Search Results
Found 19 results
510(k) Data Aggregation
K Number
K240250Device Name
3D Printed PEEK Interbody System
Manufacturer
Nvision Biomedical Technologies, Inc.
Date Cleared
2024-09-17
(231 days)
Product Code
MAX, ODP
Regulation Number
888.3080Why did this record match?
Applicant Name (Manufacturer) :
Nvision Biomedical Technologies, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The 3D Printed PEEK Interbody System (ALIF) is intended for spinal fusion procedures in the lumbosacral spine at one or two contiguous levels from L2 to S1 in skeletally mature patients with degenerative disc disease (DDD). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six months of non-operative treatment prior to treatment with an intervertebral body fusion device. These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s). DDD patients may also have Grade 1 spondylolisthesis or retrolisthesis at the involved levels. The device must be used with supplemental fixation and is intended for use with autograft and/or allogenic bone graft composed of cancellous and/or corticocancellous bone graft. The device is to be implanted via an anterior approach.
The 3D Printed PEEK Interbody System (Cervical) is intended for spinal fusion procedures in the cervical spine at one or two contiguous levels from C2 to T1 in skeletally mature patients with degenerative disc disease (DDD). DDD is defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. These patients should have had six weeks of non-operative treatment prior to treatment with an intervertebral body fusion device. These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s). The device must be used with supplemental fixation and is intended for use with autograft and/or allogenic bone graft composed of cancellous and/or corticocancellous bone graft. The device is to be implanted via an anterior approach.
Device Description
The 3D Printed PEEK Interbody System devices are spinal fusion implants that are inserted into the intervertebral body space of the spine to act as disc spacers and hold bone graft. These devices are manufactured from PEEK OPTIMA™ LT1AMR5 with tantalum radiographic markers and are offered in multiple footprint, height, and lordotic angle options.
Ask a Question
K Number
K231453Device Name
SnapHammer Hammertoe Correction System
Manufacturer
Nvision Biomedical Technologies, Inc
Date Cleared
2024-02-16
(274 days)
Product Code
HWC, CLA, HTY
Regulation Number
888.3040Why did this record match?
Applicant Name (Manufacturer) :
Nvision Biomedical Technologies, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The SnapHammer Hammertoe Correction System is indicated for the fixation of osteotomies and reconstruction of the lesser toes following correction procedures for hammertoe, claw toe, and mallet toe. Cannulated implants in the SnapHammer Hammertoe Correction System can be used with K-wires for the delivery of implants or the temporary stabilization of outlying joints (e.g. MTP Joint).
Device Description
The SnapHammer Hammertoe Correction System is comprised of an additively manufactured titanium fixation device attached to a snap-off post. The snap-off post aids in a quick insertion and snaps off after implant has been threaded in. The implants are offered in Ø3.0mm and Ø3.50mm diameters and in lengths ranging from 12mm. The system includes drills, implant inserters, and sizers manufactured from medical grade stainless steel.
Ask a Question
K Number
K230853Device Name
EARP Nerve Cuff Electrode
Manufacturer
Nvision Biomedical Technologies, Inc.
Date Cleared
2023-10-06
(192 days)
Product Code
ETN, CLA
Regulation Number
874.1820Why did this record match?
Applicant Name (Manufacturer) :
Nvision Biomedical Technologies, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The EARP Nerve Cuff Electrode is used to perform localized stimulation of neural tissue and to locate, identify, and monitor spinal nerve roots during surgery.
Device Description
The EARP Nerve Cuff Electrode conducts electrical signal as a component of intraoperative neuromonitoring. The EARP Nerve Cuff Electrode is used with commercially available neuromonitoring systems and does not stimulate or record signal itself. The standard connectors at the proximal end of the EARP Nerve Cuff Electrode interface with the neuromonitoring equipment and the distal cuff contacts the target tissue. The EARP Nerve Cuff Electrode is provided sterile packaged and is for single use only.
Ask a Question
K Number
K222015Device Name
Integral Titanium Cervical Interbody
Manufacturer
Nvision Biomedical Technologies, Inc
Date Cleared
2023-07-05
(362 days)
Product Code
ODP
Regulation Number
888.3080Why did this record match?
Applicant Name (Manufacturer) :
Nvision Biomedical Technologies, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Integral Titanium Cervical Interbody is intended for spinal fusion procedures at one level, from C2-T1, in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine. DDD is defined as back pain of discogenic origin with the degeneration of the disc confirmed by history and radiographic studies. One device is to be used per intervertebral space. Patients should receive six weeks of non-operative treatment prior to treatment with an intervertebral body fusion device. The Integral Titanium Cervical Interbody devices must be used with supplemental fixation and are designed for use with autograft bone to facilitate fusion. The devices are to be implanted via an anterior approach.
Device Description
The Integral Titanium Cervical Interbody is an intervertebral body fusion device used in the cervical spine following discectomy. All devices are additively manufactured using titanium alloy per ASTM F3001.
The devices have multiple footprints to adapt to the general shape of the vertebral endplates and have a hollow center to accommodate bone graft. The devices are implanted via an anterior (ACIF) surgical approach. Each footprint is available in multiple heights to accommodate patient variability and there are anti-migration features on the superior and inferior surfaces designed to improve fixation, stability and prevent back out.
Ask a Question
K Number
K223226Device Name
Trigon HA Stand-Alone Wedge Fixation System
Manufacturer
Nvision Biomedical Technologies, Inc.
Date Cleared
2022-12-01
(44 days)
Product Code
PLF, HWC
Regulation Number
888.3030Why did this record match?
Applicant Name (Manufacturer) :
Nvision Biomedical Technologies, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Trigon HA Stand-Alone Wedge Fixation System is intended to be used for internal bone fixation for bone fractures or osteotomies in the ankle and foot, such as:
- · Cotton (opening wedge) Osteotomies of the Medial Cuneiform
- · Evans Lengthening Osteotomies
- · Subtalar Fusion
- · First Metatarsal-Cuneiform Lengthening Arthrodesis
- Calcaneocuboid Arthrodesis
The Trigon HA wedges are intended for use with ancillary fixation.
The Trigon HA Stand-Alone Wedge Fixation System is not intended for use in the spine.
Device Description
The Trigon HA Stand-Alone Wedge Fixation System is a family of PEEK Optima HA Enhanced (HA PEEK) wedges with tantalum markers used for angular correction of small bones of the foot. The wedges incorporate two screw-receiving holes, surface teeth, and an area to contain grafting material. The wedges are designed in rectangular, kidney, circular oval and teardrop shaped footprints in a range of sizes and in multiple thicknesses. The associated 2.5mm diameter titanium screws are designed in lengths of 10 to 30mm.
When used with the provided screw fixation the Trigon wedges may be used with or without ancillary plating, except for the Lapidus and Calcaneocuboid Wedges which will require ancillary fixation not provided in the Trigon System. When used without the provided screws, Trigon wedges are intended for use with ancillary fixation.
Ask a Question
K Number
K212477Device Name
EARP Interbody System
Manufacturer
Nvision Biomedical Technologies, Inc.
Date Cleared
2022-04-28
(262 days)
Product Code
MAX, CLA
Regulation Number
888.3080Why did this record match?
Applicant Name (Manufacturer) :
Nvision Biomedical Technologies, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The EARP Interbody System is intervertebral body fusion in the lumbar spine in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels from L2 to S1 of the lumbosacral spine. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radios. These patients should have had six months of non-operative treatment with an intervertebral cage. DDD patients may also have Grade 1 spondylolisthesis at involved levels. The device system must be used with supplemental fixation and autograft to facilitate fusion and is implanted via a posterolateral approach.
Device Description
EARP implants are intervertebral body fusion devices used in the lumbar spine following discectomy. All devices are manufactured from PEEK Optima LT1 per ASTM F2026 and include tantalum markers per ASTM F560 for radiographic visualization. The devices have multiple footprints to adapt to the general shape of the vertebral endplates and have a hollow center to accommodate bone graft. Each footprint is available in multiple heights to accommodate patient variability and there are anti-migration features on the superior and inferior surfaces designed to improve fixation, stability, and prevent back out and migration.
Ask a Question
K Number
K220197Device Name
Trigon HA Wedge Fixation System
Manufacturer
Nvision Biomedical Technologies, Inc
Date Cleared
2022-02-23
(30 days)
Product Code
PLF, HRS, HWC
Regulation Number
888.3030Why did this record match?
Applicant Name (Manufacturer) :
Nvision Biomedical Technologies, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Trigon HA Stand-Alone Wedge Fixation System is intended to be used for internal bone fixation for bone fractures or osteotomies in the ankle and foot, such as:
- Cotton (opening wedge) Osteotomies of the Medial Cuneiform
- Evans Lengthening Ssteotomies
- Subtalar Fusion
- First Metatarsal-Cuneiform Lengthening Arthrodesis
The Trigon HA wedges are intended for use with ancillary fixation.
The Trigon HA Stand-Alone Wedge Fixation System is not intended for use in the spine.
Device Description
The Trigon HA Stand-Alone Wedge Fixation System is a family of PEEK Optima HA Enhanced (HA PEEK) wedges with tantalum markers used for angular correction of small bones of the foot. The wedges incorporate two screw-receiving holes, surface teeth, and an area to contain grafting material. The wedges are designed in rectangular, kidney, circular and oval shaped footprints in a range of sizes and in multiple thicknesses. The associated 2.5mm diameter titanium screws are designed in lengths of 10 to 30mm.
When used with the provided screw fixation the Trigon wedges may be used with or without ancillary plating, except for the Lapidus Wedges which will require ancillary fixation not provided in the Trigon System. When used without the provided screws, Trigon wedges are intended for use with ancillary fixation.
Ask a Question
K Number
K211650Device Name
The Radian MIS Bunion System
Manufacturer
Nvision Biomedical Technologies, Inc
Date Cleared
2021-11-24
(180 days)
Product Code
HRS, CLA
Regulation Number
888.3030Why did this record match?
Applicant Name (Manufacturer) :
Nvision Biomedical Technologies, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Radian MS Bunion System is intended for fixation of osteotomies and corrective procedures of the hallux and associated disorders such as hallux valgus.
Device Description
The Radian MIS Bunion System is a single-use bone fixation device intended to be permanently implanted. The system consists of a titanium alloy plate and screws that provide fixation for the first metatarsal in the correction of a bunion. The plate has 4 screw-receiving holes. It is designed to allow for intramedullary insertion of the 2 proximal screws and medial insertion of the 2 distal screws. The plate is provided in 1 size and 1 configuration that can be used across all patient anatomy. The locking 3.0mm diameter titanium screws are designed in lengths of 14mm to 30mm in increments of 2mm. The system is provided non-sterile.
Ask a Question
K Number
K213421Device Name
Vector® Hammertoe Correction System
Manufacturer
Nvision Biomedical Technologies, Inc
Date Cleared
2021-11-19
(30 days)
Product Code
HWC, CLA
Regulation Number
888.3040Why did this record match?
Applicant Name (Manufacturer) :
Nvision Biomedical Technologies, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Vector Hammertoe Correction System is indicated for the fixation of osteotomies and reconstruction of the lesser toes following correction procedures for hammertoe, claw toe, and mallet toe.
Device Description
The Vector Hammertoe Correction System is comprised of a sterile PEEK (polyetheretherketone) HA (hydroxyapatite) fixation device. The implants are offered in Ø3.00mm, Ø3.50mm and Ø4.00mm and in 0° angle. The system has K-wires, drill, taps, implant inserters, and sizers manufactured from medical grade stainless steel.
Ask a Question
K Number
K210424Device Name
Quantum Anterior Cervical Plate
Manufacturer
Nvision Biomedical Technologies, Inc.
Date Cleared
2021-10-22
(253 days)
Product Code
KWQ
Regulation Number
888.3060Why did this record match?
Applicant Name (Manufacturer) :
Nvision Biomedical Technologies, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Quantum Anterior Cervical Plate is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical fusion in patients with:
·degenerative disc disease (as defined by neck pain of discogenic origin with
degeneration of the disc confirmed by patient history and radiographic studies),
· spondylolisthesis,
- · trauma (i.e. fractures or dislocations),
- · tumors.
- · deformity (defined as kyphosis, lordosis, or scoliosis),
- · pseudarthrosis.
- · failed previous fusion,
- · spinal stenosis.
Device Description
The Quantum Anterior Cervical Plate is a titanium alloy plate, conforming to ASTM F3001, intended for anterior screw fixation of the plate to the cervical spine. The fixation construct consists of a cervical plate that is attached to the vertebral body of the cervical spine with selfdrilling and self-tapping bone screws using an anterior approach. Plates are available in a variety of lengths (08 mm - 110 mm), addressing multiple levels of fixation (one to five). The plate incorporates graft visualization holes on the longitudinal center line for intraoperative visualization. Bone screws are available in three diameters (3.75 mm. and 4.75 mm) and a variety of lengths (10 mm - 20 mm). Screws are made from titanium alloy per ASTM F136.
Ask a Question
Page 1 of 2