MONOTUBE CARBON TUBE
Device Facts
| Record ID | K963614 |
|---|---|
| Device Name | MONOTUBE CARBON TUBE |
| Applicant | Howmedica Corp. |
| Product Code | JEC · Orthopedic |
| Decision Date | Nov 6, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 888.3040 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The Monotube® Carbon Tubes, previously cleared in a premarket 510(k) submission, are connecting elements for use with the Monotube® Clamps for the construction of external fixation frames. The tubes are available in 15mm, 20mm and 25mm diameters and a variety of lengths to accommodate varying anatomical situations.
Device Story
Monotube® Carbon Tubes serve as structural connecting elements for external fixation frames; used with Monotube® Clamps. Device facilitates orthopedic stabilization by connecting frame components. Available in 15mm, 20mm, 25mm diameters and various lengths to suit anatomical requirements. Operated by orthopedic surgeons in clinical/surgical settings. Submission addresses changes in material and manufacturing method compared to previously cleared versions.
Clinical Evidence
Bench testing only. Comparative static mechanical property testing of existing vs. new tubes; static axial compressive frame testing to evaluate yield strength and stiffness.
Technological Characteristics
External fixation connecting tubes; diameters 15mm, 20mm, 25mm; variable lengths. Metallic construction (implied by classification 888.3040).
Indications for Use
Indicated for use as connecting elements in external fixation frames for orthopedic stabilization.
Regulatory Classification
Identification
A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.
Predicate Devices
- Monotube® Carbon Tubes (previously cleared)
Related Devices
- K961618 — MONOTUBE TUBE TO RING CLAMP · Howmedica Corp. · May 28, 1996
- K122208 — EXTERNAL FIXATOR SYSTEM · Christopher D. Endara · Dec 20, 2012
- K031919 — EBI XFIX DFS SYSTEM · Ebi, L.P. · Sep 4, 2003
- K960782 — TITANIUM TUBE TO TUBE CLAMP · Synthes (Usa) · May 8, 1996
- K961916 — HOFFMANN II CARBON CONNECTING ROD · Howmedica, Inc. · Aug 1, 1996