Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K971182
    Device Name
    TOX A/B TEST
    Manufacturer
    Date Cleared
    1997-07-22

    (113 days)

    Product Code
    Regulation Number
    866.2660
    Reference & Predicate Devices
    N/A
    Why did this record match?
    Device Name :

    TOX A/B TEST

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The TOX A/B TEST is an enzyme immunoassay for the detection of toxins A and B produced by toxigenic strains of Clostridium difficile. It can be used to detect toxins A and B in fecal specimens from persons suspected of having C. difficile disease. The test is to be used as an aid in the diagnosis of C. difficile disease and results should be considered in conjunction with the patient history. FOR IN VITRO DIAGNOSTIC USE.

    Device Description

    The TOX A/B TEST is an enzyme immunoassay.

    AI/ML Overview

    The TechLab TOX A/B TEST is an enzyme immunoassay designed for the detection of toxins A and B produced by toxigenic strains of Clostridium difficile. It is intended for use with fecal specimens from individuals suspected of having C. difficile disease, serving as an aid in diagnosis, with results to be considered alongside the patient's history.

    Here is the requested information regarding the acceptance criteria and the study that proves the device meets them:

    1. Table of Acceptance Criteria and Reported Device Performance:

    Acceptance Criteria (Stated Goal)Reported Device Performance
    Specificity for toxins A and B of C. difficile (or equivalent toxins of toxigenic C. sordellii) and no reaction with non-toxigenic C. difficile or normal intestinal flora/enteric pathogens.The TOX A/B TEST is specific for toxins A and B of Clostridium difficile or the equivalent toxins of toxigenic C. sordellii. The test does not react with antigens from nontoxigenic strains of C. difficile or antigens from members of the normal intestinal flora or enteric pathogens.
    Sensitivity92%
    Specificity100%
    Predictive Positive Value100%
    Predictive Negative Value99%
    Correlation with gold standard tissue culture test> 98%
    Test completion within 1 hourCan be completed within 1 hour
    Minimizes number of steps, easy to useMinimizes the number of steps needed, making it easy to use.
    Does not require an indeterminate zoneAn indeterminate zone is not needed, thus simplifying the interpretation of test results.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document does not explicitly state the sample size used for the test set or the country of origin of the data. It also does not specify if the data was retrospective or prospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts:

    The document does not provide information on the number of experts used or their qualifications.

    4. Adjudication Method for the Test Set:

    The document does not mention any adjudication method used for the test set.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study:

    No, an MRMC comparative effectiveness study was not described. The study focuses on the performance of the device against a gold standard, not on human reader performance with or without AI assistance.

    6. Standalone Performance Study:

    Yes, a standalone (algorithm only without human-in-the-loop performance) study was performed. The reported sensitivity, specificity, predictive values, and correlation against a "gold standard" tissue culture test represent the standalone performance of the TOX A/B TEST.

    7. Type of Ground Truth Used:

    The type of ground truth used was the "gold standard" tissue culture test.

    8. Sample Size for the Training Set:

    The sample size for the training set is not mentioned in the provided text.

    9. How the Ground Truth for the Training Set Was Established:

    The document does not provide information on how the ground truth for the training set was established. It only refers to the "gold standard" tissue culture test for evaluation.