    K Number
    K101947
    Device Name
    IVD-GE02
    Date Cleared
    2011-03-16

    (247 days)

    Product Code
    Regulation Number
    862.1345
    Why did this record match?
    Applicant Name (Manufacturer) :

    SPHERE MEDICAL LTD.

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdparty
    Intended Use
    The IVD-GE02 system is a blood gases analyzer intended as an in vitro diagnostic device for the quantitative measurement of whole blood samples in a clinical laboratory. The IVD-GE02 system includes sensors for the measurement of pH, pCO2, pO2, potassium and glucose. pH, pCO2, pO2: Measurement of blood gases (pCO2, pO2) and blood pH are used in the diagnosis and treatment of life-threatening acid-base disturbances. Potassium: Measurement of potassium are used to monitor electrolyte balance in the diagnosis and treatment of disease conditions characterized by high or low potassium levels. Glucose: Measurement of glucose is used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathetic hypoglycaemia and of pancreatic islet cell carcinoma. IVD-GE02 calibration solutions are in vitro diagnostic products for the calibration of the IVD-GE02 test system for the measurements of pH, pCO2, pO2, potassium and glucose.
    Device Description
    The IVD-GE02 system is an in-vitro diagnostic device for the determination of specified analytes in blood using electrochemical principles. The IVD-GE02 is essentially a modular system consists of the following components .- - A dedicated combined PC and monitor with a touch screen . - · A disposable cartridge containing - o Sensor - o Electronic circuitry, including an ASIC (Application Specific Integrated Circuit), to process sensor signals and drive the fluid management system. - ◆ An instrument containing - o Fluid management components (tubing, pumps and valves) - o The cartridge (see above) - o An injection port for samples, calibration solutions and QC solutions - o Wiring to connect the cartridge to the fluid management components - Syringes with calibration solutions packed in sealed foil bags . - Containers with flush solutions ◆ ◆ - A waste container - A dedicated printer and associated cables - An ambient temperature and pressure sensor - Cables to connect the monitor to the instrument and a power supply unit - Packaging - Label Copy
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1