RETROARC RETROPUBIC SLING SYSTEM

K132655 · American Medical Systems, Inc. · OTN · Nov 20, 2013 · General, Plastic Surgery

Device Facts

Record IDK132655
Device NameRETROARC RETROPUBIC SLING SYSTEM
ApplicantAmerican Medical Systems, Inc.
Product CodeOTN · General, Plastic Surgery
Decision DateNov 20, 2013
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.3300
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The RetroArc™ Retropubic Sling System is intended for the placement of a suburethral sling for the treatment of female stress urinary incontinence (SUI) resulting from urethral hypermobility and/or intrinsic sphincter deficiency (ISD).

Device Story

RetroArc Retropubic Sling System is a sterile, single-use surgical kit for treating female stress urinary incontinence. System includes a detachable plastic handle, two stainless steel delivery needles, and a polypropylene mesh sling assembly with an integrated adjustment suture. During surgery, physician uses the handle to guide delivery needles through tissue to place the suburethral sling. Integrated suture allows for post-placement tension adjustment without additional tools. Connectors and sheaths facilitate mesh passage but are not implanted. Device provides mechanical support to the urethra to restore continence. Used in clinical/surgical settings by physicians.

Clinical Evidence

No clinical testing was performed. Substantial equivalence is supported by bench testing (sterilization, shelf life, biocompatibility, delivery instrument torsional strength, needle connection cycling, push/pull forces) and cadaver evaluations.

Technological Characteristics

Implant: Polypropylene mesh with integrated adjustment suture. Delivery system: Stainless steel needles, plastic handle. Principle: Mechanical suburethral support. Connectivity: None. Sterilization: Sterile, single-use.

Indications for Use

Indicated for female patients with stress urinary incontinence (SUI) caused by urethral hypermobility and/or intrinsic sphincter deficiency (ISD).

Regulatory Classification

Identification

Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Examples of surgical mesh are metallic and polymeric mesh for hernia repair, and acetabular and cement restrictor mesh used during orthopedic surgery.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ # 510(k) Summary As required by 21CFR 807.92(c) # 510(k) Number: _ K132655_ | Date Prepared:<br>Submitter Information: | August 23, 2013 | |------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------| | Submitter's Name/<br>Address: | American Medical Systems<br>10700 Bren Road W.<br>Minnetonka. MN 55343 | | Contact Person: | Renee Mellum<br>Sr. Regulatory Affairs Specialist<br>Tel: 952-930-6458<br>Fax: 952-930-5785<br>Renee.Mellum@AmericanMedicalSystems.com | | Alternate Contact: | Melanie Hess<br>Director, Regulatory Affairs<br>Tel: 952-939-6490<br>Fax: 952-930-5785<br>Melanie.Hess@AmericanMedicalSystems.com | #### Device Information: | RetroArc" Retropubic Sling System | |-----------------------------------| | Surgical Mesh | | 21 CFR § 878.3300 | | OTN | | | ## Predicate Device: SPARC® Sling System (K081613) #### Device Description: The RetroArc System is a sterile, single use system, consisting of one plastic handle, two stainless steel delivery needles and a sling assembly. The tip portion of each delivery needle is configured to allow for passage through tissue. The opposite end of the needle is configured to connect with the plastic handle. The handle is detachable and is used to direct both delivery needles through tissue. The sling assembly includes one piece of loosely knitted polypropylene mesh with an integrated adjustment suture, two removable plastic insertion sheaths, and two connectors attached to the insertion sheaths. The adjustment suture is an integral feature woven into the {1}------------------------------------------------ # 510(k) Summary As required by 21CFR 807.92(c) mesh which limits the overall stretch of the mesh arms during the procedure. The integrated suture and mesh, allow for adjustment of the sling after initial placement in the patient without the use of additional tools. The two plastic sheaths overlap during placement and allow for convenient travel of the sling through the tissue. The connectors, sheaths, and delivery instruments are used to facilitate placement of the mesh assembly, and are not implanted. The mesh component is not absorbed by the action of tissue in-growth or tissue enzymes # Indications for Use: The RetroArc Retropubic Sling System is intended for the placement of a suburethral sling for the treatment of female stress urinary incontinence (SUI) resulting from urethral hypermobility and/or intrinsic sphincter deficiency (ISD). #### Comparison to the Predicate Device: The fundamental scientific technology on the RetroArc" Retropubic Sling System is unchanged from the predicate device. The intended use and indication for use is identical to that of the predicate device. In addition, the RetroArc System utilizes the same sling assembly, utilizing the identical implant materials and design principles as the predicate SPARC Sling System (K081613). The primary change to the device is the delivery instruments to allow for placement of the sling using a retropubic approach. The changes to the delivery needle include a longer length, an increased needle angle, and larger needle diameter. The plastic handle was also modified to allow for detachment of the delivery needle after placement. This allows one handle to be used to direct both delivery needles through tissue. #### Summary of Non-Clinical Testing: Bench testing was performed to support this submission. Results of the testing demonstrate that the RetroArc Retropubic Sling System meets product specification and performance requirements. The following testing has been successfully completed: - . Sterilization - Shelf Life ● - Biocompatibility . - Performance Testing (Bench) . - Delivery Instrument Torsional Strength 0 {2}------------------------------------------------ # 510(k) Summary As required by 21CFR 807.92(c) - Needle Connection Cycling 0 - Needle Connection Push Force O - Needle Disconnection Pull Force 0 - Needle Disconnection Button Force 0 - . Performance Testing (Cadaver) - Physician Questionnaire 0 - Cadaver Evaluation o - Cadaver Dissection O ## Clinical Testing: No clinical testing was performed to support this Traditional 510(k) Premarket Application. ## Statement of Equivalence: The RetroArc Retropubic Sling System has the identical indications for use and fundamental scientific technology as the predicate device. Based on this and the design and engineering data provided in the pre-market notification, the RetroArc Retropubic Sling System has been shown to be substantially equivalent. {3}------------------------------------------------ #### DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 November 20, 2013 American Medical Systems, Inc. Renee Mellum Sr. Regulatory Affairs Specialist 10700 Bren Road West Minnetonka, MN 55343 Re: K132655 > Trade/Device Name: RetroArc™ Retropubic Sling System Regulation Number: 21 CFR§ 878.3300 Regulation Name: Surgical mesh Regulatory Class: II Product Code: OTN Dated: August 23, 2013 Received: August 26, 2013 Dear Renee Mellum, We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of {4}------------------------------------------------ ## Page 2 - Renee Mellum medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm 1 15809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.goy/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, Benjamin R. Fisher -S Benjamin R. Fisher, Ph.D. Director Division of Reproductive. Gastro-Renal. and Urological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ ## Indications for Use K132655 510(k) Number: __ Device Name: RetroArc'" Retropubic Sling System Indications for Use: The RetroArc™ Retropubic Sling System is intended for the placement of a suburethral sling for the treatment of female stress urinary incontinence (SUI) resulting from urethral hypermobility and/or intrinsic sphincter deficiency (ISD). Prescription Use X (Per 21 CFR 801 Subpart D) AND/OR Over-The Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH. Office of Device Evaluation (ODE) # Benjamin R. Fisher -S 2013.11.20 16:52:15 -05'00' Page 1 of 1
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...