K Number
K182713Device Name
Scoreflex PTA Scoring Balloon Catheter
Manufacturer
Date Cleared
2019-06-11
(257 days)
Product Code
Regulation Number
870.1250Why did this record match?
Applicant Name (Manufacturer) :
OrbusNeich Medical Trading, Inc.
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdparty
Intended Use
The Scoreflex PTA Scoring Balloon Catheter is indicated for Percutaneous Transluminal Angioplasty in the peripheral vasculature, including iliac, femoral, poplited, infra-popliteal, and renal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. This device is also indicated for treatment of instent restenosis of balloon expandable and self-expanding stents in the peripheral vasculature.
Device Description
The Scoreflex PTA Scoring Balloon Catheter is designed for easy guidewire exchange and available with balloon diameters of 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0, 5.5, and 6.0mm, balloon lengths of 15, 20 and 40mm and a catheter working length of 40, 90, or 150cm. There are two catheter designs within the Scoreflex family: the no-coil design has a smaller shaft profile than the corresponding coil design catheter of the same balloon configuration which will allow for access to more distal lesions while the coil design minimizes balloon curvature during inflation. The balloon is made of a semi-complaint material with a rated burst pressure of 14 atmospheres. The proximal shaft of the catheter is composed of a female luer connector bonded to a nylon jacketed stainless steel hypotube and the scoring wire is laser welded to the distal end of the hypotube. The proximal shaft joins with a smooth transition to the distal shaft (composed of an outer nylon tube with the balloon/tip tube and scoring wire welded at the distal tip). The cutting section of the scoring wire is outside of the balloon. Two radiopaque platinum/iridium marker bands are located on the scoring wire and aligned with the balloon shoulders to ensure accurate positioning of the balloon. The tip lumen is compatible with either a standard 0.014 inch (0.36mm) or 0.018 inch (0.46mm) guidewire. The guidewire enters the catheter tip and advances coaxially out the Rx port, thereby allowing both coaxial guidance and rapid exchange of catheter with a single standard length guidewire. The design of this dilatation catheter does not incorporate a lumen for distal dye injections or distal pressure measurements. The catheter is lubricated with hydrophilic coating on the tip and the distal outer body surface; the tip lumen and the balloon are lubricated with silicone coating.
Ask a Question
Ask a specific question about this device
Page 1 of 1