← Product Code [KWI](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/KWI) · K212872

# Avenger Radial Head System (K212872)

_In2bones USA, LLC · KWI · Dec 17, 2021 · Orthopedic · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/KWI/K212872

## Device Facts

- **Applicant:** In2bones USA, LLC
- **Product Code:** [KWI](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/KWI.md)
- **Decision Date:** Dec 17, 2021
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3170
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Intended Use

The Avenger Radial Head System is intended for replacement of the proximal end of the radius: Replacement of the radial head for degenerative or post-traumatic disabilities presenting pain, crepitation, and decreased motion at radial-humeral and/or proximal radio-ulnar joint with: a. Joint destruction and/or subluxation visible on x-ray; and/or b. Resistance to conservative treatment. Primary replacement after fracture of the radial head. Symptomatic sequelae after radial head resection. Revision following failed radial head arthroplasty. The components are intended for uncemented use.

## Device Story

Avenger Radial Head System is a two-piece modular orthopedic implant for proximal radius replacement. System includes cobalt chrome head and stem components in various diameters and lengths; subject of this submission is a new range of +4mm offset stems. Device is used by surgeons in clinical settings to restore joint function in patients with degenerative or post-traumatic radial head disabilities. Implants are intended for uncemented fixation. Surgeon selects appropriate head/stem sizes to match patient anatomy. Output is a mechanical prosthetic replacement for the radial head, intended to alleviate pain and restore motion at the radial-humeral and proximal radio-ulnar joints.

## Clinical Evidence

Bench testing only. Performance testing included head disassembly (ASTM F2009) comparing the +4mm offset stems to the previously cleared K192754 system. Fatigue, sterilization, and endotoxin testing were addressed via adoption of data from previously cleared devices.

## Technological Characteristics

Two-piece modular radial head prosthesis. Materials: Cobalt chrome (ASTM F 1537). Design: Range of stem lengths/diameters and head diameters/heights, including +4mm offset stems. Fixation: Uncemented. Sterilization: Not specified (adopted from predicate).

## Regulatory Identification

An elbow joint radial (hemi-elbow) polymer prosthesis is a device intended to be implanted made of medical grade silicone elastomer used to replace the proximal end of the radius.

## Predicate Devices

- In2Bones Avenger Radial Head System ([K192754](/device/K192754.md))
- Wright Medical Evolve® Modular Radial Head ([K991915](/device/K991915.md))
- Wright Medical Evolve® Modular Radial Head ([K060731](/device/K060731.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

December 17, 2021

Image /page/0/Picture/1 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health & Human Services logo on the left and the FDA logo on the right. The FDA logo is a blue square with the letters "FDA" in white, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue.

In2Bones USA, LLC Christine Scifert VP of Quality and Regulatory 6000 Poplar Ave, Suite 115 Memphis. Tennessee 38119

Re: K212872

Trade/Device Name: Avenger Radial Head System Regulation Number: 21 CFR 888.3170 Regulation Name: Elbow joint radial (hemi-elbow) polymer prosthesis Regulatory Class: Class II Product Code: KWI Dated: November 1, 2021 Received: November 3, 2021

Dear Christine Scifert:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for

{1}------------------------------------------------

devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.

For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely.

For Jiping Chen, Ph.D., M.P.H. Acting Division Director DHT6A: Division of Joint Arthroplasty Devices OHT6: Office of Orthopedic Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

# Indications for Use

510(k) Number (if known) K212872

Device Name Avenger Radial Head System

#### Indications for Use (Describe)

The Avenger Radial Head System is intended for replacement of the proximal end of the radius:

• Replacement of the radial head for degenerative or post-traumatic disabilities presenting pain, crepitation, and decreased motion at radial-humeral and/or proximal radio-ulnar joint with:

- a. Joint destruction and/or subluxation visible on x-ray; and/or
- b. Resistance to conservative treatment.
- · Primary replacement after fracture of the radial head.
- · Symptomatic sequelae after radial head resection.
- Revision following failed radial head arthroplasty.

The components are intended for uncemented use.

| Type of Use (Select one or both, as applicable) |
|-------------------------------------------------|
|-------------------------------------------------|

> Prescription Use (Part 21 CFR 801 Subpart D)

| Over-The-Counter Use (21 CFR 801 Subpart C)

#### CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

## 510(k) Summary

Avenger Radial Head System September 2, 2021

| Company:           | In2Bones USA, LLC<br>6000 Poplar Ave, Suite 115<br>Memphis, TN 38119<br>901-260-7931 |
|--------------------|--------------------------------------------------------------------------------------|
| Primary Contact:   | Christine Scifert                                                                    |
| Company Contact:   | Rebecca Wahl                                                                         |
| Trade Name:        | Avenger Radial Head System                                                           |
| Common Name:       | Modular Radial Head                                                                  |
| Classification:    | II                                                                                   |
| Regulation Number: | 21 CFR 888.3170, Elbow joint radial (hemi elbow) polymer prosthesis                  |
| Panel:             | 87-Orthopedic                                                                        |
| Product Code(s):   | KWI                                                                                  |

The Avenger Radial Head System is a two-piece modular system comprised of cobalt chrome Device Description: (ASTM F 1537) head and stem components. The system consists of a range of lengths and diameters for the stem as well as heads in a range of diameters and heights to accommodate the patient anatomy. The subject of this 510(k) is to clear a new range of stem implants (+4mm offset stems) that can be used to extend the current range of the Avenger Radial Headle modular system. The implant allows for replacement of the radial head.

Indications for Use

Intended Use:

The Avenger Radial Head System is intended for replacement of the proximal end of the radius:

- Replacement of the radial head for degenerative or post-traumatic disabilities presenting pain, crepitation, and decreased motion at radial-humeral and/or proximal radio-ulnar joint with:
	- a. Joint destruction and/or subluxation visible on x-ray; and/or
	- b. Resistance to conservative treatment.
- Primary replacement after fracture of the radial head.
- Symptomatic sequelae after radial head resection.
- Revision following failed radial head arthroplasty. ●

The components are intended for uncemented use.

{4}------------------------------------------------

Substantial Equivalence: The subject components were demonstrated to be substantially equivalent to the following systems previously cleared by the FDA:

Primary Predicate

- . K192754 – In2Bones Avenger Radial Head System
Additional Predicates

- . K991915, K060731 - Wright Medical Evolve® Modular Radial Head
The subject Avenger Radial Head is made of cobalt chrome and has been demonstrated to be substantially equivalent to the previously cleared devices identified above as the products are similar in indications, materials and geometry.

Performance Testing: Head disassembly (ASTM F2009) was performed for the Avenger Radial Head System, +4mm offset stems comparing to the previously cleared K192754 devices. Fatigue testing, sterilization and endotoxin testing were able to adopt into the previously cleared devices.

### Conclusion

Based on the test results and the comparison to the predicate device is determined to be substantially equivalent to the predicate devices.

---

**Source:** [https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/KWI/K212872](https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/KWI/K212872)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
