    K192278
    Device Name
    Luminelle DTx Hysteroscopy System, Luminelle Dx 360 Rotatable Disposable Sheath (Diagnostic)
    Manufacturer
    UVision360 Inc.
    Date Cleared
    2019-11-01

    (71 days)

    Product Code
    HIH, FAJ
    Regulation Number
    884.1690
    Why did this record match?
    Applicant Name (Manufacturer) :

    UVision360 Inc.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Hysteroscopy: The LUMINELLE DTx Hysteroscopy System is used to permit viewing of the cervical canal and uterine cavity for the purpose of performing diagnostic and surgical procedures. NOTE: Hysteroscopes are used as tools to access the uterine cavity and are not, in and of themselves, a method of surgery. When LUMINELLE DTx Hysteroscopy System is specifically used with the LUMINELLE Dx 360 Rotatable Disposable Sheath (Diagnostic), the system is limited to performing diagnostic procedures only. Generally recognized indications for diagnostic hysteroscopy include: - Abnormal bleeding - Infertility and pregnancy wastage - Evaluation of abnormal hysterosalpingogram - Intrauterine foreign body - Amenorrhea - Pelvic Pain Generally recognized indications for use for operative hysteroscopy include: - Directed endometrial biopsy - Polypectomy - Submucous myomectomy - Transection of intrauterine adhesions - Transection of intrauterine septa - Endometrial ablation Cystoscopy: The LUMINELLE DTx Hysteroscopy System is intended for use in endoscopic access to and examination of the lower urinary tract, including the blader. When combined with accessory instruments, the user to perform various diagnostic and therapeutic procedures. NOTE: When LUMINELLE DTx Hysteroscopy System is specifically used with the LUMINELLE Dx 360 Rotatable Disposable Sheath (Diagnostic), the system is limited to performing diagnostic procedures only.
    Device Description
    The LUMINELLE DTx Hysteroscopy System originally received 510(k) clearance in 2018 as a hvsteroscopic and cvstoscopic svstem (K181909). In addition, LUMINELLE DTx Hysteroscopy System received 510(k) clearance in 2019 for the addition of a sheath component, LUMINELLE DTx 360° Rotatable Disposable Sheath Rigid to the system (K190827). Based on user feedback for a thinner option for the disposable sheath for only diagnostic use, UVision360, Inc. (hereafter UVision) proposes the addition of a new accessory, the LUMINELLE Dx 360° Rotatable Disposable Sheath (Diagnostic), as part of an engineering performance change. The LUMINELLE DTx Hysteroscopy System indications for use is identical to the previously cleared indications for use for the system. However, when the system is used with the LUMINELLE Dx 360° Rotatable Disposable Sheath (Diagnostic), the indications for use are limited to diagnostic use only. No changes are proposed for the previously cleared components of the LUMINELLE DTx Hysteroscopy System. The new LUMINELLE Dx 360° Rotatable Disposable Sheath (Diagnostic) accessory is a modification of the LUMINELLE DTx 360° Rotatable Disposable Sheath Rigid component of the previously cleared LUMINELLE DTx Hysteroscopy System (K190827) with the following main changes: - . The new accessory has one fluid line rather than the two fluid lines of the previously cleared component. - . The new accessory has a combined channel for the scope and the fluid line rather than the separate channels of the previously cleared component. - The new accessory has no operative channel available unlike the previously cleared . component, due to the fact that it is for diagnostic use only.
    Ask a Question
    K Number
    K190827
    Device Name
    Luminelle DTx Hysteroscopy System, Luminelle 360 Rotatable Sterile Disposable Sheath Rigid
    Manufacturer
    UVision360 Inc.
    Date Cleared
    2019-06-06

    (66 days)

    Product Code
    HIH, FAJ
    Regulation Number
    884.1690
    Why did this record match?
    Applicant Name (Manufacturer) :

    UVision360 Inc.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Hysteroscopy: The LUMINELLE DTx Hysteroscopy System is used to permit direct viewing of the cervical canal and uterine cavity for the purpose of performing diagnostic and surgical procedures. Note: Hysteroscopes are used as tools to access the uterine cavity and of themselves, a method of surgery. Generally recognized indications for diagnostic hysteroscopy include: - Abnormal bleeding - Infertility and pregnancy wastage - Evaluation of abnormal hysterosalpingogram - Intrauterine foreign body - Amenorrhea - Pelvic pain Generally recognized indications for operative hysteroscopy include: - Directed endometrial biopsy - Polypectomy - Submucous myomectomy - Transection of intrauterine adhesions - Transection of intrauterine septa - Endometrial ablation Cystoscopy: The LUMINELLE DTx Hysteroscopy System is intended for use in endoscopic access to and examination of the lower urinary tract, including the bladder. When combined with accessory instruments, the user to perform various diagnostic and therapeutic procedures.
    Device Description
    The LUMINELLE DTx Hysteroscopy System previously received 510(k) clearance (K181909) in 2018 as a hysteroscopic and cystoscopic system. To provide the user with a more rigid option for the RotoSheath and Introducer, UVision360, Inc. (hereafter UVision) proposes the addition of a new component to the system, the LUMINELLE DTx 360° Rotatable Disposable Sheath Rigid in addition to the currently available flexible Rotatable Disposable Sheath option cleared during the previous submission (K181909). No changes are proposed for the previously cleared components or the principles of operation of the LUMINELLE DTx Hysteroscopy System. The proposed change includes only the addition of a new component which is a modification to the previously cleared flexible LUMINELLE DTx 360° Rotatable Disposable Sheath.
    Ask a Question
    K Number
    K181909
    Device Name
    Luminelle DTx Hysteroscopy System
    Manufacturer
    UVision360 Inc.
    Date Cleared
    2018-08-16

    (30 days)

    Product Code
    FAJ, HIH
    Regulation Number
    876.1500
    Why did this record match?
    Applicant Name (Manufacturer) :

    UVision360 Inc.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    Hysteroscopy: The Luminelle DTx Hysteroscopy System is used to permit direct viewing of the cervical canal and uterine cavity for the purpose of performing diagnostic and surgical procedures. Note: Hysteroscopes are used as tools to access the uterine cavity and of themselves, a method of surgery. Generally recognized indications for diagnostic hysteroscopy include: - Abnormal bleeding - Infertility and pregnancy wastage - · Evaluation of abnormal hysterosalpingogram - · Intrauterine foreign body - · Amenorrhea - · Pelvic pain Generally recognized indications for operative hysteroscopy include: - · Directed endometrial biopsy - · Polypectomy - Submucous myomectomy - · Transection of intrauterine adhesions - · Transection of intrauterine septa - · Endometrial ablation Cystoscopy: The Luminelle DTx Hysteroscopy System is intended for use in endoscopic access to and examination of the lower urinary tract, including the bladder. When combined with accessory instruments, the System allows the user to perform various diagnostic and therapeutic procedures.
    Device Description
    The Luminelle DTx Hysteroscopy System is comprised of four components: 1) Luminelle DTx Hysteroscope - a non-sterile, reusable flexible hysteroscope with an integrated light source, light fiber bundle and CMOS sensor. 2) The Luminelle DTx 360° Rotatable Disposable Sheath - a sterile, two-part sheath installed over the insertion tube of the Hysteroscope and comprised of the Operative Introducer and the 360° RotoSheath. The Operative Introducer contains an operative channel for inserting surgical accessories, two fluid management lines (inflow/outflow), and a channel to protect the scope insertion tube. The 360° RotoSheath allows for rotational positioning of the camera and provides rigidity to the Scope/Introducer assembly. 3) Luminelle Communication Cable - a cable that provides both the power to the hysteroscope and transmits the image. 4) Luminelle Control Hub - the main power supply, image converter and visualization connection. The Control Hub has both HDMI and USB connectors for connection to a monitor and/or a PC. USB and HDMI cables are provided in the package. The Luminelle DTx Hysteroscope, Communication Cable, Control Hub, USB and HDMI cables and power cord are provided together in a single package. The 360° Rotatable Disposable Sheath is provided in a separate sterile package. The 360º Rotatable Disposable Sheath is required for use with the Hysteroscope, therefore it is a component of the system and not an accessory to the system. The CMOS sensor and fiber optic illumination bundles are contained in the Hysteroscope Insertion Tube. The insertion tube length is 29.8 cm (11.73 in.) and the outside diameter is 1.95 mm (0.077 in.). The Luminelle DTx Hysteroscope is packaged in a white form fit tray with a clear slide-on cover. The tray is made of high-impact polystyrene (HIPS). The clear cover is made of polyethylene terephthalate with glycol (PETG). The Luminelle 360° RotoSheath has a working length of 24.0 cm (9.45 in.) with an outside diameter of 5.7 mm (0.244 in.). The Luminelle Operative Introducer has an outside diameter of 4.8 mm (0.189 in.) and the inside diameter of the operative channel is 1.85 mm (0.073 in.). Both the Luminelle 360º RotoSheath and Luminelle Operative Introducer are supplied as a single assembled unit packaged in a bottom tray with retaining lid made of polyethylene terephthalate with glycol (PETG) and sealed with Tyvek. The assembled package is sterilized using ethylene oxide (EO). The Control Hub supplies power to the Hysteroscope via a reusable Communication Cable. The CMOS sensors have a processor that converts the visual image into data to be transferred. A processor in the Control Hub converts this image data into streaming HDMI language, takes still images when the button is pushed, and also controls the light exposure during changing light conditions. Visualization on a video monitor is provided via a HDMI cable, and image transfer to a PC is provided via a Type A USB cable. A 12V DC, 3A power adapter is also provided. Technical specifications for these reusable components are provided in the Instructions for Use.