Orthopedic

MBL · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous

Orthopedic · 21 CFR 888.3358 · Class 2

Overview

Product CodeMBL
Device NameProsthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous
Regulation21 CFR 888.3358
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy or a titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The femoral stem and acetabular shell have a porous coating made of, in the case of Co-Cr-Mo substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. The generic type of device has a design to achieve biological fixation to bone without the use of bone cement.

Classification Rationale

Class II.

Cleared Devices (13)

RecordDevice NameApplicantDecision DateDecision
K201157Prime BIOFOAM® Multi-Hole ShellsMicroport Orthopedics, Inc.Aug 24, 2021SESE
K201701R3 HA Coated Acetabular ShellsSmith & Nephew, Inc.Oct 6, 2020SESE
K182535R3 Anteverted LinersSmith & Nephew, Inc.Nov 19, 2018SESE
K161233OXINIUM DH Fermoral HeadsSmith & Nephew, Inc.Dec 14, 2016SESE
K122382DYNASTY BIOFOAM SHELLWrightmedicaltechnologyincOct 22, 2012SESE
K113848R3 XLPE LINERSSmith & Nephew, Inc.Apr 27, 2012SESE
K102370R3 XLPE ANTEVERTED LINERSSmith & Nephew, Inc.Jan 19, 2011SESE
K093363COCR AND OXINIUM FEMORAL HEADS AND R3 XLPE LINERSSmith & Nephew, Inc.Jan 26, 2010SESE
K092386R3 MULTI-HOLE SHELLS AND 36MM XLPE ACETABULAR LINERSSmith & Nephew, Inc.Nov 3, 2009SESE
K070756SMITH AND NEPHEW REFLECTION 3 ACETABULAR SYSTEMSmith & Nephew, Inc.Jun 6, 2007SESE
K061253REFLECTION 3 ACETABULAR SYSTEMSmith & Nephew, Inc.May 31, 2006SESE
K960094REFLECTION DUAL DIMENSION SHELLSmith & Nephew Richards, Inc.Mar 27, 1996SESE
K931107LOGYK ACETABULAR COMPONENT SYSTEMArthronics, Inc.Mar 28, 1994SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...