QHE · Shoulder Arthroplasty Implantation System
Orthopedic · 21 CFR 888.3660 · Class 2
Overview
| Product Code | QHE |
|---|---|
| Device Name | Shoulder Arthroplasty Implantation System |
| Regulation | 21 CFR 888.3660 |
| Device Class | Class 2 |
| Review Panel | Orthopedic |
Identification
A shoulder joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a shoulder joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a humeral resurfacing component made of alloys, such as cobalt-chromium-molybdenum, and a glenoid resurfacing component made of ultra-high molecular weight polyethylene, and is limited to those prostheses intended for use with bone cement (§ 888.3027).
Classification Rationale
Class II. The special controls for this device are:
Special Controls
*Classification.* Class II. The special controls for this device are:(1) FDA's: (i) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices—Part I: Evaluation and Testing,’ ” (ii) “510(k) Sterility Review Guidance of 2/12/90 (K90-1),” (iii) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone Cement,” (iv) “Guidance Document for the Preparation of Premarket Notification (510(k)) Application for Orthopedic Devices,” and (v) “Guidance Document for Testing Non-articulating, ‘Mechanically Locked’ Modular Implant Components,” (2) International Organization for Standardization's (ISO): (i) ISO 5832-3:1996 “Implants for Surgery—Metallic Materials—Part 3: Wrought Titanium 6-aluminum 4-vandium Alloy,” (ii) ISO 5832-4:1996 “Implants for Surgery—Metallic Materials—Part 4: Cobalt-chromium-molybdenum casting alloy,” (iii) ISO 5832-12:1996 “Implants for Surgery—Metallic Materials—Part 12: Wrought Cobalt-chromium-molybdenum alloy,” (iv) ISO 5833:1992 “Implants for Surgery—Acrylic Resin Cements,” (v) ISO 5834-2:1998 “Implants for Surgery—Ultra-high Molecular Weight Polyethylene—Part 2: Moulded Forms,” (vi) ISO 6018:1987 “Orthopaedic Implants—General Requirements for Marking, Packaging, and Labeling,” and (vii) ISO 9001:1994 “Quality Systems—Model for Quality Assurance in Design/Development, Production, Installation, and Servicing,” and (3) American Society for Testing and Materials': (i) F 75-92 “Specification for Cast Cobalt-28 Chromium-6 Molybdenum Alloy for Surgical Implant Material,” (ii) F 648-98 “Specification for Ultra-High-Molecular-Weight Polyethylene Powder and Fabricated Form for Surgical Implants,” (iii) F 799-96 “Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Forgings for Surgical Implants,” (iv) F 1044-95 “Test Method for Shear Testing of Porous Metal Coatings,” (v) F 1108-97 “Specification for Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal,” (vii) F 1378-97 “Standard Specification for Shoulder Prosthesis,” and (viii) F 1537-94 “Specification for Wrought Cobalt-28 Chromium-6 Molybdenum Alloy for Surgical Implants.”
Recent Cleared Devices (20 of 24)
Showing 20 most recent of 24 cleared devices.
| Record | Device Name | Applicant | Decision Date | Decision |
|---|---|---|---|---|
| K260104 | Signature ONE System | Orthosoft Inc. (d/b/a) Zimmer CAS | Feb 4, 2026 | SESE |
| K251558 | Precision AI Surgical Planning System (PAI-SPS) | Precision AI Pty, Ltd. | Jan 12, 2026 | SESE |
| K243509 | Archer PSI System | 3D-Side | May 12, 2025 | SESE |
| K241470 | CORE Shoulder System | LinkBio Corp. | Feb 20, 2025 | SESE |
| K243955 | Precision AI Surgical Planning System (PAI-SPS) | Precision AI Pty, Ltd. | Jan 21, 2025 | SESE |
| K242813 | Materialise Shoulder System, Materialise Shoulder Guide and Models, SurgiCase Shoulder Planner | Materialise NV | Oct 18, 2024 | SESE |
| K241097 | Arthrex Virtual Implant Positioning (VIP) System Software | Arthrex, Inc. | Oct 2, 2024 | SESE |
| K233992 | Precision AI Surgical Planning System (PAI-SPS) | Precision AI Pty, Ltd. | Aug 5, 2024 | SESE |
| K241143 | Materialise Shoulder System, Materialise Shoulder Guide and Models, SurgiCase Shoulder Planner | Materialise NV | May 22, 2024 | SESE |
| K232425 | Signature ONE System | Orthosoft Inc. (D/B/A) Zimmer Cas) | Dec 12, 2023 | SESE |
| K233408 | Materialise Shoulder System, Materialise Shoulder Guide and Models, SurgiCase Shoulder Planner | Materialise NV | Nov 9, 2023 | SESE |
| K231112 | Materialise Shoulder System, Materialise Shoulder Guide and Models, SurgiCase Shoulder Planner | Materialise NV | Sep 12, 2023 | SESE |
| K230904 | Arthrex Virtual Implant Positioning (VIP) System | Arthrex, Inc. | Jun 22, 2023 | SESE |
| K222007 | Arthrex Virtual Implant Positioning (VIP) System | Arthrex, Inc. | Mar 8, 2023 | SESE |
| K230315 | Materialise Shoulder System Materialise Shoulder Guide and Models SurgiCase Shoulder Planner | Materialise NV | Mar 6, 2023 | SESE |
| K222405 | Smart SPACE Shoulder Planner and 3D Positioners | Lima Corporate S.P.A. | Dec 20, 2022 | SESE |
| K220452 | Materialise Shoulder SystemTM Materialise Shoulder Guide and Models SurgiCase Shoulder Planner | Materialise NV | Aug 17, 2022 | SESE |
| K212569 | Materialise Shoulder System, Materialise Shoulder Guide and Models, SurgiCase Shoulder Planner | Materialise NV | Jan 12, 2022 | SESE |
| K212560 | Signature ONE System | Orthosoft Inc (D/B/A Zimmer Cas) | Oct 12, 2021 | SESE |
| K202151 | Smart SPACE Shoulder System | Techmah Medical, LLC | Feb 3, 2021 | SESE |
Top Applicants
- Materialise NV — 8 clearances
- Arthrex, Inc. — 3 clearances
- Orthosoft Inc (D/B/A Zimmer Cas) — 3 clearances
- Precision AI Pty, Ltd. — 3 clearances
- Techmah Medical, LLC — 2 clearances