Found 2 results

510(k) Data Aggregation

    K Number
    K222673
    Device Name
    Alexandrite and Nd:YAG Laser models CANLASE and TORLASE
    Date Cleared
    2022-11-17

    (72 days)

    Product Code
    Regulation Number
    878.4810
    Why did this record match?
    Applicant Name (Manufacturer) :

    Canadian Pioneer Medical Technology Corporation (CPMT LASER)

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdparty
    Intended Use
    755mm: Temporary hair reduction. Stable long-term or permanent reduction targeting of melanin in hair follicles. Permanent hair reduction is defined as long-term stable reduction in the number of hairs regrowing after a treatment regime. Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime. On all skin types (Fitzpatrick I-VI) including tanned skin. Treatment of benign pigmented lesions. Treatment of wrinkles. The photocoagulation of dermatological vascular lesions (such as port-wine stains, hemangiomas, telangiectasias). 1064nm: Removal of unwanted hair, for stable long term or permanent hair reduction and for treatment hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime. The lasers are indicated on all skin types Fitzpatrick I-VI including tanned skin. Photocoagulation and hemostasis of pigmented and vascular lesions such as but not limited to port wine stains, hemangioma, warts, telangiectasia, rosacea, venus and spider veins. Coagulation and hemostasis of soft tissue. Benign pigmented lesions such as, but not limited to, lentigos (age spots), solar lentigos (sun spots), cafe au lait macules, seborrheic keratosis, nevi, chloasma, verrucae, skin tags, keratosis, tattoos (significant reduction in the intensity of black and/or blue-black tattoos) and plaques. The laser is indicated for pigmented lesion size. for patients with lesions that would potentially benefit from aggressive treatment, and for patients with lesions that have not responded to other laser treatments. Reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar. Treatment of wrinkles. Temporary increase of clear nail in patients with onychomycosis ( e.g., dermatophytes, Trichophyton rubrum and T. mentagrophytes, and/or yeast Candida Albicans, etc.)
    Device Description
    Alexandrite Nd:YAG laser Models CPMT CANLASE , CPMT TORLASE contain two separate laser heads (Alexandrite and Nd:YAG), which produce laser light outputs of 755 nm and 1064 nm, respectively. The output of each laser head is optically combined on the laser rail, so that their beam paths are identical as they exit the laser system. This allows the use of a single delivery system which can output either 755 nm or 1064 nm wavelengths. The laser system creates a beam of high intensity light that penetrates deep into the skin tissue where it delivers a controlled amount of therapeutic heat.
    Ask a Question

    Ask a specific question about this device

    K Number
    K222915
    Device Name
    Quadruple Laser System , Models : CPMT ARES , CPMT NEMESIS , CPMT NYX PLUS , CPMT GRACE PLUS
    Date Cleared
    2022-11-15

    (50 days)

    Product Code
    Regulation Number
    878.4810
    Why did this record match?
    Applicant Name (Manufacturer) :

    Canadian Pioneer Medical Technology Corporation (CPMT LASER)

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdparty
    Intended Use
    The device is intended for use in dermatologic and general surgical procedures. The simultaneous triple wavelength handpiece is intended for use in dermatology procedures requiring coagulation. The indications for use for the Triple wavelength handpiece include: Benign vascular and vascular dependent lesions removal. The indications for use for the handpiece of 1064nm include: - -The Hair Removal is intended for permanent reduction in hair regrowth defined as a long term, stable reduction in the number of hairs re-growing when measured at 6,9 and 12 months after the completion of a treatment regimen. - Treatment of Pseudo folliculitis Barbae (PFB) - - Use on all skin types (Fitzpatrick I-VI), including tanned skin. - The indications for use for the handpiece of 808 nm include: - -The Hair Removal (HR) is intended for permanent reduction in hair regrowth defined as a long term, stable reduction in the number of hairs re-growing when measured at 6,9 and 12 months after the completion of a treatment regimen. - The treatment of benign vascular and pigmented lesions. - - -Use on all skin types (Fitzpatrick I-VI), including tanned skin. The indications for use for the handpiece of 755 nm include: - The Hair Removal (HR) is intended for permanent reduction in hair regrowth defined as a long term, stable reduction in the number of hairs re-growing when measured at 6,9 and 12 months after the completion of a treatment regimen. - The treatment of benign vascular and pigmented lesions. - - -Use on all skin types (Fitzpatrick I-VI), including tanned skin.
    Device Description
    The Quadruple Laser System consists of the main unit and a hand piece. The system uses a diode laser as an active medium placed in an optical cavity to produce amplified beam. A microprocessor is used to control electronics for the front panel. A self-contained water cooling system is built into the power supply unit. The Laser treatment device is designed to be used in dermatological practice for stable, long term hair reduction. The principle of laser hair removal is selective photothermolysis. The wavelength of 808nm, 755, and 1064nm would be able to effectively penetrate deep into and absorbed by the target chromophore. The laser power is delivered to the treatment region via a delivery system. The proposed device includes power supply system, control system, control system, cooling system, laser system. The 755nm, 808 nm, 1064nm handpieces with different treatment sizes are available for different models.