    Why did this record match?
    Device Name :

    PULSION PULSIOCATH, PULSION PCCO MONITORING KIT, PULSION IN-LINE INJECTATE SENSOR

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The PULSION Pulsiocath Thermodilution Catheter and Pressure Monitoring Kit with Injectate In-Line Sensor are intended for use with the Pulsion PiCCO Cardiac Output System for the measurement of cardiac output by the thermodilution method, measurement of arterial blood pressure, and for cardiac output determination by arterial pulse contour analysis. The Pulsion PiCCO Cardiac Output System with Thermodilution Catheter and Pressure Monitoring Kit with Injectate In-Line Sensor is indicated in patients where cardiovascular and circulatory volume status monitoring is necessary. Such as patients in surgical, medical, cardiac, and burn specialty units as well as other specialty units where cardiovascular monitorinq is desired and patients undergoing surgical interventions of such magnitude that cardiovascular monitoring is necessary.

    Device Description

    The PULSION Pulsiocath Thermodilution Catheter with J-Guidewire and needle, and a monitoring kit including an in-line injectate sensor used as accessories to the Pulsion Continuous Pulse Contour Cardiac Output System (PiCCO). When coupled with the Pulsion Continuous Pulse Contour Cardiac Output System (PiCCO), the above device accessories, in connection with a central venous catheter, operate to measure and display cardiac output parameters.

    AI/ML Overview

    The provided document is a 510(k) summary for the PULSION Pulsiocath Thermodilution Catheter with J-Guidewire and needle, and a monitoring kit including an in-line injectate sensor. This submission is for market clearance based on substantial equivalence to predicate devices, not for a de novo device requiring extensive clinical trials and performance evaluation against predefined acceptance criteria. Therefore, the document does not contain the requested information regarding acceptance criteria and a study proving the device meets them.

    Specifically:

    1. A table of acceptance criteria and the reported device performance: Not present. The document focuses on demonstrating substantial equivalence to existing devices.
    2. Sample sized used for the test set and the data provenance: Not applicable as a performance study against acceptance criteria is not described. The document pertains to substantial equivalence.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience): Not applicable.
    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set: Not applicable.
    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This device is a medical catheter and sensor system, not an AI-assisted diagnostic tool.
    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable.
    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not applicable.
    8. The sample size for the training set: Not applicable.
    9. How the ground truth for the training set was established: Not applicable.

    The submission is based on the premise that the device has the "same intended use" and "technological characteristics are the same or similar" to legally marketed predicate devices. Performance is thus inferred through equivalence, rather than a new study against specific performance criteria.