DEPUY CANNULATED CROSS PIN SCREW SYSTEM
Device Facts
| Record ID | K963973 |
|---|---|
| Device Name | DEPUY CANNULATED CROSS PIN SCREW SYSTEM |
| Applicant | Depuy, Inc. |
| Product Code | JDW · Orthopedic |
| Decision Date | Dec 16, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 888.3040 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The DePuy Cannulated Cross Pin Screws are intended to provide early fixation of autogenous or allogeneic tendon grafts in surgical procedures for anterior cruciate ligament (ACL) reconstruction.
Device Story
Cannulated cross pin screws; titanium alloy; headless; proximally threaded; smooth shanks with two tapers; blunt distal tip. Used in ACL reconstruction; provides early fixation of autogenous or allogeneic tendon grafts. Operated by orthopedic surgeons in OR. Cannulated design allows use with guide pins. Available in 45mm-75mm lengths. Benefits include secure graft fixation during ligament reconstruction.
Clinical Evidence
Bench testing only.
Technological Characteristics
Titanium alloy; cannulated; headless; proximally threaded; smooth shanks with dual tapers; blunt distal tip; lengths 45-75mm.
Indications for Use
Indicated for patients undergoing anterior cruciate ligament (ACL) reconstruction requiring fixation of autogenous or allogeneic tendon grafts.
Regulatory Classification
Identification
A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.
Predicate Devices
- DePuy Titanium Cross Pin Screw System (K954630)
- DePuy Cross Pin Screw System (K946228)
- Arthrex SemiFix ACL Reconstruction System
Related Devices
- K961234 — DEPUY ADVANTAGE FIXATION SCREW SYSTEM · Depuy, Inc. · Jun 19, 1996
- K960704 — DEPUY M. KUROSAKA ADVANGE MANGNUM REV. INTERFERENCE SCREWS · Depuy, Inc. · Jun 6, 1996
- K981670 — DEPUY PROFILE ROUND HEAD INTERFERENCE SCREW AND DEPUY PHANTOM RESORBABLE INTERFERENCE SCREW · Depuy, Inc. · Jun 22, 1998
- K021351 — BIOSTEON CROSS PIN · Biocomposites, Ltd. · Oct 17, 2002
- K182955 — EZStart Interference Screw · Conmed Corporation · Jan 22, 2019