Found 2 results

510(k) Data Aggregation

    K Number
    K150359
    Device Name
    Tensyn Plug
    Date Cleared
    2015-05-07

    (84 days)

    Product Code
    Regulation Number
    888.3030
    Reference & Predicate Devices
    Why did this record match?
    Device Name :

    Tensyn Plug

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The subject device is intended as an adjunct in fracture repair involving metaphyseal and periarticular small bone fragments where screws are not indicated, and as an adjunct in external and intramedullary fixation systems involving plates and rods, with fracture braces and casting. Specifically, the Tensyn Plug is intended to provide fixation during the healing process following:

    • A syndesmotic trauma, such as fixation of syndesmosis (syndesmosis disruptions) in connection with Weber B and C ankle fractures
    • -Acromioclavicular separations due to coracoclavicular ligament disruptions
    • Syndesmotic trauma, such as fixation of dorsal distal radiolunar ligament (DRUL) disruptions;
    • -Tarasometatarsal (TMT) injury, such as fixation of foot soft tissue separations due to a Lisfranc injury (Midfoot Reconstruction); and
    • -Hallux Valgus reconstruction (correction) by providing for the reduction of 1st metatarsal -2nd metatarsal intermetatarsal angle.

    The Tensyn Plug, when used for fixation of bone-to-bone or soft-tissue to- bone, is intended as a fixation post, distribution bridge, or for distributing suture tension over areas of ligament or tendon repair. Specifically, the Tensyn Plug is indicated for Carpal Metacarpal (CMC) joint arthroplasty as an adjunct in the suspension of the thumb metacarpal during the healing process of hematoma distraction arthroplasty by providing stabilization at the base of the first and second metacarpal when the trapezium has been excised due to osteoarthritis.

    Device Description

    The Tensyn Plug is a knotless system for fixation of syndesmosis disruptions, acromioclavicular repair, tarasometatarsal injury, hallux valgus reconstruction, and carpal metacarpal joint arthroplasty. The Tensyn Plug is a low profile system comprised of a coated flat polyethylene terephthalate (PET) suture band tensioned and secured between a narrow button and a locking cap assembly. The Tensyn Plug is available in stainless steel and titanium.

    AI/ML Overview

    This document is a 510(k) premarket notification for the Tensyn™ Plug, a medical device. It focuses on demonstrating substantial equivalence to predicate devices rather than providing a study where the device meets acceptance criteria. Therefore, much of the requested information regarding specific acceptance criteria metrics, detailed study design, and performance outcomes for a device that "meets acceptance criteria" in terms of clinical accuracy or diagnostic performance is not present in this regulatory filing.

    However, I can extract information related to the device's performance testing which serves to establish substantial equivalence.

    Here's a breakdown of the available information based on your request:

    1. Table of Acceptance Criteria and Reported Device Performance:

    The document does not explicitly state numerical "acceptance criteria" in a table format that would typically be seen for diagnostic or AI-based devices. Instead, it refers to performance testing conducted to demonstrate substantial equivalence to predicate devices. The implicit acceptance criterion is that the Tensyn™ Plug performs similarly or equivalently to the predicate devices in the described tests.

    Acceptance Criterion (Implicit)Reported Device Performance
    Rotational LoadingDemonstrated substantial equivalence to predicate devices.
    Cyclic LoadingDemonstrated substantial equivalence to predicate devices.
    Ultimate LoadDemonstrated substantial equivalence to predicate devices.
    Load at 3mmDemonstrated substantial equivalence to predicate devices.
    Shear TestDemonstrated substantial equivalence to predicate devices.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document refers to "testing" performed but does not specify the sample size for the test set (e.g., number of devices tested, number of simulated applications). It also does not mention data provenance (e.g., country of origin, retrospective/prospective) as the testing appears to be primarily mechanical performance testing on the device itself, rather than clinical data from human subjects.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications:

    Not applicable. This type of information is relevant for studies involving human interpretation or diagnostic accuracy. The testing described (rotational loading, cyclic loading, ultimate load, load at 3mm, and shear test) is mechanical and likely involves engineering analysis and measurements, not human expert consensus for "ground truth."

    4. Adjudication Method for the Test Set:

    Not applicable. Adjudication methods like "2+1" or "3+1" are used when multiple readers/experts are involved in establishing ground truth, which is not the case for the mechanical performance testing described.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done:

    No. An MRMC comparative effectiveness study is typically performed for diagnostic devices to assess how much human readers improve with AI assistance. This document describes a mechanical fixation device, and an MRMC study is not relevant to its regulatory submission for substantial equivalence.

    6. If a Standalone (algorithm only without human-in-the-loop performance) was done:

    Not applicable. The Tensyn™ Plug is a mechanical implant, not an algorithm. The "standalone performance" refers to the device's mechanical integrity and strength under various loads.

    7. The Type of Ground Truth Used:

    For the mechanical performance tests, the "ground truth" would be established by physical measurements and engineering standards for mechanical properties (e.g., specific load at which failure occurs, displacement at a certain load). This is not expert consensus, pathology, or outcomes data in the usual clinical sense.

    8. The Sample Size for the Training Set:

    Not applicable. This device is not an AI/ML algorithm that requires a "training set."

    9. How the Ground Truth for the Training Set was Established:

    Not applicable, as there is no training set for this mechanical device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K143092
    Device Name
    Tensyn Plug
    Date Cleared
    2015-02-11

    (106 days)

    Product Code
    Regulation Number
    888.3030
    Reference & Predicate Devices
    Why did this record match?
    Device Name :

    Tensyn Plug

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Tensyn Plug is intended to provide fixation during the healing process following a syndesmotic trauma, such as fixation of syndesmosis disruptions) in connection with Weber B and C ankle fractures which have been properly stabilized and which allow stable placement of the Tensyn Plug apart from any other fixation hardware. For fixation during the healing process of acromioclavicular separations due to coracoclavicular ligament disruptions, the Tensyn Plug is used in conjunction with, but not connected to, supplemental fixation. The subject device is intended as an adjunct in fracture repair involving metaphyseal and periarticular small bone fragments where screws are not indicated, and as an adjunct in external and intramedullary fixation systems involving plates and rods, with fracture braces and casting. Specifically, the Tensyn Plug is intended to provide fixation during the healing process following: 1) Syndesmotic trauma, such as fixation of dorsal distal radiolunar ligament (DRUL) disruptions; 2) Tarasometatarsal (TMT) injury, such as fixation of foot soft tissue separations due to a Lisfranc injury (Midfoot Reconstruction); and 3) Hallux Valgus reconstruction (correction) by providing for the reduction of 1st metatarsal -2nd metatarsal intermetatarsal angle. The Tensyn Plug, when used for fixation of bone-to-bone or soft-tissue-to-bone, is intended as a fixation post, distribution bridge, or for distributing suture tension over areas of ligament or tendon repair. Specifically, the Tensyn Plug is indicated for Carpal Metacarpal (CMC) joint arthroplasty as an adjunct in the suspension of the thumb metacarpal during the healing process of hematoma distraction arthroplasty by providing stabilization at the base of the first and second metacarpal when the trapezium has been excised due to osteoarthritis.

    Device Description

    The Tensyn Plug is a knotless system for fixation of syndesmosis disruptions, acromio-clavicular repair, tarasometatarsal injury, hallux valgus reconstruction, and carpal metacarpal joint arthroplasty. The Tensyn Plug is a low profile system comprised of a coated flat polyethylene terephthalate (PET) suture band tensioned and secured between a narrow button and a locking cap assembly. The Tensyn Plug is available in stainless steel.

    AI/ML Overview

    The provided document is a 510(k) summary for the Tensyn™ Plug, a medical device for fixation during healing processes. It discusses the device's indications for use, technical characteristics, and performance data for demonstrating substantial equivalence to predicate devices. However, the document does not include specific acceptance criteria, detailed results of the studies, sample sizes for test or training sets, ground truth establishment methods, expert qualifications, or details about multi-reader multi-case studies.

    Therefore, I cannot provide the requested information in the format specified because the necessary details are not present in the provided text.

    Here's an overview of what is available and what is missing:

    What is present in the document:

    • Device Name: Tensyn™ Plug
    • Device Description: Knotless system for fixation, comprised of a coated flat polyethylene terephthalate (PET) suture band tensioned and secured between a narrow button and a locking cap assembly, available in stainless steel.
    • Indications for Use: Detailed for various conditions (syndesmotic trauma, acromioclavicular separations, fracture repair, Lisfranc injury, Hallux Valgus reconstruction, Carpal Metacarpal (CMC) joint arthroplasty).
    • Predicate Devices: Tensyn Band (K141264, K131850), Arthrex, Inc. Mini TightRope Repair Kit (K061925), Arthrex, Inc. CMC Mini TightRope (K140328), Biomet, Inc. ToggleLoc System (K083070).
    • Types of Performance Testing: Rotational loading, cyclic loading, ultimate load, load at 3mm, and shear test.
    • Conclusion from Testing: "The testing demonstrated that the Tensyn Plug is substantially equivalent to the predicate devices."

    What is missing from the document (and therefore cannot be provided in the answer):

    1. Table of Acceptance Criteria and Reported Device Performance: While types of tests are listed, the specific quantitative acceptance criteria (e.g., "ultimate load must be > X N") and the numerical results obtained for the Tensyn™ Plug are not provided.
    2. Sample Size Used for the Test Set and Data Provenance: No information is given regarding the number of devices or units tested for each performance test, nor the origin or nature (retrospective/prospective) of any clinical data, as this is a mechanical testing report, not a clinical study report.
    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications: Not applicable, as this involves mechanical testing, not a diagnostic or AI-driven device requiring expert adjudication of ground truth from images or clinical data.
    4. Adjudication Method for the Test Set: Not applicable for mechanical testing.
    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study: No information is provided about such a study. This is a mechanical device, not an AI or imaging diagnostic tool that would typically involve human readers.
    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study: No information is provided about such a study. This is not an algorithm-driven device.
    7. Type of Ground Truth Used: For mechanical testing, the "ground truth" would be the measured physical properties or failure points, not expert consensus, pathology, or outcomes data. The document does not detail the specific ground truth metrics or methods used for "ultimate load," "load at 3mm," etc.
    8. Sample Size for the Training Set: Not applicable, as this is a mechanical device, not an AI system that requires a "training set."
    9. How the Ground Truth for the Training Set was Established: Not applicable.