GAW · Suture, Nonabsorbable, Synthetic, Polypropylene

General, Plastic Surgery · 21 CFR 878.5010 · Class 2

Overview

Product CodeGAW
Device NameSuture, Nonabsorbable, Synthetic, Polypropylene
Regulation21 CFR 878.5010
Device ClassClass 2
Review PanelGeneral, Plastic Surgery
ImplantYes

Identification

Nonabsorbable polypropylene surgical suture is a monofilament, nonabsorbable, sterile, flexible thread prepared from long-chain polyolefin polymer known as polypropylene and is indicated for use in soft tissue approximation. The polypropylene surgical suture meets United States Pharmacopeia (U.S.P.) requirements as described in the U.S.P. Monograph for Nonabsorbable Surgical Sutures; it may be undyed or dyed with an FDA approved color additive; and the suture may be provided with or without a standard needle attached.

Classification Rationale

Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA.” See § 878.1(e) for the availability of this guidance document.

Special Controls

*Classification.* Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Surgical Sutures; Guidance for Industry and FDA.” See § 878.1(e) for the availability of this guidance document.

Recent Cleared Devices (20 of 86)

Showing 20 most recent of 86 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K253572STRATAFIX™ Spiral PRONOVA™ Unidirectional Knotless Tissue Control Device STRATAFIX™ Spiral PRONOVA™ Bidirectional Knotless Tissue Control DeviceETHICON, Inc.Mar 27, 2026SESE
K233355Cypris eXact Suturing SystemCypris MedicalJan 12, 2024SESE
K230746Non absorbable Surgical Polypropylene SutureShandong Haidike Medical Products Co., Ltd.Sep 14, 2023SESE
K221280VessealLydus Medical , Ltd.Dec 9, 2022SESE
K211178DURAMESH Mesh SutureMsiSep 2, 2022SESE
K192953APTOS Threads – Polypropylene Surgical SuturesAptos, LLCAug 27, 2020SESE
K193530Deklene MAXXTeleflex MedicalMar 19, 2020SESE
K191299Silhouette Featherlift / Silhouette LiftSilhouette Lift, Inc.Jun 14, 2019SESE
K173747REXLENESm Eng Co., Ltd.Dec 21, 2018SESE
K180321Aesculap Optilene Nonabsorbable SutureAesculap, Inc.Mar 7, 2018SESE
K173644Gazelle Polypropylene Suture and Delivery DeviceDura Tap, LLCFeb 15, 2018SESE
K171039Assut Filbloc Permanent SuturesAssut Europe S.P.A.Aug 29, 2017SESE
K171005Silhouette FeatherliftSilhouette Lift, Inc.May 3, 2017SESE
K162617NobleStitch ELNobles Medical Technologies Ii, Inc.Apr 6, 2017SESU
K160529Pledgeted COR-SUTURE QUICK LOADLsi SoultionsSep 15, 2016SESE
K143582MOPYLEN, RESOPREN, SILK, POLYESTER, NYLON, RESOLON, POLYAMIDE PSEUDO, STEELResorba Medical GmbHOct 29, 2015SESE
K151112Quill Polypropylene Knotless Tissue-Closure Device, Variable Loop DesignAngiotechSep 10, 2015SESE
K141206EDWARDS LIFESCIENCES THRUPORT KNOTTING SYSTEMEdwards Lifesciences, LLCJan 16, 2015SESE
K142639StitchKitOrigami Surgical, LLCDec 16, 2014SESE
K133890AESCULAP OPTILENE NONABSORBABLE SUTUREAesculap, Inc.Jul 15, 2014SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...