← Product Code [HWE](/submissions/SU/subpart-e%E2%80%94surgical-devices/HWE) · K962800

# STRYKER UNIVERSAL DRILL ATTACHMENTS & ACCESSORIES (K962800)

_Stryker Instruments · HWE · Sep 11, 1996 · General, Plastic Surgery · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/OR/subpart-e%E2%80%94surgical-devices/HWE/K962800

## Device Facts

- **Applicant:** Stryker Instruments
- **Product Code:** [HWE](/submissions/SU/subpart-e%E2%80%94surgical-devices/HWE.md)
- **Decision Date:** Sep 11, 1996
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 878.4820
- **Device Class:** Class 1
- **Review Panel:** General, Plastic Surgery
- **Attributes:** Therapeutic

## Indications for Use

The Stryker Universal Drill Attachments and Accessories are intended for use in the cutting, drilling, reaming, decorticating, and smoothing of bone and other bone related tissue in a variety of surgical procedures including: ENT, orthopedic, maxillofacial, neuro, and plastics.

## Device Story

System consists of surgical drill attachments and accessories used with Stryker 75K Drill motor; powered by DC electric current via Total Performance System Console. Attachments include extra-long variants (up to 400 mm) and Hudson Chuck (reduces speed from 75,000 rpm to 700-1200 rpm) for cranial perforators. Used by surgeons in OR settings for bone tissue manipulation. Provides mechanical cutting/drilling action; output is physical bone modification. Benefits include surgical versatility and compatibility with standard Hudson shank fittings.

## Clinical Evidence

Bench testing only; no clinical data provided.

## Technological Characteristics

Mechanical surgical attachments; includes Hudson Chuck for speed reduction. Materials and cutting configurations equivalent to predicate surgical accessories. Powered by DC electric motor (Stryker 75K). Sterile or non-sterile delivery.

## Regulatory Identification

Surgical instrument motors and accessories are AC-powered, battery-powered, or air-powered devices intended for use during surgical procedures to provide power to operate various accessories or attachments to cut hard tissue or bone and soft tissue. Accessories or attachments may include a bur, chisel (osteotome), dermabrasion brush, dermatome, drill bit, hammerhead, pin driver, and saw blade.

## Reference Devices

- Midas Rex powered instrument attachments
- Codman powered instrument attachments
- Stryker 75K Drill
- Zimmer/Hall cutting accessories

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}

K 96280D

stryker

SEP 11 1996

4100 East Milham Avenue

Kalamazoo, MI 49001-6197

(616) 323-7700 (800) 253-3210

## Device Name:

**Classification Names:** Instrument, Surgical, Orthopedic, DC Powered Motor and Accessories/Attachments:
21 CFR 878.4820, Class I

**Bur, Surgical, General and Plastic Surgery**
21 CFR 878.4820, Class I

**Blade, Surgical, General and Plastic Surgery**
21 CFR 878.4820, Class I

**Common/Usual Name:** Surgical Instrument Motors and Accessories/Attachments

**Proprietary Name:** Stryker Universal Drill Attachments and Accessories

## Device Sponsor:

Stryker Corporation
Instruments Division
4100 E. Milham Avenue
Kalamazoo, MI 49001
Registration No: 1811755

## Regulatory Classification: Class I

## Summary of Safety and Effectiveness:

The Stryker Universal Drill Attachments and Accessories are intended for use in the cutting, drilling, reaming, decorticating, and smoothing of bone and other bone related tissue in a variety of surgical procedures including: ENT, orthopedic, maxillofacial, neuro, and plastics.

The Stryker Universal Drill Attachments are used in conjunction with the previously 510(k) cleared Stryker 75K Drill. The 75K drill motor is powered by DC electric current via the Total Performance System Console. The Extra Long Attachments are up to 400 mm in length. The Hudson Chuck reduces the speed of the 75K drill from 75,000 rpm to 700 - 1200 rpm. This chuck with Hudson fitting holds cranial perforators with a standard Hudson shank fitting.

{1}

The Stryker Universal Attachments are equivalent in intended use, safety, and effectiveness to existing powered instrument attachments marketed by companies such as Midas Rex and Codman.

The cutting accessories available will be provided sterile or nonsterile. The materials of construction, cutting action, and cutting surface configuration are equivalent to pre-1976 Medical Device Amendment cutting accessories distributed by Stryker as well as cutting accessories distributed by Midas Rex and Zimmer/Hall.

The Stryker Universal Drill Attachments and Accessories do not raise any new safety and efficacy concerns when compared to similar devices already legally marketed. Therefore, the Stryker Universal Drill Attachments and Accessories are substantially equivalent to these existing devices.

Diane Davis
Regulatory Affairs Representative
Stryker Instruments

---

**Source:** [https://fda.innolitics.com/submissions/OR/subpart-e%E2%80%94surgical-devices/HWE/K962800](https://fda.innolitics.com/submissions/OR/subpart-e%E2%80%94surgical-devices/HWE/K962800)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
