STRYKER KNIFELIGHT
Device Facts
| Record ID | K961122 |
|---|---|
| Device Name | STRYKER KNIFELIGHT |
| Applicant | Stryker Instruments |
| Product Code | FTD · General, Plastic Surgery |
| Decision Date | Aug 22, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 878.4580 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The Stryker Knifelight is a manual surgical instrument used for the release of ligaments or other tissue including, but not limited to, the carpal tunnel ligament. It features an integrated light source to illuminate the surgical site. The Stryker Knifelight allows for a minimally open technique with minimal disturbance of surrounding tissue.
Device Story
Manual surgical instrument; sterile, single-use, disposable ligament/tissue release knife. Features integrated light source for site illumination; integral protective retractors for tissue protection. Used in surgical settings by physicians for minimally open procedures (e.g., carpal tunnel release). Provides improved visualization in restricted-view areas; facilitates ligament/tissue division via blade and optional standard elevator. Benefits include minimal disturbance of surrounding tissue and enhanced surgical site visibility.
Clinical Evidence
Bench testing only.
Technological Characteristics
Manual surgical knife; integrated light source; integral protective retractors; optional standard elevator. Sterile, single-use, disposable device.
Indications for Use
Indicated for patients undergoing minimally open surgical release of ligaments or tissues, including carpal tunnel ligament release. Intended to improve visualization of carpal ligament, median nerve, and functional ligaments/tendons in restricted view areas.
Regulatory Classification
Identification
A surgical lamp (including a fixture) is a device intended to be used to provide visible illumination of the surgical field or the patient.
Special Controls
*Classification.* Class II (special controls). The device, when it is an operating room lamp, a surgical instrument light, a surgical floor standing light, an endoscopic surgical light, a surgical light connector, a ceiling mounted surgical light, a surgical light carrier, surgical light accessories, a surgical lamp, a remote illuminator, or an incandescent surgical lamp, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 878.9.
Reference Devices
- Biomet (unspecified)
- Medtronic (unspecified)
Related Devices
- K100884 — STRYKER KNIFELIGHT · Howmedica Osteonics Corp. · Jun 25, 2010
- K981717 — STRYKER KNIFELIGHT, STRYKER ILLUMINATED RETRACTOR · Stryker Instruments · Jun 30, 1998
- K242417 — VECTR Video Endoscopic Carpal Tunnel Release System · Rafael Medical Devices, LLC · Dec 11, 2024
- K982142 — MOUNTABLE ENDOSCOPIC KNIFE · A.M. Surgical, Inc. · Dec 30, 1998
- K252020 — TunnelVision Endoscopic Soft Tissue Release System and the HBL Blade Assembly · Hand Biomechanics Lab, Inc. · Oct 15, 2025