DJR · Enzyme Immunoassay, Methadone

Clinical Toxicology · 21 CFR 862.3620 · Class 2

Overview

Product CodeDJR
Device NameEnzyme Immunoassay, Methadone
Regulation21 CFR 862.3620
Device ClassClass 2
Review PanelClinical Toxicology
3rd-Party ReviewableYes

Identification

A methadone test system is a device intended to measure methadone, an addictive narcotic pain-relieving drug, in serum and urine. Measurements obtained by this device are used in the diagnosis and treatment of methadone use or overdose and to determine compliance with regulations in methadone maintenance treatment.

Classification Rationale

Class II (special controls). A methadone test system is not exempt if it is intended for any use other than employment or insurance testing or is intended for Federal drug testing programs. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9, provided the test system is intended for employment and insurance testing and includes a statement in the labeling that the device is intended solely for use in employment and insurance testing, and does not include devices intended for Federal drug testing programs (e.g., programs run by the Substance Abuse and Mental Health Services Administration (SAMHSA), the Department of Transportation (DOT), and the U.S. military).

Special Controls

*Classification.* Class II (special controls). A methadone test system is not exempt if it is intended for any use other than employment or insurance testing or is intended for Federal drug testing programs. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9, provided the test system is intended for employment and insurance testing and includes a statement in the labeling that the device is intended solely for use in employment and insurance testing, and does not include devices intended for Federal drug testing programs (*e.g.,* programs run by the Substance Abuse and Mental Health Services Administration (SAMHSA), the Department of Transportation (DOT), and the U.S. military).

Recent Cleared Devices (20 of 63)

Showing 20 most recent of 63 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K192433LZI Methadone II Enzyme ImmunoassayLin-Zhi International, Inc.Oct 4, 2019SESE
K182779ARK EDDP AssayArk Diagnostics, Inc.Nov 21, 2018SESE
K170416LZI Methadone Metabolite Enzyme Immunoassay, LZI Methadone Metabolite (100 and 300) CalibratorsLin-Zhi International, Inc.Jun 26, 2017SESE
K160793First Sign Drug of Abuse Dip Card Test (MDMA, EDDP, Nortriptyline), First Sign Drug of Abuse Cup Test (MDMA, EDDP, Nortriptyline)W.H.P.M., Inc.Aug 17, 2016SESE
K152025AssureTech Buprenorphine Tests (Strip, Panel Dip, Quick Cup, Turn-Key Split Cup), AssureTech Methadone Tests (Strip, Panel Dip, Quick Cup, Turn-Key Split Cup)Assure Tech. Co., Ltd.Oct 5, 2015SESE
K151395Immunalysis EDDP Specific Urine Enzyme Immunoassay, Immunalysis EDDP Urine Calibrators, Immunalysis EDDP Urine Control SetsImmunalysis CorporationJul 24, 2015SESE
K151441First Sign Drug of Abuse Dip Card Test, First Sign Drug of Abuse Cup TestW.H.P.M., Inc.Jun 29, 2015SESE
K131232WONDFO METHADONE URINE TEST (MTD 200), WONDOFO MORPHINE URINE TEST (MOP 100)Guangzhou Wondfo Biotech Co., Ltd.May 31, 2013SESE
K092272RANDOX METHADONE ASSAYRandox Laboratories, Ltd.Nov 18, 2010SESE
K092258RANDOX METABOLITE (EDDP) ASSAYRandox Laboratories, Ltd.Nov 9, 2010SESE
K092048ONE STEP EDDP (METHADONE METABOLITE) TEST STRIPBiosite IncorporatedApr 19, 2010SESE
K081378DRI METHADONE METABOLITE (100/300) ASSAY, CALIBRATORS AND CONTROLSThermo Fisher ScientificJan 14, 2009SESE
K062637VITROS CHEMISTRY PRODUCTS METD REAGENT, CALIBRATOR KIT 26, DAT PERFORMANCE, VERIFIERS I, II, III, IV & VOrtho-Clinical Diagnostics, Inc.Nov 22, 2006SESE
K060791TRIAGE TOX DRUG SCREEN, MODEL 94400Biosite IncorporatedJun 22, 2006SESE
K052197FIRST SIGN DRUG OF ABUSE URINE SCREENING TESTW.H.P.M., Inc.Jun 9, 2006SESE
K051058METHADONE ORAL FLUID HOMOGENEOUS ENZYME IMMUNOASSAY, CALIBRATORS AND CONTROLSLin-Zhi International, Inc.Mar 29, 2006SESE
K040570RANDOX METHADONE ASSAYRandox Laboratories, Ltd.May 10, 2004SESE
K031797METHADONE METABOLITE (EDDP) ENZIME IMMUNOASSAY, CAT. NO. 190 (500 TEST KIT), NO. 191 (5000 TEST KIT)Lin-Zhi International, Inc.Oct 10, 2003SESE
K023617DRI METHADONE METABOLITE ENZYME IMMUNOASSAYMicrogenics Corp.Aug 27, 2003SESE
K023856VISUALINE METHADONE DIPSTRIPTESTSun Biomedical Laboratories, Inc.Aug 25, 2003SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...