ODA · Endoscopic Central Control Unit

Gastroenterology, Urology · 21 CFR 876.1500 · Class 2

Overview

Product CodeODA
Device NameEndoscopic Central Control Unit
Regulation21 CFR 876.1500
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Recent Cleared Devices (18 of 18)

RecordDevice NameApplicantDecision DateDecision
K232406KARL STORZ OR1™ SCB CONTROL (WU300)Karl Storz SE & CO. KGOct 3, 2023SESE
K221929Smith+Nephew INTELLIO TabletSmith+NephewSep 6, 2022SESE
K203566Tablet ApplicationSmith & NephewMay 13, 2021SESE
K192876INTELLIO Tablet ApplicationSmith & NephewFeb 27, 2020SESE
K153205IDSS ForceTriad Control ModuleBlack Diamond Video, Inc.Aug 1, 2016SESE
K151282core nova Complete Operating Room EndoscopyRichard Wolf Medical Instruments Corp.Jan 12, 2016SESE
K111165KARL STORZ SCB / COVIDIEN FORCETRIAD INTERFACE MODULEKARL STORZ Endoscopy-America, Inc.Jan 6, 2012SESE
K102763SYSTEMS INTEGRATIONOlympus Medical Systems CorporationFeb 15, 2011SESE
K100345SYSTEMS INTEGRATION MODEL: ENDOALPHAOlympus Medical Systems CorporationMar 22, 2010SESE
K083598KARL STORZ VOICE1 SCB R-UI SPEECH CONTROL APPLICATIONKARL STORZ Endoscopy-America, Inc.May 29, 2009SESE
K080410KARL STORZ SCB/CONMED ESU INTERFACE MODULE, MODEL 20091522KARL STORZ Endoscopy-America, Inc.Apr 9, 2008SESE
K070827KARL STORZ SCB INTERFACE CONTROL, MODEL 20090120KARL STORZ Endoscopy-America, Inc.May 22, 2007SESE
K051613MODIFICATION TO OLYMPUS INTEGRATED ENDOSURGERY SYSTEM ENDOALPHA (CONTROL UNIT FOR ENDOSURGERY UCES-2) SOFTWARE VERSION 3Olympus Medical Systems CorporationAug 15, 2005SESE
K041912SCB/VALLEYLAB FORCE FX INTERFACE UNITKARL STORZ Endoscopy-America, Inc.Oct 25, 2004SESE
K020255RIWO NET OPERATING OPERATING CONTROL SYSTEM, MODEL #5590Richard Wolf Medical Instruments Corp.Sep 18, 2002SESE
K022270MODIFICATION TO OLYMPUS INTEGRATED ENDOSURGERY SYSTEM ENDOALPHAOlympus Optical Co., Ltd.Aug 14, 2002SESE
K994231SIEMENS INTEGRATED OPERATING SYSTEM (SIOS)Siemens Medical Corp.Aug 10, 2000SESE
K981993OLYMPUS INTEGRATED ENDOSURGERY SYSTEM ENDOALPHAThe Olympus Optical Co.Aug 21, 1998SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...