Search Results
Found 10 results
510(k) Data Aggregation
K Number
K243865Device Name
AERO MIS Facet Fusion System
Manufacturer
Aurora Spine
Date Cleared
2025-03-24
(97 days)
Product Code
MRW
Regulation Number
N/AWhy did this record match?
Applicant Name (Manufacturer) :
Aurora Spine
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The AERO MIS Facet Fusion System is indicated for the posterior surgical treatment at C2-S1 (inclusive) spinal levels for the following:
- Spondylolisthesis,
- Spondylolysis,
- Pseudoarthrosis or failed previous fusions which are symptomatic, or
- Degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies and/or degenerative disease of the facet with instability.
The system is intended for use with bone graft material.
Device Description
The AERO MIS Facet Fusion System contains various sized facet screws for bilateral stabilization of the facet joints from levels C2 through S1, inclusive. The system is supplied with various orthopedic instruments. There are various facet screw sizes available for implanting to accommodate a range of facet joint sizes and geometries.
Ask a Question
K Number
K221047Device Name
SILO TFX MIS Sacroiliac Joint Fixation System
Manufacturer
Aurora Spine, Inc.
Date Cleared
2022-10-03
(178 days)
Product Code
OUR
Regulation Number
888.3040Why did this record match?
Applicant Name (Manufacturer) :
Aurora Spine, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Aurora Spine SILO TFX MIS Sacroiliac Joint Fixation System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis.
Device Description
The Aurora Spine SILO TFX MIS Sacroiliac Joint Fixation System includes the SILO TFX Cone, SILO TFX Screw, and the SILO TFX Locking Screw and associated manual surgical instruments. The SILO TFX Cone is comprised of titanium alloy and incorporates a hollow conical shaped barrel with two openings for bone screws for additional anchoring. During the procedure, the implant is inserted in line with the SI Joint via a posterior surgical approach, and bone graft material is placed in the barrel of the implant to facilitate additional bone incorporation after surgery.
Ask a Question
K Number
K221399Device Name
ZIP MIS Interspinous Fusion System
Manufacturer
Aurora Spine, Inc.
Date Cleared
2022-07-08
(56 days)
Product Code
PEK
Regulation Number
888.3050Why did this record match?
Applicant Name (Manufacturer) :
Aurora Spine, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Aurora Spine ZIP™ MIS Interspinous Fusion System is a posterior, non-pedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). It is intended for plate fixation/attachment to the spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), lumbar spinal stenosis, spondylolisthesis, trauma (i.e., fracture or dislocation), and/or tumor. The Aurora Spine ZIP™ MIS Interspinous Fusion System is intended for use with bone graft material and is not intended for stand-alone use.
Device Description
The Aurora Spine ZIP™ MIS Interspinous Fusion System is a bilateral locking plate system which attaches to the posterior noncervical spine at the spinous processes. The implants have superior and inferior surfaces and a central chamber for receiving bone graft. The devices are available in a variety of cylinders to accommodate variations in pathology and patient anatomy. The Aurora Spine ZIPTM MIS Interspinous Fusion System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion of the thoracic. lumbar and/or sacral spine.
Ask a Question
K Number
K220610Device Name
SOLO-L
Manufacturer
Aurora Spine Inc
Date Cleared
2022-05-27
(85 days)
Product Code
OVD
Regulation Number
888.3080Why did this record match?
Applicant Name (Manufacturer) :
Aurora Spine Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
SOLO-L is indicated for intervertebral body fusion of the spine in skeletally mature patients who have had at least six months of non-operative treatment. The device system is designed for use with allogenic bone graft comprised of cancellous and/or corticocancellous bone graft and/or autograft to facilitate fusion. One device is used per intervertebral body space.
SOLO-L is intended for use at either one level or two contiguous levels in the lumbar spine, from L2 to S1, for the treatment of degenerative disc disease (DDD) with up to Grade I spondylolisthesis. DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies.
SOLO-L 2-screw cages may be used as a standalone device only when two vertebral body bone screws are used. SOLO-L 4-screw cages may be used as a standalone device only when at least two vertebral body bone screws are inserted in the two medial fixation holes with one inferior and one superior screw trajectory. If the physician chooses to use SOLO-L anterior cages with fewer than two screws in the two medial fixation holes with one inferior and one superior screw trajectory, then an additional supplemental spinal fixation system cleared for use in the lumbosacral spine must be used.
Device Description
SOLO-L is an anterior lumbar interbody fusion device (ALIF) intended to improve stability of the spine while supporting fusion. The SOLO-L constructs are intended for use at either one level or two contiguous levels in the lumbar spine, from L2 to S1. The cages include a central graft window which may be packed with allogenic bone graft comprised of cancellous and/or corticocancellous bone graft and/or autograft prior to implantation. Components are offered in different shapes and sizes to meet the requirements of the individual patient anatomy. SOLO-L is made from titanium alloy (Ti-6Al-4V ELI). An optional interbody component composed of polyetheretherketone (PEEK) with tantalum markers is available for modular cages.
Ask a Question
K Number
K210521Device Name
DEXA-C Cervical Interbody System
Manufacturer
Aurora Spine, Inc.
Date Cleared
2021-08-02
(160 days)
Product Code
ODP
Regulation Number
888.3080Why did this record match?
Applicant Name (Manufacturer) :
Aurora Spine, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The DEXA-C Cervical Interbody System is indicated for anterior cervical interbody fusion procedures in skeletally mature patients with degenerative disc disease (DDD) of the cervical spine with accompanying radicular symptoms at one or two contiguous levels from C2-T1. DDD is defined as discogenic pain with the degeneration of the disc confirmed by history and radiographic studies. The device system is designed for use with supplemental fixation and autograff and/or allogenic bone graft composed of cancellous, cortical, and/or cortico-cancellous bone to facilitate fusion and is to be implanted via an open, anterior approach.
Device Description
The DEXA-C Cervical Interbody System is a porous 3D-printed intervertebral body fusion device that incorporates low-, mid-, or high-density lattice pattern options. The profile of the device is rectangular with a hollow core for bone graft to promote bone integration and fusion between the endplates. The device is available in various footbrints and heights to accommodate variability among patients and is manufactured from titanium alloy per ASTM F3001.
Ask a Question
K Number
K210325Device Name
APOLLO Anterior Cervical Plate (ACP) System
Manufacturer
Aurora Spine, Inc.
Date Cleared
2021-03-23
(47 days)
Product Code
KWQ
Regulation Number
888.3060Why did this record match?
Applicant Name (Manufacturer) :
Aurora Spine, Inc
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The APOLLO™ Anterior Cervical Plate (ACP) System is intended for anterior screw fixation to the cervical spine. It is to be used in skeletally mature patients as an adjunct to fusion of the cervical spine (C2 to T1). The system is indicated for use in the temporary stabilization of the anterior spine during the development of cervical spinal fusion in patients with:
· Degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies),
- · Spondylolisthesis,
- · Trauma (including fractures or dislocations),
- · Tumors,
- · Deformity (defined as kyphosis, lordosis, or scoliosis),
- · Pseudarthrosis,
- · Failed previous fusion,
- · Spinal stenosis
Device Description
The APOLLO™ Anterior Cervical Plate (ACP) System is comprised of cervical plates and bone screws constructed of titanium alloy as described by ASTM F136. Plates are available in multiple levels and lengths, and screws are available in multiple diameters, lengths, and tip configurations to accommodate variations in patient anatomy. The Integrated screw locking mechanism is used to block the screw heads after the device construct has been attached to the anterior cervical spine.
Ask a Question
K Number
K141317Device Name
ZIP MIS INTERSPINOUS FUSION SYSTEM
Manufacturer
AURORA SPINE, INC.
Date Cleared
2014-11-17
(181 days)
Product Code
PEK
Regulation Number
888.3050Why did this record match?
Applicant Name (Manufacturer) :
AURORA SPINE, INC
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Aurora Spine ZIP™ MIS Interspinous Fusion System is a posterior, non-pedicle supplemental fixation device, intended for use in the non-cervical spine (TI-S1). It is intended for plate fixation/attachment to the spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), and/or tumor. The Aurora Spine ZIP™ MIS Interspinous Fusion System is intended for use with bone graft material and is not intended for stand-alone use.
Device Description
The Aurora Spine ZIPIM MIS Interspinous Fusion System is a bilateral locking plate system which attaches to the posterior noncervical spinous processes. The implants have superior and inferior surfaces and a central chamber for receiving bone graft. The devices are available in a variety of cylinders to accommodate variations in pathology and patient anatomy. The Aurora Spine ZIP™ MIS Interspinous Fusion System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion of the thoracic, lumbar and/or sacral spine.
Ask a Question
K Number
K140715Device Name
ZIP MIS INTERSPINOUS FUSION SYSTEM
Manufacturer
AURORA SPINE, INC.
Date Cleared
2014-04-17
(27 days)
Product Code
PEK
Regulation Number
888.3050Why did this record match?
Applicant Name (Manufacturer) :
AURORA SPINE, INC
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Aurora Spine ZIP™ MIS Interspinous Fusion System is a posterior, non-pedicle supplemental fixation device, intended for use in the non-cervical spine (T1-S1). It is intended for plate fixation/attachment to the spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), and/or tumor. The Aurora Spine ZIP™ MIS Interspinous Fusion System is intended for use with bone graft material and is not intended for stand-alone use.
Device Description
The Aurora Spine ZIP™ MIS Interspinous Fusion System is a bilateral locking plate system which attaches to the posterior noncervical spine at the spinous processes. The implants have superior and inferior surfaces and a central chamber for receiving bone graft. The devices are available in a variety of cylinders to accommodate variations in pathology and patient anatomy. The Aurora Spine ZIP™ MIS Interspinous Fusion System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion of the thoracic, lumbar and/or sacral spine.
Ask a Question
K Number
K133967Device Name
INTERBODY CAGE SYSTEM
Manufacturer
AURORA SPINE
Date Cleared
2014-01-31
(38 days)
Product Code
MAX, ODP
Regulation Number
888.3080Why did this record match?
Applicant Name (Manufacturer) :
AURORA SPINE
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
Lumbar System Indications: The Aurora Spine Interbody Fusion System devices are indicated for use as intervertebral body fusion devices in skeletally mature patients with degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by patient history and radiographic studies) at one or two contiguous levels of the lumbar spine (L2-S1). Patients should have six months of non-operative treatment prior to surgery. These implants are used to facilitate fusion in the lumbar spine and are placed via either a posterior, transforaminal, lateral or anterior approach using autogenous bone. When used as interbody fusion devices these implants are intended for use with supplemental fixation systems cleared for use in the thoracolumbar spine.
Cervical System Indications: The Aurora Spine Interbody Fusion System is indicated for use as an intervertebral body fusion device in skeletally mature patients with degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by patient history and radiographic studies) at one level of the cervical spine with accompanying radicular symptoms. Patients should have six weeks of non-operative treatment prior to surgery. Cervical implants are used to facilitate fusion in the cervical spine (C2-T1) and are placed via an anterior approach using autogenous bone. When used as an interbody fusion device, supplemental fixation must be used.
Device Description
The Aurora Spine Interbody Fusion System, manufactured from PEEK-Optima®, consist of implants available in various foot prints, heights and lordotic configurations with an open architecture to accept packing of autograft materials. The exterior of the device has "teeth" or other generally sharp engagement members on the superior and inferior surfaces to help prevent the device from migrating once it is surgically positioned. The device comes in a PEEK or PEEK with a plasma-sprayed commercially pure titanium coating on the superior and inferior surfaces.
Ask a Question
K Number
K133091Device Name
ZIP MIS INTERSPINOUS FUSION SYSTEM
Manufacturer
AURORA SPINE
Date Cleared
2013-11-27
(58 days)
Product Code
PEK
Regulation Number
888.3050Why did this record match?
Applicant Name (Manufacturer) :
AURORA SPINE
AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP Authorized
Intended Use
The Aurora Spine ZIPTM MIS Interspinous Fusion System is a posterior, non-pedicle supplemental fixation device, intended for use at a single level in the non-cervical spine (T)-SI). It is intended for plate fixation/attachment to the spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), and/or tumor. The Aurora Spine ZIPTM MIS Interspinous Fusion System is intended for use with bone graft material and is not intended for stand-alone use.
Device Description
The Aurora Spine ZIP™ MIS Interspinous Fusion System is a bilateral locking plate system which attaches to the posterior noncervical spine at the spinous processes. The implants have superior and inferior surfaces and a central chamber for receiving bone graft. The devices are available in a variety of cylinders to accommodate variations in pathology and patient anatomy. The Aurora Spine ZIP™ MIS Interspinous Fusion System is intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion of the thoracic, lumbar and/or sacral spine. The Aurora Spine ZIP™ MIS Interspinous Fusion System is manufactured from titanium alloy (Ti-6A1-4V ELI in accordance with ASTM F136 or ISO 5832-3).
Ask a Question