Tumark Vision, Tumark Professional, Tumark Q, Tumark Professional Q-Shape
The Tumark® Vision, the Tumark® Professional, the Tumark® Professional Q-Shape are intended to attach a marker to soft breast tissue and axillary lymph nodes, following an open or a percutaneous procedure to radiographically mark the location of the surgical site. It is not indicated to be used with magnetic resonance imaging (MRI) techniques.
The Tumark® Vision, Tumark® Professional, Tumark® Q, and Tumark® Professional Q-Shape are sterile products for single use only. Each consists of a non-absorbable nickel-titanium clip marker, an introducer cannula, and a plastic handle. The clip marker is contained within the cannula when new and unopened. The cannula tip is bevelled, has markings 1 cm apart for measuring depth, and a textured surface behind the tip. The handle has a slide button for one-handed marker placement and a safety catch system to prevent premature deployment. The clip markers have different shapes: spherical (Tumark Vision), U-shape (Tumark Professional), Q-shape (Tumark Q), and Q-shaped (Tumark Professional Q Shape). The symbol of the clip marker shape is depicted on the handle.
Based on the provided text, the device in question is a tissue site marking system, specifically the Tumark Vision, Tumark Professional, Tumark Q, and Tumark Professional Q-Shape. These devices are intended to attach a marker to soft breast tissue and axillary lymph nodes to radiographically mark the location of a surgical site.
It's important to note that this document is a 510(k) premarket notification for a medical device. This type of submission primarily focuses on demonstrating substantial equivalence to a previously cleared predicate device, rather than proving safety and effectiveness through extensive new clinical trials like a PMA (Premarket Approval) application would. Therefore, the "study that proves the device meets the acceptance criteria" refers to the non-clinical and limited clinical data submitted for substantial equivalence.
Here's a breakdown of the requested information based on the provided text:
1. Table of Acceptance Criteria and Reported Device Performance
Aspect | Acceptance Criteria | Reported Device Performance |
---|---|---|
Biocompatibility | Meets requirements of ISO 10993-1; absence of toxic leachables and contaminants; acceptable EO residual values. | Components and manufacturing processes similar to predicate and reference devices. Made from standard materials. EO residual values far below acceptable limits. Cytotoxicity testing and toxicological review confirmed absence of toxic leachables and contaminants. All requirements met. |
Sterilization & Shelf Life | All acceptance criteria met during sterility testing; defined shelf-life proven based on packaging and device testing after real-time aging; all defined acceptance criteria met. | Sterility testing confirmed all acceptance criteria were met. Shelf-life proven after real-time aging, with all defined acceptance criteria met during shelf life testing. All acceptance criteria met. |
Device Function | Marker can be placed in the target area. | U-, Q- and Vision markers could be deployed. The device performs as intended. All acceptance criteria met. |
Device Performance | Clip marker and cannula are recognized in ultrasound, mammography, and MR imaging. | Clip markers and cannulas are recognized in ultrasound, mammography, and MR imaging. All acceptance criteria are met. |
Device Stability during transport | Devices are not damaged during transport. | Drop tests performed. Devices were not damaged. All acceptance criteria are met. |
Clinical Equivalence | Clinical support for the use of markers inside axillary lymph nodes; support for the defined indication for use. | A literature review was performed to clinically support the use of the markers inside axillary lymph nodes. Physician statements were obtained to support the indication for use. This supports the substantial equivalence to predicate devices with similar indications. Claim of substantial equivalence made. |
2. Sample Size Used for the Test Set and Data Provenance
The document does not specify a quantitative "sample size" in terms of number of patients or cases for the in vitro (bench) testing. The "test set" for the non-clinical evaluations appears to be the devices themselves.
- Sample Size for Bench Testing: Not explicitly stated as a numerical count of devices tested. The text says "Bench testing was performed to validate the device design" and lists aspects like "Device Function," "Device Performance," and "Device Stability during transport."
- Data Provenance: The studies are described as "in vitro testing" and "bench testing." There is also a "Clinical Analysis" which involved a "literature review" and "physician statements."
- Country of Origin: Not explicitly stated, but the applicant (SOMATEX Medical Technologies GmbH) is based in Berlin, Germany.
- Retrospective or Prospective: The bench testing is presumably prospective (planned tests). The literature review is retrospective. The physician statements are likely prospective or current.
3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts
- Number of Experts: Not specified.
- Qualifications of Experts: Not specified. The "Clinical Analysis" mentions "physician statements," implying medical professionals.
4. Adjudication Method for the Test Set
- Adjudication Method: Not applicable or not specified for the presented bench testing. The evaluation is based on meeting pre-defined acceptance criteria for the physical and functional characteristics of the device. For the clinical analysis, "physician statements" were obtained, but no multi-reader adjudication process is described.
5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done, and what was the effect size of how much human readers improve with AI vs without AI assistance
- MRMC Study: No MRMC comparative effectiveness study was done or reported. This device is a physical marker, not an AI-assisted diagnostic tool for image interpretation. Therefore, the concept of "how much human readers improve with AI vs without AI assistance" is not applicable.
6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) was done
- Standalone Performance: Not applicable. This is a physical medical device (implantable clip), not an algorithm or software.
7. The Type of Ground Truth Used
- For Bench Testing: The "ground truth" is based on engineered specifications and the physical performance of the device against those specifications (e.g., successful deployment, visibility under imaging modalities, structural integrity). This is a technical and objective validation against design requirements.
- For Clinical Analysis (Supporting Indications): The "ground truth" for the expanded indication (axillary lymph nodes) relies on a literature review and physician statements, suggesting a consensus of existing medical knowledge and expert opinion. It is not based on direct patient outcomes data from a new clinical study.
8. The Sample Size for the Training Set
- Training Set Sample Size: Not applicable. This is a physical device, not a machine learning algorithm that requires a "training set." The development of the device would involve engineering design and iterative testing, not AI model training.
9. How the Ground Truth for the Training Set was Established
- Ground Truth for Training Set Establishment: Not applicable as there is no "training set" in the context of an AI/ML model for this device. The design and validation of this device follow traditional medical device engineering and testing methodologies.
Ask a specific question about this device