OIY · Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive

Orthopedic · 21 CFR 888.3560 · Class 2

Overview

Product CodeOIY
Device NameProsthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive
Regulation21 CFR 888.3560
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

A knee joint patellofemorotibial polymer/metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a knee joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and a tibial component or components and a retropatellar resurfacing component made of ultra-high molecular weight polyethylene. This generic type of device is limited to those prostheses intended for use with bone cement (§ 888.3027).

Classification Rationale

Class II.

Recent Cleared Devices (11 of 11)

RecordDevice NameApplicantDecision DateDecision
K242665DePuy ATTUNE™ Total Knee SystemDepuy Orthopedics, Inc.Nov 1, 2024SESE
K201347DePuy ATTUNE™ Total Knee SystemDePuy Orthopaedics, Inc.Jun 18, 2020SESE
K120038A200 KNEE SYSTEMRenovis Surgical Technologies, LLCFeb 14, 2013SESE
K121727MOVATION KNEE SYSTEMEncore Medical L.P.Aug 15, 2012SESE
K113756HIGHLY CROSS LINKED VE CENTRAL PEG PATELLA HIGHLY CROSS LINKED VE TRI-PEG PATELLA HIGHLY CROSS LINKED VE METAL BACKED PAEncore Medical L.P.Mar 14, 2012SESE
K111433DEPUY STTUNE (TM) PS KNEE SYSTEMDePuy Orthopaedics, Inc.Aug 30, 2011SESE
K103756DEPUY ATTUNE TOTAL KNEE SYSTEMDePuy Orthopaedics, Inc.Mar 15, 2011SESE
K103223HIGHLY CROSS-LINKED VITAMIN E UHMWPE TIBIAL INSERTSEncore Medical L.P.Dec 21, 2010SESE
K101433DEPUY ATTUNE KNEE SYSTEMDePuy Orthopaedics, Inc.Dec 10, 2010SESE
K091956HIGHLY CROSS-LINKED VITAMIN E UHMWPE TIBIAL INSERTS, MODEL 391/392-09_19-702_712Encore Medical L.P.Sep 28, 2010SESE
K100048E1 ANTIOXIDANT INFUSED TECHNOLOGYBiomet Manufacturing CorpMar 9, 2010SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...