    FaSet Fixation System, UNITY Sacroiliac Joint Fixation System, Huvex Interspinous Fixation System, and

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The FaSet Fixation System is intended to stabilize the spine as an aid to fusion through bilateral immobilization of facet joints. The Facet Screw System is indicated for posterior surgical treatment with or without bone graft at single or multiple levels from C2 to S1 (inclusive). For transfacet fixation, the screws are inserted posteriorly through the superior side of the facet, across the facet joint, and into the pedicle. For translaminar facet fixation, the screws are inserted posteriorly through the lateral aspect of the spinous process, through the lamina, through the superior side of the facet, across the facet joint, and into the pedicle. The FaSet Fixation System is indicated for treatment for any or all of the following:

    • Spondylolisthesis
    • Pseudoarthrosis or failed previous fusions which are symptomatic, or which may cause secondary instability or deformity
    • Spondylolysis
    • Degenerative Disk Disease (DDD) as defined by back pain of discogenic origin with degeneration of disk confirmed by history and radiographic studies and/or degenerative disease of the facets with instability
    • Trauma including spinal fractures and/or dislocations.

    The UNITY Sacroiliac Joint Fixation System is indicated for sacroiliac joint fusion for:

    • Sacroiliac joint dysfunction including degenerative sacroiliitis and sacroiliac joint disruptions
    • Augmenting immobilization and stabilization of the sacroiliac joint in skeletally mature patients undergoing sacropelvic fixation as part of a lumbar or thoracolumbar fusion

    The UNITY Sacroiliac Joint Fixation System is also indicated for fracture fixation of acute, non-acute, and non-traumatic fractures involving the sacroiliac joint.

    The Huvex Interspinous Fixation System is a posterior, non-pedicle supplemental fixation device intended for use in the lumbar spine (T1-S1) as an adjunct to fusion in skeletally mature patients. It is intended for plate fixation/attachment to the spinous processes for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), tumor, and/or lumbar spinal stenosis. The Huvex Interspinous Fixation System is intended for use, in conjunction with autogenous bone graft, and not intended for stand-alone use.

    The AEON-C™ Stand Alone System is a stand-alone anterior cervical intervertebral fusion device indicated for use in skeletally mature patients with degenerative disc disease (DDD) with accompanying radicular symptoms at one or two contiguous levels from C2-T1. DDD is defined as discogenic pain with degeneration of the disc confirmed by history and radiographic studies. The AEON-C™ Stand Alone System should be packed with autograft and/or allograft comprised of cancellous, cortical and/or corticocancellous bone graft and implanted with an anterior approach. Patients should receive at least six (6) weeks of non-operative treatment prior to treatment with a cervical intervertebral fusion device. If the device is being used without the provided screws, supplemental fixation must be used.

    Device Description

    The FaSet Fixation System consist of permanent implant devices manufactured from titanium or titanium alloy (Ti-6Al-4V ELI) as specified in ASTM F67, and F136. Various sizes and lengths of these implants are available to accommodate patient anatomy. The device is intended to provide mechanical support and stability to the implanted level until biologic fusion is achieved.

    The UNITY Sacroiliac Joint Fixation System consists of screws designed to enhance sacroiliac joint fusion. The UNITY Sacroiliac Joint Fixation System is offered in various diameters, lengths, and three screw types in cannulated form to accommodate patient anatomy and is manufactured from titanium alloy (Ti-6Al-4V ELI) as specified in ASTM F136 and cobalt chrome alloy as specified in ASTM F1537. The three design types of the subject device are:

      1. Standard Thread Screw (with and without slots)
      1. Lag Screw (with and without slots) and
      1. Washer Screw (with slots)

    The Huvex Interspinous Fixation System consists of a left plate, a right plate, pin, bolt, inner cap, center bar, and set screw. Each of these components is provided in several sizes to allow for the construction of five different HUVEX Interspinous Fusion implant sizes. The left plate is provided assembled with the poly axial bar. The bar has a bone graft window to allow fusion between spinous process. Poly axial bar is also designed to fit the anatomical characteristics of the spinous process. The right plate is designed to be combined with left plate fixed to spinous process. Right plate contains a set screw to lock the right plate to the poly axial bar. The Huvex Interspinous Fixation System components are supplied non-sterile, are single use and are fabricated from titanium alloy (Ti-6AI-4V ELI) that conforms to ASTM F136.

    In addition to the implants a set of reusable surgical instruments are provided. Both implant and instruments have trays that are used for handling and storage.

    The AEON-C™ Stand Alone System includes PEEK interbodies and titanium interbodies, which utilize a titanium alloy locking mechanism that is either integrated in an anterior fixation plate or within the interbody. Both PEEK interbodies and titanium interbodies, with or without fixation plates, are to be anchored to patient anatomy via two (2) titanium alloy bone screws. The implant design includes multiple footprints, heights and lordosis options and the screw design includes multiple diameters and lengths, to fit a variety of patient anatomies. The interbodies can be used without the provided screws when supplemental fixation is used.

    AI/ML Overview

    The provided document is a 510(k) summary for several medical devices: FaSet Fixation System, UNITY Sacroiliac Joint Fixation System, Huvex Interspinous Fixation System, and AEON-C™ Stand Alone System.

    This document describes that the subject devices are substantially equivalent to their predicate devices, which means they are considered as safe and effective as a legally marketed device that does not require premarket approval.

    Here's an analysis based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    This document does not contain specific quantitative acceptance criteria or reported device performance metrics in the way one would typically see for a novel diagnostic or AI-driven decision support system. Instead, the devices are cleared based on substantial equivalence to predicate devices.

    The "Performance Data" section states:

    • "The K&J Consulting - FaSet Fixation System, Huvex Interspinous Fixation System, and AEON-C™ Stand Alone System devices are identical to predicate devices and therefore, no performance testing is required."
    • "New components being added to the UNITY Sacroiliac Joint Fixation System, but the new components do not introduce a new mechanical worst-case, so no new testing is required."

    Therefore, there is no table presenting acceptance criteria and reported device performance because the regulatory clearance is based on the devices being identical or having similar technological characteristics and not introducing new safety/effectiveness concerns compared to previously cleared devices.

    2. Sample Size Used for the Test Set and Data Provenance

    Since no new performance testing was required due to substantial equivalence, there is no test set sample size or data provenance mentioned in this document for the subject devices.

    3. Number of Experts Used to Establish Ground Truth and Their Qualifications

    Given that performance testing was not required for these devices (as they are identical or technologically similar to predicates), there is no mention of experts or ground truth establishment in this context.

    4. Adjudication Method

    No adjudication method is mentioned as there was no performance testing involving human review of a test set.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No MRMC study was conducted or reported for these devices. The devices are hardware implants, not AI-driven systems where such studies are typically performed.

    6. Standalone (Algorithm Only) Performance Study

    Not applicable. These are physical implantable devices, not algorithms.

    7. Type of Ground Truth Used

    No ground truth data was used for the substantial equivalence determination beyond the specifications and established safety/effectiveness profiles of the predicate devices.

    8. Sample Size for the Training Set

    Not applicable. These are physical implantable devices, not AI/ML algorithms that require a training set.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K162849
    Date Cleared
    2017-02-16

    (128 days)

    Product Code
    Regulation Number
    888.3050
    Reference & Predicate Devices
    Why did this record match?
    Device Name :

    Huvex Interspinous Fixation System

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Huvex Interspinous Fixation System is a single-level, posterior, non-pedicle supplemental fixation device intended for use in the non-cervical spine (TI-S1) as an adjunct to fusion in skeletally mature patients. It is intended for plate fixation/ attachment to the spinous processes for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), and/or tumor. The Huvex Interspinous Fixation System is intended for use at one level, in conjunction with autogenous bone graft, and not intended for stand-alone use.

    Device Description

    The Huvex Interspinous Fixation System consists of a left plate, a right plate, pin, bolt, inner cap, center bar, and set screw. Each of these components is provided in several sizes to allow for the construction of five different Huvex Interspinous Fixation implant sizes. The left plate is provided assembled with the poly axial bar. The bar has a bone graft window to allow fusion between spinous process. Poly axial bar is also designed to fit the anatomical characteristics of the spinous process. The right plate is designed to be combined with left plate fixed to spinous process. Right plate contains a set screw to lock the right plate to the poly axial bar. The Huvex Interspinous Fixation System components are supplied non-sterile, are single use and are fabricated from titanium alloy (Ti-6AI-4V ELI) that conforms to ASTM F 136. In addition to the implants a set of reusable surgical instruments are provided.

    AI/ML Overview

    The provided document is a 510(k) summary for the Huvex Interspinous Fixation System. It describes the device, its intended use, and that performance testing was conducted to demonstrate substantial equivalence to predicate devices. However, the document does not describe acceptance criteria, the specific study design to prove acceptance criteria were met, or detailed performance results in the format requested.

    It states general categories of tests performed but lacks the quantitative details needed to answer all parts of your request.

    Here's a breakdown of what can be extracted and what is missing:

    1. Table of Acceptance Criteria and Reported Device Performance

    Not available in the provided document. The document states:

    • "Static & Dynamic compression, Static torsion, and Static tension testing in accordance with a modified ASTM F1717 setup"
    • "Static grip testing with a modified ASTM F1798 setup"
    • "were conducted to demonstrate substantial equivalence to the predicate system(s)."

    It does not provide specific acceptance criteria values (e.g., maximum deflection, fatigue cycles survived, ultimate load) or the quantitative performance results (e.g., "Device A survived X cycles," or "Device A withstood Y N of compression"). It only indicates that these tests were performed and deemed sufficient for substantial equivalence.

    2. Sample Size Used for the Test Set and Data Provenance

    Not available in the provided document. The document does not specify the number of samples (implants) used for each mechanical test. Data provenance (country of origin, retrospective/prospective) is not relevant for mechanical bench testing of an implant; these tests are typically conducted in a lab environment.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    Not applicable. This question pertains to clinical studies involving human interpretation or pathology. The provided document describes mechanical bench testing of a medical implant, not a diagnostic device or a clinical study that requires expert ground truth establishment.

    4. Adjudication Method for the Test Set

    Not applicable. This question relates to clinical studies and expert review for ground truth, not mechanical bench testing.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    Not applicable. This type of study is relevant for diagnostic imaging devices where human readers interpret results, often with and without AI assistance. The Huvex Interspinous Fixation System is a surgical implant, and no MRMC study would be performed for its clearance.

    6. Standalone Performance Study

    The document describes standalone mechanical performance testing as part of its substantial equivalence claims. The tests mentioned (Static & Dynamic compression, Static torsion, Static tension, Static grip) are performed on the device itself (or device constructs) without a human in the loop. The "performance and SE determination" section says, "The Huvex Interspinous Fixation System has been demonstrated to be substantially equivalent to the predicate system(s) with respect to technical characteristics, performance, and intended use." This implies that the device's mechanical performance, in isolation, was evaluated against established standards or predicate device performance.

    However, specific quantitative results from these standalone tests are not provided in this summary.

    7. Type of Ground Truth Used

    Not applicable in the sense of clinical ground truth. For mechanical testing, the "ground truth" or reference is typically defined by:

    • ASTM standards: ASTM F1717 (Standard Test Methods for Spinal Implant Constructs in a Corpectomy Model) and ASTM F1798 (Standard Guide for Evaluation of Static and Fatigue Properties of Interconnection Mechanisms and Subassemblies Used in Spinal Arthrodesis Constructs) are mentioned, albeit as "modified" setups. These standards define the methodology for testing.
    • Predicate device performance: The goal is to demonstrate "substantial equivalence" to predicate devices, meaning the device performs comparably mechanically. The performance of the predicate device acts as the benchmark.

    8. Sample Size for the Training Set

    Not applicable. Surgical implants undergo mechanical testing, not algorithm training using a "training set" of data in the AI sense.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. As above, there is no "training set" for this type of device and evaluation.

    In summary: The provided 510(k) summary focuses on demonstrating substantial equivalence through mechanical bench testing. It lists the types of tests conducted and the standards referenced but does not provide the quantitative acceptance criteria or specific performance results that would directly answer your request in detail.