510(k) Data Aggregation

    K Number
    K222701
    Device Name
    MANTA Laser
    Manufacturer
    SQUALUS MED Ltd.
    Date Cleared
    2022-11-18

    (72 days)

    Product Code
    GEX
    Regulation Number
    878.4810
    Why did this record match?
    Applicant Name (Manufacturer) :

    SQUALUS MED Ltd.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
    Intended Use
    The MANTA810 diode laser is indicated for use in surgical applications requiring the vaporization, incision, ablation, cutting and hemostasis, or coagulation of soft tissue in conjunction with endoscopic equipment for medical specialist including: Urology, Thoracic Surgery, Plastic Surgery and Dermatology, General Surgery, Ophthalmology, Orthopedics, Podiatry, Arthroscopy, Spinal Surgery, Cyneology, Pulmonary Surgery, Neurosurgery, Gastroenterology, Head/neck/ENT and Radiology, Oral Surgery and Dental procedures. The MANTA980 diode laser is indicated for use in surgical application, incision, incision, excision, ablation, cutting and hemostasis, or coagulation of soft tissue in conjunction with endoscopic equipment for medical specialist including: Urology, Thoracic Surgery, Plastic Surgery and Dermatology, General Surgery, Ophthalmology, Orthopedics, Podiatry, Arthroscopy, Spinal Surgery, Gynecology, Pulmonary Surgery, Neurosurgery, Gastroenterology, Head/neck/ENT and Radiology, Oral Surgery and Dental procedures. The MANTA1064 diode laser is indicated for use in surgical applications requiring the vaporization, incision, ablation, cutting and hemostasis, or coagulation of soft tissue in conjunction with endoscopic equipment for medical specialist including: Urology, Thoracic Surgery, Plastic Surgery and Dermatology, General Surgery, Ophthalmology, Orthopedics. Podiatry, Arthroscopy, Spinal Surgery, Gyneology, Pulmonary Surgery, Gastroenterology, Head/neck/ENT and Radiology, Oral Surgery and Dental procedures. The MANTA1470 diode laser is indicated for use in surgical applications requiring the vaporization, incision, ablation, cutting and hemostasis, or coagulation of soft tissue in conjunction with endoscopic equipment for medical specialist including: Urology, Thoracic Surgery, Plastic Surgery and Dermatology, General Surgery, Ophthalmology, Orthopedics, Podiatry, Arthroscopy, Spinal Surgery, Gynecology, Pulmonary Surgery, Neurosurgery, Gastroenterology, Head/neck/ENT and Radiology, Oral Surgery and Dental procedures. The MANTA1940 diode laser is indicated for use in surgical applications requiring the vaporization, incision, ablation, cutting and hemostasis, or coagulation of soft tissue in conjunction with endoscopic equipment for medical specialist including: Urology, Thoracic Surgery, Plastic Surgery and Dermatology, General Surgery, Ophthalmology, Orthopedics, Podiatry, Arthroscopy, Spinal Surgery, Gyneology, Pulmonary Surgery, Gastroenterology, Head/neck/ENT and Radiology, Oral Surgery and Dental procedures.
    Device Description
    The MANTA diode lasers are a family of products with a laser diode as the beam source. Dependent on the chosen diode, the laser system can radiate one factory set wavelength with any of the following: 810nm, 980nm, 1064nm, 1470nm or 1940nm. The MANTA is a compact diode laser with a high-resolution color touchscreen for user control.
    Ask a Question

    Page 1 of 1