K973554 · Valley Forge Scientific Corp. · JOS · Dec 19, 1997 · General, Plastic Surgery
Device Facts
Record ID
K973554
Device Name
VALLEY FORGE BIPOLAR BALL TIP ELECTRODE
Applicant
Valley Forge Scientific Corp.
Product Code
JOS · General, Plastic Surgery
Decision Date
Dec 19, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.4400
Device Class
Class 2
Attributes
Therapeutic
Intended Use
The bipolar ball electrodes are designed for electrosurgical coagulation of soft tissue in an irrigated or wet surgical field.
Device Story
Bipolar ball electrodes facilitate electrosurgical coagulation of soft tissue. Device utilizes bipolar technology where electrical current flows between two halves of the ball electrode, eliminating need for grounding pads and reducing current spread to adjacent tissue. Operates at lower voltages than monopolar systems, minimizing thermal damage. Designed for use in bloody, wet, or irrigated surgical fields, including neurological and gynecological procedures. Operated by surgeons to achieve precise, localized coagulation without charring or sticking. System provides smooth, progressive coagulation and allows for precise, flow-controlled irrigation. Benefits include reduced risk of patient burns, minimal damage to surrounding tissue, and effective performance in fluid-filled surgical environments.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Bipolar electrosurgical instrument featuring ball-tip geometry. Utilizes bipolar energy delivery; eliminates patient return path for current. Operates at low output impedance and specific programmed waveforms for coagulation. Designed for use with irrigation systems. No specific materials or ASTM standards cited.
Indications for Use
Indicated for electrosurgical coagulation of soft tissue in irrigated or wet surgical fields. For prescription use only.
Regulatory Classification
Identification
An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.
Related Devices
K971986 — VALLEY FORGE BIPOLAR LOOP · Valley Forge Scientific Corp. · Aug 26, 1997
K964143 — MINI-SYMM BIPOLAR COAGULATOR · Valley Forge Scientific Corp. · Jan 9, 1997
K955764 — VALLEY FORGE BIPLOAR LOOP · Valley Forge Scientific Corp. · Mar 1, 1996
K020622 — ARTHROCARE CONTROLLER (SYSTEM 2000 AND 8000); ARTHROCARE CABLE; FOOT CONTROL; POWER CORD; AND WANDS · Arthrocare Corp. · Mar 28, 2002
Submission Summary (Full Text)
{0}------------------------------------------------
## EXHIBIT V
DEC 1 9 1997 Page 1 of 2
510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________
Device Name: Bipolar Ball Electrodes
## SUMMARY OF SAFETY AND EFFECTIVE INFORMATION
Dr. Leonard I. Malis, the world's foremost authority on bipolar electrosurgery and codeveloper of the Valley Forge Scientific Corp bipolar ball coagulating electrodes, has been using bipolar coagulation since the early 1950's. The bipolar ball electrodes are an extension of his instrumentation and technique that has made bipolar the methodology of choice in neurological gynecological and other surgical arcas. Dr. Malis states that "Since all of the current used to coagulate flows between the two halves of the ball clectrodes, there is no current spread to adjacent tissue and, accordingly, no heat spread. Additionally, the bipolar ball electrodes are able to coagulate in bloody, wet or irrigated ficlds."
{1}------------------------------------------------
Some of the effective safety features of Bipolar Electrosurgery are:
- * Dipolar Technology eliminates the need for grounding pads and the possibility of patient burns.
- * Bipolar Coagulation minimizes damage to adjacent tissue since the patient is no longer the return path for the electrical current.
- * Bipolar Technology works at voltages approximately 1/4th the voltage required for monopolar technique, and therefore, there is very little thermal tissue damage.
- * Localized Bipolar Coagulation gives the surgeon precise control of the electric current at the tissue site.
- * The bipolar system's patented waveform and exceedingly low output impedance provide superior coagulation and the absence of charring and sticking even in a dry field.
- * Because of the high output impedance of monopolar and other bipolar systems, instruments short-out in an irrigated or bloody field.
- * Unlike monopolar systems, bipolar electrosurgery provides smooth, progressive coagulation with the option of precise, flow-controlled irrigation.
- * Bipolar technology permits the physician to coagulate in an irrigated field thereby minimizing heat build-up or thermal damage to adjacent tissues.
- * The waveform parameters of the Valley Forge Bipolar Electrosurgery Systems are programmed for the smoothest, most gentle, precise and efficient cutting and coagulation of tissue during any surgical procedure.
{2}------------------------------------------------
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Image /page/2/Picture/3 description: The image shows a date written in a simple, bold font. The date is "DEC 19 1997". The month is abbreviated to three letters, and the day and year are written numerically.
Mr. Jerry L. Malis President Valley Forge Scientific Corporation 136 Green Tree Road Oaks, Pennsylvania 19456
Re: K973554
> Trade Name: Valley Forge Bipolar Ball Tip Electrode Regulatory Class: II Product Code: JOS Dated: September 18, 1997 Received: September 19, 1997
Dear Mr. Malis:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirements , as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for
{3}------------------------------------------------
Page 2 - Mr. Malis
devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html".
Sincerely yours.
tovell
Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
## EXHIBIT VI
Page 1 of 1
510(k) Number (if known): _K973554
Binular Ball Electrodes Device Name: __
Indications for Use:
The bipolar ball electrodes are designed for electrosurgical coagulation of soft
e The Dipolar ban esconnititiated or wet surgical field.
l 2 l 8e×vi
**Prescription Use**
**(Per 21 CFR 801.109)**
coll
(Division Sign-Off)
Division of al Restorative Devices
5. Number L973584
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.