LFIT V40 FEMORAL HEAD COMPONENTS

K010757 · Howmedica Osteonics Corp. · JDI · Apr 11, 2001 · Orthopedic

Device Facts

Record IDK010757
Device NameLFIT V40 FEMORAL HEAD COMPONENTS
ApplicantHowmedica Osteonics Corp.
Product CodeJDI · Orthopedic
Decision DateApr 11, 2001
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 888.3350
Device ClassClass 2
AttributesTherapeutic

Intended Use

These devices are modular components of a total hip system. These femoral heads are intended for use with femoral stems and acetabular components in primary or revision total hip arthroplasty.

Device Story

LFIT™ V40™ femoral heads are modular orthopedic implants used in total hip arthroplasty. Fabricated from cobalt-chromium alloy, these components interface with femoral stems and acetabular components to restore hip joint function. Intended for use in primary or revision surgeries, the device is implanted by orthopedic surgeons in a clinical/hospital setting. The design features an outer diameter range of 22mm to 32mm with varying neck offsets to accommodate patient anatomy. The device functions as a mechanical bearing surface within the hip prosthesis, facilitating joint articulation and mobility.

Clinical Evidence

Bench testing only.

Technological Characteristics

Modular femoral head components; material: cobalt-chromium alloy (ASTM F799); dimensions: 22mm to 32mm outer diameter with varying neck offsets; intended for use with femoral stems and acetabular components in total hip arthroplasty.

Indications for Use

Indicated for patients undergoing primary or revision total hip arthroplasty requiring modular femoral head components.

Regulatory Classification

Identification

A hip joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum, and an acetabular resurfacing component made of ultra-high molecular weight polyethylene and is limited to those prostheses intended for use with bone cement (§ 888.3027).

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ### APR 1 1 2001 # 010757 11 Special 510(k) Summary - Addition of V40™ Femoral Head Components to the Ion Implanted Femoral Bearing Series Proprietary Name: Common Name: LFITTM V40TM Femoral Head Components Femoral Head Component Classification Name and Reference: 21 CFR 888.3350 Hip Joint Metal/ Polymer Semi-constrained Cemented Prosthe Proposed Regulatory Class: Device Product Code: For Information contact: (87) JDI, LWJ, KWY Jennifer A. Daudelin, Regulatory Affairs Howmedica Osteonics Corp. 59 Route 17 Allendale, NJ 07401-1677 (201) 934-4354 Fax: (201) 760-8435 Email: jdaudelin@howost.com This Special 510(k) submission is intended to add the V40™ femoral head components to the Ion Implanted Femoral Bearing Series. The intended use, manufacturing methods, materials, packaging and sterilization of the subject device are identical to those of predicate devices. The predicate ion implanted femoral bearing components were found substantially equivalent via the 510(k) process in K910988. The V40™ femoral head components were cleared in 510(k) numbers: K936126, K950541, and K993601. The predicate ion implanted devices are cobalt chromium alloy femoral heads conforming to ASTM F1537. The V40TM fernoral head components are also fabricated from cobalt chromium alloy conforming to ASTM F799. These devices have an outer diameter range from 22mm to 32mm with varying neck offsets. Like the predicate devices, the subject devices are intended for use with femoral stems and acetabular components in primary or revision total hip arthroplasty. {1}------------------------------------------------ #### DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" arranged around the perimeter. Inside the circle is a stylized symbol that resembles a bird or abstract human figure, composed of three curved lines. #### Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 ## APR 1 1 2001 Ms. Jennifer A. Daudelin Regulatory Affairs Howmedica Osteonics Corporation 59 Route 17 Allendale, New Jersey 07401-1677 Re: K010757 Trade Name: LFIT™ V40™ Femoral Heads Regulatory Class: II Product Code: JDI, LWJ, and KWY Regulation: 21 CFR 888.3350 Dated: March 12, 2001 Received: March 13, 2001 #### Dear Ms. Daudelin: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. {2}------------------------------------------------ #### Page 2 - Ms. Jennifer A. Daudelin If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html". Sincerely yours, Mark N Melhusen Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {3}------------------------------------------------ Indications for Use 510(k) Number (if known): K010757 Device Name: LFITTM V40TM Femoral Heads Indications for Use: These devices are modular components of a total hip system. These femoral heads are intended for use with femoral stems and acetabular components in primary or revision total hip arthroplasty. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use X (Per 21 CFR 801.109) OR Over-The-Counter Use (Optional Format 1-2-96) Murle N. Millkus Division Sign-Off) Division of General, Restorative and Neurological Devices 510(k) Number K010757
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...