NATURAL-HIP SYSTEM COCR REVISION STEM
The Natural-Hip System CoCr Revision Stem is intended to replace the anatomy of the femur in cases of total hip or hemi-hip replacement. The Natural-Hip System CoCr Revision Stem is intended for cemented application only and is intended for single use only. The Natural-Hip System CoCr Revision Stem is intended for use in treatment of the following: Patient conditions of non-inflammatory degenerative joint disease (NIDJD), e.g., avascular necrosis, osteoarthritis and inflammatory joint disease (IJD), e.g., rheumatoid arthritis. Those patients with failed previous surgery where pain, deformity or dysfunction persists. Revision of previously failed arthroplasty.
The Natural-Hip System CoCr Revision Stem is fabricated from either forged or wrought cobalt chromium alloy which conforms to the American Standards for Testing and Materials (ASTM) standards F-799 or F-1537, respectively. The Natural-Hip System CoCr Revision Stem features a threaded Sulzer 12/14 configured neck trunnion for attachment to IOI's currently marketed femoral heads, including Biolox and Zirconia heads, employing a Sulzer 12/14 configured bore. The Natural-Hip System CoCr Revision Stem is available in both a collared and collarless design. The proximal one-third of the stem's surface employs normalization steps and is roughened via the process of grit blasting. The normalization steps and grit blasted surface enhance cement compression and bonding for optimal fixation of the hip stem in the femoral canal. The proximal surface of the Natural-Hip System CoCr Revision Stem also employs polymethylmethacrylate (PMMA) cement centralizers to provide even cement mantle when the stem is implanted in the femur. The distal portion of the Natural-Hip System CoCr Revision Stem is bowed to mimic the anatomy of the femur. The Natural-Hip System CoCr Revision Stem employs a hole in the distal portion of the stem to allow the use of a PMMA centralizer for correct distal alignment.
This is a 510(k) summary for a medical device, specifically a hip joint replacement component. It does not describe any AI/ML device or software, therefore, it does not contain information about acceptance criteria or studies related to AI/ML device performance.
The document discusses the physical characteristics, intended use, and predicate devices for a "Natural-Hip™ System CoCr Revision Stem." It is purely about the hardware of a hip implant.
Therefore, I cannot provide the requested information about acceptance criteria, study details, sample sizes, expert qualifications, adjudication methods, MRMC studies, or ground truth establishment because this document does not pertain to an AI/ML device.