510(k) Data Aggregation

    K Number
    K231635
    Device Name
    A-Line Advanced
    Manufacturer
    Date Cleared
    2023-06-06

    (1 days)

    Product Code
    Regulation Number
    872.5470
    Panel
    Dental
    Reference & Predicate Devices
    Why did this record match?
    Applicant Name (Manufacturer) :

    Biocetec Co., Ltd

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    A-Line Advanced orthodontic ceramic bracket is intended to be bonded to a tooth to apply pressure to a tooth from a flexible orthodontic wire to alter its position.

    Device Description

    This orthodontic bracket is made of polycrystalline ceramic and is used for the treatment of malocclusion. It is designed to be attached to the surface of patients' teeth and be connected to the orthodontic wire in order to apply physical pressure on the tooth movement. Each model differs in size and dimension, color identification as they are attached to the tooth surface corresponding to 20 of the 28 permanent teeth.

    AI/ML Overview

    The provided text is a 510(k) summary for a medical device called "A-Line Advanced" (an orthodontic ceramic bracket). It does not describe a study involving an algorithm, AI, or human readers, so many of the requested items are not applicable.

    Here's the information that can be extracted and a note for those that are not present:


    1. A table of acceptance criteria and the reported device performance

    The document provides the following performance characteristics and specifications, which serve as acceptance criteria for the device:

    ItemReference StandardsSpecificationReported Performance (from testing)
    Physical and Performance Characteristics
    DimensionISO 27020(2019)-. Torque(±3°)
    -. Angulation(±3°)
    -. Offset (±3°)
    -. Slot length(±0.1 mm)
    -. Slot width(±0.1 mm)
    -. Slot depth(±0.1 mm)
    -. In-out(±0.1 mm)Stated as passed
    CorrosionISO 22674(2016)
    ISO 10271(2020)1.642 ± 0.157 ug/cm² in 7 daysStated as passed
    Hazardous elementsISO 22674(2016)-. Be : 0.00 wt %
    -. Cd : 0.00 wt %
    -. Pb : 0.00 wt %
    -. Ni : 36.59 wt %Stated as passed
    Adhesion Test to toothISO 11405(2015)-. Mean±SD : 7.22 ± 2.34 MPaStated as passed
    Biocompatibility Testing
    CytotoxicityISO 10993-5Non-cytotoxicNon-cytotoxic
    Mucosal IrritationISO 10993-23None IrritationNone Irritation
    Skin SensitizationISO 10993-10Do not show any hypersensitivityDo not show any hypersensitivity
    Acute systemic toxicityISO 10993-11Do not show any acute systemic toxicityDo not show any acute systemic toxicity
    Comparative Performance (Bench Tests)
    Wire Slot Torque strengthISO 27020(Implicitly compared to predicate device)Result demonstrates stability
    Shear Bond StrengthISO 11405(Implicitly compared to predicate device)Showed bond strength
    Bracket Removal TestN/A(Implicitly compared to predicate device)Showed stability of de-bonding performance
    Wire Slot Drag StrengthN/A(Implicitly compared to predicate device)Measured friction
    Door Pull-Out StrengthN/A(Implicitly compared to predicate device)Measured tensile force at fracture
    Adhesive Strength BondingISO/TS 11405(Implicitly compared to predicate device)Conducted to study bonding

    2. Sample size used for the test set and the data provenance

    The document does not specify the exact sample sizes for each test mentioned (e.g., how many brackets were tested for corrosion, how many teeth for adhesion, etc.). The provenance of the data is from non-clinical laboratory testing performed by "KTR (Korea Testing & Research Institute)" and "Seoul National University Dental Hospital Dental Material & Device Evaluation Center." These are non-clinical (bench) tests, not human data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. This is a non-clinical device that does not involve expert image interpretation or ground truth establishment in the context of the requested AI/human reader study format. A "biological evaluation written by an expert [Seoul National University Dental Hospital Dental Material & Device Evaluation Center]" was used to justify not conducting certain biocompatibility tests. No specific number or individual qualifications are listed beyond "expert."

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    Not applicable. There is no human reading or adjudication process described.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is a physical medical device (orthodontic bracket), not an AI-powered diagnostic or assistive tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This is a physical medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for this device would be defined by established engineering and biocompatibility standards (e.g., ISO standards) and the physical properties and performance characteristics of the device when subjected to these standardized tests. It does not involve expert consensus on medical images or pathology.

    8. The sample size for the training set

    Not applicable. This is a physical device, not an AI model requiring a training set.

    9. How the ground truth for the training set was established

    Not applicable. This is a physical device, not an AI model.

    Ask a Question

    Ask a specific question about this device

    K Number
    K163467
    Manufacturer
    Date Cleared
    2017-06-14

    (184 days)

    Product Code
    Regulation Number
    872.5470
    Panel
    Dental
    Reference & Predicate Devices
    Why did this record match?
    Applicant Name (Manufacturer) :

    BIOCETEC CO., LTD

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    C-LineTM orthodontic ceramic bracket is intended to be bonded to a tooth to apply pressure to a tooth from a flexible orthodontic wire to alter its position

    Device Description

    C-Line ™ orthodontic ceramic brackets are intended to be bonded to a tooth to apply pressure to a tooth to alter its position. C-Line ™ orthodontic ceramic brackets consist of a translucent alumina body and a bonding base. The bracket's color marking and cords indicates the bracket positioning and facilitate bracket identification.

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study details for the C-Line Orthodontic Ceramic Bracket, structured to answer your specific questions.

    Important Note: The provided document is a 510(k) summary for a medical device (orthodontic ceramic bracket). It establishes substantial equivalence by comparing the new device to a predicate device, rather than proving a specific clinical performance. Therefore, sections related to AI performance, human reader improvement, and distinct ground truth for training/test sets are not applicable as this is not an AI/ML medical device.


    Acceptance Criteria and Study Overview

    The C-Line Orthodontic Ceramic Bracket K163467 sought to demonstrate substantial equivalence to a predicate device (Clarity Advanced Ceramic Bracket, K102803) by showing similar performance in non-clinical (bench) tests and comparable design characteristics and intended use. The "acceptance criteria" here are implied by the comparison to the predicate device, meaning the new device should perform similarly or better than the predicate in engineering tests without raising new questions of safety or effectiveness.

    1. Table of Acceptance Criteria and Reported Device Performance

    As this is a substantial equivalence determination based on non-clinical testing against a predicate, "acceptance criteria" are not explicitly defined as numerical thresholds. Instead, the performance of the applicant device (C-Line) is compared directly to the predicate device (Clarity Advanced) to demonstrate similarity.

    Performance CharacteristicAcceptance Criterion (Implied - Similar to Predicate)Reported Device Performance (C-Line)
    Mechanical Properties"similar to the predicate device"
    Wire Slot Drag TestSimilar to predicateResult of test data was similar for both brackets.
    Wire Slot Torque TestSimilar to predicateC-Line brackets had higher torque strength than Clarity Advanced brackets due to the higher in/out thickness of C-Line. (This difference was not flagged as raising new safety/effectiveness concerns).
    Shear TestSimilar to predicateTwo brackets had a very similar shear strength. No fracture occurred during debonding.
    Bracket Removal TestSimilar performance to predicateC-Line brackets had a tendency to remain adhesive lower than Clarity Advanced because of the undercut pattern base, implying an acceptable debonding outcome. Most adhesive remained on enamel.
    BiocompatibilityCompliance with ISO 10993 standardsAll user directly contacting materials are compliance with ISO10993 requirements (Cytotoxicity, Sensitization, Oral Mucosal Irritation, Systemic Toxicity, Degradation Products from Ceramics).
    Design CharacteristicsConforming to ISO 27020:2010Conforms to ISO 27020:2010. Slight differences in bracket in-out and torque angles were noted but deemed not to raise new safety/effectiveness questions.

    2. Sample Size Used for the Test Set and Data Provenance

    The document does not explicitly state the numerical sample sizes for the "test set" for each individual bench test. It mentions "bench testing" was conducted on the C-Line device and the predicate device. The provenance is not specified, but the manufacturing company is based in the Republic of Korea, suggesting the testing was likely performed there or by a contract lab. The tests are "non-clinical," so "retrospective or prospective" data provenance is not applicable in the human data sense.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    Not applicable. This is a non-clinical, bench testing study, not a study involving human expert interpretation for ground truth.

    4. Adjudication Method for the Test Set

    Not applicable. This is a non-clinical, bench testing study.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance

    Not applicable. This is not an AI/ML device.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) Was Done

    Not applicable. This is not an AI/ML device.

    7. The Type of Ground Truth Used

    The "ground truth" for the non-clinical tests would be the established scientific and engineering principles and the performance of the legally marketed predicate device. For example:

    • For mechanical properties (shear strength, torque strength), the "ground truth" is measured physical values and established material science expectations.
    • For biocompatibility, the "ground truth" is established by adherence to recognized international standards (ISO 10993 series).
    • For design characteristics, the "ground truth" is conforming to the referenced international standard (ISO 27020:2010).

    8. The Sample Size for the Training Set

    Not applicable. This is not an AI/ML device, so there is no training set in the context of an algorithm.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. This is not an AI/ML device.