510(k) Data Aggregation

    K Number
    K251505

    Validate with FDA (Live)

    Date Cleared
    2025-07-22

    (67 days)

    Product Code
    Regulation Number
    882.5275
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K251655

    Validate with FDA (Live)

    Date Cleared
    2025-07-18

    (49 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VersaCoat Tendon Protector is indicated for the management and protection of tendon injuries in which there has been no substantial loss of tendon tissue. The device may also be used to manage and protect surrounding tissues such as ligament and skeletal muscle. In these procedures, the device may encounter implanted structures such as anchors, grafts, staples, or sutures.

    Device Description

    VersaCoat Tendon Protector is an absorbable implant (device) designed to function as a gelatinous interface between an injured tendon and surrounding tissues, providing a non-constricting, protective encasement for injured tendons. VersaCoat Tendon Protector consists of a Hydrogel Pellet and Wetting Solution. The Pellet is a hollow, cylindrical hydrogel of alginate and hyaluronic acid. The Pellet is easy to handle and is designed for quick hydration with the Wetting Solution. The Pellet is supplied sterile, non-pyrogenic, for single use, in double peel pouches. The Wetting Solution hydrates the Pellet, rendering a viscous, flowable, tissue-adherent gel. The Wetting Solution is aqueous citrate and is provided in a dropper packaged in a double peel pouch. The Wetting Solution is sterile, non-pyrogenic, and is intended for single use only. A sterile container (dual syringe system) is offered and may be used to facilitate hydration of the Pellet with Wetting Solution.

    AI/ML Overview

    The provided FDA 510(k) Clearance Letter for the VersaCoat Tendon Protector (K251655) does not describe a study involving an AI/Machine Learning device. Instead, it concerns a physical medical device (surgical mesh) and its performance, safety, and equivalence to a predicate device.

    Therefore, I cannot provide information on acceptance criteria and study details related to an AI/Machine Learning device based on this document. The document details non-clinical laboratory tests for the physical properties and biocompatibility of the surgical mesh.

    Specifically, the document implies that "studies" refer to bench testing and biocompatibility assessments of the physical device, not an AI model.

    Summary of Information that CANNOT be Extracted for an AI/ML Device:

    • A table of acceptance criteria and the reported device performance for an AI/ML model: The document outlines functional and safety testing for a surgical mesh, including visual inspection, dimensional/weight measurements, gel integrity, handling, tissue adherence, conformance, and biocompatibility. These are not performance metrics for an AI/ML algorithm.
    • Sample sizes used for the test set and data provenance: Not applicable to a physical device.
    • Number of experts used to establish ground truth & qualifications: Not applicable to a physical device.
    • Adjudication method: Not applicable to a physical device.
    • Multi-Reader Multi-Case (MRMC) comparative effectiveness study: Not applicable. The device is a surgical mesh, not an AI tool assisting human readers.
    • Standalone (algorithm only) performance: Not applicable.
    • Type of ground truth used (expert consensus, pathology, outcomes data, etc.): Ground truth, in the context of an AI model, refers to the definitive correct answer against which the AI's predictions are compared. For a physical device like surgical mesh, "ground truth" relates to measurable physical and biological properties.
    • Sample size for the training set: Not applicable to a physical device.
    • How ground truth for the training set was established: Not applicable to a physical device.

    The document focuses on demonstrating substantial equivalence based on:

    • Intended Use/Indications for Use: Managing and protecting tendon injuries.
    • Materials of Construction: Alginate and hyaluronic acid hydrogel.
    • Operating Principle: Providing a gliding surface and physical separation of damaged tissues.
    • Fundamental Scientific Technology: Bioabsorbable hydrogel.
    • Performance: Assessed through bench testing (visual inspection, dimensions, gel integrity, handling, tissue adherence/conformance) and biocompatibility testing (cytotoxicity, sensitization, irritation, systemic toxicity, pyrogenicity, genotoxicity, subchronic toxicity, muscle implantation toxicity).

    In conclusion, this FDA clearance letter is for a physical medical device (surgical mesh) and does not contain the information requested about an AI/Machine Learning device's acceptance criteria or study methodologies.

    Ask a Question

    Ask a specific question about this device

    K Number
    K251175

    Validate with FDA (Live)

    Date Cleared
    2025-07-17

    (92 days)

    Product Code
    Regulation Number
    882.5275
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VersaWrap Nerve Protector is indicated for the management of peripheral nerve injuries in which there has been no substantial loss of nerve tissue.

    Device Description

    VersaWrap Nerve Protector is designed to function as an interface between an injured nerve and surrounding tissues and is indicated for use in peripheral nerve injuries where there is no significant loss of nerve tissue. VersaWrap Nerve Protector is a thin, flexible implant, designed to be a non-constricting gelatinous interface encasing peripheral nerves and the neural environment, that starts to absorb after implantation. VersaWrap Nerve Protector is designed to be flexible and conformable for placement on or around a peripheral nerve

    AI/ML Overview

    The provided FDA 510(k) Clearance Letter for the VersaWrap Nerve Protector outlines the determination of substantial equivalence to a predicate device. However, it does not contain specific acceptance criteria, reported device performance metrics in a defined table, or detailed information about a study proving the device meets said criteria in the format requested.

    The letter focuses on confirming substantial equivalence based on material composition, mechanism of action, and target population, acknowledging a difference in application method (gel vs. sheet). It summarizes non-clinical tests, including an animal study and bench tests, but these summaries do not include quantitative acceptance criteria or detailed performance data.

    Therefore, many of the requested fields cannot be filled directly from the provided text.

    Here's a breakdown of what can be extracted and what is missing:


    Acceptance Criteria and Device Performance

    Acceptance Criteria (What was measured / intended outcome)Reported Device Performance (Summary from the document)
    SafetyDemonstrated safe based on no procedure-related complications or device-related premature deaths in the animal study.
    Efficacy (Providing an interface, permitting normal axonal survival and growth)The animal study demonstrated the subject device can safely provide an interface between injured nerve and surrounding tissues, without device migration, permitting normal axonal survival and growth in a variety of clinically relevant nerve injury models, performing similar to the predicate device.
    No Device MigrationDemonstrated in the animal study and included in bench studies.
    Gel Integrity (Visual inspection, viscosity, cohesivity)Evaluated in bench studies; performance affirmed to support substantial equivalence.
    HandlingEvaluated in bench studies; performance affirmed to support substantial equivalence.
    CoverageEvaluated in bench studies; performance affirmed to support substantial equivalence.
    Dimensional and Weight MeasurementsEvaluated in bench studies; performance affirmed to support substantial equivalence.
    Visual Inspection (General quality/characteristics)Evaluated in bench studies; performance affirmed to support substantial equivalence.
    Conformability and FlexibilityDevice is described as "flexible and conformable for placement on or around a peripheral nerve." (Not explicitly a performance measure, but a design feature validated in bench tests).

    Study Details

    1. Sample size used for the test set and the data provenance:

      • Test Set Sample Size: For the animal study, the document states "rats underwent various peripheral nerve injuries." The specific number of rats or nerves tested is not provided.
      • Data Provenance: The animal study was "conducted," implying prospective data. The country of origin is not specified.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not provided. The document mentions "neurological assessment, and macroscopic and histological evaluation" as methods for evaluating safety and efficacy, which typically involve expert interpretation, but the number or qualifications of these experts are not specified.
    3. Adjudication method for the test set:

      • Not provided.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • Not applicable. This device is a nerve protector, not an AI-assisted diagnostic tool for human readers.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Not applicable. This is a medical device (nerve protector), not a software algorithm.
    6. The type of ground truth used:

      • For the animal study:
        • Neurological assessment: Clinical observation/evaluation.
        • Macroscopic evaluation: Gross anatomical inspection.
        • Histological evaluation: Microscopic tissue analysis (pathology).
    7. The sample size for the training set:

      • Not applicable / Not provided. For a medical device like this, the concept of a "training set" typically applies to machine learning models, which is not the case here. The development would involve engineering and material science, potentially with iterative testing, but not a formally defined "training set" in the computational sense.
    8. How the ground truth for the training set was established:

      • Not applicable / Not provided. (See point 7).

    Summary of Missing Information:

    The provided text from the 510(k) clearance letter gives a high-level overview of the non-clinical testing performed (animal study and bench studies) to demonstrate substantial equivalence. However, it lacks the fine-grained details often found in a full study report, such as:

    • Specific quantitative acceptance criteria with numerical targets.
    • Precise sample sizes for both animal and bench tests.
    • Detailed statistical analyses.
    • Information about expert qualifications and ground truth establishment methods beyond the types of evaluations performed.
    Ask a Question

    Ask a specific question about this device

    K Number
    K240817

    Validate with FDA (Live)

    Device Name
    VersaWrap
    Date Cleared
    2024-06-14

    (81 days)

    Product Code
    Regulation Number
    878.3300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VersaWrap is indicated for the management and protection of tendon injuries in which there has been no substantial loss of tendon tissue. The device may also be used in the management and protection of surrounding tissues such as skeletal muscle and ligaments.

    In these procedures, VersaWrap may encounter a variety of implanted structures such as anchors, grafts, staples, and sutures.

    Device Description

    VersaWrap® is an absorbable implant (device), designed to serve as an interface between the target tissues to provide a non-constricting, protective encasement. VersaWrap consists of a clear hydrogel (Sheet) and a wetting Solution. The clear Sheet is a thin membrane of alginate and hyaluronic acid. VersaWrap Sheet is easy to handle, and is designed for placement under, around, or over injured tissues and/or surrounding tissues. VersaWrap may encounter a variety of implanted structures such as anchors, grafts, staples. VersaWrap Sheet is supplied sterile, non-pyrogenic, for single use, in double peel pouches. The VersaWrap Solution is applied to the Sheet a gelatinous, tissue adherent layer (gel). The Solution, comprised of aqueous citrate, is provided sterile, non-pyrogenic, for single use, in a double peel pouch.

    AI/ML Overview

    The provided text is a 510(k) premarket notification decision letter and a 510(k) summary for a medical device called VersaWrap®. This document primarily focuses on regulatory approval based on demonstrating "substantial equivalence" to a predicate device, rather than detailed performance and validation studies typically found for AI/ML-based devices.

    Therefore, the document does not contain the information requested regarding acceptance criteria and the study that proves an AI device meets acceptance criteria. Specifically, it lacks:

    • A table of acceptance criteria and reported device performance.
    • Sample sizes for test sets, data provenance, number of experts, adjudication methods, MRMC studies, standalone performance data, or ground truth types.
    • Information on training set sample size or how ground truth was established for a training set.

    The document states: "Based on the risk-based assessment no additional testing is required to support the additional determination of substantial equivalence. The prior non-clinical and animal testing for the device were used to support the extended indications. Based on the risk-based assessment no clinical testing is required to support the additional determination of substantial equivalence." This indicates that the approval is based on equivalence to a previously approved device, not on new performance studies for an AI/ML component.

    Therefore, I cannot fulfill your request to describe the acceptance criteria and the study that proves the device meets the acceptance criteria from the provided text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K232029

    Validate with FDA (Live)

    Date Cleared
    2023-11-02

    (118 days)

    Product Code
    Regulation Number
    882.5275
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VersaWrap Nerve Protector is indicated for the management of peripheral nerve injuries in which there has been no substantial loss of nerve tissue.

    Device Description

    VersaWrap Nerve Protector (VersaWrap) is designed to function as an interface between an injured nerve and surrounding tissues and is indicated for use in peripheral nerve injuries where there is no significant loss of nerve tissue.
    VersaWrap Nerve Protector is a thin, flexible implant, designed to be a non-constricting gelatinous interface encasing peripheral nerves and the neural environment; that starts to absorb after implant.
    VersaWrap Nerve Protector is designed to be flexible and conformable for placement around a peripheral nerve.

    AI/ML Overview

    This document is an FDA 510(k) clearance letter for a medical device called "VersaWrap Nerve Protector." It states that the device is substantially equivalent to a legally marketed predicate device.

    The provided text does not contain any information about acceptance criteria or a study that proves the device meets those criteria in the context of an AI/ML powered medical device.

    This document is specifically for a physical medical device (a nerve cuff), and the content focuses on regulatory clearance based on substantial equivalence to an existing physical predicate device. It addresses aspects like:

    • Device Name: VersaWrap Nerve Protector
    • Regulation Number/Name: 21 CFR 882.5275, Nerve Cuff
    • Product Code: JXI
    • Indications for Use: "management of peripheral nerve injuries in which there has been no substantial loss of nerve tissue."
    • Predicate Device: VersaWrap Nerve Protector K201631
    • Device Description: "thin, flexible implant, designed to be a non-constricting gelatinous interface encasing peripheral nerves and the neural environment; that starts to absorb after implant."
    • Functional and Safety Testing: States "No additional functional or safety testing was required," implying that the substantial equivalence argument, based on the predicate device, was sufficient.
    • Comparative Technological Characteristics: Highlights material (Calcium alginate and hyaluronic acid), intended use, physical structure (sheet), and precautions, showing they are identical to the predicate.

    Therefore, I cannot fulfill your request to describe acceptance criteria and a study proving device performance for an AI/ML device based on this input, as this document is not about an AI/ML device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K213163

    Validate with FDA (Live)

    Device Name
    VersaWrap
    Date Cleared
    2021-10-29

    (31 days)

    Product Code
    Regulation Number
    878.3300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VersaWrap is indicated for the management and protection of tendon injuries in which there has been no substantial loss of tendon tissue. The device may also be used in the management and protection of surrounding tissues such as skeletal muscle and ligament.

    Device Description

    VersaWrap® is an absorbable implant (device), designed to serve as an interface between the target tissues and surrounding tissues to provide a non-constricting, protective encasement. VersaWrap consists of a clear Sheet and a wetting Solution. The clear Sheet is a thin membrane of crosslinked calcium alginate and glycosaminoglycan (GAG). VersaWrap Sheet is easy to handle, conformable, and is designed for placement under, around, or over injured tissues and/or surrounding tissues. VersaWrap Sheet is supplied sterile, non-pyrogenic, for single use, in double peel pouches. The VersaWrap Solution is applied to the Sheet rendering the Sheet a gelatinous, tissue adherent layer. The Solution, comprised of aqueous citrate, is provided sterile, non-pyrogenic, for single use, in a dropper, packaged in a double peel pouch.

    AI/ML Overview

    The provided text does not contain information about acceptance criteria or a study that proves a device meets such criteria. The document is an FDA 510(k) clearance letter for the VersaWrap device, which certifies its substantial equivalence to a predicate device.

    The document discusses the device description, indications for use, and confirms that non-clinical tests were performed. However, it does not detail specific acceptance criteria (e.g., performance metrics, thresholds) or the study design, sample sizes, ground truth establishment, or expert involvement that would typically be associated with proving these criteria were met for a new AI/medical device.

    Therefore, I cannot provide the requested information in the table format or answer the specific questions about sample sizes, ground truth, expert qualifications, or MRMC studies because this information is not present in the provided text.

    Ask a Question

    Ask a specific question about this device

    K Number
    K203600

    Validate with FDA (Live)

    Device Name
    VersaWrap
    Date Cleared
    2021-03-09

    (90 days)

    Product Code
    Regulation Number
    878.3300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VersaWrap is indicated for the management and protection of tendon injuries in which there has been no substantial loss of tendon tissue. The device may also be used in the management and protection of surrounding tissues such as skeletal muscle and ligament.

    Device Description

    VersaWrap® is an absorbable implant (device), designed to serve as an interface between the target tissues and surrounding tissues to provide a non-constricting, protective encasement. Versa Wrap consists of a clear Sheet and a wetting Solution. The clear Sheet is a thin membrane of crosslinked calcium alginate and glycosaminoglycan (GAG). VersaWrap Sheet is easy to handle, conformable, and is designed for placement under, around, or over injured tissues and/or surrounding tissues. VersaWrap Sheet is supplied sterile, non-pyrogenic, for single use, in double peel pouches. The VersaWrap Solution is applied to the Sheet after the Sheet is positioned. The Solution, comprised of aqueous citrate, is provided sterile, non-pyrogenic, for single use, in a dropper, packaged in a double peel pouch.

    AI/ML Overview

    This document is a 510(k) summary for the VersaWrap device, which is a resubmission (K203600) based on a previously cleared device (K200311). This type of submission focuses on demonstrating substantial equivalence to a predicate device rather than presenting new clinical study data with specific acceptance criteria and performance metrics.

    Therefore, the requested information regarding acceptance criteria, study details, sample sizes, expert involvement, adjudication, MRMC studies, standalone performance, and ground truth establishment cannot be fully provided from the given document.

    Here's what can be extracted and inferred based on the nature of a 510(k) submission for a device that is "identical to the predicate device" with "differences in the indication for use" that "do not affect the safety and effectiveness":

    1. Table of Acceptance Criteria and Reported Device Performance:

    No specific "acceptance criteria" for performance metrics (e.g., sensitivity, specificity, accuracy) are reported for this 510(k) submission. This is because it's a re-submission of an "identical" device. The acceptance criteria for this submission would have been demonstrating:

    • Substantial Equivalence: That the device is as safe and effective as a legally marketed predicate device.
    • Safety and Effectiveness for Modified Indications: That the modified indications for use still fall within the demonstrated safety and effectiveness profile of the original device and its predicate.
    Acceptance Criteria (Implied for 510(k) Resubmission)Reported Device Performance (Implied from Summary)
    Device is identical to predicate K200311.Confirmed: "VersaWrap is identical to the predicate device."
    Differences in Indications do not affect safety/effectiveness.Confirmed: "Differences in the indication for use are not critical to the intended therapeutic... because the differences do not affect the safety and effectiveness of the device when used as labeled."
    Non-clinical testing supports modified indications.Confirmed: "The prior non-clinical testing and animal model studies were used to support the modified indications."
    Device is as safe and effective as legally marketed predicate.Confirmed: "Conclusion(s) drawn from the nonclinical tests demonstrate that the device is as safe, as effective, and performs as well as or better than the identified legally marketed device."

    2. Sample size used for the test set and the data provenance:

    • Sample Size (Test Set): Not applicable for this 510(k) submission, as it relies on previous testing of the identical predicate device. No new test set data is presented.
    • Data Provenance: No new data provenance information is provided as the submission relies on "prior non-clinical testing and animal model studies" for the predicate device. The document does not specify the country of origin or whether these prior studies were retrospective or prospective.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

    • Not applicable, as no new test set requiring new ground truth establishment is detailed in this 510(k) summary. The summary refers to existing non-clinical and animal model studies, but does not provide details on how ground truth was established within those studies.

    4. Adjudication method for the test set:

    • Not applicable, as no new test set or clinical study requiring adjudication is detailed in this 510(k) summary.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    • No. The VersaWrap device is a surgical mesh/implant, not an AI-powered diagnostic or assistive tool. Therefore, an MRMC comparative effectiveness study involving human readers and AI assistance is not relevant to this device.

    6. If a standalone (i.e., algorithm only without human-in-the loop performance) was done:

    • No. This device is a physical surgical implant, not an algorithm or software. Standalone algorithm performance is not applicable.

    7. The type of ground truth used:

    • For the original predicate device (K200311), the ground truth for safety and effectiveness would have been established through a combination of:
      • Non-clinical testing: (e.g., mechanical properties, biocompatibility, degradation profiles).
      • Animal model studies: (e.g., observation of healing, adhesion formation, tissue response in vivo).
      • Literature review and comparison to existing similar devices.
    • This 510(k) summary (K203600) states that "The prior non-clinical testing and animal model studies were used to support the modified indications." This implies the same types of ground truth from the predicate were leveraged.

    8. The sample size for the training set:

    • Not applicable. This device is not an AI model, so there is no concept of a "training set" in the context of machine learning.

    9. How the ground truth for the training set was established:

    • Not applicable, as there is no training set for this type of medical device.

    In summary: This 510(k) submission (K203600) is for a physical surgical implant (VersaWrap) that is identical to an already cleared predicate device (K200311), with minor modifications to the Indications for Use that do not impact its fundamental safety or effectiveness. Therefore, the submission primarily focuses on demonstrating this equivalence and does not present new clinical study data, detailed acceptance criteria, or performance metrics in the way an innovative diagnostic or AI device might. The "study" proving the device meets the (implicit) acceptance criteria is the demonstration of substantial equivalence through comparison to the predicate and leveraging its existing non-clinical and animal model data.

    Ask a Question

    Ask a specific question about this device

    K Number
    K201631

    Validate with FDA (Live)

    Date Cleared
    2020-09-14

    (90 days)

    Product Code
    Regulation Number
    882.5275
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VersaWrap Nerve Protector is indicated for the management of peripheral nerve injuries in which there has been no substantial loss of nerve tissue.

    Device Description

    VersaWrap Nerve Protector (VersaWrap) is designed to function as an interface between an injured nerve and surrounding tissues and is indicated for use in peripheral nerve injuries where there is no significant loss of nerve tissue. VersaWrap Nerve Protector is a thin, flexible implant, designed to be a non-constricting gelatinous interface encasing peripheral nerves and the neural environment; that starts to absorb after implant. VersaWrap Nerve Protector is designed to be flexible and conformable for placement around a peripheral nerve

    AI/ML Overview

    The provided text describes non-clinical tests and an animal study for the VersaWrap Nerve Protector. Here's a breakdown of the requested information based on the provided input:

    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria CategorySpecific Test/PurposeAcceptance Criteria SummaryReported Device Performance
    Non-Clinical TestsDimensional & Visual InspectionDirect measurement of mass, lengths, width, thickness with micrometers, calipers, pH meter or balance; and visual inspection.Dimensional analysis was completed to verify the dimensions and visual characteristics and met specifications.
    Pliability/Tissue Conformance and AdherenceThe device is placed on a simulated model and graded for visual conformance and adherence.Visual inspection was conducted and met specifications.
    SwellingDirect measurement of the device (with micrometers, calipers) when exposed to fluid.Dimensional analysis was completed and met specifications.
    Strength/PunctureDirect measurement of the device strength/puncture when measured with a probe.Testing was completed and met specifications.
    Pouch Seal Integrity/Sterile BarrierThe integrity of the pouch was verified with a visual inspection, peel tester, and burst tester.Testing was completed and met specifications.
    SterilizationThe e-beam sterilization process was validated to achieve a sterility assurance level (SAL) of 10-6 per ISO 11137.Testing was completed and met specifications.
    Bacterial Endotoxin ValidationThe bacterial endotoxin validation testing was conducted per USP <85> Bacterial Endotoxins and Ph.Eur. Chpt 2.6.14.Testing was completed and met specification.
    CytotoxicityThe device was evaluated for potential cytotoxic effects using an in vitro mammalian cell culture test, following ISO 10993-5 guidelines.The test extract showed no evidence of causing cell lysis or toxicity.
    SensitizationThe device was evaluated for the potential to cause delayed dermal contact sensitization in a guinea pig maximization test, based on ISO 10993-10.The test article showed no evidence of causing delayed contact sensitization.
    IrritationThe device was evaluated for the potential to cause irritation following intracutaneous injection, based on ISO 10993-10.There was no evidence of significant irritation from the extracts injected intracutaneously.
    Acute Systemic ToxicityThe device was evaluated for acute systemic toxicity, based on ISO 10993-11.The sesame oil test article extracts and the sodium chloride test article extracts injected met the passing requirements of the test.
    PyrogenicityThe device was evaluated for material mediated pyrogenicity in the rabbit.The total rise of temperatures during the observation period was within acceptable limits (implied by "Testing was completed and met specifications" below).
    GenotoxicityThe device was evaluated for mutagenic potential, mutagenic changes, and to produce cytogenetic damage.Extract did not cause cytogenetic damage/micronuclei formation. Extracts were well within the limits defined for a negative response and the test article is considered non-mutagenic.
    Subchronic ToxicityThe device was surgically implanted in the subcutaneous tissue of the rat to evaluate potential systemic toxicity and local tissue response at the implantation sites.No evidence of systemic toxicity following subcutaneous implantation. Microscopically, the test article was classified as a non-irritant.
    Muscle ImplantationThe study assessed local tissue effects and absorption profile following implantation in muscle tissue in at multiple timepoints.At long term timepoints the device was considered to be a non-irritant and a slight irritant at earlier weeks following implantation when compared to the control. Microscopic evaluation demonstrated the device is bioresorbing as expected.
    Neurotoxicity AssessmentA risk analysis was conducted to determine any neurotoxicity risk to the patient.An analysis was conducted to determine any neurotoxicity risk to the patient (implied satisfactory outcome given overall conclusion).
    Animal StudyPerformance/SafetyComparable safety and performance to predicate device, no significant events, no apparent difference in character or severity of reactivity to test or predicate implant, no microscopic changes in the nerve at any interval for either test or Integra implants, similar microscopic appearance of nerve and surrounding tissue for control and VersaWrap.VersaWrap animals and the predicate control animals demonstrated equivalent safety and equivalent performance results; there were no significant events reported in any group. Histopathological evaluations showed no apparent difference in the character or severity of the reactivity, and no microscopic changes in the nerve.

    2. Sample size used for the test set and the data provenance

    • Test Set Sample Size: The document states the "sample size was selected to be large enough to show consistent results and to be able to compare the test, control, and untreated groups" for the animal study. However, a specific numerical sample size is not explicitly provided for the animal study (e.g., "N=X rats"). For non-clinical tests, sample sizes are implied by "testing was completed" but not detailed (e.g., number of pouches for seal integrity, number of samples for cytotoxic evaluation).
    • Data Provenance:
      • Country of Origin: Not specified.
      • Retrospective or Prospective: The animal study appears to be prospective as it involved conducting the study on "multiple injury types for subject device, predicate control device, and untreated groups" with data collected at "an early period, a mid-term period; and a late period." The non-clinical tests are also inherently prospective as they are performed on the device.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • The document does not provide information on the number of experts or their qualifications used to establish ground truth for the animal study or any other test. It mentions "Histopathological evaluations were performed," which implies expert analysis, but details are lacking.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • The document does not specify any adjudication method for the test set, whether for the animal study or non-clinical tests.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, an MRMC comparative effectiveness study was not done. This device is a physical nerve protector and not an AI-assisted diagnostic tool. Therefore, the concept of "human readers improve with AI vs without AI assistance" is not applicable.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    • No, a standalone algorithm-only performance study was not done. This device is a physical medical implant, not an algorithm or software.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • For the animal study, the ground truth appears to be based on pathology/histopathology ("Histopathological evaluations were performed to assess local and systemic tissue effects...There were no microscopic changes in the nerve...") and physiological/observational outcomes data ("motor and sensory neurological assessments were conducted...no significant events reported").
    • For non-clinical tests, the "ground truth" is typically defined by pre-defined specifications and validated test methods (e.g., ISO standards for biocompatibility, direct measurements for dimensional analysis).

    8. The sample size for the training set

    • This device is not an AI/ML model, so there is no concept of a "training set" as described in the context of AI.

    9. How the ground truth for the training set was established

    • As there is no training set for an AI/ML model, this question is not applicable.
    Ask a Question

    Ask a specific question about this device

    K Number
    K200311

    Validate with FDA (Live)

    Date Cleared
    2020-03-06

    (29 days)

    Product Code
    Regulation Number
    878.3300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    VersaWrap is indicated for the management and protection of tendon injuries in which there has been no substantial loss of tendon tissue.

    Device Description

    VersaWrap is an absorbable implant (device), designed to serve as an interface between the tendon and tendon sheath or the surrounding tissues, which provides a non-constricting, protective encasement for injured tendons. VersaWrap consists of a Sheet and a Wetting Solution. The Sheet is a thin membrane of crosslinked calcium alginate and glycosaminoglycan. VersaWrap Sheet is easy to handle, conformable, and is designed for easy placement under, around, or over the injured tendon. VersaWrap Sheet is supplied sterile, non-pyrogenic, for single use, in double peel pouches. The VersaWrap Solution is applied to the Sheet after the Sheet is positioned onto damaged tissue. The Solution is comprised of aqueous citrate and is provided in a dropper packaged in a double peel pouch. The Solution is sterile, non-pyrogenic, and is intended for single use only.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the VersaWrap Tendon Protector, a medical device. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device, rather than providing extensive clinical study data (such as a multi-reader multi-case comparative effectiveness study or a standalone algorithm-only performance study) with detailed acceptance criteria and performance metrics typically associated with AI/software-as-a-medical-device.

    Therefore, much of the requested information regarding acceptance criteria, study design for performance evaluation (test set, training set, ground truth, expert involvement), and comparative effectiveness is not typically found in a 510(k) summary for a physical implantable device.

    However, based on the provided text, I can infer the following:

    1. A table of acceptance criteria and the reported device performance:

    The document indicates that "Functional and Safety Testing" was performed to verify that the device design met functional and performance requirements. The specific type of testing mentioned is "dimensional/visual inspection." While explicit acceptance criteria and corresponding performance results are not detailed in a quantitative table within this document, the implication of the 510(k) clearance is that these tests passed, demonstrating equivalence to the predicate.

    Acceptance Criteria CategoryReported Device Performance (Implied)
    Functional RequirementsMet requirements
    Performance RequirementsMet requirements
    Dimensional/VisualMet specifications
    SafetyDemonstrated to be safe

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):

    The document mentions "representative samples of the device underwent bench testing." It does not specify the exact sample size for these bench tests, the country of origin of the data, or whether it was retrospective or prospective. Given it's bench testing, it refers to product samples rather than patient data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):

    This type of information is not relevant or provided in a 510(k) for a physical implantable device like the VersaWrap Tendon Protector. "Ground truth" established by experts is typically for diagnostic devices or AI algorithms that interpret medical images or data. The "acceptance criteria" here relate to the physical and functional properties of the device itself.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

    Not applicable for the type of device and testing described. Adjudication methods are typically used in clinical studies or performance evaluations involving human interpretation of data, often with AI.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

    No. An MRMC comparative effectiveness study is not mentioned. This type of study is primarily for diagnostic devices, particularly those involving AI in image interpretation. The VersaWrap Tendon Protector is an implantable surgical mesh.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    No. This concept is for AI/software devices. The VersaWrap Tendon Protector is an absorbable implant.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc):

    For this device, "ground truth" would relate to whether the device physically performs as intended (e.g., integrity, dimensions, sterility, biocompatibility) rather than a diagnostic 'truth'. The text doesn't specify the exact type of "ground truth" but implies that the device's physical and functional properties were evaluated against predefined specifications and requirements.

    8. The sample size for the training set:

    Not applicable. There is no mention of a "training set" as this is not an AI/machine learning device.

    9. How the ground truth for the training set was established:

    Not applicable. There is no mention of a "training set" or corresponding ground truth establishment process for this device.

    Summary of the Study (as described in the 510(k) summary):

    The regulatory submission for the VersaWrap Tendon Protector focused on demonstrating substantial equivalence to a predicate device (K160364 VersaWrap® Tendon Protector). This process primarily involves showing that the new device has the same intended use, similar technological characteristics, and does not raise new questions of safety or effectiveness.

    The study mentioned is bench testing to verify that the device design met functional and performance requirements. This included "dimensional/visual inspection." The conclusion of the submission is that the subject device is equivalent to the predicate device based on equivalent intended use and no technological differences that raise new safety and effectiveness questions. The document does not provide details on the methodology, specific quantitative results, or acceptance criteria for these bench tests beyond their general purpose.

    Ask a Question

    Ask a specific question about this device

    K Number
    K160364

    Validate with FDA (Live)

    Date Cleared
    2016-06-10

    (122 days)

    Product Code
    Regulation Number
    878.3300
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The VersaWrap Tendon Protector is indicated for the management and protection of tendon injuries in which there has been no substantial loss of tendon tissue.

    Device Description

    VersaWrap is an absorbable implant (device), designed to serve as an interface between the tendon and tendon sheath or the surrounding tissues, which provides a non-constricting, protective encasement for injured tendons. VersaWrap consists of a Sheet and a wetting Solution. The Sheet is a thin membrane of crosslinked calcium alginate and glycosaminoglycan. VersaWrap Sheet is easy to handle, conformable, and is designed for easy placement under, around. or over the injured tendon. VersaWrap Sheet is supplied sterile, non-pyrogenic, for single use, in double peel pouches. The VersaWrap Solution is applied to the Sheet after the Sheet is positioned onto damaged tissue. The Solution is comprised of aqueous citrate and is provided in a dropper packaged in a double peel pouch. The Solution is sterile, non-pyrogenic, and is intended for single use only.

    AI/ML Overview

    The provided text is a 510(k) summary for the VersaWrap Tendon Protector. It describes the device, its intended use, and substantial equivalence to a predicate device, but it does not contain information about acceptance criteria or a study that proves the device meets specific performance acceptance criteria in the way typically expected for an AI/CADe device.

    This document is for a medical device (a tendon protector), not an AI/CADe system. Therefore, many of the requested categories (like sample size for test/training sets, experts for ground truth, MRMC studies, standalone performance) are not applicable or described in the context of this type of device submission.

    Here's a breakdown of the information that can be extracted, and what is missing based on the request:

    1. Table of acceptance criteria and reported device performance:

    The document describes "Functional and Safety Testing" and "Non-Clinical Tests Submitted." However, it presents these as categories of tests performed rather than specific quantitative acceptance criteria with corresponding reported performance values. For instance, it mentions "Puncture strength" but does not provide a target value for puncture strength or the measured value for the VersaWrap.

    Acceptance Criteria CategoryReported Device Performance
    Functional & Performance RequirementsDevice design met functional and performance requirements (general statement)
    Visual InspectionPerformed
    Dimensional & Weight MeasurementsPerformed
    Puncture StrengthPerformed (no specific value or criteria given)
    HandlingPerformed (no specific criteria given)
    Tissue Adherence and ConformancePerformed (no specific criteria given)
    Chicken Flexor Tendon Repair ModelPerformed (no specific criteria or results given)
    Biocompatibility (ISO 10993 standards)
    Non-cytotoxicDemonstrated
    Non-pyrogenicDemonstrated
    Non-irritatingDemonstrated
    Non-sensitizingDemonstrated
    Non-toxicDemonstrated
    Non-genotoxicDemonstrated
    Subchronic toxicity (13 weeks)Performed (no specific criteria or results given)
    Muscle implantation toxicity/irritationPerformed (no specific criteria or results given)
    Protective Interface FunctionAlginate-glycosaminoglycan matrix provides a protective interface to improve mobility of repaired tendons (demonstrated by physical testing and animal studies)

    Missing: Specific, quantifiable acceptance criteria (e.g., "puncture strength > X Newtons") and the direct numerical results demonstrating the device met those criteria.

    2. Sample size used for the test set and the data provenance:

    • Test Set Sample Size: Not applicable in the context of this device. The tests mentioned are bench testing and animal studies, not a "test set" of patient data for an algorithm.
    • Data Provenance: The document mentions "animal studies" (specifically, a "Chicken flexor tendon repair model"). No country of origin is specified for these studies. The studies are non-clinical, not retrospective or prospective patient data.

    3. Number of experts used to establish the ground truth for the test set and their qualifications:

    Not applicable in the context of this device. The ground truth for device performance is established via physical and chemical testing, and observations in animal models, not by expert consensus on clinical data.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set:

    Not applicable. This concept applies to expert review of clinical cases, not the physical testing of a medical device.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, and the effect size of how much human readers improve with AI vs without AI assistance:

    Not applicable. This device is a physical tendon protector, not an AI or CADe system intended to assist human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

    Not applicable. This is a physical device, not an algorithm.

    7. The type of ground truth used:

    The ground truth for the performance claims would be:

    • Physical properties: Measured values from bench tests (e.g., puncture strength, dimensions).
    • Biocompatibility standards: Results against defined ISO 10993 criteria.
    • Animal study observations: Outcomes from the "Chicken flexor tendon repair model" (e.g., improved mobility, protective interface functionality).

    8. The sample size for the training set:

    Not applicable. This device does not have a "training set" in the sense of machine learning.

    9. How the ground truth for the training set was established:

    Not applicable.

    In summary: The provided document is a regulatory submission for a physical medical device. It details functional, safety, and biocompatibility testing designed to demonstrate substantial equivalence to a predicate device. It does not contain the types of information (e.g., quantitative acceptance criteria for image analysis performance, clinical test set details, expert ground truth, AI/CADe study methodologies) typically requested for an AI/CADe device.

    Ask a Question

    Ask a specific question about this device