Prostate (LEP)
- Laser Ablation of the Prostate (LAP)
- Transurethral Incision of the Prostate (TUIP)
- Condylomas
- Urethral strictures
- Lesions of external genitalia
- Bladder neck incisions (BNI)
- Ablation and resection of bladder tumors, urethral tumors, and ureteral tumors
- Endoscopic fragmentation of urethral, ureteral, bladder, and renal calculi
- Treatment of distal impacted fragments remaining in the ureters following lithotripsy
Lithotripsy and Percutaneous Urinary Lithotripsy Indications
- Endoscopic fragmentation of urethral, ureteral, bladder and renal calculi including cystine, calcium oxalate monohydrate, and calcium oxalate dihydrate stones
- Endoscopic fragmentation of calculi
- Treatment of distal impacted fragments of steinstrasse when guidewire cannot be passed
The Elyra™ Thulium Fiber Laser (TFL) System (Elyra™ Plus, Elyra™, Elyra™ Thulium Laser Fibers and Accessories) is a thulium fiber laser which delivers a pulsed beam of near-infrared light (1940nm) through the active media of a single use or reusable delivery fiber. The system is contained in a mobile format and has an articulating graphical user interface display and built-in laser generator with the ability to connect to standard mains power.
The Elyra™ TFL System is available in two models: the Elyra™ TFL System and the Elyra™ Plus TFL System. The lasers are similar devices with only the following differences:
- maximum average power output
- frequency
- pulse duration
- pulse energy
- maximum peak power
- foot pedal options to activate energy delivery
- vaporization and BPH indications
The Elyra™ TFL System and Elyra™ Plus TFL System includes a medical laser generator (which includes a blast shield, remote interlock connector, keys, and power cord), delivery fibers, and a footswitch (hybrid or wired). Safety goggles are provided with each system.
The delivery fibers are available in standard tip and ball tip options as single use devices. Reusable fibers are only available in the standard tip option. Each fiber contains a unique radio frequency identification (RFID) tag that will allow the laser generator to identify certain aspects of the fiber, including UDI, catalog number, lot number, manufacture date, expiration date, size, max power and energy, and number of remaining uses (if applicable information once attached). Fibers are only compatible with Elyra™ systems.
N/A
Ask a specific question about this device
(251 days)
The BD Rubber Utility Catheter is indicated for intermittent catheterization of the urethra to drain urine from the bladder by patients who are not capable of voluntary urination.
The BD Rubber Utility Catheter is an uncoated, latex, intermittent urethral catheter that is provided sterile and intended for single use. It is intended for the drainage of urine from the bladder via intermittent urethral catheterization. The device is intended for use in adult and pediatric patients 2 years of age or older. Selection of the appropriate catheter size should be determined by the patient's healthcare provider based on clinical judgement.
N/A
Ask a specific question about this device
(50 days)
The Aspirex™ Thrombectomy System is indicated for the removal of acute emboli and thrombi from vessels of the peripheral venous system.
The 6F and 8F Aspirex™ Thrombectomy Systems are indicated for the removal of acute emboli and thrombi from hemodialysis access grafts and native arteriovenous fistulas.
The Aspirex™ Thrombectomy System-composed of the Aspirex™ Thrombectomy Catheter Set and the Drive System-is designed for efficient thrombus removal with strong, continuous, and controlled aspiration. The Drive System is composed of the control unit, a motor, and a footswitch. The Drive System is small and portable, and designed for simple, quick set up and ease of use.
The Aspirex™ Thrombectomy Catheter Set is composed of multiple components, including the Aspirex™ Thrombectomy Catheter, the Aspirex™ Guidewire, collecting bag, and sterile drape. The Aspirex™ Thrombectomy Catheter consists of a braided shaft, to add strength and torque, through which runs a helix. The catheter shaft connects to a metallic head constructed with a side window(s) at the distal end. The head has a smooth, rounded, atraumatic shape so unintentional contact with the vessel wall will not cause damage to the vessel. Contact with the vessel wall is not necessary for the catheter to exert its effect. An ergonomic handle, connected to the catheter shaft at the proximal end, connects to the motorized Drive System via a magnetic clutch. The entire catheter tracks over the Aspirex™ Guidewire previously navigated across the thrombus/embolus.
The provided text is a 510(k) summary for the Aspirex™ Thrombectomy System. This document focuses on demonstrating substantial equivalence to a predicate device, not on proving a device meets specific acceptance criteria through a study with predefined performance metrics like those typically found in an AI/ML context.
Therefore, many of the requested items (e.g., acceptance criteria table, sample sizes, expert ground truth establishment, MRMC studies, standalone performance, training set details) are not applicable or not provided in this type of FDA submission for a medical device that processes human biological material.
However, I can extract information related to the device, its intended use, and the performance data that was reviewed (rather than generated by a specific study to meet acceptance criteria).
Here's what can be extracted and what cannot:
1. A table of acceptance criteria and the reported device performance:
- Not Applicable/Not Provided: This document does not present a table of specific acceptance criteria (e.g., target specificity, sensitivity, or image quality metrics) or reported device performance against those criteria in the way an AI/ML device would. Instead, it discusses the device's functional specifications and clinical outcomes in terms of existing literature and clinical study reports.
Here's information related to the device specifications that might be considered "performance" in a mechanical sense, but not quantitative "acceptance criteria" for an AI/ML model:
| Metric | Catheter Size (6F) | Catheter Size (8F) | Catheter Size (10F) |
|---|---|---|---|
| Minimum Vessel Diameter | 3 mm | 5 mm | 8 mm |
| Catheter External Diameter | 2.0 mm | 2.7 mm | 3.3 mm |
| Nominal Rotation (RPM) | 60,000 | 40,000 | 40,000 |
| Maximum Aspiration (ml/min) | 45 | 75 | 130 |
2. Sample sizes used for the test set and the data provenance:
- Not Provided: The document states that a "review of clinical data from scientific literature and clinical study reports" was performed. It does not specify a "test set" sample size, as it's a review of existing data, not a new, controlled study to validate a new claim against a test set.
- Data Provenance: The data provenance is "scientific literature and clinical study reports." The country of origin and whether it was retrospective or prospective is not specified.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- Not Applicable/Not Provided: This is not a study involving expert readers establishing ground truth for a diagnostic AI/ML device. The "performance data" is derived from a review of clinical outcomes reported in existing literature and studies, which reflects real-world clinical results, not expert "ground truth" for a device's diagnostic performance.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:
- Not Applicable/Not Provided: No adjudication method is mentioned as this is not a study comparing human performance or diagnostic accuracy.
5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
- Not Applicable/Not Provided: This is a physical medical device (thrombectomy system), not an AI/ML diagnostic aid. Therefore, an MRMC study and effects on human reader performance are irrelevant.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
- Not Applicable/None: This is a physical medical device (thrombectomy system) that is used by humans, not an algorithm.
7. The type of ground truth used:
- Clinical Outcomes/Patency Rates: The "performance data" relied on reviewing "primary patency rates" in hemodialysis access grafts and native arteriovenous fistulas. This is long-term clinical outcome data, not a diagnostic "ground truth" established by experts or pathology for a specific event.
8. The sample size for the training set:
- Not Applicable/Not Provided: This is not an AI/ML device, so there is no "training set." The device's design and manufacturing are identical to the predicate.
9. How the ground truth for the training set was established:
- Not Applicable/Not Provided: No training set exists for this type of device.
Summary of Device Performance (from the document):
The performance data reviewed for the Aspirex™ Thrombectomy System focused on:
- Type of data: Clinical data from scientific literature and clinical study reports.
- Focus: Device performance and clinical outcomes of percutaneous mechanical thrombectomy with the Aspirex™ Thrombectomy System for the removal of occlusions from hemodialysis access grafts and native arteriovenous fistulas.
- Key Metric Analyzed: Primary patency rates.
- Conclusion: Vascular access patency rates after treatment with the Aspirex™ device are similar to those observed with treatment with other mechanical thrombectomy devices or surgery. Sub-group analyses confirmed these results. The review concluded that the use of the Aspirex™ Thrombectomy System in these expanded indications "does not raise new questions of safety and effectiveness" and "provides satisfactory clinical outcomes in terms of patency rates and the functioning of hemodialysis vascular access."
Ask a specific question about this device
(101 days)
The Highlander™ 014 PTA Balloon Dilatation Catheted for use in percutaneous transluminal angioplasty (PTA) of the peripheral vasculature, including femoral, popliteal and renal arteries. This device is also indicated for post-dilatation of balloon expanding stents in the peripheral vasculature. This catheter is not for use in coronary arteries.
The Highlander™ 014 PTA Balloon Dilatation Catheter is a small vessel balloon catheter consisting of an over the wire catheter with a balloon fixed at the distal tip. The proprietary non-compliant, low-profile balloon is designed to provide consistent balloon diameters and lengths even at high pressures. For all balloon lengths, radiopaque markers delineate the working length of the balloon and aid in balloon placement. For balloon lengths of 100mm and greater, two radiopague markers are positioned on the distal portion of the balloon and one radiopaque marker is positioned on the proximal portion of the balloon to differentiate between the distal and proximal ends of the balloon. The catheters include an atraumatic tip to facilitate advancement of the catheter to and through the stenosis. A silicone-based, hydrophobic coating is present on the distal segment of the shaft and balloon. Highlander™ 014 is compatible with 0.014" guidewires. The proximal portion of the catheters include a female luer lock hub connected to the inflation lumen, and a female luer lock hub connected to the guidewire lumen.
Packaged with every product is a profile reducing sheath that is positioned over the balloon for protection before use. A stylet is placed into the tip of the catheter to aid in rewrap/refolding of the balloon. These products are not made with natural rubber latex.
The GeoAlign™ Marking System is a non-radiopaque ruler on the catheter shaft measured from the distal tip. The GeoAlign™ markings are designated on the catheter shaft by 1cm increment bands with an accuracy within ±1mm. The distance from the distal catheter tip is labeled in 10cm increments. Thicker bands denote the midway point (5cm) between the labeled distances. The GeoAlign™ Marking System is designed to be used as a tool to externally measure the intravascular advancement and/or retraction of the catheter. This can provide an intravascular reference regarding the location of the distal tip of the catheter or an approximate intravascular length measurement between two points. The GeoAlign™ Marking System may also facilitate geographic alignment of an adjunctive therapy that includes the same GeoAlign™ Marking System.
The provided text is a 510(k) summary for the Highlander™ 014 PTA Balloon Dilatation Catheter. This document details the device's characteristics, indications for use, and a comparison to a predicate device to demonstrate substantial equivalence. It is important to note that this document does not contain information about studies related to AI/ML device performance, ground truth establishment, or expert reviews as it is for a physical medical device (balloon catheter).
Therefore, this response will focus on the acceptance criteria and performance data for the physical device as described in the provided text.
1. Table of Acceptance Criteria and Reported Device Performance
The document lists various in vitro tests performed to demonstrate substantial equivalence. It does not provide specific numerical acceptance criteria or detailed quantitative performance results for each test. Instead, it states a general conclusion for each category: "The results from these tests demonstrate that the technological characteristics and performance criteria of the Highlander™ 014 PTA Balloon Dilatation Catheter are substantially equivalent to the predicate device, and that it can perform in a manner equivalent to devices currently on the market for the same intended use." and "met all predetermined acceptance criteria of design verification and validation as specified by applicable standards, guidance, test protocols and/or customer inputs."
However, based on the categories of tests listed, a general representation of acceptance criteria and reported performance is as follows:
| Test Category | Acceptance Criteria (Implicit from "met all predetermined acceptance criteria") | Reported Device Performance |
|---|---|---|
| Physical Dimensions | Conformity to specified dimensions (Catheter Length, Tip Length, Balloon Working Length, Balloon OD at OP, Shaft Outer Diameter, Coating Length) | Met all predetermined acceptance criteria for design verification and validation, demonstrating substantial equivalence to the predicate device. |
| Mechanical Performance | Acceptable limits for Marker Band Alignment, Balloon Rated Burst Pressure, Leak, & Burst Mode, Burst in Stent, Crossing Profile, Distensibility, Luer Lock Compatibility, Fatigue, Fatigue in Stent, Hub to Shaft Tensile, Shaft Inner Diameter/Guidewire Compatibility, Inflation, Deflation, Balloon to Shaft Tensile, Tip Tensile, Catheter Elongation, Trackability, Reinsertion, Kink Resistance, Torque Response, Flushability | Met all predetermined acceptance criteria for design verification and validation, demonstrating substantial equivalence to the predicate device. |
| Material Characteristics | Acceptable limits for Particulate matter, Coating Integrity, Visual Inspection (e.g., absence of defects) | Met all predetermined acceptance criteria for design verification and validation, demonstrating substantial equivalence to the predicate device. |
| Labeling/Marking | Accuracy and durability of GeoAlign™ Marking Position, GeoAlign™ Marking Durability, GeoAlign™ Marking Legibility | Met all predetermined acceptance criteria for design verification and validation, demonstrating substantial equivalence to the predicate device. |
| Packaging Integrity | Acceptable performance for Packaging Integrity Visual Inspection, Bubble Emission Leak, Pouch Seal Strength, Heat Seal Visual Inspection | Met all predetermined acceptance criteria for design verification and validation, demonstrating substantial equivalence to the predicate device. |
| Biocompatibility | Conformance to biocompatibility standards (Cytotoxicity, Sensitization, Intracutaneous Reactivity, Acute Systemic Toxicity, Material Mediated Pyrogenicity, Hemocompatibility) | Met all predetermined acceptance criteria for design verification and validation, demonstrating substantial equivalence to the predicate device. The device is not made with natural rubber latex. |
2. Sample Size for the Test Set and Data Provenance
The document does not specify the sample sizes used for each in vitro test. The tests are "in vitro" (performed in a lab setting, not on human or animal subjects). Therefore, there is no data provenance in terms of country of origin or retrospective/prospective nature as would be relevant for clinical studies.
3. Number of Experts and Qualifications
This information is not applicable. The evaluations described are in vitro engineering and materials tests, not clinical studies requiring expert interpretation of diagnostic images or patient outcomes.
4. Adjudication Method
This information is not applicable as there is no mention of a ground truth needing adjudication by human experts in the context of this device's testing.
5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study
No. This type of study is typically performed for AI-driven diagnostic imaging devices to assess the impact of AI assistance on human reader performance. The Highlander™ 014 PTA Balloon Dilatation Catheter is a physical medical device, not an AI/ML diagnostic tool.
6. Standalone Performance Study
Yes, the in vitro tests conducted on the Highlander™ 014 PTA Balloon Dilatation Catheter can be considered a standalone performance study. These tests evaluated the device's physical and mechanical properties and biocompatibility independent of human use in a clinical setting. The conclusion states that "The subject device, the Highlander™ 014 PTA Balloon Dilatation Catheter, met all predetermined acceptance criteria of design verification and validation as specified by applicable standards, guidance, test protocols and/or customer inputs." This indicates a standalone assessment of its performance against established benchmarks.
7. Type of Ground Truth Used
The "ground truth" for the in vitro tests would be defined by the technical specifications, industry standards, relevant FDA guidance documents, and internal risk assessment procedures. For example, for physical dimensions, the ground truth is the specified design dimension; for burst pressure, it's the minimum acceptable pressure according to device-specific or industry standards. For biocompatibility tests, the ground truth is the pass/fail criteria established by recognized international standards (e.g., ISO 10993 series).
8. Sample Size for the Training Set
This information is not applicable. The described tests are for a physical medical device and do not involve AI/ML algorithms that require training data.
9. How the Ground Truth for the Training Set was Established
This information is not applicable for the reasons stated in point 8.
Ask a specific question about this device
(31 days)
The WavelinQ™ Generator is used to deliver RF energy via an assortment of surgical devices to cut and coagulate different kinds of tissue.
The WavelinQ™ Generator is a high frequency isolated generator that utilizes electrical current to deliver radiofrequency (RF) energy to the catheter electrode for formation of a vascular fistula. The generator offers a receptacle for a monopolar handpiece. The WavelinQ™ Generator is intended to be used with the currently marketed and cleared device WavelinQ™ EndoAVF System (K192239). The generator has one setting (AV1) equivalent to the mode (Cut T, 60W, 0.7s) of the predicate device, ESU-1 Electrosurgical Generator, that is used during the WavelinQ™ EndoAVF System procedure. This mode is set to deliver energy at 60 Watts for 0.7 seconds. The generator has a return electrode contact, for use with a split ground pad, and quality monitoring system (NEM) to reduce the risk of patient burns at the return electrode site. The pad-sensing feature allows the user to use only a split return electrode, also referred to as a split ground pad.
The device consists of a generator and power cord and is packaged with a User's Guide in a cardboard shipping box with protective foam inserts. The main device components are a front panel containing the power button, LED numeric display, alarm and return electrode indicator lights, and connector ports for accessories, a back panel consisting of volume controls, a power cord outlet and fuse, and internal components (printed circuit boards, speakers, cabling).
The provided text is a 510(k) Summary for a medical device (WavelinQ™ Generator) and does not contain information about an AI/ML-based device. Therefore, it is not possible to describe acceptance criteria, a study proving device performance, or details regarding AI/ML ground truth, expert opinions, or MRMC studies, as none of that information is applicable to this document.
The document discusses the substantial equivalence of the WavelinQ™ Generator to a predicate device based on its intended use, indications for use, technological characteristics, and performance testing for electrical safety, mechanical aspects, reliability, and functionality. The tests performed are standard for electro-surgical devices and do not involve AI/ML components or human interpretation of outputs that would require multi-reader studies or complex ground truth establishment for AI model evaluation.
Ask a specific question about this device
(141 days)
The Aspirex™ Thrombectomy System is indicated for the removal of acute emboli and thrombi from vessels of the peripheral venous system.
The Aspirex™ Thrombectomy System-composed of the Aspirex™ Thrombectomy Catheter Set and the Drive System-is designed for efficient thrombus removal with strong, continuous, and controlled aspiration The Drive System is composed of the control unit, a motor, and a footswitch. The Drive System is small and portable, and designed for simple, quick set up and ease of use.
The Aspirex™ Thrombectomy Catheter Set is composed of multiple components, including the Aspirex™ Thrombectomy Catheter, the Aspirex™ Guidewire, collecting bag, and sterile drape. The Aspirex™ Thrombectomy Catheter consists of a braided shaft, to add strength and torque, through which runs a helix. The catheter shaft connects to a metallic head constructed with a side window(s) at the distal end. The head has a smooth, rounded, atraumatic shape so unintentional contact with the vessel wall will not cause to the vessel. Contact with the vessel wall is not necessary for the catheter to exert its effect. An ergonomic handle, connected to the catheter shaft at the proximal end, connects to the motorized Drive System via a magnetic clutch. The entire catheter tracks over the Aspirex™ Guidewire previously navigated across the thrombus/embolus.
The Aspirex™ Guidewire has a LubriSkin PTFE-coated nitinol core wire with a gold-plated tungsten tip coated with DSM ComfortCoat® hydrophilic coating. The guidewire is used to initially cross through the area to be treated.
The provided text describes a medical device, the Aspirex™ Thrombectomy System, and its performance data to demonstrate substantial equivalence to a predicate device. However, it does not contain information about acceptance criteria or a study related to an AI/algorithm-based device's performance, human reader assistance, or ground truth establishment for such a device.
The study described is a GLP animal study comparing the Aspirex™ catheter (test article) to the Indigo Aspiration Catheter (control article) in healthy veins. This study assesses the physical and biological performance of the catheters, not an AI algorithm.
Therefore, I cannot provide the requested information regarding AI device acceptance criteria and performance based on the input text. The text does not discuss:
- A table of acceptance criteria and the reported device performance for an AI/algorithm.
- Sample size for a test set (related to AI data) or data provenance.
- Number of experts or their qualifications for establishing ground truth for AI data.
- Adjudication method for an AI test set.
- Multi-reader multi-case (MRMC) comparative effectiveness study for AI assistance.
- Standalone performance of an AI algorithm.
- Type of ground truth used for AI (e.g., expert consensus, pathology, outcomes data).
- Sample size for a training set for an AI algorithm.
- How ground truth for a training set for an AI algorithm was established.
The document focuses on the mechanical and biological performance of a physical medical device (thrombectomy system) through in vitro and animal studies, and its substantial equivalence to a predicate device, as required for FDA 510(k) clearance.
Ask a specific question about this device
(261 days)
The Conquest™ 40 PTA Dilatation Catheter is recommended for use in Percutaneous Transluminal Angioplasty of the femoral, iliac, and renal arteries and for the treatment of native or synthetic arteriovenous dialysis fistulae. This device is also recommended for post-dilatation of stents in the peripheral vasculature. This catheter is not for use in coronary arteries.
The Atlas™ Gold PTA Dilation Catheter is indicated for use in Percutaneous Transluminal Angioplasty of the peripheral vasculature, including the illac and femoral veins, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for post-dilatation of stents and stent grafts in the peripheral vasculature. This catheter is not for use in coronary arteries.
The Vida™ PTV Dilatation Cather is recommended for Percutaneous Transluminal Valvuloplasty (PTV) of the pulmonary valve in the following:
· A patient with isolated pulmonary valve stenosis.
· A patient with valvular pulmonary stenosis with other minor congenital heart disease that does not require surgical intervention.
The Vida™ BAV Balloon Valvuloplasty Catheter is indicated for balloon aortic valvuloplasty.
The Conquest™ 40 PTA Dilatation Catheter is a high-performance balloon catheter consisting of an over-the-wire catheter with a balloon fixed at the distal tip. The proprietary ultra non-compliant, low profile balloon is designed to provide consistent balloon diameters and lengths even at high pressures. Two radiopaque markers delineate the working length of the balloon and aid in balloon placement. The coaxial catheter includes a tapered atraumatic tip to facilitate advancement of the catheter to and through the stenosis. The proximal portion of the catheter includes a female luer lock hub connected to the inflation lumen, and a female luer-lock hub connected to the quidewire lumen. The over-the-wire catheter is compatible with 0.035" guidewires and is available in 50cm and 75cm working lengths. Packaged with every product is a profile reducing sheath that is positioned over the balloon for protection before use. A re-wrapping tool is also provided on the catheter shaft. A stylet is placed into the tip of the catheter to aid in re-wrap/refolding of the balloon. This product is not manufactured with any latex.
The Atlas™ Gold PTA Dilatation Catheter is a high-performance balloon catheter consisting of an over-the-wire catheter with a balloon fixed at the distal tip. The proprietary non-compliant, low profile balloon is designed to provide consistent balloon diameters and lengths even at high pressures. Two radiopaque markers delineate the working length of the balloon and aid in balloon placement. The coaxial catheter includes a tapered atraumatic tip to facilitate advancement of the catheter to and through the stenosis. The proximal portion of the catheter includes a female luer lock hub connected to the inflation lumen, and a female luer-lock hub connected to the guidewire lumen. The over-the-wire catheter is compatible with .035" guidewire and is available in 80 cm and 120 cm working lengths.
Packaged with every product is a profile reducing sheath that is positioned over the balloon for protection before use. A re-wrapping tool is also provided on the catheter shaft to aid in re-wrap/refolding of the balloon. This product is not manufactured with any natural rubber latex.
The Vida™ PTV Dilatation Catheter is a high-performance balloon catheter consisting of an over-the-wire catheter with a balloon fixed at the distal tip. The proprietary, noncompliant, low profile balloon is designed to provide consistent balloon diameters and lengths even at high pressures. Two radiopaque markers delineate the working length of the balloon and aid in balloon placement. The coaxial catheter includes an atraumatic tip to facilitate advancement of the catheter to and through the valve. The over-the-wire catheter is compatible with .035" guidewire and is available in 100 cm working length. The proximal portion of the catheter includes a female luer-lock hub connected to the inflation lumen, and a female luer-lock hub connected to the guidewire lumen.
Packaged with every product is a profile reducing sheath that is positioned over the balloon for protection before use. A re-wrapping tool is also provided on the catheter shaft. This product is not manufactured with any latex.
The Vida™ BAV Balloon Valvuloplasty Catheter is a high-performance balloon catheter consisting of an over-the-wire catheter with a balloon fixed at the distal tip. The proprietary, non-compliant, low profile balloon is designed to provide consistent balloon diameters and lengths. Two radiopaque markers delineate the working length of the balloon and aid in balloon placement. The coaxial catheter includes an atraumatic tip to facilitate advancement of the catheter to and through the valve. The over-the-wire catheter is compatible with .035" guidewire and is available in 100 cm working length. The proximal portion of the catheter includes a female luer-lock hub connected to the inflation lumen, and a female luer-lock hub connected to the guidewire lumen.
Packaged with every product is a profile reducing sheath that is positioned over the balloon for protection before use. A re-wrapping tool is also provided on the catheter shaft. This product is not manufactured with any latex.
The provided document describes the substantial equivalence determination for several medical devices, specifically balloon dilatation and valvuloplasty catheters. It does not present acceptance criteria or performance data for an AI/ML-driven medical device. Instead, it focuses on the engineering and material characteristics of physical medical devices and their comparison to previously cleared predicate devices.
Therefore, I cannot provide a response based on the requirements of your prompt, as the document does not contain information related to:
- AI/ML performance testing: The document details physical device performance tests (e.g., trackability, burst strength, fatigue, biocompatibility), not AI model performance metrics like sensitivity, specificity, or AUC.
- Test/training sets for AI/ML: There is no mention of data sets, sample sizes for AI training or testing, data provenance, or ground truth establishment relevant to an AI algorithm.
- Expert adjudication or MRMC studies: These are concepts specific to the evaluation of AI systems, typically involving human readers or experts, which are not applicable to the physical devices described in this submission.
The document states: "The subject devices...met all predetermined acceptance criteria of design verification and validation as specified by applicable standards, guidance, test protocols and/or customer inputs." However, it does not specify what those "predetermined acceptance criteria" are for each test, nor does it present the reported device performance in detail (e.g., actual burst pressures achieved vs. minimum required). It lists the types of tests performed.
To fulfill your request, the input document would need to describe the development and validation of an AI/ML component, including its specific acceptance criteria and the results of studies demonstrating its performance.
Ask a specific question about this device
(99 days)
The Rotarex™ Atherectomy System is intended for use as an atherectomy device and to break up and remove thrombus from native peripheral arteries or peripheral arteries fitted with stents, stent grafts or native or artificial bypasses.
The Rotarex™ Atherectomy System is made up of a single use Rotarex™ Atherectomy Catheter Set and the Drive System, consisting of the control unit, motor and foot switch. The Rotarex™ Atherectomy Catheter Set is composed of multiple components, including the Rotarex™ Atherectomy Catheter, guidewire, collecting bag, and sterile drape. Rotarex™ Atherectomy Catheters are over-the-wire, single use, percutaneous devices for the removal of atheromatic plaque and thrombi in native arteries fitted with stents, stent grafts or native or artificial bypasses. The catheters are latex and phthalate free, and consist of a flexible outer covering, a rotating head, and a rotating helix which runs the length of the catheter. A lumen for the passage of the supplied guidewire runs the entire length of the helix and through the head of the catheter. The catheter head is made up of two overlying metal cylinders, with two side openings. The outer cylinder is connected to the rotating helix, and the inner cylinder to the catheter shaft. The helix and the catheter head rotate at approximately 40,000-60,000 rpm depending on the model, by means of a gear box in the catheter housing and a motor contained within the catheter handle driven by the Drive System. The rotating outer cylinder is fitted with abrading facets at its foremost tip. The Rotarex™ Atherectomy System Guidewires are 0.018" and are included with each Rotarex™ Atherectomy Catheter Set. These guidewires consist of a Nitinol core and a PTFE coating with a 9.5cm hydrophilic distal coating and a 4 cm angled flex tip. All components within the Rotarex™ Atherectomy Catheter Sets are supplied sterile for single use only. The method of sterilization is ethylene oxide.
This document is a 510(k) Summary for the Rotarex™ Atherectomy System. It describes the device, its intended use, comparison to predicate devices, and performance data used to demonstrate substantial equivalence.
Here's the breakdown of the requested information based on the provided text:
1. A table of acceptance criteria and the reported device performance
The document does not provide a specific table of quantitative acceptance criteria with corresponding performance metrics. Instead, it states overall conclusions:
| Acceptance Criteria (Stated Purpose) | Reported Device Performance (Conclusion) |
|---|---|
| Substantial Equivalence | The results from both in vitro studies and clinical literature demonstrate that the technological characteristics and performance criteria of the subject Rotarex™ Atherectomy System are substantially equivalent to the predicate device, and that it can perform in a manner equivalent to devices currently on the market for the same intended use. |
| Predetermined Acceptance Criteria | The subject device, the Rotarex™ Atherectomy System, met all predetermined acceptance criteria of design verification and validation as specified by applicable standards, guidance, test protocols and/or customer inputs. Rotarex™ Atherectomy System is substantially equivalent to the legally marketed predicate device, the Rotarex® S catheter. |
| Safety and Effectiveness | The removal of certain contraindications (re-stated as warnings or supported by data) does not affect the safety and effectiveness of the device when used as labeled. |
2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
The document mentions "in vitro tests" and "Clinical Literature Review."
- In vitro tests:
- Sample size: Not specified.
- Data provenance: Not specified, but generally in vitro tests are laboratory-controlled and do not have country of origin in the same way clinical data does. The tests were performed "using FDA Guidance Documents on non-clinical testing of medical devices and internal Risk Assessment procedures."
- Clinical Literature Review:
- Sample size: Not specified, as it's a review of existing literature, not a new study with a defined sample size. It refers to "a significant body of medical literature."
- Data provenance: Not specified in terms of country of origin or retrospective/prospective nature. Clinical literature usually encompasses both retrospective analyses and prospective studies from various global locations.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
This information is not provided in the document. The document describes a literature review and in vitro testing, neither of which typically involves experts establishing ground truth for a test set in the way an AI algorithm test might.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
This information is not provided in the document. The document describes laboratory testing and a literature review, not a study that would involve expert adjudication of a test set.
5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
No, a multi-reader multi-case (MRMC) comparative effectiveness study was not explicitly mentioned or described. This document focuses on demonstrating substantial equivalence of a physical medical device (atherectomy system), not a diagnostic AI tool. The "clinical literature" review examined the safety and efficacy of the device itself compared to other treatments, not the improvement of human readers with AI assistance.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
This question is not applicable as the Rotarex™ Atherectomy System is a physical interventional medical device, not an AI algorithm. Therefore, no standalone algorithm performance was assessed.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)
- For in vitro tests: The "ground truth" would be established by the physical and chemical properties of the materials tested, the design specifications, and the quantifiable outcomes of the specific tests (e.g., heat generation measurements, absence of emboli in collected fluid).
- For Clinical Literature Review: The "ground truth" comes from the aggregated findings of published clinical studies, which typically rely on clinical outcomes data (e.g., patency rates, complication rates, re-intervention rates) and potentially expert diagnoses within those studies.
8. The sample size for the training set
This information is not applicable. The Rotarex™ Atherectomy System is a physical medical device, not an AI algorithm that requires a training set.
9. How the ground truth for the training set was established
This information is not applicable, as it's not an AI algorithm with a training set.
Ask a specific question about this device
(269 days)
The BD Recanalization System (console and footswitch) and Crosser iQ™ Ultrasonic CTO Device are indicated to facilitate the intra-luminal placement of conventional guidewires beyond peripheral artery chronic total occlusions.
Crosser iQ™ Ultrasonic CTO Device: The Crosser iQ™ Ultrasonic CTO Device is intended for use only with the BD Recanalization System (console and footswitch).
BD Recanalization System: The BD Recanalization System (console and footswitch) is intended for use only with the Crosser iQTM Ultrasonic CTO Crossing Device.
The BD Recanalization System (Console and Footswitch) includes a non-sterile, reusable console with an integrated roller pump and user interface, as well as a footswitch. The footswitch can be used as an alternative to the hand-controlled activation of the Crosser iQ™ Ultrasonic CTO Device. The console delivers ultrasonic energy to the Crosser iQ™ Ultrasonic CTO Device. The console is comprised of a molded outer housing and internal structural components to support and protect the electro-mechanical components, including the internal generator. The user interface includes an LCD screen to display images for guiding system preparation and use. The back of the console includes an AC power control switch and clamp assembly to allow the user to secure the console to an IV pole before the procedure and remove after, if desired. The roller pump delivers sterile saline for irrigation from a saline bag through the Crosser iQ™ Ultrasonic CTO Device saline tubing to the tip of the crossing catheter. The saline bag is not included with the BD Recanalization System. In addition to initial package labeling is present on both the front and back of the console to aid the user in identifying console interface features.
The Crosser iQ™ Ultrasonic CTO Device is a single use crossing catheter, consisting of a catheter assembly, handle, power cord, and saline tubing with spike set. The Crosser iQ™ Ultrasonic CTO Device is connected to the console via the power cord, through which AC power is converted into high frequency ultrasonic mechanical vibrations to the tip by a transducer within the Crosser iQ™ CTO Device handle. The Crosser iQ™ Ultrasonic CTO Device includes the GeoAlign™ Marking System along the working length of the catheter assembly, with a hydrophilic coating over the distal portion of the working length. The GeoAlign™ Marking System is a non-radiopaque ruler on the catheter shaft measured from the distal tip. The GeoAlign™ markings are designated on the catheter shaft by 1 cm increment bands with an accuracy within ± 1 mm. The distance from the distal catheter tip is labeled in 10 cm increments. Thicker bands denote the midway point (5 cm) between the labeled distances. The GeoAlign™ Marking System is designed to be used as a tool to externally measure the intravascular advancement and/or retraction of the catheter. This can provide an intravascular reference reqarding the location of the distal tip of the catheter or an approximate intravascular length measurement between two points. The GeoAlign™ Marking System may also facilitate geographic alignment of an adjunctive therapy that includes the same GeoAlign™ Marking System. The GeoAlign™ Marking System provides an approximation that may not be an exact representation of the actual distance traveled intravascularly and should be confirmed under fluoroscopy. The GeoAlign™ Marking System includes non-radiopaque white markings and are designed to be utilized outside the sheath.
The provided text describes the Crosser iQ™ CTO Recanalization System and its performance data to demonstrate substantial equivalence to a predicate device. It includes information on a summative usability study and an animal study.
Here's the extracted information based on your request:
1. A table of acceptance criteria and the reported device performance
The document does not provide a specific table of discrete acceptance criteria with numerical performance metrics for the summative usability study or the animal study. Instead, it states high-level conclusions:
| Study | Acceptance Criteria (as described) | Reported Device Performance |
|---|---|---|
| Summative Usability Study | Safety outcomes for the subject device when used by the intended users in the intended use environment. | "Acceptance criteria for the study were met, and the results demonstrate substantially equivalent safety outcomes for the subject device when used by the intended users in the intended use environment." |
| Animal Study | Animal health, tissue response, and device usability. | "Success criteria were met for animal health, tissue response, and device usability." |
| Overall Conclusion (In vitro and Animal) | Predetermined acceptance criteria of design verification and validation as specified by applicable standards, guidance, test protocols and/or customer inputs. | "The Crosser iQ™ CTO Recanalization System met all predetermined acceptance criteria of design verification and validation... The Crosser iQ™ CTO Recanalization System is substantially equivalent to the legally marketed predicate device." |
2. Sample sized used for the test set and the data provenance
-
Summative Usability Study:
- Sample Size: 15 physicians and 15 technologists (total 30 participants).
- Data Provenance: Not explicitly stated, but implies a simulated environment given the description of "simulated CTO procedure."
-
Animal Study:
- Sample Size: 9 animals (non-diseased porcine, with each animal receiving six individual/non-overlapping treatments).
- Data Provenance: Not explicitly stated, but implies laboratory setting for a GLP animal study.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
- Summative Usability Study: The "participants" (15 physicians and 15 technologists) were the users being evaluated, not establishing ground truth. The study assessed their use of the device. Qualifications are implicitly "physicians" and "technologists."
- Animal Study: The document mentions "necropsy for gross examination" and "histological analysis" by unspecified personnel, but does not detail "experts" establishing ground truth in the way one might for diagnostic AI. The "ground truth" here is the biological/physiological response observed and assessed by the study's protocol and investigators.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
Not explicitly mentioned for either study.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
There is no mention of a multi-reader multi-case (MRMC) comparative effectiveness study, nor any evaluation of human readers improving with AI assistance. This device is a physical medical device (catheter system), not an AI-powered diagnostic tool.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
This question is not applicable. The device is a physical medical device, not an algorithm. Its performance is inherent in its physical and mechanical operation, guided by human operators.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
- Summative Usability Study: The "ground truth" was likely defined by the success or failure of participants to complete tasks as outlined in the Instructions for Use (IFU) and the evaluation of safety outcomes, likely assessed by observers/evaluators of the study.
- Animal Study: The "ground truth" was established through direct observation during the study, gross examination at necropsy, and histological analysis of tissues.
8. The sample size for the training set
This question is not applicable. The device is a physical medical device. There is no "training set" in the context of machine learning or AI algorithms.
9. How the ground truth for the training set was established
This question is not applicable. There is no training set for this type of device.
Ask a specific question about this device
(206 days)
The GlidePath™ Retro Long-Term Hemodialysis Catheters are indicated for use in attaining short-term or long-term vascular access for hemodialysis, hemoperfusion or apheresis therapy. Access is attained via the internal jugular vein, subclavian vein, or femoral vein. Catheters longer than 40 cm are intended for femoral vein insertion.
The GlidePath™ Retro Long-Term Hemodialysis Catheter features a dual-lumen polyurethane catheter shaft with optimized double-D cross-sectional design providing separate arterial and venous lumens, an external bifurcation hub with SwiftClick connector assembled by physician upon placement, and arterial and venous extension legs that connect to an external dialysis machine or blood cleansing device. The arterial (red) luer connector secures to the blood intake on the dialysis machine and the venous (blue) luer connector secures to the blood return line on the dialysis machine. Each extension leg has an atraumatic occlusion clamp which closes access to the lumen. The symmetrical catheter tip contains holes that aid in the distribution of blood flow or aid in over-the-guidewire placement. The dialysis catheter is offered in various lengths.
This document describes the GlidePath™ Retro Long-Term Hemodialysis Catheter. It addresses the performance data and comparison to predicate devices, but does not describe a study involving an AI medical device or clinical performance data that would typically include acceptance criteria and reporting on sensitivity, specificity, or other performance metrics for an AI algorithm.
Therefore, I cannot provide the information requested in your prompt regarding AI device acceptance criteria and study details because the provided text is for a traditional medical device (a catheter) and does not contain information about an AI-powered device or its performance study.
The document focuses on demonstrating substantial equivalence of the catheter to a predicate device through non-clinical testing of various physical and functional characteristics.