K220197 · Nvision Biomedical Technologies, Inc. · PLF · Feb 23, 2022 · Orthopedic
Device Facts
Record ID
K220197
Device Name
Trigon HA Wedge Fixation System
Applicant
Nvision Biomedical Technologies, Inc.
Product Code
PLF · Orthopedic
Decision Date
Feb 23, 2022
Decision
SESE
Submission Type
Special
Regulation
21 CFR 888.3030
Device Class
Class 2
Attributes
Therapeutic
Intended Use
The Trigon HA Stand-Alone Wedge Fixation System is intended to be used for internal bone fixation for bone fractures or osteotomies in the ankle and foot, such as: - · Cotton (opening wedge) Osteotomies of the Medial Cuneiform - · Evans Lengthening Ssteotomies - · Subtalar Fusion - · First Metatarsal-Cuneiform Lengthening Arthrodesis The Trigon HA wedges are intended for use with ancillary fixation. The Trigon HA Stand-Alone Wedge Fixation System is not intended for use in the spine.
Device Story
System consists of PEEK Optima HA Enhanced (HA PEEK) wedges with tantalum markers; used for angular correction of small foot bones. Wedges feature two screw-receiving holes, surface teeth, and graft containment area; available in various footprints (rectangular, kidney, circular, oval) and thicknesses. Includes 2.5mm diameter titanium screws (10-30mm lengths). Used by surgeons in clinical settings for internal bone fixation. Wedges may be used with provided screws (with or without ancillary plating) or with ancillary fixation alone (required for Lapidus wedges). Provides structural support for bone healing; benefits patient through stabilization of osteotomies or fractures.
Clinical Evidence
Bench testing only. No clinical data provided. Substantial equivalence demonstrated via engineering analysis comparing device characteristics, materials, and processes to predicate devices.
Technological Characteristics
Materials: PEEK Optima HA Enhanced (HA PEEK) with tantalum markers; titanium screws. Design: Wedges with surface teeth, graft containment area, and screw-receiving holes. Form factor: Various footprints (rectangular, kidney, circular, oval) and thicknesses. Energy source: None (mechanical). Sterilization: Not specified.
Indications for Use
Indicated for internal bone fixation for bone fractures or osteotomies in the ankle and foot, including Cotton osteotomies, Evans lengthening osteotomies, subtalar fusion, and first metatarsal-cuneiform lengthening arthrodesis. Not for use in the spine.
Regulatory Classification
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
Predicate Devices
Nvision Biomedical's Trigon™ HA Stand-Alone Wedge Fixation System (K203445)
Nvision Biomedical's Trigon™ HA Stand-Alone Wedge Fixation System (K193414)
K243231 — Trigon PEEK HA Wedges · Nvision Biomedical Technologies · Nov 8, 2024
K203445 — Trigon HA Stand-Alone Wedge Fixation System · Nvision Biomedical Technologies, Inc. · Dec 21, 2020
K223226 — Trigon HA Stand-Alone Wedge Fixation System · Nvision Biomedical Technologies, Inc. · Dec 1, 2022
K234116 — Trigon Trigon HA Stand-Alone Wedge Fixation System · Nvision Biomedical Technologies · Jan 26, 2024
K193414 — Trigon HA Stand-Alone Wedge Fixation System · Nvision Biomedical Technologies, Inc. · Feb 25, 2020
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue.
February 23, 2022
Nvision Biomedical Technologies, Inc % Analaura Villarreal-Berain Extremity Project Engineer Nvision Biomedical Technologies 4590 Lockhill Selma San Antonio, Texas 78249
Re: K220197
Trade/Device Name: Trigon HA Wedge Fixation System Regulation Number: 21 CFR 888.3030 Regulation Name: Single/Multiple Component Metallic Bone Fixation Appliances And Accessories Regulatory Class: Class II Product Code: PLF. HWC. HRS Dated: January 21, 2022 Received: January 24, 2022
Dear Analaura Villarreal-Berain:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal
{1}------------------------------------------------
statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
For: Shumaya Ali, M.P.H. Assistant Director DHT6C: Division of Restorative, Repair and Trauma Devices OHT6: Office of Orthopedic Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
# Indications for Use
#### 510(k) Number (if known) K220197
Device Name
Trigon HA Stand-Alone Wedge Fixation System
Indications for Use (Describe)
The Trigon HA Stand-Alone Wedge Fixation System is intended to be used for internal bone fixation for bone fractures or osteotomies in the ankle and foot, such as:
- · Cotton (opening wedge) Osteotomies of the Medial Cuneiform
- · Evans Lengthening Ssteotomies
- · Subtalar Fusion
- · First Metatarsal-Cuneiform Lengthening Arthrodesis
The Trigon HA wedges are intended for use with ancillary fixation.
The Trigon HA Stand-Alone Wedge Fixation System is not intended for use in the spine.
| Type of Use (Select one or both, as applicable) |
|-------------------------------------------------|
|-------------------------------------------------|
|X Prescription Use (Part 21 CFR 801 Subpart D)
| Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
# 510(k) Summary
#### DATE PREPARED
February 22, 2022
### MANUFACTURER AND 510(k) OWNER
Nvision Biomedical Technologies, Inc. 4590 Lockhill Selma San Antonio, TX 78249, USA Telephone: (210) 545-3713 Fax: (866) 764-1139 Official Contact: Diana Langham, Director of Regulatory and Corporate Compliance
#### REPRESENTATIVE
Analaura Villarreal-Berain, Extremity Project Engineer Nvision Biomedical Technologies Telephone: (210) 545-3713 ext. 109 Email: analauravillarreal@nvisionbiomed.com
#### PROPRIETARY NAME OF SUBJECT DEVICE
Trigon™ HA Stand-Alone Wedge Fixation System
### COMMON NAME
- Primary Bone Wedge ●
- Screw, Fixation, Bone .
- Plate, Fixation, Bone
## DEVICE CLASSIFICATION
| Device | Product Code | Classification Regulation | Class |
|--------------------|--------------|---------------------------------------------------------------------------------------------------------|-------|
| Primary Bone Wedge | Primary PLF | Primary 21 CFR 888.3030<br>Single/multiple components metallic bone fixation appliances and accessories | II |
| Bone Screw | HWC | 21 CFR 888.3040<br>Smooth or threaded metallic bone fixation fastener | II |
| Bone Plate | HRS | 21 CFR 888.3030<br>Single/multiple components metallic bone fixation appliances and accessories | II |
PREMARKET REVIEW Orthopedic Devices
{4}------------------------------------------------
### INDICATIONS FOR USE
The Trigon HA Stand-Alone Wedge Fixation System is intended to be used for internal bone fixation for bone fractures or osteotomies in the ankle and foot, such as:
- Cotton (opening wedge) osteotomies of the medial cuneiform .
- Evans lengthening osteotomies .
- Subtalar Fusion .
- First Metatarsal-Cuneiform Lengthening Arthrodesis .
The Trigon HA wedges are intended for use with ancillary fixation.
The Trigon HA Stand-Alone Wedge Fixation System is not intended for use in the spine.
#### DEVICE DESCRIPTION
The Trigon HA Stand-Alone Wedge Fixation System is a family of PEEK Optima HA Enhanced (HA PEEK) wedges with tantalum markers used for angular correction of small bones of the foot. The wedges incorporate two screw-receiving holes, surface teeth, and an area to contain grafting material. The wedges are designed in rectangular, kidney, circular and oval shaped footprints in a range of sizes and in multiple thicknesses. The associated 2.5mm diameter titanium screws are designed in lengths of 10 to 30mm.
When used with the provided screw fixation the Trigon wedges may be used with or without ancillary plating, except for the Lapidus Wedges which will require ancillary fixation not provided in the Trigon System. When used without the provided screws, Trigon wedges are intended for use with ancillary fixation.
#### PREDICATE DEVICE IDENTIFICATION
The subject Trigon™ HA Stand-Alone Wedge Fixation System is substantially equivalent to the following predicates:
| 510(k) Number | Predicate Device Name / Manufacturer | Predicate |
|---------------|----------------------------------------------------------------------|------------|
| K203445 | Nvision Biomedical's Trigon™ HA Stand-Alone Wedge<br>Fixation System | Primary |
| K193414 | Nvision Biomedical's Trigon™ HA Stand-Alone Wedge<br>Fixation System | Additional |
| K201314 | restor3d Utility Wedge | Additional |
| K171327 | Tyber Medical Wedge System | Additional |
| K161037 | Life Spine Tarsa-Link Stand-Alone Wedge Fixation<br>System | Additional |
Nvision Biomedical's nva. nvp. nvt (K193645) is also cited in this submission as a reference predicate device.
{5}------------------------------------------------
### SUMMARY OF NON-CLINICAL TESTING
No FDA performance standards have been established for the Trigon HA Stand-Alone Wedge Fixation System. The following was performed to demonstrate safety per methods of the previous submission:
- . Engineering analysis comparing device characteristics including materials, intended use and processes (cleaning and sterilization methods)
The results of this comparison indicate that the Trigon HA Stand-Alone Wedge Fixation System is substantially equivalent to the predicate devices.
#### EQUIVALENCE TO PREDICATE DEVICES
Nvision believes that the Trigon HA Stand-Alone Wedge Fixation System modification is substantially equivalent to the predicate devices. The subject implants maintain the same features as the previously cleared devices with an addition of configurations for different foot procedures commonly performed. This modification does not change the intended use or performance of the device and does not raise additional questions of substantial equivalence. These technological characteristics have undergone a comparison of characteristics to ensure the device is as safe and effective as the predicates.
#### CONCLUSION
Based on the comparison of device characteristics, it can be concluded that the subject device does not raise new issues of safety or efficacy compared to the predicate devices. The similar indications for use, technological characteristics, and performance characteristics for the proposed Trigon HA Stand-Alone Wedge Fixation System options are assessed to be substantially equivalent to the predicate devices.
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.