← Product Code [HWC](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/HWC) · K172698

# G-Beam Fusion Beaming System (K172698)

_Orthofix Srl · HWC · Feb 7, 2018 · Orthopedic · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/HWC/K172698

## Device Facts

- **Applicant:** Orthofix Srl
- **Product Code:** [HWC](/submissions/OR/subpart-d%E2%80%94prosthetic-devices/HWC.md)
- **Decision Date:** Feb 7, 2018
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 888.3040
- **Device Class:** Class 2
- **Review Panel:** Orthopedic
- **Attributes:** Therapeutic

## Indications for Use

The G-Beam™ Fusion Beaming System is intended to be inserted in the foot and ankle for alignment, stabilization and fixation of various fractures and osteotomies, fusions and reconstructions. It is indicated for fracture and osteotomy fixation, reconstruction procedures, non-unions and fusions of the foot and ankle including metatarsals, cuneiforms, cuboid, navicular, calcaneus and talus. Specific example: medial and lateral column fusions resulting from neuropathic osteoarthropathy (Charcot osteoarthropathy).

## Device Story

G-Beam Fusion Beaming System; internal bone fixation system for foot and ankle. Device provides alignment, stabilization, and fixation for fractures, osteotomies, fusions, and reconstructions. Used by orthopedic surgeons in clinical settings. System components include metallic bone fixation fasteners (beams/bolts). Operates via mechanical fixation of bone segments to facilitate healing/fusion. Output is physical stabilization of bone structures. Benefits include restoration of alignment and structural integrity in complex foot/ankle pathologies like Charcot osteoarthropathy.

## Clinical Evidence

No clinical data. Safety and effectiveness supported by bench testing, including mechanical performance testing per ASTM F1264-16 and ASTM F-543-13, and pyrogenicity testing per USP 38 and ANSI/AAMI ST72:2011.

## Technological Characteristics

Metallic bone fixation fastener (screw/beam). Materials: metallic. Standards: ASTM F1264-16 (intramedullary fixation), ASTM F-543-13 (bone screws). Non-pyrogenic. Mechanical fixation principle.

## Regulatory Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

## Predicate Devices

- SALVATION™ Beams and Bolts System ([K140741](/device/K140741.md))
- Axis Charcot Fixation System ([K171018](/device/K171018.md))

## Reference Devices

- Orthofix External Fixation Screw (Pin) with hydroxyapatite coating ([K974186](/device/K974186.md))
- Orthofix Titanium Nailing Systems ([K053261](/device/K053261.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Image /page/0/Picture/0 description: The image shows the logos of the Department of Health and Human Services and the Food and Drug Administration (FDA). The Department of Health and Human Services logo is on the left and features a stylized human figure. The FDA logo is on the right and features the letters "FDA" in a blue square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue text.

February 7, 2018

Orthofix Srl Gianluca Ricadona Sr. Quality & Regulatory Affairs Manager Via delle Nazioni, 9 37012 Bussolengo (VR) Italy

Re: K172698

Trade/Device Name: G-Beam Fusion Beaming System Regulation Number: 21 CFR 888.3040 Regulation Name: Smooth Or Threaded Metallic Bone Fixation Fastener Regulatory Class: Class II Product Code: HWC Dated: January 5, 2018 Received: January 8, 2018

Dear Gianluca Ricadona:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820);

{1}------------------------------------------------

and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).

Sincerely,

# Katherine D. Kavlock -S

for Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{2}------------------------------------------------

## Indications for Use

Form Approved: OMB No. 0910-0120 Expiration Date: 06/30/2020 See PRA Statement below.

510(k) Number (if known) K172698

Device Name G-Beam™ Fusion Beaming System

#### Indications for Use (Describe)

The G-Beam™ Fusion Beaming System is intended to be inserted in the foot and ankle for alignment,

stabilization and fixation of various fractures and osteotomies, fusions and reconstructions.

It is indicated for fracture and osteotomy fixation, reconstruction procedures, non-unions and fusions of the foot and ankle including metatarsals, cuneiforms, cuboid, navicular, calcaneus and talus.

Specific example: medial and lateral column fusions resulting from neuropathic osteoarthropathy (Charcot osteoarthropathy).

| Type of Use (Select one or both, as applicable)            |                                                           |
|------------------------------------------------------------|-----------------------------------------------------------|
| <span></span> Prescription Use (Part 21 CFR 801 Subpart D) | <span></span> Over-The-Counter Use (21 CFR 801 Subpart C) |

### CONTINUE ON A SEPARATE PAGE IF NEEDED.

This section applies only to requirements of the Paperwork Reduction Act of 1995.

#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW *

The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:

> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov

"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."

{3}------------------------------------------------

Image /page/3/Picture/1 description: The image shows the logo for Orthofix, a medical device company. Below the logo is the text "510(k) Summary" and the text "(as required by 21 CFR 807.92)". The logo consists of the word "ORTHOFIX" in a bold, sans-serif font, with a registered trademark symbol next to it. Above the word is a blue, abstract shape.

| Submitter Name | Orthofix Srl                                         |
|----------------|------------------------------------------------------|
| Address        | Via delle Nazioni, 9   37012 Bussolengo (VR) - Italy |
| Telephone      | + 39 045 6719.000                                    |
| Fax            | + 39 045 6719.380                                    |

| Contact Person | Gianluca Ricadona<br>Sr. Quality & Regulatory Affairs Manager |
|----------------|---------------------------------------------------------------|
| Address        | Via delle Nazioni, 9<br>37012 Bussolengo (VR) - Italy         |
| Telephone      | + 39 045 6719 000                                             |
| Fax            | + 39 045 6719 380                                             |
| email          | GianlucaRicadona@orthofix.it                                  |
| Date Prepared  | February 5, 2018                                              |

| Trade Name        | G-Beam™ Fusion Beaming System                      |
|-------------------|----------------------------------------------------|
| Common Name       | Screw, fixation, bone                              |
| Panel Code        | Orthopedic                                         |
| Classification    | Smooth or threaded metallic bone fixation fastener |
| Name              |                                                    |
| Class             | Class II                                           |
| Regulation Number | 21 CFR 888.3040                                    |
| Product Code      | HWC                                                |

| Predicate Device Name                                                                       | 510(k) Number | Manufacturer                    |
|---------------------------------------------------------------------------------------------|---------------|---------------------------------|
| SALVATION™ Beams and Bolts<br>System                                                        | K140741       | Wright Medical Technology, Inc. |
| Axis Charcot Fixation System                                                                | K171018       | Extremity Medical LLC           |
| Orthofix External Fixation Screw<br>(Pin) with hydroxyapatite coating<br>(Reference device) | K974186       | Orthofix SRL                    |
| Orthofix Titanium Nailing Systems<br>(Reference device)                                     | K053261       | Orthofix SRL                    |

{4}------------------------------------------------

| procedures, non-unions and fusions of bones of the foot and ankle   |
|---------------------------------------------------------------------|
| including metatarsals, cuneiforms, cuboid, navicular, calcaneus and |
| talus.                                                              |
| Specific example: medial and lateral column fusions resulting from  |
| neuropathic osteoarthropathy (Charcot osteoarthropathy).            |

{5}------------------------------------------------

| Technological<br>Characteristics and<br>Substantial<br>Equivalence | Documentation was provided to demonstrate that the G-Beam™<br>Fusion Beaming System is substantially equivalent to the legally<br>marketed predicates.<br>Components and instrumentation included in the G-Beam™ Fusion<br>Beaming System and the predicate device are both internal fracture<br>fixation systems, as defined in 21 CFR 888.3040.<br>The G-Beam™ Fusion Beaming System is substantially equivalent<br>to the predicate devices in: intended use, site of application, patient<br>population, conditions of use, mechanical performances, operating<br>principles.<br>Mechanical testing show how the mechanical properties of the<br>subject device are equivalent or better than the predicate device.                                                                                                                            |
|--------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Performance Data                                                   | The potential hazards have been evaluated and controlled through<br>a Risk Management Plan.<br>All testing met or exceeded the requirements as established by the<br>test protocols and applicable standards. A review of the mechanical<br>data indicates that the components of the Subject device are<br>capable of withstanding expected loads without failure. The Subject<br>device was therefore found to be substantially equivalent to the<br>predicate device. Clinical data was not needed to support the<br>safety and effectiveness of the Subject Device.<br>Mechanical testing was performed according to the following<br>standards:<br>• ASTM F1264-16 "Standard Specification and Test Methods<br>for Intramedullary Fixation Devices".<br>• ASTM F-543-13 "Standard Specification and Test Methods<br>for metallic bone screws" |
| Pyrogenicity<br>data                                               | In order to establish the Subject device non-pyrogenicity, tests were<br>performed according to the following international standards:<br>• USP 38: 2014 < 85 > "Bacterial endotoxin test (LAL)".<br>• USP 38: 2014 < 161 > "Medical devices – bacterial endotoxin<br>and pyrogen tests".<br>• ANSI / AAMI ST72: 2011 "Bacterial endotoxins – Test<br>methodologies, routine monitoring and alternative batch testing".                                                                                                                                                                                                                                                                                                                                                                                                                            |
| Conclusion                                                         | Based upon similarities in: intended use, site of application, patient<br>population, conditions of use, mechanical performances, operating<br>principles, and according to the results of mechanical testing, G-Beam™ Fusion Beaming System has been shown to be<br>substantially equivalent to the legally marketed predicate device and<br>to be as safe and effective as the predicate for its intended use.                                                                                                                                                                                                                                                                                                                                                                                                                                   |

---

**Source:** [https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/HWC/K172698](https://fda.innolitics.com/submissions/OR/subpart-d%E2%80%94prosthetic-devices/HWC/K172698)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
