IFP · Formalin, Neutral Buffered

Pathology · 21 CFR 864.4010 · Class 1

Overview

Product CodeIFP
Device NameFormalin, Neutral Buffered
Regulation21 CFR 864.4010
Device ClassClass 1
Review PanelPathology
GMP ExemptYes

Identification

A general purpose reagent is a chemical reagent that has general laboratory application, that is used to collect, prepare, and examine specimens from the human body for diagnostic purposes, and that is not labeled or otherwise intended for a specific diagnostic application. It may be either an individual substance, or multiple substances reformulated, which, when combined with or used in conjunction with an appropriate analyte specific reagent (ASR) and other general purpose reagents, is part of a diagnostic test procedure or system constituting a finished in vitro diagnostic (IVD) test. General purpose reagents are appropriate for combining with one or more than one ASR in producing such systems and include labware or disposable constituents of tests; but they do not include laboratory machinery, automated or powered systems. General purpose reagents include cytological preservatives, decalcifying reagents, fixative and adhesives, tissue processing reagents, isotonic solutions and pH buffers. Reagents used in tests for more than one individual chemical substance or ligand are general purpose reagents (e.g., Thermus aquaticus (TAQ) polymerase, substrates for enzyme immunoassay (EIA)).

Classification Rationale

Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter.

Recent Cleared Devices (15 of 15)

RecordDevice NameApplicantDecision DateDecision
K884755CONSED FECAL CONCENTRATION SYSTEMDonald L. Price, Ph.D.Jan 10, 1989SESE
K872663DRY-FORMAnatech, Ltd.Aug 6, 1987SESE
K872140(MSI) PATH-SAVERMedical Specialties, Inc.Jun 15, 1987SESE
K870852NBF 10% NEUTRAL BUFFERED FORMALINAnatech, Ltd.Mar 31, 1987SESE
K853497PREFILLED SPECIMEN JARS 10% NEUTRAL BUF-FORMALINSurgipath Medical Industries, Inc.Aug 28, 1985SESE
K842982FORMALIN BUFFEREDReagent Laboratory, Inc.Oct 1, 1984SESE
K842940CBA FORMALINAnatech, Ltd.Aug 28, 1984SESE
K842728BUF-FIXE K Ind., Inc.Aug 3, 1984SESE
K840926FORMALIN SOLUTION 10% NEUTRAL BUFFERSigma Chemical Co.Mar 12, 1984SESE
K830583NEUTRAL BUFFERED FORMALIN 10%Surgipath Medical Industries, Inc.Mar 17, 1983SESE
K830582MILLONIG'S MODIFIED PHOSPHATE BUFFEREDSurgipath Medical Industries, Inc.Mar 17, 1983SESE
K830514MILLONIGS MODIFIED PHOSPHATE BUFFEREDSurgipath Medical Industries, Inc.Mar 8, 1983SESE
K81294010% NEUTRAL BUFFERED FORMALIN CONCENTSurgipathDec 10, 1981SESE
K812817NEUTRAL DUFFERED FORMA-SCENTMeridian Diagnostics, Inc.Nov 10, 1981SESE
K81179510% NEUTRAL BUFFERED FORMALDEHYDERichard-Allan Medical Ind., Inc.Jul 28, 1981SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...