SPINE-TECH BONE HARVESTER
Device Facts
| Record ID | K970040 |
|---|---|
| Device Name | SPINE-TECH BONE HARVESTER |
| Applicant | Spine-Tech, Inc. |
| Product Code | HWE · General, Plastic Surgery |
| Decision Date | Feb 28, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 878.4820 |
| Device Class | Class 1 |
| Attributes | Therapeutic |
Indications for Use
The Spine-Tech Bone Harvester is indicated for the cutting and collection of morselized autogenous bone graft from the anterior or posterior iliac crest, tibia or femur. This device is intended to cut and collect finely morselized autogenous bone graft for any surgical procedure requiring bone graft to facilitate fusion and/or fill bone defects. These procedures include; spinal fusion, joint arthrodesis, total joint replacement, fracture repair, maxillofacial reconstruction and tumor removal. All components of the Spine-Tech Bone Harvested are intended for single use only.
Device Story
Manual/powered surgical instrument for harvesting morselized autogenous bone graft; consists of cutting head, collection tube, trocar, and plunger. Operates by cutting bone tissue; collected graft stored in tube; removed via trocar and plunger. Used in OR by surgeons. Benefits patient by providing autogenous graft for fusion/defect filling. Single-use device.
Clinical Evidence
Bench testing only; includes biocompatibility testing per ASTM standards, dimensional inspection, and workmanship inspection. All results acceptable.
Technological Characteristics
Materials: stainless steel (cutting heads, trocar), medical grade polycarbonate (collection tube, adapter), acetal copolymer (plunger). Manual or power-driven (Hudson/Hall fitting). Single-use.
Indications for Use
Indicated for patients requiring autogenous bone graft harvesting from iliac crest, tibia, or femur for surgical procedures including spinal fusion, joint arthrodesis, total joint replacement, fracture repair, maxillofacial reconstruction, and tumor removal.
Regulatory Classification
Identification
Surgical instrument motors and accessories are AC-powered, battery-powered, or air-powered devices intended for use during surgical procedures to provide power to operate various accessories or attachments to cut hard tissue or bone and soft tissue. Accessories or attachments may include a bur, chisel (osteotome), dermabrasion brush, dermatome, drill bit, hammerhead, pin driver, and saw blade.
Predicate Devices
- Acumed Bone Graft System
- Spine-Tech Bone Harvester, Non-Powered
- General and Orthopedic Surgical Instruments, Accessories/Attachments
Related Devices
- K170539 — Avitus Bone Harvester with Filter Insert - 5mm, Avitus Bone Harvester - 5mm, Avitus Bone Harvester with Filter Insert - 8mm, Avitus Filter Insert - 8mm, Avitus Filter Insert - 5mm · Avitus Orthopaedics, Inc. · Mar 20, 2017
- K973560 — BONE GRAFT HARVESTER · Ds Mfg., Inc. · Nov 12, 1997
- K152474 — Avitus Bone Harvester · Avitus Orthopaedics, Inc. · Oct 23, 2015
- K971268 — BONE & MARROW CLLECTION SYSTEM · Biomedical International Corp. · Jul 3, 1997
- K243407 — Forcyte Autograft Harvest Kit · Forcyte Medical, LLC · Jul 29, 2025